The Datasheet Archive

Top Results (5)

Part Manufacturer Description Datasheet Download Buy Part
XTR103BU Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-SOIC
XTR103BU/1K Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-SOIC
XTR103AP Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-PDIP
XTR103AP2 Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-PDIP
XTR103BP1 Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-PDIP

RTD PT100 3wire Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1999 - Not Available

Abstract: No abstract text available
Text: Validation Key Increment Key Input Types and Ranges Type J J DIN K T E S R B N C RTD ( Pt100 , 3-wire ) MV* Range -200 to 1200°C -328 to 2192°F -200 to 1000°C -328 to 1832°F -200 , Section A ߜ User Selectable Inputs: Thermocouple, RTD , Current, Voltage ߜ User Selectable


Original
PDF DPS801 DPS800 PX302 KMTSS-125G-6 DPS801 RS-232
rtd pt100

Abstract: 7-segment 4 digit rtd pt100 3 wire
Text: Function/Range J Thermocouple K Thermocouple RTD , PT100 3-wire E Thermocouple T Thermocouple Selection , Excitation POWER REQUIREMENTS AC DC ACCURACY @ 25°C as % of rdg Sensor Type RTD Pt 100 J K E T ENVIRONMENTAL


Original
PDF RS485 4-20mA 111mA 353mA 200mV 10DCV 100DCV 300DCV rtd pt100 7-segment 4 digit rtd pt100 3 wire
1999 - Not Available

Abstract: No abstract text available
Text: , R, S, B; RTD Pt100 , 3-Wire alpha=0.00385; Process: 0 to 50 mV, 0 to 10 V, 4 to 20 mA, 0 to 20 mA , % of span error; RTD Pt100 , 50 Ω/lead: <0.5% of span error Environmental EMI Susceptibility , Warranty Program CN1166 Series 240 $ Basic Unit ߜ Universal Input: Thermocouple, RTD , : Adjustable ± input span P-38 RTD Sensor Current: 150 µA (approximately) Accuracy: ±0.25% of span  , ( PT100 ) User-selectable with Operating Conditions “bumpless” transfer into Ambient Temperature


Original
PDF CN1166 RS-485 RS-485 BD1600-R* BD1600-DC* BD1600-T* BD1600-F* BD1600-TPS* BD1600-C4
CTL-6-S

Abstract: Fuji Electric PXR4 Manual PXW4 PXZ4 TRANSFORMER CTL-6-S CTL-12-S36-8 dsp-104 ZZPPXR1-A230 Fuji Electric PXR4 humidity controller Manual TN512642-E
Text: signal> Thermocouple °C Thermocouple °F RTD Pt100 3-wire type °C RTD Pt100 3-wire type °F 1 to 5V DC , Screw-terminal type 5 Thermocouple °C Thermocouple °F Resistance bulb Pt100 3-wire type °C Resistance bulb Pt100 3-wire type °F 1 to 5V DC 4 to 20mA DC 6 Relay contact output , Thermocouple °F Resistance bulb Pt100 3-wire type °C Resistance bulb Pt100 3-wire type °F 1 to 5V DC 4 to , Specification 4 T R Thermocouple °F Resistance bulb Pt100 3-wire type I (°C) Note 5


Original
PDF 1125r 9696mm RS485 4896mm 7272mm 4848mm 2448mm 2010-9/15FOLS CTL-6-S Fuji Electric PXR4 Manual PXW4 PXZ4 TRANSFORMER CTL-6-S CTL-12-S36-8 dsp-104 ZZPPXR1-A230 Fuji Electric PXR4 humidity controller Manual TN512642-E
2007 - pt100 sensor interface WITH ADC

Abstract: rtd temperature instrumentation amplifier circuit pt100 temperature sensor schematic PT100 bridge adc pt100 schematic pt100 temperature wheatstone ISL6007 pt100 temperature sensor schematic channels rtd temperature instrumentation amplifier amplifier ir application circuit
Text: . 24 RTD Input with A/D Converter Output


Original
PDF AN1298 EL817x EL8170 pt100 sensor interface WITH ADC rtd temperature instrumentation amplifier circuit pt100 temperature sensor schematic PT100 bridge adc pt100 schematic pt100 temperature wheatstone ISL6007 pt100 temperature sensor schematic channels rtd temperature instrumentation amplifier amplifier ir application circuit
2007 - pt100 sensor interface WITH ADC

Abstract: rtd temperature instrumentation amplifier pt100 temperature sensor schematic design the instrumentation amplifier with bridge rtd temperature instrumentation amplifier circuit circuit diagram of instrumentation amplifier instrumentation amplifier PT100 bridge adc pt100 temperature sensor schematic channels PT100 Thermocouple Amplifier
Text: . 23 RTD Input with A/D Converter Output


Original
PDF AN1298 EL8170 pt100 sensor interface WITH ADC rtd temperature instrumentation amplifier pt100 temperature sensor schematic design the instrumentation amplifier with bridge rtd temperature instrumentation amplifier circuit circuit diagram of instrumentation amplifier instrumentation amplifier PT100 bridge adc pt100 temperature sensor schematic channels PT100 Thermocouple Amplifier
PXW4

Abstract: TRANSFORMER CTL-6-S Fuji Electric PXR4 Manual fuji pxz4 CTL-6-S Fuji Electric PXR4 humidity controller Manual PXZ4 CTL-6-S-H DSP31 fuji pxr
Text: > Thermocouple °C Thermocouple °F RTD Pt100 3-wire type °C RTD Pt100 3-wire type °F 1 to 5V DC 4 to 20mA DC , Screw-terminal type 5 Thermocouple °C Thermocouple °F Resistance bulb Pt100 3-wire type °C Resistance bulb Pt100 3-wire type °F 1 to 5V DC 4 to 20mA DC 6 Relay contact output , Resistance bulb Pt100 3-wire type °C Resistance bulb Pt100 3-wire type °F 1 to 5V DC 4 to 20mA DC 6 , self-tuning Heating and cooling (PID,fuzzy PID) Input signal Resistance bulb Pt100 Thermocouple Voltage


Original
PDF 1125j 9696mm 4896mm 4848mm 2448mm RS485 2003-6/30FIS PXW4 TRANSFORMER CTL-6-S Fuji Electric PXR4 Manual fuji pxz4 CTL-6-S Fuji Electric PXR4 humidity controller Manual PXZ4 CTL-6-S-H DSP31 fuji pxr
2012 - RTD PT100 3wire

Abstract: 4 wire rtd cable PT-100 RTD 3 wire RTD-3-F3105-36-T-1
Text: mm, thin film Pt100 RTD element, Class A accuracy with 4-wire fiberglass insulated cable 1 m (40 , Dia. x 25 long mm, Pt100 wire wound element, Class A accuracy with 3-wire fiberglass insulated cable , Response (63%) T Less Than 1 Second U  igh Accuracy Class A, Pt100 and H Pt1000 RTD Elements Standard , : RTD -3-F3105-36-T-1/3, 100 Ω, 2 x 2 mm, thin film Pt100 RTD element, 1⁄3 DIN accuracy with 4 , -2-1PT100KN2515-36-T-MTP, 100 Ω, 1.5 Dia. x 25 long mm, Pt100 wire wound element, Class A accuracy with 3-wire PFA insulated


Original
PDF RTD-2-1PT100KN2528-36-G com/rtd-2-f3105 RTD-2-F3105-36-G RTD-2-F3102-36-G RTD-2-1PT100KN25 RTD-3-F3105-36-B, Pt100 RTD-2-1PT100KN2515-36-B, FBGS-N-24 RTD PT100 3wire 4 wire rtd cable PT-100 RTD 3 wire RTD-3-F3105-36-T-1
2013 - Not Available

Abstract: No abstract text available
Text: ) Pt100 Standard IEC/DIN/EN 60 751-2 Long-term test IEC 770 6.3.2 RTD measuring current , reproduced in full. No cable compensation {3} RTD 3-wire cable compensation 3-wire compensation for transfer resistance {4} RTD 3-wire cable compensation Potentiometer Resistance , FlexTop 2202 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2-, 3- or 4 , Description FlexTop 2202 is a 4.20 mA loop-powered transmitter for Pt100 sensors. The Flex-Program has a


Original
PDF Pt100
Not Available

Abstract: No abstract text available
Text: resistance {4} 3-wire cable compensation RTD Potentiometer Resistance R R 4 , FlexTop 2202 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2-, 3- or 4 , transmitter for Pt100 sensors. The Flex-Program has a datalogging facility enabling the user to monitor , . Vibrations GL, test 2 (IEC 68-2-6) Pt100 Standard IEC/DIN/EN 60 751-2 Long-term test IEC 770 6.3.2 RTD measuring current 0.3 mA, continuously Sensor type 2-, 3- or 4-wires {1} Sensor


Original
PDF Pt100
2002 - RTD PT100 3wire

Abstract: MCR-SL-PT100-LP-I Pt100 3 wire pt100 temperature sensor circuit connection namur NE 43 pt100 4-20mA MCR-SL-PT100 rtd pt100 4-20ma connections pt100 temperature transducers Phoenix/pt100 4-20 ma
Text: 5 6 3-wire 4-wire TC 1 RTD 1 1 RTD 1 RTD 1 MCR-FL-.-LP , supplied with the following default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire , I 1 1 2 3 4 Compressor PT100 in 3-wire technology PHOENIX CONTACT page 6 of 6 , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4wire technology ­ Can be mounted on


Original
PDF PT100 MCR-SL-PT100-LP-I RTD PT100 3wire MCR-SL-PT100-LP-I Pt100 3 wire pt100 temperature sensor circuit connection namur NE 43 pt100 4-20mA MCR-SL-PT100 rtd pt100 4-20ma connections pt100 temperature transducers Phoenix/pt100 4-20 ma
TR800

Abstract: RTD PT100 3wire rtd pt100 4-20ma wiring diagram RTD PT-100 PT-100 RTD 3 wire rtd pt100 sensor 3 wire pt100 sensor wiring diagram PT-100 wiring diagram PT100 temperature sensor 0-400 PT-100 RTD 3 wire transmitter
Text: , K, and Pt-100 RTD Bottom View of Cover Fixed-Range Units Offered in Standard or Special , process signals, including J, K, and Pt100 inputs. Each transmitter offers 2 to 3-wire compensation and , SPAN RTD : 20°C (36°F) min, 500°C (900°F) max TC: 10mV min span * 0+50 INPUT RTD : Pt-100 , 2 , (for RTD ) Stability (For Both Zero & Span): Pt-100 (100°C span): 0.03% of span/°C, TC/mV (25mV input , terminal two. For Pt-100 RTD Inputs, connect the Pt-100 leads to input terminals 4, 5, and 6 according to


Original
PDF TR800 Pt-100 TR800 4-20mA) 4-20mA RTD PT100 3wire rtd pt100 4-20ma wiring diagram RTD PT-100 PT-100 RTD 3 wire rtd pt100 sensor 3 wire pt100 sensor wiring diagram PT-100 wiring diagram PT100 temperature sensor 0-400 PT-100 RTD 3 wire transmitter
2007 - Not Available

Abstract: No abstract text available
Text: FlexTemp 2311 Universal Transmitter 4.20 mA transmitter RTD , T/C, mV and R inputs Isolation voltage 2 kVac Configuration via FlexProgrammer Accuracy better than 0.1°C ( Pt100 ) Configurable , isolation between input and output. The input can be configured for RTD or T/C sensors, resistance , . The built-in temperature sensor or a remote Pt100 sensor can be used to compensate for "cold junction , CJC-compensation {1} Local < 0.7°C Storage temperature -55.90°C RTD measuring current 0.2 mA


Original
PDF Pt100) Pt100 UK/2007-06-01
2006 - PT-100 385 4wire

Abstract: PT-100 385 3wire RTD PT100 3wire rtd 1186
Text: seven RTD types, plus volts and ohms. The 724 even handles high-speed pulsed RTD circuits and provides , PT-100 (385) 0.33 °C PT-100 (393) 0.3 °C PT-100 (JIS) 0.3 °C PT-200 (385) 0.2 , -1000 (385) Resistance 0.0 Ω to 400.0 Ω 0.1 Ω (4-wire) 0.15 Ω (2- and 3-wire ) Resolution 0.1 °C J 0.7 °C 401 Ω to 1500 Ω 0.5 Ω (4-wire) 1 Ω (2- and 3-wire ) K 0.8 °C T 0.8 °C 1500 Ω to 3200 Ω 1 Ω (4-wire) 1.5 Ω (2- and 3-wire ) E 0.7 °C R


Original
PDF ITS-90 PTS-68 36-FLUKE PT-100 385 4wire PT-100 385 3wire RTD PT100 3wire rtd 1186
MCR-SL-PT100-LP-I

Abstract: PT100 application note RTD PT100 3wire PT100 SENSOR PT100 IEC 751 PT100 temperature transducer 3 wire pt100 thermometer pt100 sensors application note pt100 mcr pt100
Text: configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Headquar ters , MCR-SL-.-LP-. 5 RTD 1 3-wire 1 RTD 1 4-wire RTD 1 2 2 1 3 , default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. To , / 3 0 m A 1 P O W E R 1 2 3 4 15.05.05 TNR: 5107584-02 PT100 in 3-wire , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1


Original
PDF PT100 MCR-SL-PT100-LP-I MCR-SL-PT100-LP-I PT100 application note RTD PT100 3wire PT100 SENSOR PT100 IEC 751 PT100 temperature transducer 3 wire pt100 thermometer pt100 sensors application note pt100 mcr pt100
2010 - Not Available

Abstract: No abstract text available
Text: Resistance TC R R + RTD 3-wire cable compensation External CJC-compensation No , FlexTop 2221 Universal Transmitter 4.20 mA transmitter with HART® communication. RTD , T/C, mV , Accuracy < 0.1°C ( Pt100 ) Configurable linearisation, damping and status indication Current-trim and , configured for RTD or T/C sensors, resistance, current or voltage signals. Either 2-, 3- or 4-wire connection can be selected for the resistance input. The built-in temperature sensor or a remote Pt100


Original
PDF Pt100) UK/2010-03-03
Not Available

Abstract: No abstract text available
Text: Resistance TC R R + RTD 3-wire cable compensation External CJC-compensation No cable , FlexTop 2211 Universal Transmitter 4.20 mA transmitter RTD , T/C, mV and R inputs Isolation voltage 3.75 kVac Configuration via FlexProgrammer Accuracy better than 0.1°C ( Pt100 ) Configurable , output. The input can be configured for RTD or T/C sensors, resistance, current or voltage signals , sensor or a remote Pt100 sensor can be used to compensate for "cold junction" (CJC) if thermocouples are


Original
PDF Pt100) Pt100
2011 - Not Available

Abstract: No abstract text available
Text: R R + RTD 3-wire cable compensation External CJC-compensation No cable compensation {3} 3-wire compensation for transfer resistance {4} 3-wire cable compensation Pt xxx RTD , FlexTop 2211 Universal Transmitter 4.20 mA transmitter RTD , T/C, mV and R inputs Isolation voltage 3.75 kVac Configuration via FlexProgrammer Accuracy better than 0.1°C ( Pt100 ) Configurable , output. The input can be configured for RTD or T/C sensors, resistance, current or voltage signals


Original
PDF Pt100) Pt100
1997 - pt100/RTD PT100

Abstract: signal conditioning circuit for pt100 4-20 mA rtd temperature instrumentation amplifier circuit 13000 transistor TO-220 pt100 temperature sensor circuit diagram basic standard current source circuit diagram bridge transducer 4-20ma PT100 IEC 751 PT100 resistor RTD SENSING CIRCUIT 4-20mA
Text: : The measurement range is ­100°C to +200°C for a 3-wire Pt100 RTD connection. Determine the values for , ) TABLE I. RZ, RG, RLIN1, and RLIN2 Standard 1% Resistor Values for 3-Wire Pt100 RTD Connection with , standard 1% RG resistor values for a 3-wire Pt100 RTD connection with linearization. LINEARIZATION , the 1% resistor values for a 3-wire Pt100 RTD connection. If no linearity correction is desired, the , ) LOW UNADJUSTED ERROR TWO PRECISION CURRENT SOURCES: 800µA each LINEARIZATION 2- OR 3-WIRE RTD


Original
PDF XTR105 SBOS061B 4-20mA XTR105 4-20mA, Pt100 pt100/RTD PT100 signal conditioning circuit for pt100 4-20 mA rtd temperature instrumentation amplifier circuit 13000 transistor TO-220 pt100 temperature sensor circuit diagram basic standard current source circuit diagram bridge transducer 4-20ma PT100 IEC 751 PT100 resistor RTD SENSING CIRCUIT 4-20mA
2007 - Not Available

Abstract: No abstract text available
Text: FlexTemp 2321 Universal Transmitter 4.20 mA transmitter with HART® communication. RTD , T/C, mV , Accuracy < 0.1°C ( Pt100 ) Configurable linearisation, damping and status indication Current-trim and , and output. The input can be configured for RTD or T/C sensors, resistance, current or voltage , temperature sensor or a remote Pt100 sensor can be used to compensate for "cold junction" (CJC) if , ranges“ Protocol HCF standard, Rev.5 CJC-compensation Local < 0.7°C Features {1} RTD


Original
PDF Pt100) Pt100ation UK/2007-06-01
1997 - rtd pt100 4-20ma wiring diagram

Abstract: No abstract text available
Text: temperatures. TABLE I. RZ, RG, RLIN1, and RLIN2 Standard 1% Resistor Values for 3-Wire Pt100 RTD Connection , ) resistors should be used for RG. Table I provides standard 1% RG resistor values for a 3-wire Pt100 RTD , % resistor values for a 3-wire Pt100 RTD connection. If no linearity correction is desired, the VLIN pin , PRECISION CURRENT SOURCES: 800µA each LINEARIZATION 2- OR 3-WIRE RTD OPERATION LOW OFFSET DRIFT: 0.4µV/°C , the RTD , typically achieving a 40:1 improvement in linearity. An additional resistor is required for 3-wire


Original
PDF XTR105 SBOS061B 4-20mA 30nAPP 110dB DIP-14 SO-14 Pt100 XTR105 rtd pt100 4-20ma wiring diagram
1997 - pt100 on linearity

Abstract: rtd temperature instrumentation amplifier circuit
Text: temperatures. TABLE I. RZ, RG, RLIN1, and RLIN2 Standard 1% Resistor Values for 3-Wire Pt100 RTD Connection , ) resistors should be used for RG. Table I provides standard 1% RG resistor values for a 3-wire Pt100 RTD , % resistor values for a 3-wire Pt100 RTD connection. If no linearity correction is desired, the VLIN pin , PRECISION CURRENT SOURCES: 800µA each LINEARIZATION 2- OR 3-WIRE RTD OPERATION LOW OFFSET DRIFT: 0.4µV/°C , the RTD , typically achieving a 40:1 improvement in linearity. An additional resistor is required for 3-wire


Original
PDF XTR105 SBOS061B 4-20mA 30nAPP 110dB DIP-14 SO-14 Pt100 XTR105 pt100 on linearity rtd temperature instrumentation amplifier circuit
1997 - PT100RTD

Abstract: thermocouple sensor cu 3-wire connection PT100 bridge
Text: temperatures. TABLE I. RZ, RG, RLIN1, and RLIN2 Standard 1% Resistor Values for 3-Wire Pt100 RTD Connection , ) resistors should be used for RG. Table I provides standard 1% RG resistor values for a 3-wire Pt100 RTD , % resistor values for a 3-wire Pt100 RTD connection. If no linearity correction is desired, the VLIN pin , PRECISION CURRENT SOURCES: 800µA each LINEARIZATION 2- OR 3-WIRE RTD OPERATION LOW OFFSET DRIFT: 0.4µV/°C , the RTD , typically achieving a 40:1 improvement in linearity. An additional resistor is required for 3-wire


Original
PDF XTR105 SBOS061B 4-20mA 30nAPP 110dB DIP-14 SO-14 Pt100 XTR105 PT100RTD thermocouple sensor cu 3-wire connection PT100 bridge
ni500 DIN 43760

Abstract: PT500 IEC 751 Resistance characteristic Ni1000 Resistance characteristic Pt1000 W5Re-W26Re ni1000 DIN 43760 PT100 IEC 751 accuracy Ni100 sensor pt100 4-20 ma RTD PT1000 conversion
Text: Measuring Span Pt100 Pt500 Pt1000 according to IEC 751 Resistance thermometer ( RTD ) -200 to , thermometer ( RTD ): Td = ± (15 ppm/K · maximum measuring range + 50 ppm/K · set measuring range) · 3) · Pt100 , 3-wire 1 RTD 1 4-wire RTD 1 2 2 1 3 1 IN IN 2 4 4 2 , temperature range. The devices are supplied with the following default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Headquarters: © Phoenix Contact GmbH & Co. KG ·


Original
PDF
1997 - Pt100 Platinum Sensing Resistors

Abstract: pt100 amplifier circuit diagram thermocouple sensor cu 3-wire connection pt100 active bridge RTD PT100 3wire
Text: temperatures. TABLE I. RZ, RG, RLIN1, and RLIN2 Standard 1% Resistor Values for 3-Wire Pt100 RTD Connection , ) resistors should be used for RG. Table I provides standard 1% RG resistor values for a 3-wire Pt100 RTD , % resistor values for a 3-wire Pt100 RTD connection. If no linearity correction is desired, the VLIN pin , PRECISION CURRENT SOURCES: 800µA each LINEARIZATION 2- OR 3-WIRE RTD OPERATION LOW OFFSET DRIFT: 0.4µV/°C , the RTD , typically achieving a 40:1 improvement in linearity. An additional resistor is required for 3-wire


Original
PDF XTR105 SBOS061B 4-20mA 30nAPP 110dB DIP-14 SO-14 Pt100 XTR105 Pt100 Platinum Sensing Resistors pt100 amplifier circuit diagram thermocouple sensor cu 3-wire connection pt100 active bridge RTD PT100 3wire
Supplyframe Tracking Pixel