Part Manufacturer Description Datasheet Download Buy Part
PMP8012 Texas Instruments TPS92310 - 220VAC, 8W Isolated , Triac dimmable
PMP6002 Texas Instruments TRIAC Dimmable 120V LED Lighting Driver Controller (32V@350mA)
PMP6003 Texas Instruments TRIAC Dimmable 230V LED Lighting Driver Controller (32V@350mA)
LM3445MMX/NOPB Texas Instruments Triac Dimmable Offline LED Driver 10-VSSOP -40 to 125
LM3497MX/NOPB Texas Instruments LM3497 Triac Dimmable Offline LED Driver 14-SOIC
LM3497MMX/NOPB Texas Instruments LM3497 Triac Dimmable Offline LED Driver 10-MSOP

TRIAC bt 824 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2008 - triacs BTA

Abstract: BC557 in smd package triac snubber ac motor SM1L43 triacs bt 12 Triac ACS108 controlling heater with triac washing machine drain valve types universal motor speed control wash ac motor control with triac
Text: can pose a particular challenge. NXP's BTA208X-1000C triac offers best-in-class performance in this , the AC mains supply. Each triac 's operation has to be mutually exclusive, to avoid uncontrolled , sinusoidal voltage (higher than the mains supply voltage), and the triac needs to be able to block the , inductor is not necessary The NXP BTA208X-1000C is the only three-quadrant Hi-Com triac to guarantee a , , motor speed varies widely. A triac is typically used to control the speed, via phase-control of the


Original
PDF
2007 - 1M preset

Abstract: triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control washing machine drain valve types induction heater microcontroller 100n N 250v X2
Text: and surface-mount options G+ The simple, reliable and inexpensive triac is used to control , Eliminates need for snubber circuit High dVD/dt Triac voltage Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC SNUBBER NOT REQUIRED Ñ igher dVcom/dt , commutation - Eliminates need for snubber circuit Triac voltage High dVCOM/dt Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC Load Current SNUBBER NOT


Original
PDF BTA225 BTA225B 1M preset triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control washing machine drain valve types induction heater microcontroller 100n N 250v X2
triac BT 24

Abstract: triacs bt 138 TRIAC 138 triac BT 138 BT 138 bt138 triac BT 4 400 BT138-500 TRIAC TAG 90 triac BT 24 600
Text: N AMFR PHILIPS/DISCRETE b«ÌE T> bbsg'oi DD272n no hapx BT 138 SERIES X TRIACS , Respective Manufacturer I I N AMER PHILIPS/DISCRETE BT 138 SLKItb b^E T> bbSB^l 0D27HH0 'iOH MAPXl A , VDSM VDRM VDWM 'T(RMS) max-'TRM max- ■tsm 'tsm l2t BT 138- -500 600 700 800 max. 500* 600* 700 , , but the triac may switch into the on-state. The rate of rise of on-state current should not exceed 15 , Respective Manufacturer N AMER PHILIPS/DISCRETE BT 138 SLKItb blE » (^53^31 DD27252 70S «APX JL vT


OCR Scan
PDF DD272n bt138-500 220AB BT138 BT138F triac BT 24 triacs bt 138 TRIAC 138 triac BT 138 BT 138 triac BT 4 400 TRIAC TAG 90 triac BT 24 600
BTi36

Abstract: TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 BT136 triac BT 06 700 PH 600D B 134 bt 136
Text: ) max- BT 136- -500 600 700 800 max. 500 600 700 800 'tsm 'tsm max. max. 25 30 V A A MECHANICAL DATA Fig , . ^Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , will not trigger any device; Tj = 120 °C; gate open circuit BT 136 series dVD/dt < 100 V/fis BT 136 series G dVD/dt < 200 V/jis BT 136 series F dVD/dt < 50 V/m s BT136 series E dVD/dt typ. 50 V , current {!(.) Latching current (![_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT136


OCR Scan
PDF 00bE23a BT136 BT136F d8573 BTi36 TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 triac BT 06 700 PH 600D B 134 bt 136
triac BT 317

Abstract: BT 317 triac triac BT 06 600 triac BT 24 BT134 BT134-500D triac BT 06 400 triac BT 06 700 triacs BT 134 w triac BT 134
Text: N AMER PHILIPS/DISCRETE b^E T> m bbSa^Bl 002715b 1Ô7 HIAPX BT 134 SERIES y v. TRIACS , damage, but the triac may switch into the on-state. The rate of rise of on-state current should not , 1.8 A/ms; ¡T BT 134 series dVcom/dt typ. 10 V/fis BT 134 series G dVcom/dt < 10 V/jus BT 134 series F dVCom/dt typ. 10 V/a-s Off-state , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 002715b bt134-500 BT134G BT134 00271b5 BT134F triac BT 317 BT 317 triac triac BT 06 600 triac BT 24 BT134-500D triac BT 06 400 triac BT 06 700 triacs BT 134 w triac BT 134
triac BT 137

Abstract: triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 BT137 triac BT 137 600 triac BT 06 600 TRIAC TAG 91
Text: PHILIPS INTERNATIONAL bSE D 711GÖ2L, D0b2Ebl 27b HIPHIN BT 137 SERIES s V TRIACS Glass-passivated , BT 137 -500 600 700 800 max. 500 600 700 800 max. max. max. 55 60 V A A MECHANICAL DATA Fig.1 TOâ , either direction) BT 137-500 600 700 800 Non-repetitive peak off-state voltage (t < 10 ms)t VDSM max , without damage, but the triac may switch into the on-state. The rate of rise of on-state current should , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 00b2271 BT137 M1Q41 BT137F D8573 M81-1647/1 triac BT 137 triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 triac BT 137 600 triac BT 06 600 TRIAC TAG 91
1997 - triac BT 140

Abstract: 2kw TRIAC control triac burst control ic TRIAC BT 139 TRIAC 226 a triac 226 triac burst firing circuit triac applications circuit diagram BT 140 triac triac switch circuits
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
triac tag 87

Abstract: TRIAC BT 136 BT136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 D8384 bt136 triac triac BT 06 400
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , current (l|_j) Latching current (l[_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT > 35 H < 15 L <20 GT > 50 H < 30 L <30 GT H L > 25 < 15 < 20 GT H L > 10 , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF 711Da2b 0Db523Ã BT136 BT136-500 M1625 BT136G 711002b 00b224Ã M1644 triac tag 87 TRIAC BT 136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 D8384 bt136 triac triac BT 06 400
TRIAC BT 136

Abstract: BT 136 TRIAC BT136 working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT , the temperature of the terminals does not exceed 125 °C. During these overload conditions the triac , . on-state current based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may , IPHIN M 1 643 Fig.8 Typical commutation dV/dt for BT136 series versus Tj. The triac should commutate


OCR Scan
PDF 711Da2b 00bS23Ã BT136 BT136-500 711005b 00b224Ã M1644 BT136F D8573 TRIAC BT 136 BT 136 TRIAC working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
2013 - 1 kilo ohm resistor specifications

Abstract: RESISTOR 50 KILO OHM 2.2 kilo ohm resistor specifications
Text: GuardSwitch Series 300 Switches 301- BT and 303- BT Installation Sheet Figure 1: Dimensions Description The 301- BT Series 300 DPST safety interlock switch is designed for use with safety monitored relays or monitored circuits. To achieve the optimum Series 300 defeat resistant feature of the 301- BT , The housing of the 300- BT must be connected to the PE (Primary Earth) ground circuit via a lock , or nuts. See ordering information for details. Set range at 20 mega ohms (switches with triac


Original
PDF 301-BT 303-BT 301-BT, 73/23/EEC) EN60204-1 EN292 EN954-1 EN55081-2 EN50082-2 1 kilo ohm resistor specifications RESISTOR 50 KILO OHM 2.2 kilo ohm resistor specifications
triac bt 135

Abstract: triac BT 140 TAG 84 triac TRIAC BT 139 BT 139 F applications note bt 139 BT 140 triac BT139 triac BT 147 triac BT 24
Text: current 'T(RMS) Non-repetitive peak on-state current at 50 Hz ITS(V] at 60 Hz lTSM BT 139- -500 600 700 , (in either direction) BT 139- -500 600 700 800 Non-repetitive peak off-state voltage (t< 10 ms) VDSM , recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the , ; = 120 °C; gate open circuit 1.6 bt 139 series dVD/dt < 100 V/MS bt139 series G dVD/dt < 200 V/MS , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose


OCR Scan
PDF 711002b 00L23Q7 BT139 220AB triac bt 135 triac BT 140 TAG 84 triac TRIAC BT 139 BT 139 F applications note bt 139 BT 140 triac triac BT 147 triac BT 24
1995 - triac BT 140

Abstract: triac burst control ic 2kw TRIAC control ac voltage stabiliser circuit diagram ramp generator triac BT 139 TRIAC 226 a stabiliser circuit diagram triac applications circuit diagram 443A
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
Not Available

Abstract: No abstract text available
Text: /DISCRETE BT136F SERIES b'lE D bt >S3^31 0027165 T l l ff J v. RATINGS Limiting values in , recommended, off-state voltages up to 800 V may be applied w ithout damage, but the triac may switch into the , 15 20 10 15 15 25 15 20 mA mA mA BT 136F — 500D/600D 82 'g t lH !g t , J MOUNTING INSTRUCTIONS 1. The triac may be soldered directly into the circuit, but the maximum , terminals does not exceed 125 °C. During these overload conditions the triac may lose control. Therefore


OCR Scan
PDF D0271fl4 BT136F OT-186 BT136Fâ 10Typical
triac BT 137

Abstract: TRIAC TAG 137 Triacs bt 137 TRIAC TAG 91 BT137 application note BT137-500 TRIAC TAG 90 triac BT 137 800 triac BT 16 rating triac BT 41
Text: PHILIPS INTERNATIONAL bSE D B TllOûSfci DOLEEtil 27b HIPHIN BT 137 SERIES y v. TRIACS , damage, but the triac may switch into the on-state. The rate of rise of on-state current should not , 30 45 piA !GT > 10 10 10 25 mA BT 137 series E l|H < 20 20 20 20 mA ' L < 25 35 25 35 mA , does not exceed 125 °C. During these overload conditions the triac may lose control. Therefore the , based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF BT137â triac BT 137 TRIAC TAG 137 Triacs bt 137 TRIAC TAG 91 BT137 application note BT137-500 TRIAC TAG 90 triac BT 137 800 triac BT 16 rating triac BT 41
1984 - 2kw TRIAC control

Abstract: TRIAC 226 d triac BT 140 triac burst firing circuit Automatic Voltage stabilizer 5 kw J7770 zero detector ic of ac mains triac BT 139 triac burst control ic Peak level meter ic
Text: can be calculated. p eg. for triac BT 139 (see data sheet 2488) worst case holding current I = 30mA , . offering symmetrical burst Features control of an external triac . Ideal for power control in l High immunity against spurious triac firing many heating applications. under noisy mains conditions l Low , triac trigger pulse and pin 5 output - -7.2 mA R resistance range total 18 -140 kW p Triac gate drive , to the 7.0V tive or low power resistive, the triac load current series stabilizer which feeds the


Original
PDF J7770 2kw TRIAC control TRIAC 226 d triac BT 140 triac burst firing circuit Automatic Voltage stabilizer 5 kw J7770 zero detector ic of ac mains triac BT 139 triac burst control ic Peak level meter ic
M1641 TRIAC

Abstract: BT137 CIRCUITS M1641 TRIAC TAG 91 BT137 TRIAC TAG 626 400 bt137* soldering iron temperature control triac BT 137 BT137-500D TRIAC TAG 97
Text: PHILIPS INTERNATIONAL bSE D B 711002t. DDtiEEbl 27b HIPHIN BT 137 SERIES y v. TRIACS , recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the , BT137 series F lH < 20 20 20 20 mA ' L < 30 45 30 45 piA !GT > 10 10 10 25 mA BT 137 series E l|H , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF 711002t. BT137- BT137G 711002b 00bS271 BT137 M1641 BT137F D8573 M1641 TRIAC BT137 CIRCUITS TRIAC TAG 91 TRIAC TAG 626 400 bt137* soldering iron temperature control triac BT 137 BT137-500D TRIAC TAG 97
1995 - BT 130 triac

Abstract: triac BT 16 rating BTA16-600b application motor control BTA26-600B diagram BTa16-600bw application motor control ac motor triac bta12 circuit diagram triac BT 130 BTA16-600B heating control diagram ac motor triac bta16 circuit diagram microwave oven transformer
Text: operation we recommend : BZW04376B or BT . for a 400 V triac (110 VAC mains) we propose a BZW04188B , obtained with a 50/60 Hz transformer. The power supplied to the oven is controlled by a triac in series with the primary (fig.1). Figure 1 : Magnetron power supply controlled by a triac . HV AC 1 , state ! To reduce the stresses at every switching on the circuit and particularly on the triac it is , (continous rating) B Saturation induction BS Bmax = 2 Bn - Br. In the circuits controlled by a triac


Original
PDF
triac BT 137

Abstract: BT137 BT137 application note BT137 Series E BT 137 triac triac BT137 triac BT 137 800 btb 137 TRIAC TAG 137 BT137-500D
Text: , industrial and domestic heating control and static switching systems. QUICK REFERENCE DATA BT 137-500 600 , Non-repetitive peak on-state current; BT 137 -500 600 700 800 VDSM max. 500* 600* 700* 800 V VDRM max. 500 , . "Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose control


OCR Scan
PDF BT137 triac BT 137 BT137 application note BT137 Series E BT 137 triac triac BT137 triac BT 137 800 btb 137 TRIAC TAG 137 BT137-500D
working triac bt136

Abstract: BT136 temperature control by triac BT136 triac bt136 TRIAC bt136 500d of TRIAC BT136 triac BT 136 triac bt136 characteristics lighting control by triac BT136 bt136 triac
Text: System (IEC 134). Voltages (in either direction) BT 136-5 00 600 700 800 Non-repetitive peak , triac may switch into the on-state. The rate of rise of on-state current should not exceed 3 A//vs , T2+ G+ BT136 series bt 136 series G BT136 series F BT136 series E BT136—500D/600D GT H L , the triac may lose control. Therefore the overload should be terminated by a separate protection , triac may temporarily lose control following the surge


OCR Scan
PDF D027173 BT136 BT136-500 D0E71Ã BT136F d8673 working triac bt136 temperature control by triac BT136 triac bt136 TRIAC bt136 500d of TRIAC BT136 triac BT 136 triac bt136 characteristics lighting control by triac BT136 bt136 triac
TAG 84 triac

Abstract: triac BT 140 TRIAC BT 139 TRIAC TAG 90 bt139 BT139G TRIAC TAG 96 bt139 Application M1646 triac BT 147
Text: ) BT 139- -500 600 700 800 Non-repetitive peak off-state voltage (t< 10 ms) VDSM max. 500* 600* 700 , *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , open circuit 1.6 bt 139 series dVD/dt < 100 V/MS bt139 series G dVD/dt < 200 V/MS bt139 series F , the triac may lose control. Therefore the overload should be terminated by a separate protection , \ / \ """ \ / \ / t'me s the triac may temporarily lose


OCR Scan
PDF 711002b BT139 220AB BT139- TAG 84 triac triac BT 140 TRIAC BT 139 TRIAC TAG 90 BT139G TRIAC TAG 96 bt139 Application M1646 triac BT 147
triac bt 12

Abstract: bt136 TAG 69 triac BT136 AN triac bt 135 s41h BT13 TRIAC TAG 64 dv/TRIAC tag 85 triac BT 06 700
Text: , off-state voltages up to 800 V may be applied w ith ou t damage, but the triac may switch into the on-state , -d lcom/d t = 1,8A/ms; 'T(RM S) = 4 a ; T mb = 85 °C ; gate open c irc u it; V q = v DWMmax BT 136 , 10 10 15 BT136 series G BT136 series F BT136 series E BT 136-500D/600D , conditions the triac may lose control. Therefore the overload should be terminated by a separate protection , rior to surge. The triac may tem porarily lose control follow ing the surge. *TSM Fig,7 O n-state


OCR Scan
PDF 711062b QGbE236 BT136 524fl BT136F D8573 triac bt 12 TAG 69 triac BT136 AN triac bt 135 s41h BT13 TRIAC TAG 64 dv/TRIAC tag 85 triac BT 06 700
BT137-500

Abstract: triac BT 137 8T137 LT12A BT137 bt 137 Triacs bt 137 triac bt 135 TRIAC TAG 137 BT137 application note
Text: voltages up to 800 V may be applied without damage, but the triac may switch into the on-state. The rate of , - G- G+ Latching current (l|_); Vq = 12 V 'gt > 35 35 35 70 mA BT 137 series Ih < 20 , 45 fnA 'GT > 10 10 10 25 mA BT 137 series E Ih < 20 20 20 20 mA ' L < 25 35 25 35 mA 'gt , overload conditions the triac may lose control. Therefore the overload should be terminated by a separate , currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose control following the


OCR Scan
PDF BT137-500 M162G BT137G BT137 BT137F D8573 triac BT 137 8T137 LT12A bt 137 Triacs bt 137 triac bt 135 TRIAC TAG 137 BT137 application note
2013 - Not Available

Abstract: No abstract text available
Text: , 4000K 11.9" (302mm) Dimming: 5% Triac Dimming, 10% 0/1-10V Dimming* Lifetime: Designed to last 50 , on 20L and 30L models, Triac for 120V on 9L and 13L models †See www.cree.com/lighting for , 277V 120 Volts 277 Volts Options 10V Triac DImming* 0/1-10V Dimming* 7.2" (184mm) * Triac available on 9L and 13L, 10V available on 20L and 30L 7" (178mm) Ordering Information â , -13L-27K-120V (SSGCG-WF) Initial Delivered Lumens: 1051 Efficacy: 59.6 Lm/W S/M: 1.2 5%–100% Triac dimming


Original
PDF 660Lumens 1050L, 1700L, 2650L
BT138

Abstract: triacs bt 138 triac bt 135 philips triac TAG BT138G TRIAC TAG e3 BT 138 M1627 triac BT 06 600 triac BT 138
Text: either direction) BT 138- -500 600 700 800 Non-repetitive peak off-state voltage (t< 10 ms) VDSM max , recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the , 711Dö2Eq 0Db52äfi HIB «PHIN BT 138 SERIES J MOUNTING INSTRUCTIONS 1. The device may be soldered directly , exceed 125 °C. During these overload conditions the triac may lose control. Therefore the overload , the triac may temporarily lose control following the surge T; = 120°C prior to surge I


OCR Scan
PDF 0Db22Ã BT138 BT138- 220AB 711002t 0b22cm BT138F triacs bt 138 triac bt 135 philips triac TAG BT138G TRIAC TAG e3 BT 138 M1627 triac BT 06 600 triac BT 138
2004 - triacs bt 16 600v

Abstract: BTA16-600b application motor control BTa16-600bw application motor control BTA26-600B diagram triacs bt 12 600v ac motor triac bta12 circuit diagram BTA16-600B heating control diagram triac RC snubber circuit diagram induction heating ac motor triac bta16 circuit diagram
Text: : BZW04376B or BT . for a 400V triac (110 VAC mains) we propose a BZW04188B. SUMMARY Transformer control , power supplied to the oven is controlled by a triac in series with the primary (see Figure 1). Current , stresses at every switching on the circuit and particularly on the triac it is important to limit the , . Magnetron power supply controlled by a triac AC HV REV. 2 May 2004 1/12 AN441 APPLICATION , P In the circuits controlled by a triac , switching OFF occurs when the current is at zero. Thus


Original
PDF AN441 triacs bt 16 600v BTA16-600b application motor control BTa16-600bw application motor control BTA26-600B diagram triacs bt 12 600v ac motor triac bta12 circuit diagram BTA16-600B heating control diagram triac RC snubber circuit diagram induction heating ac motor triac bta16 circuit diagram
Supplyframe Tracking Pixel