The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
INA207AIPW Texas Instruments 80V, Low-/High-side, High-Speed, Voltage Output CSA with Window Comparator 14-TSSOP -40 to 125
INA207AIPWG4 Texas Instruments DUAL COMPARATOR, 2500uV OFFSET-MAX, 1300ns RESPONSE TIME, PDSO14, GREEN, PLASTIC, TSSOP-14
INA207AID Texas Instruments 80V, Low-/High-side, High-Speed, Voltage Output CSA with Window Comparator 14-SOIC -40 to 125
INA207AIPWR Texas Instruments 80V, Low-/High-side, High-Speed, Voltage Output CSA with Window Comparator 14-TSSOP -40 to 125
INA207AIDG4 Texas Instruments 80V, Low- or High-side, High-Speed, Voltage Out Current Shunt Monitor with Window Comparator & Ref 14-SOIC -40 to 125
INA207AIPWRG4 Texas Instruments Unidirectional Measurement Current-Shunt Monitor with Dual Comparators 14-TSSOP -40 to 125

SCR 207A Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2005 - TLP250 MOSFET DRIVER application note

Abstract: TLP250 MOSFET DRIVER calculation of IGBT snubber 74hc06 tlp250 equivalent TLP250 igbt driver applications TLP250 application note difference between IGBT and MOSFET IN inverter SCR 207A scr driver ic for rectifier 3 phase
Text: ( SCR ) Anode i i E v Gate Cathode E vT iG Thyristor can be switched on by DC or , of diode, onstate voltage of SCR , or on-resistance of MOSFET. 100A 15V E C G 100mA 5V , (103.5A) 50A (51.0A) 15kW 200A ( 207A ) 100A (103.5A) 30kW 400A (414A) 200A ( 207A


Original
PDF 00A/600V 00A/1200V TLP250 MOSFET DRIVER application note TLP250 MOSFET DRIVER calculation of IGBT snubber 74hc06 tlp250 equivalent TLP250 igbt driver applications TLP250 application note difference between IGBT and MOSFET IN inverter SCR 207A scr driver ic for rectifier 3 phase
Not Available

Abstract: No abstract text available
Text: RANGE ACCURACY -160 to 654°C -108 to 207 °C -5 to 414°C 194 to 608°C -157 to 640°C -106 to , conduit or raceway with AC power lines, conductors feeding motors, solenoids, SCR controls, and heaters


Original
PDF LP0393 Ahmedabad-382480
Not Available

Abstract: No abstract text available
Text: to 654°C -108 to 207 °C -5 to 414°C 194 to 608°C -157 to 640°C -106 to 203°C -5 to 406 , , SCR controls, and heaters, etc. The cables should be run in metal conduit that is properly grounded


Original
PDF LP0437 Ahmedabad-382480
2001 - specifications of scr

Abstract: SCR GATE DRIVER scr specifications DATA SHEET SCR TRANSISTOR SCR TRIGGER circuit SCR RECTIFIER scr latching specifications of scr rating DATASHEET SCR SCR gate driver circuit
Text: SCR Latch-Up Model - Preventing Latch-Up in Intel® Transceivers Application Note January 2001 , incompatibilities arising from future changes to them. The SCR Latch-Up Model may contain design defects or errors , Note SCR Latch-Up Model - Preventing Latch-Up in Intel® Transceivers Contents 1.0 , . 5 1.1 1.2 SCR Latch-Up Description , .6 1 2 SCR Latch-Up Model


Original
PDF AN048. LXT305A) specifications of scr SCR GATE DRIVER scr specifications DATA SHEET SCR TRANSISTOR SCR TRIGGER circuit SCR RECTIFIER scr latching specifications of scr rating DATASHEET SCR SCR gate driver circuit
2014 - Not Available

Abstract: No abstract text available
Text: ( SCR ) Automatic EOL Reset Capability Easily Added to Existing GFCI Applications Built-in 5 V Shunt , periodically tests for the functional operation of the GFCI controller, solenoid, sense transformer, SCR , and , RIN RTEST2 D6 Q1 R1 VS AmpOut SCR Test VFB GND C5 VREF R2 Figure 1 , SCR C1 R4 RSET R3: 1 M R4: 909 k RIN: 470  RTest1: 15 k RTest2: 10 , www.fairchildsemi.com 2 6 Fault Test 2 5 EOL Alarm 3 4 Phase SCR Test 1 GND VDD


Original
PDF FAN41501 UL943 90-Minute com/dwg/MA/MA06A dwg/PKG-MA06A
list of scr

Abstract: ami 9071 SCR-1912 SCR104 SCR1924 SCR-233 SCR-1782 bbu installation scr1479 9650SE
Text: certain SAS drives ( SCR -1767) Corrected a rare data integrity issue affecting 9690SA controllers from , with RAID-5 arrays ( SCR -1912) Eliminated a rare chance of a data integrity issue from occurring if a , changes ( SCR -1675) The background task rate settings for rebuild/migrate and verify have been corrected , error handling ( SCR -1971) The FreeBSD driver has been fixed so that if a controller error is , after initialization ( SCR -1924) A false verification failure no longer occurs after initializing a RAID


Original
PDF 9690SA 9650SE 64-bit SCR-1161) SCR-1219) SCR-2018) list of scr ami 9071 SCR-1912 SCR104 SCR1924 SCR-233 SCR-1782 bbu installation scr1479
1997 - SCR WITH I-V CHARACTERISTICS

Abstract: SCR TRIGGER PULSE circuit how to test scr HP54540A dual zener diode 3B 10kv scr SP721 digital triggering scr scr 6A SP720
Text: discharge. The SCR cell structures of this family were first introduced for ESD protection of sensitive ICs , primary ESD protection requirement of the SCR structure is to absorb and divert energy away from the , SCR PROTECTION CELL (ON) IN REVERSE SCR PROTECTION CELL (OFF) TO PROTECTED IC INPUT Turn-On Time of the SP721AP Figure 1 shows the paired SCR cell configuration of the SP721 with an illustration of how it responds to a positive ESD pulse applied to the input. The top or forward SCR cell


Original
PDF SP720, SP721 SP723 AN9708 SP720 SP721 SP723 SCR WITH I-V CHARACTERISTICS SCR TRIGGER PULSE circuit how to test scr HP54540A dual zener diode 3B 10kv scr digital triggering scr scr 6A SP720
1998 - ic mm74hc

Abstract: triggering scr with microprocessor AN-339 national cmos scr WHAT IS THE CONNECTION SCR 74HC MM74C CD4000 AN-339 SCR TRIGGER PULSE circuit
Text: Fairchild Semiconductor Application Note 339 November 1987 INTRODUCTION SCR latch-up is a , latch-up mechanism, once triggered, turns on a parasitic SCR internal to CMOS circuits which essentially , . It is primarily several proprietary innovations in CMOS processing that eliminates the SCR . First, what is " SCR latch-up?" It is a phenomena common to most monolithic CMOS processes, which involves , similar structure. These diodes can act as the gate to the parasitic SCR , and if enough current flows the


Original
PDF MM54HC/MM74HC ic mm74hc triggering scr with microprocessor AN-339 national cmos scr WHAT IS THE CONNECTION SCR 74HC MM74C CD4000 AN-339 SCR TRIGGER PULSE circuit
1995 - triggering scr with microprocessor

Abstract: cmos function generator using cd4049 ic mm74hc scr Power Supply Schematic Diagram national semiconductor CD4000 cmos scr MM74HC AN-339 national CD4049 Application CD4000
Text: INTRODUCTION SCR latch-up is a parasitic phenomena that has existed in circuits fabricated using bulk silicon CMOS technologies The latch-up mechanism once triggered turns on a parasitic SCR internal , processing that eliminates the SCR First what is `` SCR latch-up '' It is a phenomena common to most , SCR and if enough current flows the SCR will trigger A second method of turning on the SCR is to , method is more uncommon In either case once the SCR is turned on a large current will flow from VCC to


Original
PDF MM54HC MM74HC triggering scr with microprocessor cmos function generator using cd4049 ic mm74hc scr Power Supply Schematic Diagram national semiconductor CD4000 cmos scr AN-339 national CD4049 Application CD4000
2000 - TRIAC RCA

Abstract: triac specifications Gate turn off triac SCR TRIGGER PULSE circuit RCA THYRISTOR scr rca specifications of scr thyristor driving circuit SCR Gate Drive turn off thyristor rca
Text: symbols for Thyristors: Name of Device Silicon Controlled Rectifier ( SCR ) Symbol G A K Triac , SCR and TRIAC specifications.) Symbol di/dt Terminology CRITICAL RATE OF RISE OF ON­STATE , the rate of rise of on­state current which a Triac or SCR can withstand without damage. Is the ability , when the SCR or Triac is in the off­state. Frequently referred to as leakage current in the forward , cathode and anode of an SCR ) in order to turn from the off­state to the on­state while its IGT is being


Original
PDF
DIODE ED 34

Abstract: 12v DC motor speed control using scr SCR 2000 A SCR 100A SCR 100A 100V diode ED 21 DIODE ED 16 scr 6 Ampere SCR gate Control IC SCR Phase Control IC
Text: ., 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 72.75.15 Dual SCR , SCR /Diode isolated Modules 210-250-260 Amperes 100-2000 Volts Dual SCR , SCR /Diode Isolated Modules Outline Drawing Dimension Inches , 2.09 53.1 U .110 X .032 2.8 X 0.8 V .52 13 Dual SCR , SCR /Diode Isolated Modues 210-250-260 Amperes , you desire from the table — i.e. ED430825 is an 800 Volt, 250 Ampere Dual SCR Phase Control Module , Volt, 250 Ampere dual SCR module). Diode voltage is same as SCR except for ED72, ED77, where suffix OY


OCR Scan
PDF 72TMbai BP107, Amperes/100-2000 ED42/ED47 DIODE ED 34 12v DC motor speed control using scr SCR 2000 A SCR 100A SCR 100A 100V diode ED 21 DIODE ED 16 scr 6 Ampere SCR gate Control IC SCR Phase Control IC
2014 - Not Available

Abstract: No abstract text available
Text: ( SCR ) Automatic EOL Reset Capability Easily Added to Existing GFCI Applications Built-in 5 V Shunt , periodically tests for the functional operation of the GFCI controller, solenoid, sense transformer, SCR , and , RIN RTEST2 D6 Q1 R1 VS AmpOut SCR Test VFB GND C5 VREF R2 VDD FAN41501 GND C4 FAN4149 SCR C1 R4 RSET Fault Test Q2 EOL Alarm Phase Figure 1 , www.fairchildsemi.com 2 6 Fault Test 2 5 EOL Alarm 3 4 Phase SCR Test 1 GND VDD


Original
PDF FAN41501 UL943 90-Minute com/dwg/MA/MA06A dwg/PKG-MA06A
1997 - SCR WITH I-V CHARACTERISTICS

Abstract: SCR PIN CONFIGURATION SCR TRIGGER PULSE circuit how to test scr SCR FAST SWITCHING AN9708 SP721 scr 6A ESD AND diode AND SCR SCR TRIGGER circuit
Text: peak current. Positive and negative SCR cells are paired to work as active switches. The energy of an ESD discharge is both absorbed and shunted by the SCR to the supply line (positive pulse) or ground (negative pulse). When the energy is dissipated, the SCR quickly returns to its off state because there is no current to sustain the latched holding condition of the SCR . The purpose of this Application , , SP721 and SP723 family of protection ICs during an ESD discharge. The SCR cell structures of this


Original
PDF AN9708 SP720, SP721 SP723 1-800-4-HARRIS SCR WITH I-V CHARACTERISTICS SCR PIN CONFIGURATION SCR TRIGGER PULSE circuit how to test scr SCR FAST SWITCHING AN9708 scr 6A ESD AND diode AND SCR SCR TRIGGER circuit
2000 - SCR 2000

Abstract: SCR TRANSISTOR
Text: TISP8200M, BUFFERED P-GATE SCR DUAL TISP8201M, BUFFERED N-GATE SCR DUAL COMPLEMENTARY BUFFERED-GATE , Pgate SCRs with a common anode connection. Each SCR cathode and gate has a separate terminal connection , ADVANCE INFORMATION TISP8200M, BUFFERED P-GATE SCR DUAL TISP8201M, BUFFERED N-GATE SCR DUAL , transistor. If sufficient clipping current flows the SCR will regenerate and switch into a low voltage on-state condition. As the overvoltage subsides the high holding current of the SCR prevents d.c. latchup


Original
PDF TISP8200M, TISP8201M, TISP8200M 10/1000rmed, SCR 2000 SCR TRANSISTOR
2002 - phase angle controller

Abstract: General electric SCR manual
Text: PK501-1 SCR Power Theory Training Manual CHROMALOX TRAINING www.chromalox.com , (615) 793-3900 www.mychromalox.com 800 443-2640 Revised 1/2002 CHROMALOX® SCR POWER THEORY - TRAINING MANUAL TABLE OF CONTENTS INTRODUCTION TO SCR POWER THEORY , . 7 SCR CONTROL FIRING . 9 , /Zero Fire Combination Control . 16 SCR APPLICATIONS


Original
PDF PK501-1 phase angle controller General electric SCR manual
SCR 100A

Abstract: 4 pin SCR gate drive circuit scr 20a SCR gate protection circuit SCR Gate Drive low voltage scr UC2908 pin diagram of SCR UC1908 UC3908
Text: Activated • Gate Drive to External SCR Provided if Fault Persists • Overvoltage Flag Available for , maximum value. It also provides a gate signal to an external SCR which crowbars the output if the shunted , 165°C, or if the shunt transistor is saturated, a gate drive signal is sent to an external SCR to , -3 — 1.19V ADJ Ì GND 1-2 o S Q R SCR SATURATION THERMAL PWR DETECTOR SHUTDOWN UP , , Ivc .20A Input Voltage Range .-0.3V to 9V SCR


OCR Scan
PDF UC1908 UC2908 UC3908 UC3908 uc1908 001b205 SCR 100A 4 pin SCR gate drive circuit scr 20a SCR gate protection circuit SCR Gate Drive low voltage scr UC2908 pin diagram of SCR
mosfet triggering circuit for inverter

Abstract: digital triggering scr P-Channel Depletion Mosfets SCR TRANSISTOR scr triggering SCR RECTIFIER AN-109 1N914 Mark Alexander SCR Inverter
Text: to as an SCR (Silicon Controlled Rectifier). This parasitic SCR is inherent in all CMOS input and , examines the mechanisms that cause SCR action in CMOS integrated circuits, discusses the pitfalls that are , Identifying the Causes of Latch-up, and Latch-up Prevention Techniques. SCR OPERATION Prior to discussing latch-up in CMOS ICs, it is useful to review the basic theory of SCR operation to gain an understanding of the underlying mechanisms that cause latch-up. An SCR has the PNPN structure and characteristics shown


OCR Scan
PDF AN-109 mosfet triggering circuit for inverter digital triggering scr P-Channel Depletion Mosfets SCR TRANSISTOR scr triggering SCR RECTIFIER AN-109 1N914 Mark Alexander SCR Inverter
transistor c3423 Y

Abstract: MCR81-5 scr 2n6508 3 pin SCR PIN CONFIGURATION
Text: regulator failures when used in conjunction with an external "crowbar" SCR . The device senses the , threshold or trip voltage at which the MC3423 will trigger and supply gate drive to the crowbar SCR , 0 1 , limiting resistor, R g , is given in Figure 9. Using this value of R g , the SCR , Q1, will receive the , , the power supply, across which the SCR is connected, must be shut down to reset the crowbar. If a non current-lim ited supply is used, a fuse or circuit breaker, F1, should be used to protect the SCR and/or the


OCR Scan
PDF MC3423 2N6400 2N6504 2N1842 2N2573 2N681 MCR3935-1 MCR81-5 T0-220 transistor c3423 Y scr 2n6508 3 pin SCR PIN CONFIGURATION
digital triggering scr

Abstract: mosfet triggering circuit for inverter modern transistor substitute 1n014 12 VOLTS INVERTER CIRCUIT USING MOSFET SCR Gate Drive SCR IC CHIP scr triggering HP5082-2835 two transistor forward
Text: to as an SCR (Silicon Controlled Rectifier). This parasitic SCR is inherent in all CMOS input and , examines the mechanisms that cause SCR action in CMOS integrated circuits, discusses the pitfalls that are , Identifying the Causes of Latch-up, and Latch-up Prevention Techniques. SCR OPERATION Prior to discussing latch-up in CMOS ICs, it is useful to review the basic theory of SCR operation to gain an understanding of the underlying mechanisms that cause latch-up. An SCR has the PNPN structure and characteristics shown


OCR Scan
PDF AN-109 digital triggering scr mosfet triggering circuit for inverter modern transistor substitute 1n014 12 VOLTS INVERTER CIRCUIT USING MOSFET SCR Gate Drive SCR IC CHIP scr triggering HP5082-2835 two transistor forward
SCR-945

Abstract: SCR-521 SCR-997 SCR-705 SCR102 scr 1030 how to check scr SCR-754 scr101 3DM2
Text: disabled ( SCR -819) Updated 3BM to support up to 3 boards per BIOS session ( SCR -1017). Additional 9750 , a drive data cable rapid disconnect and reconnect under heavy I/O ( SCR -800) Fix to keep a degraded RAID 5 unit online if one of the remaining drives has a recoverable link problem ( SCR -771) 3DM2 now , have been changed ( SCR -698) 3BM (BIOS) now shows the correct initialization percentage completed for newly created redundant units ( SCR -836) Direct attached backplanes will now illuminate the applicable


Original
PDF 9750-8i" com/KnowledgebaseArticle15595 com/KnowledgebaseArticle15693 826TQ SCR-978) p/n-45749-01 SCR-945 SCR-521 SCR-997 SCR-705 SCR102 scr 1030 how to check scr SCR-754 scr101 3DM2
2000 - SCR GTO

Abstract: RC firing circuit FOR SCR SCR Gate Drive scr RC snubber design dc circuit breaker using SCR gto firing circuit powerex diode module lead finish powerex cd scr latching selen
Text: POW-R-BLOKTM Module Mounting Figure 2.1 SCR /GTO/Diode POW-R-BLOKTM Modules Application Information , example, a 90 Ampere, 1000 Volt SCR is guaranteed to turn on if a 100 mA, 3 Volt gate drive is applied , signal is a pulse only a few microseconds wide. To achieve reliable performance of the SCR , a gate , diverse range of SCR applications, a DC gate test condition with a resistive load was established for , Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex Semiconductor Data Book SCR


Original
PDF
16 amp SCR application

Abstract: SCR 214 s635 S525 scr 6 Ampere scr bt series 200 A SCR 75 Volts 10 amp thyristor BT 200 thyristor BT heat sink of scr
Text: PRESS FIT SERIES! SCR 's 8 AMPERE CENTER GATE 10 AMPERE CENTER GATE 20 AMPERE CENTER GATE 25 AMPERE CENTER GATE 35 AMPERE CENTER GATE j MÉ Hutson's SCR 's feature proprietary, void-free glass , associated with organic passivation materials. SCR 's are available in current ratings to 40 amperes and voltage (VDRM) ratings to 800 volts. These economical and highly reliable SCR 's are the result of Hutson , .) 3.0 (Typ.) 3.2 (Typ.) INSTALLATION INSTRUCTIONS Yz" PRESS FIT SCR 's 1. Recommended Heat Sink


OCR Scan
PDF
1996 - SCR Gate Drive

Abstract: scr drive circuit diagram SCR gate drive circuit SCR 100A 100A SCR CONNECTION asymmetrical SCR 4 pin SCR gate drive circuit scr circuit diagram SCR TRIGGER PULSE circuit SCR gate Control IC
Text: , regulates the output voltage to programmed maximum value. It also provides a gate signal to an external SCR , Drive to External SCR Provided if Fault Persists · Overvoltage Flag Available for Duration of , signal is sent to an external SCR to short circuit the output to ground. An internal latch is also , 9V SCR /Latch Trip Current . . . . . . . . . . . . . . . . . . . . . . . . . . . .20A Storage , with 10µF to GND, RSCR = 10k from SCR to GND, TA=TJ. PARAMETER VC Standby/Active IVC(Standby) IADJ


Original
PDF UC1908 UC2908 UC3908 UC3908 O-220 Figure10. SCR Gate Drive scr drive circuit diagram SCR gate drive circuit SCR 100A 100A SCR CONNECTION asymmetrical SCR 4 pin SCR gate drive circuit scr circuit diagram SCR TRIGGER PULSE circuit SCR gate Control IC
list of scr

Abstract: 9690SA SCR104 ami 9071 9650SE MBA3300RC SCR-1782 MBA3147RC
Text: integrity issue with certain SAS drives ( SCR -1767) Corrected a rare data integrity issue affecting 9690SA , integrity issue with RAID-5 arrays ( SCR -1912) Eliminated a rare chance of a data integrity issue from , setting changes ( SCR -1675) The background task rate settings for rebuild/migrate and verify have been , error handling ( SCR -1971) The FreeBSD driver has been fixed so that if a controller error is , after initialization ( SCR -1924) A false verification failure no longer occurs after initializing a RAID


Original
PDF 9690SA 9650SE 64-bit SCR-1161) SCR-1219) SCR-2018) list of scr SCR104 ami 9071 MBA3300RC SCR-1782 MBA3147RC
2001 - SCR GATE DRIVER

Abstract: SCR Gate Drive SCR TRANSISTOR PEB4264 SCR gate drive circuit GR-1089-CORE TISP8200M TISP8200MDR TISP8201M TISP8201MDR
Text: TISP8200M, BUFFERED P-GATE SCR DUAL TISP8201M, BUFFERED N-GATE SCR DUAL COMPLEMENTARY , array of two buffered Pgate SCRs with a common anode connection. Each SCR cathode and gate has a , P-GATE SCR DUAL TISP8201M, BUFFERED N-GATE SCR DUAL COMPLEMENTARY BUFFERED-GATE SCRS FOR OVERVOLTAGE , SCR will regenerate and switch into a low voltage on-state condition. As the overvoltage subsides the high holding current of the SCR prevents d.c. latchup. The TISP8201M has an array of two buffered


Original
PDF TISP8200M, TISP8201M, TISP8200M SCR GATE DRIVER SCR Gate Drive SCR TRANSISTOR PEB4264 SCR gate drive circuit GR-1089-CORE TISP8200M TISP8200MDR TISP8201M TISP8201MDR
Supplyframe Tracking Pixel