Catalog Datasheet MFG & Type PDF Document Tags
2009 - V23136-J1004-X050

Abstract: V23136 tyco relay V23136 tyco V23136 ISO 7588 UL94-HB and FMVSS 1-1414122-0 UL94-HB and FMVSS 302 RS-407-A 68242
Text: Conditions All parametric, environmental and endurance tests are performed according to EIA Standard RS , ±33.9 hPa. For general storage and processing recommendations please refer to our Application Notes and , or liability for not complying herewith. We recommend to complete our questionnaire and to request , with suitable spark suppression and at maximum 13.5 V for 12 V load voltages. For a load current , /contact and contact/contact Ambient temperature range Operate time at nominal voltage Release time at


Original
PDF V23136-* V23136-J1004-X050 V23136 tyco relay V23136 tyco V23136 ISO 7588 UL94-HB and FMVSS 1-1414122-0 UL94-HB and FMVSS 302 RS-407-A 68242
UL94-HB and FMVSS

Abstract: sae j 590 UL94-HB and FMVSS 302 VTF-14F11 VTF-11F31 12015864 FLASHER STANDARD MOTOR vtf 108 J945 FMVSS-302
Text: (turn signal) SAE J 945 (hazard warning) SAE J 2068 (turn signal/hazard warning) FMVSS 108 (all , Combination turn signal and hazard warning signal flasher.(1) · Meets all applicable U.S.A. safety standards , Wide operating voltage and temperature range. Operating Ambient Temperature Range: -40°C to +85°C. , amplitude. 100-500 Hz., 10g's constant. Conditions All parametric, environmental and life tests are , 2x3.5W + 2x1.3W Abnormal Operation Flash Rate and Duty Cycle Data Turn Signal Mode Drop Test


Original
PDF 24A111 VCF4-1000 VCF4-1001 VCF4-1002 26A1349A 26A1349B 26A1348A 26A1348B 26A1348C 13C8831 UL94-HB and FMVSS sae j 590 UL94-HB and FMVSS 302 VTF-14F11 VTF-11F31 12015864 FLASHER STANDARD MOTOR vtf 108 J945 FMVSS-302
2005 - glow plug relay

Abstract: ISO 7588 glow plug relay "7 pin" V23140-J0053-D642
Text: A, 0.5 s 420 A, 0.1 s 1) 2) Current FMVSS : Federal Motor Vehicle Safety Standard. and time , , environmental and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions , recommend to complete our questionnaire and to request our technical service. Any responsibility for the , values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for , device in parallel to the relay coil increases the release time and reduces the lifetime caused by


Original
PDF V23140-J0053-D642 V23140-* glow plug relay ISO 7588 glow plug relay "7 pin" V23140-J0053-D642
2006 - VRM-0032

Abstract: vrm circuit testing UL94-HB and FMVSS VRM Catalog 1308028
Text: motor reversing applications such as Engine Compartment Cover Lift, on off road and construction equipment. - The patented control circuit prevents the possibility of arcover between B+ and ground in the , Conditions All parametric, environmental and endurance tests are performed according to EIA Standard RS , . Expected life 100,000 cycles (forward and reverse cycles) at 20 A, 28 VDC, 1 mH Disclaimer All , questionnaire and to request our technical service. Any responsibility for the application of the product


Original
PDF
2006 - VJ28-91F24-S01

Abstract: UL94-HB and FMVSS tyco relay vj28 VJ28-95F24-S01
Text: _3d1 Design Plastic enclosure Conditions All parametric, environmental and endurance tests are performed , responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request , suppression and at maximum 13.5 V for 12 V. For a load current duration of maximum 3 s for a make/break ratio , time and reduces the lifetime caused by increased erosion and /or higher risk of contact tack welding , better (meets FMVSS 302)1) 27 A, 1800 s 40 A, 5 s 70 A, 0.5 s 120 A, 0.1 s Comments Valid for NC contacts


Original
PDF J1744) RS-407-A VJ28-* VJ28-91F24-S01 UL94-HB and FMVSS tyco relay vj28 VJ28-95F24-S01
2009 - VF4-65F11-S01

Abstract: double mini relays tyco vf4-55f11-s01 VF4-15F11-S01 tyco vf4-15f11 relay vf4-45f11 FOR5G vf4-15f21-s01 VF4-45F11 UL94-HB and FMVSS
Text: Plug-In Relays Mini ISO Relays VF4 A (Standard, Shrouded and Weatherproof) Catalog 1308028-2 , connect terminals similar to ISO 8092-1, coil and load 6.3 x 0.8 mm; surfaces tin plated Conditions All parametric, environmental and endurance tests are performed according to EIA Standard RS-407-A at , . For general storage and processing recommendations please refer to our Application Notes and , our questionnaire and to request our technical service. Any responsibility for the application of the


Original
PDF
2008 - UL94-HB and FMVSS

Abstract: ISO 16750-2 V23145-L1101-A402 ISO 7588 Relay c FMVSS-302
Text: , 0.5 s 120 A, 0.1 s 1) 2) FMVSS : Federal Motor Vehicle Safety Standard. Current and time are , Features ­ Magnetically latched ISO plug-in relay ­ Two coils with set and reset function ­ Pin assignment , IEC 529 (EN 60 529) Terminals Quick connect terminals similar to ISO 8092-1, coil and break 4.8 x , and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions unless otherwise noted: 23°C ambient temperature, 20 - 50% RH, 998.9 ±33.9 hPa. For general storage and


Original
PDF
2005 - tyco relay vj28

Abstract: VJ28-91F24-S01 VJ28-95F24-S01 J1744
Text: external 1) 2) Current FMVSS : Federal Motor Vehicle Safety Standard. and time are compatibel with , _3d1 Design Plastic enclosure Conditions All parametric, environmental and endurance tests are performed , responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request , suitable spark suppression and at maximum 13.5 V for 12 V. For a load current duration of maximum 3 s for a , relay coil increases the release time and reduces the lifetime caused by increased erosion and /or higher


Original
PDF J1744) RS-407-A VJ28-* tyco relay vj28 VJ28-91F24-S01 VJ28-95F24-S01 J1744
2006 - 5 pin relay NO NC

Abstract: No abstract text available
Text: , environmental and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions , recommend to complete our questionnaire and to request our technical service. Any responsibility for the , The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 , the relay coil increases the release time and reduces the lifetime caused by increased erosion and /or , meeting specifications after 1.0 m (3.28 foot) drop onto concrete UL94-HB or better (meets FMVSS 302)1) 95


Original
PDF V23140-J0053-D642 V23140-* 5 pin relay NO NC
2009 - V23136

Abstract: V23136-A1001-X057 V23136 tyco relay V23136-B1001-X051 V23136 tyco 36 pin FCI connector 136 mini iso shrouded relays
Text: connector Terminals Quick connect terminals similar to ISO 8092-1, coil and load 6.3 x 0.8 mm; surfaces tin plated Conditions All parametric, environmental and endurance tests are performed according to , - 50% RH, 998.9 ±33.9 hPa. For general storage and processing recommendations please refer to our Application Notes and especially to Storage in the "Glossary" page 23 or at http://relays.tycoelectronics.com , responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request


Original
PDF V23136-* V23136 V23136-A1001-X057 V23136 tyco relay V23136-B1001-X051 V23136 tyco 36 pin FCI connector 136 mini iso shrouded relays
2006 - VTF-14F11

Abstract: UL94-HB and FMVSS VTF-21F31 electronic flasher relay VTF-22F31 vtf 108
Text: Convenience Description Features - Combination turn signal and hazard warning signal flasher1) - Lamp , timing - VKP relay with PdCu contact for output - Fits ISO 7588 socket - Wide operating voltage and temperature range Car Industry Typical applications Flasher and turn signals 1) Truck Industry , . Design Dustproof, plastic enclosure Conditions All parametric, environmental and endurance tests are , liability for not complying herewith. We recommend to complete our questionnaire and to request our


Original
PDF VTF-11F21 VTF-11F31 VTF-12F21 VTF-13F21 VTF-21F21 VTF-21F31 VTF-22F21 VTF-22F31 VTF-14F11 UL94-HB and FMVSS electronic flasher relay vtf 108
2010 - VFM-15F41-S01

Abstract: v23074-a1001-a402 V23074 vfm-15f41 V23074-A1001-A403 V23074-H1005-A502
Text: A, 0.5 s 150 A, 0.1 s 1) 2) FMVSS : Federal Motor Vehicle Safety Standard. Current and time are , terminals similar to ISO 8092-1, coil and break 4.8 x 0.8 mm, load 6.3 x 0.8 mm; surfaces tin plated Conditions All parametric, environmental and endurance tests are performed according to EIA Standard RS , ±33.9 hPa. For general storage and processing recommendations please refer to our Application Notes and , recommend to complete our questionnaire and to request our technical service. Any responsibility for the


Original
PDF V23074-* VFM-15F41-S01 v23074-a1001-a402 V23074 vfm-15f41 V23074-A1001-A403 V23074-H1005-A502
2006 - ISO 7588

Abstract: V23074 VFMA-21F42-S01 v23074-a1001 V23074-A1001-A403 tyco varistor catalog VFMA-15F41-S01 V23074-A1002-A403 V23074-A1002-A402 vfma-11f41
Text: (5 °C per min.) FMVSS : Federal Motor Vehicle Safety Standard. and time are compatible with , coil - Special labels Weight All parametric, environmental and endurance tests are performed , connect terminals similar to ISO 8092-1 Coil and break contact 4.8 x 0.8 mm, other load terminals 6.3 x , herewith. We recommend to complete our questionnaire and to request our technical service. Any , values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for


Original
PDF -S012) -S022) ISO 7588 V23074 VFMA-21F42-S01 v23074-a1001 V23074-A1001-A403 tyco varistor catalog VFMA-15F41-S01 V23074-A1002-A403 V23074-A1002-A402 vfma-11f41
2005 - v23134

Abstract: tyco V23134-j1052-d642 V23134-J0056-X408 V23134-J1052-D642 V23134-J0052-D642 V23134-J1053-D642 V23134-J0053-D642 9-1393303 V23134-j1052 UL94-HB and FMVSS
Text: as per FMVSS : Federal Motor Vehicle Safety Standard. and time are compatible with circuit , Description Features ­ Limiting continuous current 70 A ­ Dimensional characteristics and the functional , shapes Weight All parametric, environmental and endurance tests are performed according to EIA , herewith. We recommend to complete our questionnaire and to request our technical service. Any , suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages. For a load current duration of


Original
PDF prote6-X408 V23134-* v23134 tyco V23134-j1052-d642 V23134-J0056-X408 V23134-J1052-D642 V23134-J0052-D642 V23134-J1053-D642 V23134-J0053-D642 9-1393303 V23134-j1052 UL94-HB and FMVSS
2005 - VF7-11H12

Abstract: 11f11 VF7-41F11-C05 11H11 VF711F12 VF7-41F11 VF7-11F12 VF7-41H11 UL94-HB and FMVSS ISO 7588
Text: FMVSS : Federal Motor Vehicle Safety Standard. and time are compatible with circuit protection by a , Description Features ­ Limiting continuous current 70 A ­ Dimensional characteristics and the functional , , environmental and endurance tests are performed according to EIA Standard RS-407-A at standard test , our questionnaire and to request our technical service. Any responsibility for the application of the , values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for


Original
PDF
2009 - Not Available

Abstract: No abstract text available
Text: , 0.5 s 420 A, 0.1 s FMVSS : Federal Motor Vehicle Safety Standard. Current and time are compatible , Application Specific Switching Solutions Basic Module Relays – F4/F7 and Base Catalog , adjustment – Seat and stationary heating – Timer – Wiper control 140_kop1 Design Terminals , €“ Power Module F4: Quick connect terminals similar to ISO 8092-1, coil and load 6.3 x 0.8 mm; surfaces , , load 9.5 x 1.2 mm; surfaces tin plated All parametric, environmental and endurance tests are


Original
PDF V23140-J0053-D642 V23140-*
circuit diagram of turn signal light of a car

Abstract: 12v electronic flasher without relay sae j590 FLASHER RELAY IC for electronic flasher FLASHER STANDARD MOTOR UL94-HB and FMVSS 2 pin flasher relay flasher j590
Text: industry standards such as Federal Motor Vehicle Safety Standard 108 ( FMVSS 108) and Society of , specified by FMVSS 108 and is intended to insure that lamps are provided with adequate voltage to be , indicate when the flasher is operating and a turn signal lamp outage indicator. Hazard Warning Flasher , function of causing the left and right turn signal lamps to flash when the hazard warning switch is activated. Secondary functions may include visible pilot indicators for the hazard system and an audible


Original
PDF 13C3310 IH/r3-08 circuit diagram of turn signal light of a car 12v electronic flasher without relay sae j590 FLASHER RELAY IC for electronic flasher FLASHER STANDARD MOTOR UL94-HB and FMVSS 2 pin flasher relay flasher j590
V23086-C2001-A303

Abstract: V23086-C1001-A303 v23086-c1001-a402 tyco v23086 c1001 a303 v23086-c1001-a403 V23086-C1001 tyco V23086-c1001-a303 V23086C2001A303 vfm-15f41 24V 30A SPDT RELAY wiring diagram
Text: . Flammability: UL94V-0 (meets FMVSS 302). Notes Between Contacts and Coil: 10 megaohms. Between Open , better, internal parts (meets FMVSS 302). Notes Coil Data Voltage: 6, 12 and 24VDC. Resistance , (meets FMVSS 302). Notes Coil Data Voltage: 12 and 24VDC. Resistance: See Coil Data table. Nom , (meets FMVSS 302). Initial Dielectric Strength Between Contacts and Coil: 500V rms. Notes Coil , Data · · · · · · · Must Operate and Must Release Voltage: See Coil Data table. Initial


Original
PDF 16VDC 16VDC. 24A111 VCF4-1000 VCF4-1001 VCF4-1002 26A1349A 26A1349B 26A1348A 26A1348B V23086-C2001-A303 V23086-C1001-A303 v23086-c1001-a402 tyco v23086 c1001 a303 v23086-c1001-a403 V23086-C1001 tyco V23086-c1001-a303 V23086C2001A303 vfm-15f41 24V 30A SPDT RELAY wiring diagram
2008 - UL94-HB and FMVSS

Abstract: J1744 VF28 VF28-11F14-S01 VF28-61F14-S01 UL94-HB and FMVSS 302 61F14 relay VF28-15F14-S01 TYCO vf28-11f14-s01
Text: 1) 2) FMVSS : Federal Motor Vehicle Safety Standard. Current and time are compatible with , 280 Relays Catalog 1308028-2 Revised 3-2008 VF28 (Standard and Shrouded) Features ­ , J1744; coil and load 2.8 mm dual in-line All parametric, environmental and endurance tests are , Approx. 34 g (1.2 oz.) Nominal Voltage 12 V or 24 V For general storage and processing recommendations please refer to our Application Notes and especially to Storage in the "Glossary" page 23 or at


Original
PDF 02-Plug-in J1744) VF28-* UL94-HB and FMVSS J1744 VF28 VF28-11F14-S01 VF28-61F14-S01 UL94-HB and FMVSS 302 61F14 relay VF28-15F14-S01 TYCO vf28-11f14-s01
2009 - V23132-A2001-B200

Abstract: V23132-A2001-A200 V23132-A2001-A100 V23132 V23132-B2002-A100 v23132-a2001-b100 V23132-B2002-B200 281934-2 A170A AMP superseal 1.0
Text: Suitable for voltage levels up to 42 V ­ Heat, moisture and vibration resistant ­ Minimal contact resistance ­ Dustproof and sealed versions Typical Applications ­ ­ ­ ­ Engine control Glow Plug Heated , Quick connect terminals (coil) ­ Screw terminals (load) Conditions All parametric, environmental and , otherwise noted: 23°C ambient temperature, 20 - 50% RH, 998.9 ±33.9 hPa. For general storage and processing recommendations please refer to our Application Notes and especially to Storage in the "Glossary" page 23 or at


Original
PDF cleanaP54 V23132-B2002-A100 V23132-B2002-A200 V23132-B2002-B100 V23132-B2002-B200 V23132-* V23132-A2001-B200 V23132-A2001-A200 V23132-A2001-A100 V23132 v23132-a2001-b100 V23132-B2002-B200 281934-2 A170A AMP superseal 1.0
2006 - V23132-A2001-B200

Abstract: c2038 UL94-HB and FMVSS 302 V23132-C2001-A100 V23132-A2001-A200
Text: and vibration resistant - Minimal contact resistance Typical applications - Preheating air for , Electrical pumps - Primary and /or engine switches - Electrical valve control - Switches for loading ramps - , , environmental and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions , responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request , spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages. For a load current


Original
PDF V23132-B2002-A100 V23132-B2002-A200 V23132-B2002-B100 V23132-B2002-B200 V23132-C2001-A100 V23132-C2001-A200 V23132-* V23132-A2001-B200 c2038 UL94-HB and FMVSS 302 V23132-A2001-A200
2005 - ISO 7588

Abstract: v23074-a1001 VFMA-21F42-S01 15F-41 V23074-A1001-A403 v23074-a1001-a402 V23074-A1002-A403 VFMA-25F41-S01 v23074 VFMA-15F41-S01
Text: Weight All parametric, environmental and endurance tests are performed according to EIA Standard RS , similar to ISO 8092-1 Coil and break contact 4.8 x 0.8 mm, other load terminals 6.3 x 0.8 mm; surfaces , our questionnaire and to request our technical service. Any responsibility for the application of the , or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V , N.B. A low resistive suppression device in parallel to the relay coil increases the release time and


Original
PDF -S012) -S022) ISO 7588 v23074-a1001 VFMA-21F42-S01 15F-41 V23074-A1001-A403 v23074-a1001-a402 V23074-A1002-A403 VFMA-25F41-S01 v23074 VFMA-15F41-S01
2009 - VFM-15F41-S01

Abstract: Tyco V23074 V23074 V23074-A1002-A403 VFM-11F41-S01 v23074-a1001 7637-2 pulse 5 7637-2 vfm-15f41 UL94-HB and fmvss
Text: connect terminals similar to ISO 8092-1, coil and break 4.8 x 0.8 mm, load 6.3 x 0.8 mm; surfaces tin , parametric, environmental and endurance tests are performed according to EIA Standard RS-407-A at standard , general storage and processing recommendations please refer to our Application Notes and especially to , questionnaire and to request our technical service. Any responsibility for the application of the product , values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for


Original
PDF V23074-* VFM-15F41-S01 Tyco V23074 V23074 V23074-A1002-A403 VFM-11F41-S01 v23074-a1001 7637-2 pulse 5 7637-2 vfm-15f41 UL94-HB and fmvss
2006 - V23086-L1252-A403

Abstract: truck ecu ISO-8092-2 temperature circuit diagram in ecu rs 6V relay
Text: and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions , and load 6.3 x 0.8 mm, surface tin-pated Disclaimer All technical performance data apply to the , liability for not complying herewith. We recommend to complete our questionnaire and to request our , Management Modules Dimensional drawing V23141-B0001-X030 and X037 Dimensional drawing V23141-B0001-X031 and , 141X31vt1 Circuit diagram V23141-B0001-X030 and X037 Circuit diagram V23141-B0001-X031 and X038


Original
PDF V23141-B0001-X0301) V23141-B0001-X0371) V23141-B0001-X0312) V23141-B0001-X0382) V23086-L1252-A403 truck ecu ISO-8092-2 temperature circuit diagram in ecu rs 6V relay
t72m5d121

Abstract: UL94-HB and FMVSS T72M5D121 12 16 T72M RELAY 80A 24V SPDT
Text: Data · · · · · · · Must Operate and Must Release Voltage: See Coil Data table. Initial , . Conditions Environmental Data All parametric, environmental and life tests are performed according to , 0.15 - Recommended for inductive loads. AgSnO - Recommended for high inrush, lamp and capacitive loads and applications prone to contact material transfer. Max. Switching Rate: 20 operations per , final enclosure. Flammability: UL94-HB or better (meets FMVSS 302). Initial Dielectric Strength


Original
PDF 16VDC 16VDC. 13C8726 IH/4-00 t72m5d121 UL94-HB and FMVSS T72M5D121 12 16 T72M RELAY 80A 24V SPDT
Supplyframe Tracking Pixel