The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
PMP8012 Texas Instruments TPS92310 - 220VAC, 8W Isolated , Triac dimmable
PMP6002 Texas Instruments TRIAC Dimmable 120V LED Lighting Driver Controller (32V@350mA)
LM3445-REF Texas Instruments 230 Vac Off-line Triac Dimmer Retrofit with 6 LEDs Reference Design
LM3497MM/NOPB Texas Instruments LM3497 Triac Dimmable Offline LED Driver 10-MSOP
LM3497M/NOPB Texas Instruments LM3497 Triac Dimmable Offline LED Driver 14-SOIC
PMP6003 Texas Instruments TRIAC Dimmable 230V LED Lighting Driver Controller (32V@350mA)

TRIAC BTA 70 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2004 - TRIAC BTA 12

Abstract:
Text: triac IL current. Example: BTA 12 600CC: IL typ (QI and III) = 20mA thus IT = 500mA ­ if the IH , Standard triac 12 Arms (C type) 1.2 Example 2: BTA 06 600T: if IH + = 4.3mA, IH ­ = 3.8mA. BTA 12 , Figure 7). 5/10 AN302 APPLICATION NOTE Example: Triac TO 220, type BTA 12 600C, IH = 20mA at Tj , : standard triac e.g. BTA 12 600B IGT (QI) 50mA IH + 15mA G T2: sensitive triac e.g. BTA 12 600B , introduced a new triac , BTA 06 400 GP, now available for the designers. Its low holding current, specified


Original
PDF AN302 TRIAC BTA 12 TRIAC BTA 02 BTA triac LC filter dimmer Triac triac applications circuit diagram triac BTA 80 BTA 12 and TLS 106-6 TRIAC BTA 400 TRIAC BTA 6 bta 600b
2005 - TRIAC BTA 28

Abstract:
Text: BTA /BTB12 and T12 Series 12A TRIACS TO-220AB Insulated (BTA12) TO-220AB (BTB12) MAIN , 5 to 50 mA DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB12 and T12 triac series is suitable for general purpose AC switching. They can be used as an ON/OFF , versions ( BTA /BTB.W and T12 series) are specially recommended for use on inductive loads, thanks to , power drivers such as microcontrollers. By using an internal ceramic pad, the BTA series provides


Original
PDF BTA/BTB12 O-220AB BTA12) O-220AB BTB12) BW/CW/T1235) BW/CW/T1235 TRIAC BTA 28 TRIAC BTA 16 Triac BTB12 600 B TRIAC BTa 12 600 BW TRIAC BTA 02 Triac BTA 12A 600 V TRIAC BTa 16 600 B TRIAC BTA 16 600 BW TRIAC BTa 24 BTA 600 12 triac
2004 - TRIAC BTB 12.600

Abstract:
Text: low (e.g: P 10 W and the triac BTA 12.400 B) to impose a sufficient current (shown in dotted lines , current IG. The triac does not conduct. A BTA 12.400 B triac is used to control the flashing of a 10 W , advisable. Example: BTA 12.600 C IGT max (Q IV) = 50mA therefore IG = 60 mA In the case of a triac , there , the components. The study will be based on the triac . The points treated are valid for thyristors (except for the various conduction modes). DEFINITION The latching current, IL, of a triac is the


Original
PDF AN303 TRIAC BTB 12.600 triac firing pulse generating circuit triac BTA 12-400 TRIAC BTB 16.600 HOLDING CURRENT TRIAC BTA 12,600B triacs BTA 06.600 T triac diac applications circuit diagram triac arc control TRIAC BTA 12 firing circuit of triac using diac 220v
2002 - TRIAC BTA 28

Abstract:
Text: DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , 3/10 BTA /BTB08 and T8 Series ORDERING INFORMATION BT A 08 - 600 BW (RG) TRIAC , BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series , . By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS


Original
PDF BTA/BTB08 TRIAC BTA 28 TRIAC BTB08 triac BTA 32 600 TRIAC BTB08 specifications TRIAC BTB08 600 TRIAC BTa 24 TRIAC BTa 18 600 B BTA 600 bta 03 BTA 36
2008 - LC filter dimmer Triac

Abstract:
Text: ) 0.9 (approx.) Standard TRIAC 12 Arms (C type) 1.8 (approx.) Example: BTA /BTB06-600TW: if IH , TRIAC for high sensitivity with high holding current T1: standard triac e.g. BTA /BTB12 -600B: I GT = 50mA IH = 50mA T2: sensitive triac e.g. BTA /BTB12 -600TW: I GT = 5mA IH = 10mA 2.3 Combining , only the TRIAC ; however, the concepts are also valid for SCRs. Definition To keep an , current falls too low the relay would turn off. The same phenomenon can be observed in a TRIAC . This


Original
PDF AN302 LC filter dimmer Triac triac 220v light dimmer triac 220v light dimmer filter coil Triac based temperature control circuit all types of triac 220v light dimmer light sensitive trigger circuit Application how to test triac TRIAC TESTER bta 600b
2000 - bta 16 600 D

Abstract:
Text: -220AB package 3/10 BTA /BTB08 and T8 Series ORDERING INFORMATION BT A 08 - 600 BW TRIAC , BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM , LOGIC LEVEL & STANDARD MAIN , A2 DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is suitable for general purpose AC switching. They can be used as an ON/OFF function in , control operation in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W


Original
PDF BTA/BTB08 bta 16 600 D triac BT 130 BTB108-xxxBW TRIAC BTA 28 triac BTA 32 600 TRIAC BTa 18 600 B TRIAC BTB08 TRIAC BTA 06 400 G BTA08 ST bta 06 400 v
1995 - triac TIC

Abstract:
Text: 6 Arms (T type) 3 Standard triac 12 Arms(C type) 1.5 Example 1 : BTA 06 600T : if IGT , Sensitive triac 6 Arms (T type) 1.2 Standard triac 12 Arms (C type) 1.2 Example 2 : BTA 06 600T , junction temperature in accordance with an analog law (see figure 9). Example : Triac TO 220, type BTA , a High Sensitivity with a High Hypostatic Current. T1 : standard triac e. g. BTA 12 600B IGT , has introduced a new triac , BTA 06 400 GP, now available for the designers. Its low holding current


Original
PDF
2001 - TRIAC BTa 18 600 BW

Abstract:
Text: DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , 3/10 BTA /BTB08 and T8 Series ORDERING INFORMATION BT A 08 - 600 BW TRIAC SERIES , BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series , . By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS


Original
PDF BTA/BTB08 TRIAC BTa 18 600 BW TRIAC BTB 16 600 BW BT 136 TRIAC triac BT 140 BTB108-xxxBW TRIAC BTA 28 TRIAC BTB08 specifications T810 BTA 600 triac triac BTA 140
TRIAC BTa 12 600

Abstract:
Text: ) BTA06-600CW 240 110 BTA 06 600 CW BTA 08 400 CW 1,000 The choice of the Triac is , TO RESISTIVE SENSOR SENSOR FILTER AM PLIFIER PR O G RAM M ABLE ON-TIM ER TRIAC O U TPUT AND RELAY , integrated circuit in­ tended to control triac or relay switch for ACmains tim er applications.The device , 2 V 8 mA 4 1 Itout Triac Firing C urrent 5 50 65 VzCD Zero C , ontinue 14/4 Delay Tim e Between Tim er Stop to Retrigger It o l Triac Output Leakage Current


OCR Scan
PDF UAA4713 DIP-14 SO-14 UAA4713DP UAA4713FP UAA4713 X10FL EI00S LDR07 100nF/35V TRIAC BTa 12 600 triac BTA 140 triac BTA 80 BTA 51 triac LDR07 TRIAC BTA 06 400 TRIAC BTA 08 600 D TRIAC BTa 10 600 B TRIAC BTA 36
2003 - bta 8a 600v

Abstract:
Text: DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series , . By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS , temperature range December 2003 - Ed: 6A 1/10 BTA /BTB08 and T8 Series ELECTRICAL CHARACTERISTICS


Original
PDF BTA/BTB08 bta 8a 600v TRIAC BTA 28 TRIAC BTA 20 600 BW triac bt 24 600v TRIAC BTA-SERIES T835 T810 BTB08 triacs bt 25 600v triac BTA 32 600
2002 - Not Available

Abstract:
Text: surface-mount packages, the BTA /BTB12 and T12 triac series is suitable for general purpose AC switching. They , BTA /BTB12 and T12 Series ® 12A TRIACS SNUBBERLESS™, LOGIC LEVEL & STANDARD MAIN , controllers,. The snubberless versions ( BTA /BTB.W and T12 series) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA , + 100 1/7 BTA /BTB12 and T12 Series ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise


Original
PDF BTA/BTB12
2002 - TRIAC BTA 28

Abstract:
Text: either in through-hole of surface and T25 mount packages, the BTA /BTB24-25-26 triac series is suitable , in TOP3 3/9 BTA /BTB24, BTA25, BTA26 and T25 Series T 25 35 - 600 G (-TR) TRIAC , BTA /BTB24, BTA25, BTA26 and T25 Series ® 25A TRIACS SNUBBERLESSTM & STANDARD MAIN , versions ( BTA /BTB.W and T25 series) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA series provides


Original
PDF BTA/BTB24, BTA25, BTA26 O-220AB BTB24) TRIAC BTA 28 TRIAC BTB T25 ac motor triac bta25 triac bt 151 triac BTA 32 600 triac TOP3 25a 800V triac bt 24 600v triac BT 408 TRIAC BTB 16 600 BW TRIAC BTA 4000
2002 - triacs bt 16 600v

Abstract:
Text: or surface-mount packages, the BTA /BTB16 and T16 triac series is suitable for general purpose AC , BTA /BTB16 and T16 Series ® 16A TRIACS SNUBBERLESSTM , LOGIC LEVEL & STANDARD MAIN , speed controllers, . The snubberless versions ( BTA /BTB.W and T16 series) are specially , ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL , °C + 100 1/7 BTA /BTB16 and T16 Series ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless


Original
PDF BTA/BTB16 triacs bt 16 600v triac BTA 32 triac BTA 140 triac BTA 32 600 triacs bt 16a 600v TRIAC BTa 18 600 BW TRIAC BTA series circuit triac btb16 BT 130 triac TRIAC BTa 16 600 BW
2002 - BTA12

Abstract:
Text: surface-mount packages, the BTA /BTB12 and T12 triac series is suitable for general purpose AC switching. They , BTA /BTB12 and T12 Series ® 12A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN , controllers,. The snubberless versions ( BTA /BTB.W and T12 series) are specially recommended for use on , BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL standards (File ref , °C + 100 1/7 BTA /BTB12 and T12 Series ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless


Original
PDF BTA/BTB12 BTA12 BTA 136 600 BT 130 triac TRIAC BTA series triac BTA 32 600 bta 12a 600v Triac BTA 12A 600 V TRIAC BTA 28 bta12 triac induction motor control TRIAC BTa 12 600
2002 - triac BTA 32 600

Abstract:
Text: either in through-hole of surface and T25 mount packages, the BTA /BTB24-25-26 triac series is suitable , BTA /BTB24, BTA25, BTA26 and T25 Series ® 25A TRIACS SNUBBERLESSTM & STANDARD MAIN , versions ( BTA /BTB.W and T25 series) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA series provides , W - 40 to + 150 - 40 to + 125 °C + 100 1/9 BTA /BTB24, BTA25, BTA26 and T25 Series


Original
PDF BTA/BTB24, BTA25, BTA26 O-220AB BTB24) triac BTA 32 600 TRIAC BTA 28 triac bta26 triac BTA 32 triac BTA 140 triac bt 160 600v TRIAC BTA 4000 TRIAC BTA 20 600 BW BTA 600 12 triac T25 Series
1995 - TRIAC BTB 12.600

Abstract:
Text: of the gate current IG. The triac does not conduct. A BTA 12.400 B triac is used to control the , , that is, a triac whose latching current IL in the first quadrant is equal to 70 mA. His triac will , the components. The study will be based on the triac . The points treated are valid for thyristors (except for the various conduction modes). DEFINITION The latching current, IL, ofa triac is the , : Controlled by the gate pulse, IG, the triac is fired, and a current IT flows through it, imposed by the main


Original
PDF
2000 - BT 130 triac

Abstract:
Text: surface-mount packages, the BTA /BTB12 and T12 triac series is suitable for general purpose AC switching. They , BTA /BTB12 and T12 Series ® 12A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN , controllers,. The snubberless versions ( BTA /BTB.W and T12 series) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA , 125°C 4 A Tj = 125°C 1 W - 40 to + 150 - 40 to + 125 °C + 100 1/7 BTA


Original
PDF BTA/BTB12 BT 130 triac TRIAC BT 136 BT 126 TRIAC BT 136 TRIAC triacs bt 12 600v T1235 T12-G triacs bt 16 600v bta12 speed control application BTA12 600
2000 - triacs bt 12 600v

Abstract:
Text: surface-mount packages, the BTA /BTB12 and T12 triac series is suitable for general purpose AC switching. They , BTA /BTB12 and T12 Series ® 12A TRIACS SNUBBERLESSTM , LOGIC LEVEL & STANDARD MAIN , controllers,. The snubberless versions ( BTA /BTB.W and T12 series) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA , 125°C 4 A Tj = 125°C 1 W - 40 to + 150 - 40 to + 125 °C + 100 1/7 BTA


Original
PDF BTA/BTB12 triacs bt 12 600v bt 1690 BT 130 triac BT 126 TRIAC BTA12 600V t 935 T1235 BTA12 W80D BTB12
2005 - triac BTA 32 600

Abstract:
Text: -220AB insulated BTA16 Features ■Medium current Triac ■Low thermal resistance with clip bonding ■Low thermal resistance insulation ceramic for insulated BTA ■High commutation (4Q) or very high commutation (3Q) capability ■BTA series UL1557 certified (File ref: 81734) ■RoHS ( 2002/95/EC) compliant ■TO-220AB BTB16 Insulated tab ( BTA series, rated at 2500 VRMS) D2PAK T1635G T1610G Applications ■■A2 Snubberless versions ( BTA


Original
PDF BTA16, BTB16 T1610, T1635 O-220AB BTA16 UL1557 2002/95/EC) triac BTA 32 600 circuit triac btb16 BTA16 TRIAC BTA 02 TRIAC BTa 18 600 B
2001 - BT 130 triac

Abstract:
Text: DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB12 and T12 triac series is , 35 50 60 500 6.5 50 70 80 1000 12 V/µs A/ms BTA /BTB12 CW 35 BW 50 mA V V mA mA Unit VD = VDRM RL = , ® BTA /BTB12 and T12 Series 12A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T12 series) are , internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL


Original
PDF BTA/BTB12 BT 130 triac BT 126 TRIAC triacs bt 12 600v triac BTA 32 600 bt 1690 triac BTA12 triacs bt 12 800v
2000 - TRIAC BTA 28

Abstract:
Text: DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , 3/10 BTA /BTB08 and T8 Series ORDERING INFORMATION BT A 08 - 600 BW TRIAC SERIES , BTA /BTB08 and T8 Series ® 8A TRIACS SNUBBERLESSTM, LOGIC LEVEL & STANDARD MAIN FEATURES , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series , . By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS


Original
PDF BTA/BTB08 TRIAC BTA 28 BTA 600 12 triac triac bt 24 600v TRIAC BTB08 specifications TRIAC BTB 16 600 tube triac BTA 140 triac BT 16 rating TRIAC BTA-SERIES TRIAC BTB 04 T810-xxxH
triac bt 24 600v

Abstract:
Text: DESCRIPTION Available either in through-hole or surface-mount packages, the BTA /BTB08 and T8 triac series is , -220AB package 3/10 BTA /BTB08 and T8 Series ORDERING INFORMATION BT A 08 - 600 BW TRIAC , BTA /BTB08 and T8 Series 8A TRIACS SNUBBERLESS , LOGIC LEVEL & STANDARD MAIN FEATURES , in light dimmers, motor speed controllers,. The snubberless versions ( BTA /BTB.W and T8 series , . By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS


Original
PDF BTA/BTB08 triac bt 24 600v TRIAC BTA 28 TRIAC BTB08 specifications TRIAC BTB08 600 TRIAC BTA series TRIAC BTa 24 TRIAC BTB 24 600 BW TRIAC BTB08 triac BTA 140 specifications of TRIAC BTB08
2000 - triacs bt 16 600v

Abstract:
Text: surface-mount packages, the BTA /BTB16 and T16 triac series is suitable for general purpose AC switching. They , BTA /BTB16 and T16 Series ® 16A TRIACS SNUBBERLESSTM , LOGIC LEVEL & STANDARD MAIN , controllers, . The snubberless versions ( BTA /BTB.W and T16 series) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA , 125°C 4 A Tj = 125°C 1 W - 40 to + 150 - 40 to + 125 °C + 100 1/7 BTA


Original
PDF BTA/BTB16 triacs bt 16 600v TRIAC BTA 28 TRIAC BT 136 triacs bt 16a 600v TRIAC BTa 12 600 triac bt 160 600v T1635 TRIAC BTA series circuit triac btb16 BTB16-XXXBW
2001 - triacs bta 100 600v

Abstract:
Text: Available either in standard or snubberless version, the BTA /BTB10 triac series is suitable for general , ® BTA /BTB10 Series 10A TRIACS SNUBBERLESSTM & STANDARD MAIN FEATURES: Symbol IT(RMS , inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA , 4 1 - 40 to + 150 - 40 to + 125 October 2001 - Ed: 4 BTA /BTB10 Series ELECTRICAL , Quadrant BTA /BTB10 CW IGT (1) VGT VGD IH (2) IL dV/dt (2) (dI/dt)c (2) VD = 12 V VD = VDRM IT = 500 mA IG =


Original
PDF BTA/BTB10 triacs bta 100 600v TRIAC BTA series BTA 600 12 triac BTB10-XXXB TRIAC BTa 18 600 BW TRIAC BTa 18 600 B TRIAC BTA 70 bta 12 600v Triac BTB 06 600 A1A2G
2002 - triac BT 408

Abstract:
Text: , the BTA /BTB24-25-26 triac series is suitable for general purpose AC power switching. They can be used , Tj = 125°C I - II - III I - II - III I - II - III MAX. MAX. MIN. MAX. MAX. 50 70 80 500 13 35 BTA /BTB , ® BTA /BTB24, BTA25, BTA26 and T25 Series 25A TRIACS SNUBBERLESS TM & STANDARD MAIN , , soft start circuits.The snubberless versions ( BTA /BTB.W and T25 series) are specially recommended , ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL


Original
PDF BTA/BTB24, BTA25, BTA26 BTA/BTB24-25-26 triac BT 408 triac bt 24 600v TRIAC BTA 4000 triac bt 151 triac TOP3 25a 800V TRIAC BTA 28 triac BTA 32 600 TRIAC btb24 RD91 triac TRIAC BTB 24 600 BW
Supplyframe Tracking Pixel