The Datasheet Archive

SF Impression Pixel

Search Stock (6)

  You can filter table by choosing multiple options from dropdownShowing 6 results of 6
Part Manufacturer Supplier Stock Best Price Price Each Buy Part
STPM01FTR STMicroelectronics Avnet - $1.29 $1.29
STPM01FTR STMicroelectronics Newark element14 2,483 $3.47 $1.56
STPM01FTR STMicroelectronics Future Electronics - $1.35 $1.35
STPM01FTR STMicroelectronics Chip1Stop 2,385 $2.12 $1.53
STPM01FTR STMicroelectronics element14 Asia-Pacific 2,483 $3.69 $1.87
STPM01FTR STMicroelectronics Farnell element14 2,483 £2.14 £1.58

No Results Found

Show More

STPM01 datasheet (4)

Part Manufacturer Description Type PDF
STPM01 STMicroelectronics PROGRAMMABLE SINGLE PHASE ENERGY METERING IC WITH TAMPER DETECTION Original PDF
STPM01FTR STMicroelectronics PMIC - Energy Metering, Integrated Circuits (ICs), IC ENERGY METER 1 PHASE 20TSSOP Original PDF
STPM01FTR STMicroelectronics Programmable single phase energy metering IC with tamper detection Original PDF
STPM01FTR STMicroelectronics PROGRAMMABLE SINGLE PHASE ENERGY METERING IC WITH TAMPER DETECTION Original PDF

STPM01 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2008 - UM0509

Abstract: p112 opto M74HC126 CN10 STR710 TP10 STPM01 USB 2.0 - SPI Flash Programmer schematic opto P113 LD1085-18
Text: 3.3V 5V +5V STPM01_SCS STPM01_SDA STPM01_SCLK STPM01_SYN P1.0 P1.1 P1.2 SPI_BUFFER , STR7_OTP_EN STPM01_SCS STPM01_SDA STPM01_SCL STPM01_SYN +5V0 CHARGE PUMP Figure 7. DEBUG , STPM01_SCS STR7_SBG STPM01_SCL STPM01_SDA GND 10n C38 10n C37 10n C35 3 3 Q3 BC807-25 VOTP STPM01_SYN STR7_OTP_EN STR7_SBS STPM01_SCS STR7_SBG STPM01_SCL STPM01_SDA GND , STR7_MOSI STPM01_SDA STR7_SCS STPM01_SCS 5V R41 4.7k 3.3V STR7_WRITE_EN rev


Original
PDF UM0509 STEVAL-IPE005V1, STPM01 STR710 UM0509 p112 opto M74HC126 CN10 TP10 USB 2.0 - SPI Flash Programmer schematic opto P113 LD1085-18
2005 - energy meter ic 0038

Abstract: STPM01FTR STPM01 crossing kwh meter pln convert 230v adc to 5v dc without using transform rogowski coil integrator pst 39 transformer zero crossing detector ic with 230v
Text: configure the STPM01.This means that STPM01 can retain 56 bits of information even if it has been unsupplied , 56 bits are used for configuring and programming the STPM01. 21/42 STPM01 Figure 20: STPM01 , STPM01 PROGRAMMABLE SINGLE PHASE ENERGY METERING IC WITH TAMPER DETECTION I I I I I , TSSOP DESCRIPTION The STPM01 is designed for effective measurement of active, reactive and apparent , microcontroller based 1-phase or 3-phase energy meter. The STPM01 consists, essentially, of two parts: the analog


Original
PDF STPM01 IEC62052-11, IEC62053-2X STPM01 energy meter ic 0038 STPM01FTR STPM01 crossing kwh meter pln convert 230v adc to 5v dc without using transform rogowski coil integrator pst 39 transformer zero crossing detector ic with 230v
2006 - STPM01FTR

Abstract: transformer pst 39
Text: STPM01 Programmable single phase energy metering IC with tamper detection Feature summary , of bits of internal OTP. In the STPM01 an output signal with pulse frequency proportional to energy , configuration bit. TSSOP20 Description The STPM01 is designed for effective measurement of active, reactive , a microcontroller based 1-phase or 3-phase energy meter. The STPM01 consists, essentially, of two , Order code Part number STPM01FTR October 2006 Temperature range -40 to 85 °C Package TSSOP20 (Tape &


Original
PDF STPM01 IEC62052-11, IEC620532x STPM01FTR transformer pst 39
2008 - stm32 spi

Abstract: AN2799 IEC62052-11 STPM01 STM32 schematic STM32F103RBT6 reference manual stm32f103xx energy meter calibration stpm01 "single phase with shunt" STM32F103RBT6 STM32
Text: sensor. The following list is a brief description of the main features of the STPM01. For more details , . Figure 2 shows a reference schematic to interface the STM32x microcontroller with the STPM01. The STPM01 , configuration registers of the STPM01. ReadRegisters: this function reads the registers from the STPM01 , signals specific for an STPM01. In detail, the STM32 GPIO is used as the SCS for the specific device. The , AN2799 Application note Measuring mains power consumption with the STM32x and STPM01


Original
PDF AN2799 STM32x STPM01 STM32x STPM01 AM00076v1 stm32 spi AN2799 IEC62052-11 STM32 schematic STM32F103RBT6 reference manual stm32f103xx energy meter calibration stpm01 "single phase with shunt" STM32F103RBT6 STM32
2007 - schematic diagram of energy saving device

Abstract: zero crossing detector 50Hz 230v ci DT 8211 zero crossing detector ic with 230v STPM01FTR Rogowski 110v to 5v dc schematic step down transformer to convert 230v to 20v schematic diagram for ac line voltage monitor anti tamper AND destroy
Text: STPM01 Programmable single phase energy metering IC with tamper detection Feature summary , Description The STPM01 is designed for effective measurement of active, reactive and apparent energy in a , 1-phase or 3-phase energy meter. The STPM01 consists, essentially, of two parts: the analog part , internal OTP. In the STPM01 an output signal with pulse frequency proportional to energy is generated , . Order code Part number Temperature range Package Packaging STPM01FTR -40 to 85 °C


Original
PDF STPM01 TSSOP20 IEC62052-11, IEC620532x STPM01 schematic diagram of energy saving device zero crossing detector 50Hz 230v ci DT 8211 zero crossing detector ic with 230v STPM01FTR Rogowski 110v to 5v dc schematic step down transformer to convert 230v to 20v schematic diagram for ac line voltage monitor anti tamper AND destroy
2010 - STPM01FTR

Abstract: energy meter ic 0038 zero crossing detector 50Hz 230v AN2317 STPM01 Rogowski Coil design IEC62052-11 calibration stpm01 "single phase with shunt" AN2299 mb1060
Text: STPM01 Programmable single phase energy metering IC with tamper detection Features Active , V and 30 ppm/°C max Description The STPM01 is designed for effective measurement of active , measurement in a microcontroller based monophase or 3-phase energy meter. The STPM01 consists, essentially , permanent programming of bits of internal OTP. In the STPM01 an output signal with pulse frequency , STPM01FTR - 40 to 85 °C TSSOP20 (tape and reel) 2500 parts per reel October 2010 Doc ID 10853


Original
PDF STPM01 IEC62052-11, IEC620532x STPM01 STPM01FTR energy meter ic 0038 zero crossing detector 50Hz 230v AN2317 Rogowski Coil design IEC62052-11 calibration stpm01 "single phase with shunt" AN2299 mb1060
2010 - rogowski coil analog integrator

Abstract: Rogowski Coil design IEC standard for Rogowski Coil rogowski coil integrator Rogowski Coil STPM10 AN3306 IEC 62053-22 Rogowski Coil application Rogowski
Text: demonstration board with the STPM01 and the Pulse current sensor. The results obtained from the accuracy testing conducted with the STPM01 can be considered valid for all devices in the STPMxx family that share , . Block diagram of a Rogowski coil-based application with the STPM01 AM00178v1 a. Excludes only the , with the STPM01 . . . . . . . . . . 14 7 Accuracy results . . . . . . . . . . . . . . . . . . . . , coil-based application with the STPM01 . . . . . . . . . . . . . . . . 1 Rogowski coil principle . . . . . .


Original
PDF AN3306 rogowski coil analog integrator Rogowski Coil design IEC standard for Rogowski Coil rogowski coil integrator Rogowski Coil STPM10 AN3306 IEC 62053-22 Rogowski Coil application Rogowski
2011 - Not Available

Abstract: No abstract text available
Text: STPM01 Programmable single phase energy metering IC with tamper detection Features I Active , voltage reference: 1.23 V and 30 ppm/°C max TSSOP20 Description The STPM01 is designed for , STPM01 consists, essentially, of two parts: the analog part and the digital part. The former, is , permanent programming of bits of internal OTP. In the STPM01 an output signal with pulse frequency , Package Packaging STPM01FTR - 40 to 85 °C TSSOP20 (tape and reel) 2500 parts per reel


Original
PDF STPM01 IEC62052-11, IEC620532x TSSOP20 STPM01
2010 - STPM10

Abstract: rogowski coil analog integrator rogowski coil integrator STPM01-10 AN2159 kwh meter circuit diagram energy meter codes STPM01 SPI CONVERT Rogowski Coil design
Text: description The STPM01-10 SPI interface supports a simple serial protocol, which is implemented in order to , AN2159 Application note SPI protocol for STPM01 /STPM10 metering devices Introduction The STPM01 , . STPM10 is dedicated for peripheral use only in microcontroller based applications, while STPM01 is able , application note describes the SPI protocol to read measured data from STPM01 and STPM10 in a single-phase , . . . . . 3 1.1 1.2 2 STPM01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Original
PDF AN2159 STPM01/STPM10 STPM01 STPM10 rogowski coil analog integrator rogowski coil integrator STPM01-10 AN2159 kwh meter circuit diagram energy meter codes SPI CONVERT Rogowski Coil design
2004 - calibration stpm01 "single phase with shunt"

Abstract: STPM01 vip 504 62053-2X
Text: STPM01 PROGRAMMABLE SINGLE PHASE ENERGY METERING IC WITH TAMPER DETECTION PRELIMINARY DATA s , AND 30 ppm/°C MAX TSSOP20 PACKAGE DESCRIPTION The STPM01 is designed for effective measurement , microprocessor based 1-phase or 3-phase energy meter. The STPM01 consists, essentially, of two parts: the , the STPM01 the calibration is very easy: an output signal with pulse frequency proportional to , : Order Codes Type Temperature Range Package Comments STPM01 -40 to 85 °C TSSOP20


Original
PDF STPM01 62053-2X TSSOP20 STPM01 calibration stpm01 "single phase with shunt" vip 504
2009 - STPM01FTR

Abstract: 06-Feb-2006 STPM01 crossing
Text: STPM01 Programmable single phase energy metering IC with tamper detection Features , temporary or permanent programming of bits of internal OTP. In the STPM01 an output signal with pulse , mode or changing any configuration bit. TSSOP20 Description The STPM01 is designed for effective , peripheral measurement in a microcontroller based monophase or 3-phase energy meter. The STPM01 consists , Temperature range - 40 to 85 °C Order code STPM01FTR Package TSSOP20 (tape and reel) Packaging 2500


Original
PDF STPM01 IEC62052-11, IEC620532x STPM01FTR 06-Feb-2006 STPM01 crossing
2006 - AN2159

Abstract: STPM01 Block diagram of DSP based Power meter STPM01SPIRead 0xF0000 SPI EEPROM algorithm flow diagram Three Phase Power Energy SPI air dmv hlt nv process flow diagram of energy meters M95256
Text: =0, badparity_DMV=0, badparity_CFL=0, badparity_CFH=0; u8 STPM01_ReadOK =0, STPM01_ck1 = 0, STPM01_ck2 = 0 , ); if ( STPM01_ck1 && STPM01_ck2 ) && (STPM_First.DAP = STPM_Second.DAP) && (STPM_First.DRP = , registers read from STPM01 ­ subtask_5: if OK process STPM01's status ­ subtask_6: if OK compute , STPM01SPIRead (); pSTPM_Reading->CFH=new_dwdata; } subtask_2 /*Subtask 2*/ STPM01_Get_Register (&STPM_Second , STPM01_Check_Data (); STPM01Stop (); if (!check_OK) subtask_count=subtask_max


Original
PDF AN2159 STPM01 STPM01 AN2159 Block diagram of DSP based Power meter STPM01SPIRead 0xF0000 SPI EEPROM algorithm flow diagram Three Phase Power Energy SPI air dmv hlt nv process flow diagram of energy meters M95256
2005 - STPM01

Abstract: UM0128 shunt release coil function lvs1
Text: . 3/21 UM0128 - USER MANUAL 4/21 UM0128 USER MANUAL STPM01- QUICK APPLICATION USER , MANUAL 8 - APPENDIX A 8.1 - Writing data The user can also write data bits in STPM01. Refer to the , menu will show up with just one option: Write. Click this option to write the selected bit in STPM01. , the operating mode by reading data from STPM01. Select all data bits you want to write in STPM01 and , to the STPM01. The high voltage source is selected from: Figure 11 : Write to OPT Button 8.5 -


Original
PDF STPM01 UM0128 STPM01 shunt release coil function lvs1
2008 - Not Available

Abstract: No abstract text available
Text: STPM01_SCS STPM01_SDA STPM01_SCLK STPM01_SYN P1.0 P1.1 P1.2 SPI_BUFFER POWER MANAGEMENT RESET , ChargePump GND STR7_SBG STR7_SBS STR7_OTP_EN STPM01_SCS STPM01_SDA STPM01_SCL STPM01_SYN , STR7_OTP_EN STR7_SBS STPM01_SCS STR7_SBG STPM01_SCL STPM01_SDA GND 3 1 bs O let o 2 P e , STPM01_SCLK U14 )(s 1 2 3 4 5 6 7 ct u 5V od r 5V GND STR7_MOSI STPM01_SDA , VCC C30 STR7_SBG STPM01_SCL C36 56p STPM01_SYN 1 2 3 4 5 6 7 VCC 6A 6Y 5A


Original
PDF STEVAL-IPE005V1 STPM01 STPM01 STR710
2008 - LD1085-33

Abstract: M74HC126 P112 opto LD1085-18 V334 STR710FZ2T6-TQFP144 6-SOT323-6L TP10 STR710 stpm01
Text: 3.3V 5V +5V STPM01_SCS STPM01_SDA STPM01_SCLK STPM01_SYN P1.0 P1.1 P1.2 SPI_BUFFER , STR7_OTP_EN STPM01_SCS STPM01_SDA STPM01_SCL STPM01_SYN +5V0 CHARGE PUMP Figure 1. DEBUG , STR7_OTP_EN STR7_SBS STPM01_SCS STR7_SBG STPM01_SCL STPM01_SDA GND 10n C38 10n C37 10n , STPM01_SY N STR7_SCL STPM01_SCLK 5V read_en read_en3V 1 sda5V 2 miso3V 3 4 5 6 7 1 2 , STR7_MOSI STPM01_SDA STR7_SCS STPM01_SCS 5V R41 4.7k 3.3V STR7_WRITE_EN rev


Original
PDF STEVAL-IPE005V1 STPM01 STPM01 STR710 LD1085-33 M74HC126 P112 opto LD1085-18 V334 STR710FZ2T6-TQFP144 6-SOT323-6L TP10
2009 - STPM01

Abstract: energy meter ic 0038 ci DT 8211 Rogowski Coil design STPM01 crossing IEC62052-11 STPM01FTR 230v ac emi filter
Text: STPM01 Programmable single phase energy metering IC with tamper detection Features Active , V and 30 ppm/°C max Description The STPM01 is designed for effective measurement of active , measurement in a microcontroller based monophase or 3-phase energy meter. The STPM01 consists, essentially , internal OTP. In the STPM01 an output signal with pulse frequency proportional to energy is generated , . Device summary Order code Temperature range Package Packaging STPM01FTR - 40 to 85 °C


Original
PDF STPM01 IEC62052-11, IEC620532x STPM01 energy meter ic 0038 ci DT 8211 Rogowski Coil design STPM01 crossing IEC62052-11 STPM01FTR 230v ac emi filter
2005 - STPM01

Abstract: UM0164 mains clock module 324PM
Text: ): http://www.st.com/interface/ ( STPM01-324PM Kit User Manual, STPM01 Documentation) Figure 1 , ( STPM01-based ) energy meter application. See associated datasheets and technical literature for details about , . . . . . . . . . . . . . . . . . . . . . . . . 9 PC-based STPM01 Programmer Measurement . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3.3 STPM01 Manager , . . . . . . . . . . . . . . . . . . . . 5 STPM01 Programmer . . . . . . . . . . . . . . . . . . . .


Original
PDF UM0164 324PM 324PM STPM01-based) STPM01-324PM STPM01 UM0164 mains clock module
2008 - STPM01

Abstract: multiphase flow meter AN2167
Text: input for the voltage channel of the STPM01. Both voltage pins of the shunt should be connected to the , resolved with components outside of the STPM01. 2.3 Multi-phase application with or without tamper , AN2167 Application note Using the STPM01 with a shunt current sensor Introduction This document describes how a shunt current sensor can be used with the STPM01 metering device in single-phase metering , information on the STPM01 , refer to the full datasheet. October 2008 Rev 2 1/5 www.st.com Theory


Original
PDF AN2167 STPM01 STPM01 multiphase flow meter AN2167
smps 1000W

Abstract: PFC BALLAST CONTROL IC l6562 3000w smps flyback 1000w 1000w buck boost converter 220v DC MOTOR SPEED CONTROLLER smps design 1000w l6562 1000w PFC design l6562 flyback led design 3 phase pfc controller
Text: single phase energy metering IC: STPM01 Mono phase energy meter measurement board energy metering IC: STPM01 Programmable single phase with shunt sensor energy metering IC: STPM01 energy metering IC: STPM01 UM0164 Programmable single phase 2 current transformers and automatic reader , Mono phase energy meter complete solution with STEVAL-IPE004V1 energy metering IC: STPM01 Mono


Original
PDF PSD34XX STEVAL-IFN002V1 32-bit N2115 EVAL6928D EVAL6928Q1 EVAL6932D1 L6928Q1 L6932D1 L6928 smps 1000W PFC BALLAST CONTROL IC l6562 3000w smps flyback 1000w 1000w buck boost converter 220v DC MOTOR SPEED CONTROLLER smps design 1000w l6562 1000w PFC design l6562 flyback led design 3 phase pfc controller
2011 - zero crossing detector 230v

Abstract: rogowski coil analog integrator zero crossing detector 50Hz 230v
Text: STPM01 Programmable single phase energy metering IC with tamper detection Features , the STPM01 an output signal with pulse frequency proportional to energy is generated, this signal is , Description The STPM01 is designed for effective measurement of active, reactive and apparent energy in a , monophase or 3-phase energy meter. The STPM01 consists, essentially, of two parts: the analog part and the , a Table 1. Device summary Temperature range - 40 to 85 °C Order code STPM01FTR June 2011


Original
PDF STPM01 IEC62052-11, IEC620532x zero crossing detector 230v rogowski coil analog integrator zero crossing detector 50Hz 230v
2007 - talking energy KWH meter introduction

Abstract: talking energy meter circuit diagram SCHEMATIC DIAGRAM REVERSE KWH METER three phase wattmeter connections talking energy KWH meter talking energy meter block diagram cera-mite .1m 2kv osram inverter j7 DIODE ZENER 3.3V 1W MELF SMD figure of three phase wattmeter
Text: 1nF C3 8/38 270K 4 R16 2.2M R9 STPM01_TSSOP20 C9 1MY C8 C7 1nF , current input. This prevents cross talking within the STPM01. 1.5 Clock management network 4.194 , STPM01. If an 8 MHz quartz is used, this bit must be changed to 1. Figure 4. Clock management network , for comprehensive energy reading of the STPM01". 3.7 Three-phase energy calculation The above , path because the voltage inputs are normally relatively further from the corresponding STPM01.


Original
PDF AN2512 STPM01, VIPer12A STPM01 VIPer12A talking energy KWH meter introduction talking energy meter circuit diagram SCHEMATIC DIAGRAM REVERSE KWH METER three phase wattmeter connections talking energy KWH meter talking energy meter block diagram cera-mite .1m 2kv osram inverter j7 DIODE ZENER 3.3V 1W MELF SMD figure of three phase wattmeter
2008 - SMD R25

Abstract: 74HC14A Rogowski Coil design 100nF, SMD PC817 TS2431 STPM01 LL4148 CON20 ZMM 16V ST
Text: 270K 4 200K R16 2.2M R9 STPM01_TSSOP20 led MON MOP Vddd Vss Vcc Vdda Votp , STEVAL-IPE008V1 Energy meter (3-phase) demonstration board based on the STPM01 and STR715FR0 , board shows how to design a 3-phase meter using STPM01 as measuring device and a VIPer12ADIP-E as SMPS (switch mode power supply). The STPM01 is a metering ASSP implemented in an advanced 0.35 µm , based single- or 3phase meter. In a standalone configuration STPM01 outputs a pulse train signal having


Original
PDF STEVAL-IPE008V1 STPM01 STR715FR0 VIPer12ADIP-E AM03203v1 STEVAL-IPE008V1 VIPer12ADIP-E SMD R25 74HC14A Rogowski Coil design 100nF, SMD PC817 TS2431 LL4148 CON20 ZMM 16V ST
2011 - STEVAL-IHP003V1

Abstract: tsm0505s 470 uf 25v STEVAL-IHP003V1 circuit schematic STM32F103CBT6 ST7540 reference design TSM0505 DSASW009281 ST7540 SPAC265-3W
Text: L STPM01_SYN STPM01_SCS STPM01_SCK STPM01_MISO STPM01_MOSI PLM SYN_MCU SPI_SCS SPI_CLK SPI_MISO SPI_MOSI ZCR MCO STPM01 MCU Energy Measurement SPAC265-3W Power Supply , JT-TMS OPT_CMD STPM01_SYN USART_RX USART_TX MCO STPM01_MOSI STPM01_MISO STPM01_SCK STPM01_SCS , , and STPM01 Data brief Features Energy consumption monitoring PLM communication , STM32F10x microcontroller, ST7540 PLM, and STPM01 energy metering ICs. The board is a node of a PLM


Original
PDF STEVAL-IHP002V1 STM32, ST7540 STPM01 RS232 STEVAL-IHP002V1 STM32F10x STEVAL-IHP003V1 tsm0505s 470 uf 25v STEVAL-IHP003V1 circuit schematic STM32F103CBT6 ST7540 reference design TSM0505 DSASW009281 SPAC265-3W
2005 - lcd power board schematic

Abstract: STPM01 1N4148 AN2179 ST72324 ST72F324
Text: MC_GND Oscillator STPM01_CON ICP_CLK ICCSEL RESET MC_+5.0V 5.0V LED MC_+5.0V E_LCD , _+5.0V STPM01_CON 4/8 ICCDATA E_EEPROM RS JA1 E_LCD OSC1 OSC2 SCLNLC SDA SDATD MOSI , ICP_Clock ICP_CLK MC_GND Oscillator STPM01_CON ICP_CLK ICCSEL RESET MC_+5.0V 5.0V LED MC_+5.0V E_LCD XRESET ICCCLK SYN STPM01_CON SCS SCL GND SYN SCS ICCDATA , to the STPM01. 1. Cut the tracks on the control board (at points A and B, see Figure 3) to


Original
PDF AN2179 STPM01) AN2179 lcd power board schematic STPM01 1N4148 ST72324 ST72F324
2012 - ALTAIR05T-800

Abstract: Altair 4.7uF 400V RTD14-SPDT ST7540 ALTAIR05T-8
Text: 36 35 34 33 32 31 30 29 28 27 26 25 OPT_CMD STPM01_SYN USART_RX USART_TX MCO STPM01_MOSI STPM01_MISO STPM01_SCK STPM01_SCS C6 22pF +3. 3V C100 100nF PA1 PA2 PA3 C7 470nF I2C2_SDA I2C2_SCL , and STPM01 Data brief Features Energy measurement by the STPM01 Power line communication , . The board is based on the STM32F103CB microcontroller, the ST7540 PLM module and the STPM01 mono-phase , STEVAL-IHP002V2 Figure 6. VCC_3V3 VCC_3V3 R 85 2.4k 2.4k 2.4k R 86 R 87 R88 4K7 STPM01


Original
PDF STEVAL-IHP002V2 STM32, ST7540 STPM01 STPM01 STEVAL-IHP002V2 STM32F103CB ALTAIR05T-800 Altair 4.7uF 400V RTD14-SPDT ALTAIR05T-8