The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1124CS Linear Technology IC DUAL OP-AMP, 100 uV OFFSET-MAX, PDSO, Operational Amplifier
LT1126IJ8 Linear Technology IC DUAL OP-AMP, 100 uV OFFSET-MAX, CDIP8, HERMETIC SEALED, CERDIP-8, Operational Amplifier
LT1127IS Linear Technology IC QUAD OP-AMP, 100 uV OFFSET-MAX, PDSO, Operational Amplifier
LT1124CJ Linear Technology IC DUAL OP-AMP, 100 uV OFFSET-MAX, CDIP, 0.300 INCH, HERMETIC SEALED, CERDIP, Operational Amplifier
LTM2220IV-AA#PBF Linear Technology IC 1-CH 12-BIT PROPRIETARY METHOD ADC, PARALLEL ACCESS, PBCC100, 16 X 16 MM, MO-222, SIPLGA-100, Analog to Digital Converter
LT1124CN Linear Technology IC DUAL OP-AMP, 100 uV OFFSET-MAX, PDIP, 0.300 INCH, PLASTIC, DIP, Operational Amplifier

RTD PT-100 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
RTD PT-100

Abstract: PT-100 RTD Pt 100 RTD RTD pt 100 j-type thermocouple rtd high temperature pt-100 4-20mA thermocouple pt 100 PT 10 rtd 1200C
Text: extension cable. The 405000 is pre-configured to connect to a RTD Pt 100 for a temperature range of ­60 to , RTD Pt 100 RTD Pt 100 RTD Pt 100 RTD Pt 100 Input impedance Excitation current Circuit break protect Power supply Load capability Accuracy J or K thermocouple RTD Pt 100 Linearity Calibration , 405000 transmitter converts a J-type thermocouple, K-type thermocouple, or Pt 100 RTD signal into a , polarity protection · Rugged ABS casing J, K thermocouples, Pt 100 RTD Analog 4-20mA two-wire 32 to


Original
PDF 4-20mA 4-20mA 45VDC IP-42) RTD PT-100 PT-100 RTD Pt 100 RTD RTD pt 100 j-type thermocouple rtd high temperature pt-100 4-20mA thermocouple pt 100 PT 10 rtd 1200C
1998 - Not Available

Abstract: No abstract text available
Text: RTD Pt 100 ohm. Intrinsic error <0.2% of the measurement range for thermocouple inputs. Response , ) Input Types and Ranges Type J J DIN K T E R S B N C RTD Pt 100 MV N-40 Dimensions: 68 , Programmable Transmitter Multi-sensor Input Model TX500 486 $ ߜ User Selectable Inputs– Thermocouple, RTD , Current, Voltage ߜ Current and Voltage Output ߜ Input to Output , 3200°F -50 to 1760°C 212 to 3272°F 100 to 1800°C -328 to 2372°F -200 to 1300°C 32 to 4172Â


Original
PDF TX500 TX500 T500-DISPLAY
2002 - HH205A

Abstract: No abstract text available
Text: K K K,T,J,N, NonBuilt-in Dual K T/C K T/C E, R, S, N E, R, S, N Thermistor RTD Pt 100 RTD Pt 100 R,S contact thermistor multimeter DMM Pt100 RTD Infrared pyrometer 1 2 4 2 1 1 1/2/4 , °F Display 31⁄2 digits ߜ 200 Hrs. 9V 31⁄2 digits ߜ 100 Hrs 9V 3 digits 1999 counts ߜ 100 Hrs 9V 1999 counts 31⁄2 digits 31⁄2 digits 31⁄2 digits 31⁄2 digits 31⁄2 digits 31⁄2 digits 100 Hrs 9V >200 Hrs MN1604 100 Hrs MN1604 SMP


Original
PDF HHM29B-IR HHM31 HH508 HH509 RS-232 HH205A
2007 - PT-100 385 4wire

Abstract: RTD PT-100 ni 9219 RTD pt 100 PT-1000 RTD 3 wire RTD CIRCUITS analog instruments PT-100 385 3wire 72511 calibration certificate of k type thermocouple IEEE 1451.4 RTD
Text: 4-Wire and 3-Wire RTD , Pt 100 ±0.1, ±0.5 ±2400, ±6400 Quarter-Bridge, 350 ±0.1, ±0.5 , -Wire Resistance, 1 K ±15 ±30 4-Wire and 3-Wire RTD , Pt 1000 ±15 ±6 4-Wire and 3-Wire RTD , Pt 100 , , Pt 1000 7.6 1.7 1.1 0.4 4-Wire and 3-Wire RTD , Pt 100 10.8 1.9 1.9 0.9 , , 1.05 K Thermocouple ±125 mV ±125 mV 4-Wire and 3-Wire RTD Pt 1000, Pt 100 5.05 K, 505 , ±30, ± 100 4-Wire and 2-Wire2 Resistance, 10 K ±0.1, ±0.5 ±120, ±320 4-Wire and 2


Original
PDF 72252A-01 Mar07 PT-100 385 4wire RTD PT-100 ni 9219 RTD pt 100 PT-1000 RTD 3 wire RTD CIRCUITS analog instruments PT-100 385 3wire 72511 calibration certificate of k type thermocouple IEEE 1451.4 RTD
TR800

Abstract: RTD PT100 3wire rtd pt100 4-20ma wiring diagram RTD PT-100 PT-100 RTD 3 wire rtd pt100 sensor 3 wire pt100 sensor wiring diagram PT-100 wiring diagram PT100 temperature sensor 0-400 PT-100 RTD 3 wire transmitter
Text: SPAN RTD : 20°C (36°F) min, 500°C (900°F) max TC: 10mV min span * 0+50 INPUT RTD : Pt-100 , 2 , , K, and Pt- 100 RTD Bottom View of Cover Fixed-Range Units Offered in Standard or Special , (for RTD ) Stability (For Both Zero & Span): Pt- 100 ( 100 °C span): 0.03% of span/°C, TC/mV (25mV input , terminal two. For Pt- 100 RTD Inputs, connect the Pt- 100 leads to input terminals 4, 5, and 6 according to , linearization for Pt- 100 , and ice point reference compensation for thermocouples that are voltage linear. On


Original
PDF TR800 Pt-100 TR800 4-20mA) 4-20mA RTD PT100 3wire rtd pt100 4-20ma wiring diagram RTD PT-100 PT-100 RTD 3 wire rtd pt100 sensor 3 wire pt100 sensor wiring diagram PT-100 wiring diagram PT100 temperature sensor 0-400 PT-100 RTD 3 wire transmitter
1999 - Not Available

Abstract: No abstract text available
Text: Input: 3-wire RTD ( Pt 100 ), 0.00385 excitation, 2 mA lead wire (approx. 190 ft. of 20 gage Cu wire). , Thermocouples or RTD Input ߜ Easy to UseNo Programming Required The Model CN355 non-indicating and CN375 , digit ( RTD input) Resolution: 1°F or 1°C Output Type: SPDT latching mechanical relay, 240 Vac, 2.5 , screw terminal connections resistance, 100 Ω max; Upscale break protection standard Power , K K R R S RTD RTD Ordering Example: CN375-KF is an indicating high limit controller, type


Original
PDF CN355 CN375 CN375-KF P-138 CN350, CN360 CN370
Not Available

Abstract: No abstract text available
Text: , Thermistor, RTD 0 to 20 mA, 4 to 20 mA, 0 to 10 V  Thermistor Type and Temperature Ranges Thermistor 3K: 0 ~ 100° C Thermistor 10K: 0 ~ 100° C  RTD Type and Temperature Ranges Pt 100 RTD Pt - 100 ~ 100° C Pt 0 ~ 100° C Pt 0 ~ 200° C Pt 0 ~ 600° C IEC RTD 100 ohms (a = 0.00385) JIS RTD 100 ohms (a = 0.00392) Pt 1000 RTD Pt -40 ~ 160° C Analog Output  Channels  Output Type , - 100 ~ 400 °C E 0 ~ 1000 °C R 500 ~ 1750 °C S 500 ~ 1750 °C B 500 ~ 1800 °C Burn-out


Original
PDF ADAM-4019+ ADAM-4021 ADAM-4022T 16-bit /-10V, 100mV, /-500mV,
Cu50 RTD

Abstract: D977 transistor d722 RTD pt 100 RTD PT100 3wire RTD PT-100 D722 transistor nicr-ni temperature W5W26 Pt 100 RTD
Text: /beginning.end value of measuring range* 1) RTD Pt 100 Provide Range . . 1 . . . . 2) RTD Ni 100 Provide Range . . 2 . . . . 3) RTD Pt 100 .[] (see NOTE , or external. Three RTD types, Pt 100 , Cu50, and Ni 100 , can be interfaced in a two, three or four , , Isolated * External Input Range, RTD RTD Types: Pt 100 , Ni 100 OUTPUT RANGE 4 to 20mA, or , ). Type B: Pt30Rh-Pt6Rh Type E: NiCr-CuNi Measured Variables RTD : 2, 3, or 4-wire Pt 100


Original
PDF SCTP20 SCTP20 DSCX-887 DSCX-440 DSCX-895 RS-232C. 1500VRMS) SCTP20-01 SCTP20-02 Cu50 RTD D977 transistor d722 RTD pt 100 RTD PT100 3wire RTD PT-100 D722 transistor nicr-ni temperature W5W26 Pt 100 RTD
E5CS-Q1PX

Abstract: E5CS-Q1PX-F RTD PT-100 Omron E5CS-Q1KJX-F omron e5cs-x E5CS-R1KJX E5CS-Q1KJX-F ic pid control e5cs
Text: _ E5CS-Q1KJX-F E5CS-Q1PX-F S p e c ific a tio n s Part number E5CS-B1KJX E5CS- B1PX Platinum RTD ( Pt : 100 n , « tty p a Oatpat C M ltie t V Bitag« Thermocouple_ Platinum RTD (Pt: 10 0 fl , * Thermocouple Type J (IC) and Type K (CA) 100 to 240 VAC, 50/60 Hz; operates on 85 to 110% of rated voltage , output 100 ,000 operations minimum with contact output SPST-NO relay 1 A, 250 VAC (resistive load) ±0.5 of


OCR Scan
PDF E68481 LR59623 E5CS-Q1PX E5CS-Q1PX-F RTD PT-100 Omron E5CS-Q1KJX-F omron e5cs-x E5CS-R1KJX E5CS-Q1KJX-F ic pid control e5cs
2002 - PID controller

Abstract: No abstract text available
Text: Selection Guide i8DH i8 Description 1/8 DIN Single Display Monitor/ Controller Input Process and Temperature (model “i”) T/C: (J, K, T, E, R, S, B, N, C, J DIN) RTD : Pt 100 ,500,1000 Ohms (385,392) 4-20mA, 0-100mV, 0-1V, 0-10V Strain and Process (model “iS”) 4 to 20 mA, 0 to 100 mVdc, - 100 mVdc to 1 Vdc,0 to 10 Vdc Ratiometric/Non-Ratiometric 10 pt linearization Display Nine Segment LED Digits Color Programmable:Red, Amber, Green Height of Digits 1/8 DIN Dual Display


Original
PDF 4-20mA, 0-100mV, i8DV43 i8DH33-C4EI i8DV33 i8C00 i1600 i16D33 i3200 i8C53 PID controller
RTD PT-100

Abstract: PT-100 RTD 3 wire TTY 20MA 232-C PT-100 RTD DIN RTD pt 100 DIN 40050 ohm PT-100 class B
Text: error: <0.1% Influence of ambient: < 0.01 %/K RTD ; ( Pt 100 ) Built-in protection against breaks and , . C, (PT 100 ) 32 to 999 deg. F 2 and 4 wire circuits 64: RTD -90 to +300 deg. C, (PT 100 ) - 99 . . . +572 deg. F 2 and 4 wire circuits 65: RTD -90 to +300 deg. C, (PT 100 ) -99 to +572 deg. F 3 , Standard: PID with optimizing (auto-tuning) P-, PD-, PI action possible. Feed back P (xp): 0 to 100 % D (Tv): 0 to 200 sec. I (in): 0 to 999 sec. Cycle time: 1 to 240 sec. Limits; output: 1 to 100 % Setpoint


OCR Scan
PDF 232-C RTD PT-100 PT-100 RTD 3 wire TTY 20MA PT-100 RTD DIN RTD pt 100 DIN 40050 ohm PT-100 class B
1998 - RTD PT-100

Abstract: IEC1010 fp-rtd-122
Text: per channel) Range RTD , Pt 100 -200° to 800° C RTD , Pt 1000 -200° to 800° C Resistance , 8-Channel RTD Input Module FP-RTD-122 8 RTD or resistance inputs 100 and 1000 Pt RTDs , module for accurate measurement of RTD sensors. You can use the FP-RTD-122 to measure 100 and 1000 , , scaled RTD measurements. In addition, HotPnP plug and play operation and onboard diagnostics ensure that , . The RTD signal is filtered to remove 50 or 60 Hz noise, and digitized using a high-accuracy, 16


Original
PDF FP-RTD-122 16-bit FP-RTD-122 EN61010 RTD PT-100 IEC1010
TEMPERATURE CONTROLLER with pid

Abstract: E5CS-R1KJX-F PT-100 RTD 3 wire sensor rosemount temperature controller circuit diagram with relay temperature control using pid controller E5CS-R1KJX Thermocouple Type K RTD PT-100 E5CS-Q1KJX-F PID controller
Text: ) Platinum RTD ( Pt : 100 , DIN and JIS standards) Interchangeable thermistor (THE types) Contact , Thermocouple (Types J and K) Platinum RTD ( Pt : 100 , DIN and JIS standards) Interchangeable thermistor , ) Platinum RTD ( Pt : 100 ) DIN or JIS standard Thermistor (interchangeable type) Supply voltage 100 , Contact output type Thermocouple input type 100 to 240 VAC, 50/60 Hz Alarm output Platinum RTD , Thermistor sensor Note: The resistance of the platinum RTD is 100 at 0°C and increases to 140 at 100


Original
PDF H301-E3-1 TEMPERATURE CONTROLLER with pid E5CS-R1KJX-F PT-100 RTD 3 wire sensor rosemount temperature controller circuit diagram with relay temperature control using pid controller E5CS-R1KJX Thermocouple Type K RTD PT-100 E5CS-Q1KJX-F PID controller
rtd pt100

Abstract: 7-segment 4 digit rtd pt100 3 wire
Text: Excitation POWER REQUIREMENTS AC DC ACCURACY @ 25°C as % of rdg Sensor Type RTD Pt 100 J K E T ENVIRONMENTAL , to +200°C - 100 °C to +760°C -200°C to +1250°C - 100 °C to +800°C -200°C to +400°C 0 to 50°C -10 to +60°C <80% 25°C 100 ppm/°C ± 0.05 dgt/°C 10 minutes 60 dB @ 50-60 Hz 100 dB @ 50-60 Hz Successive , Function/Range J Thermocouple K Thermocouple RTD , PT100 3-wire E Thermocouple T Thermocouple Selection , Resolution Input 4.5 3.5 Impedance 200µA 10 nA .1 mA 1K 2 mA .1µA 1 mA 100 20 mA 1µA 10 mA 10 200 mA 10 µV .1


Original
PDF RS485 4-20mA 111mA 353mA 200mV 10DCV 100DCV 300DCV rtd pt100 7-segment 4 digit rtd pt100 3 wire
2002 - MUX C-Band

Abstract: RTD pt 100 RTD PT-100 GR-1209 RTD CIRCUITS
Text: RTD PT 100 Heater Power Weight 60 Optical interface g connectors upon request , DEMUX MUX C-Band L-Band 8 16 24 32 40 > 40 on request 200 100 50 on request 1 Low Loss 2 , open 3 Variable resistor 4 RTD H2 5 RTD H1 6 RTD L1 7 RTD L2 8 To , channel spacing of 100 GHz. The component is realized by a 40-Channel-Arrayed-Waveguide Grating (AWG). , 40 Channel spacing Df 100 Nominal center wavelength lc ITU-T grid Accuracy of


Original
PDF V23845-A/Bwxyz UL-94 GR-1209, GR-1221 V23845- MUX C-Band RTD pt 100 RTD PT-100 GR-1209 RTD CIRCUITS
1999 - Not Available

Abstract: No abstract text available
Text: „2, X5⁄2, T/C types: B, E, J, K, R, S, T, L, N or RTD Pt 100 P-99 Broken Sensor Protection , below 400°C (752°F) for types B, R and S thermocouples. RTD , 3-wire platinum, 100 ohm, with range of , ): Thermocouple (T/C), RTD , Millivolt, Current, dc Voltage, and Resistance Channel 3 (Actuator Position , ") Weight: 1.59 kg (3.5 lb) Universal Process Input • Thermocouple • RTD • 4-20 mA Volts , Inputs and Ranges Temperature Input Type B E J K L ( J DIN ) N R S T RTD (Pt 385) Range


Original
PDF CN3430 NEMA-4X/IP66 RS-485/MODBUS CN3430-12VDC, -12VDC -24VDC -24VAC CN3440 CN34-SW
2014 - PT-1000 sensor chart table

Abstract: No abstract text available
Text: resistance (0.10 V / 30 V) 0.10 V 0.5 mV ± 2 mV ± 0.05 % RTD Pt 100 Measuring range Resolution Accurancy RTD Pt 1000 Measuring range Resolution Accuracy Pulse Measuring range , operation, 4 h charging time Options Data logger: 100 million measuring values start/stop time , 4.20 mA 0.20 mA 0.10 V Pulse Pt 100 Pt 1000 20 www.cs-instruments.com Pressure , ressure by quick coupling Pt100 (2-wire or 3-wire) Pressure sensors 0-10/16/40/ 100 /250/400/600


Original
PDF
thermocouple temperature sensor

Abstract: RTD PT-100 TRMS RTD pt 100 0.56 4 digits 7-segment led display
Text: of rdg ± 1°C ±0.1% of rdg ± 1.8°F -328 to 752°F -200 to 850°C RTD Pt 100 -328 to 1562 , to 55°C -10 to 60°C 0 to 85% non-condensing Less than 20 minutes INPUTS Thermocouple RTD , 100 (.00385 alpha), 2, 3 or 4 wire ±84mV reading of uncompensated mV 7M (typical) 2-1/2 times per , T/C R T/C DCmV RTD Pt100 Ohm 41 42 43 44 45 46 200 AC A 2 ACmA 20 ACmA 200 AC mA 2


Original
PDF 220VAC, 50/60Hz 9-32DCV, Pt100 thermocouple temperature sensor RTD PT-100 TRMS RTD pt 100 0.56 4 digits 7-segment led display
2000 - OMRON CPM2A

Abstract: OMRON cpm2a manual plc omron CPM2A OMRON plc programming console manual cpm1a cable CPM1A-CIF01 special relay in omron plc program CPM1A-MAD01 manual CPM1A-20EDR CPM2A-30CDR-D
Text: Description Analog I/O 2 # Of I/O 1 Input Type 0 to 10V 1 to 5V 4 to 20mA RTD Pt 100 -40 to 250C Power Supply , module RTD and thermocouple temperature sensor modules Compobus adapter allows connection to a Compobus/S , -20 CPM2A-30 18 12 CPM2A-40 24 16 CPM2A-60 36 24 12 8 100 to 240 VAC 50/60 Hz 24 VDC 85 to 264


Original
PDF RS-232C CQM-CIF02 CPM1-CIF01 NT-AL001 3G2A9-AL004-E CPM1-CIF11 C200H-CN320-EU C200HS-CN220-EU CQM1-PRO01-E C200H-PRO27-E OMRON CPM2A OMRON cpm2a manual plc omron CPM2A OMRON plc programming console manual cpm1a cable CPM1A-CIF01 special relay in omron plc program CPM1A-MAD01 manual CPM1A-20EDR CPM2A-30CDR-D
Cu50 RTD

Abstract: LEXAN 940 IEC 60 751 RTD PT-100 Cold Junction Compensation NICR-NI thermocouple W5W26 Ni100 sensor DSCX-887 cu50 datasheet
Text: B) TC Type B 2) RTD Ni 100 Specify: 1) RTD Pt 100 Specify Range: ° to (See , . Three RTD types, Pt 100 , Cu50*, and Ni 100 , can be interfaced in a two, three or four wire connection , Types: Pt 100 , Ni 100 RTD Excitation Current Input Resistance Lead Resistance Output Range CMV , Table 1 Measured Variables Limits RTD : 2, 3, or 4-wire Pt 100 , Standard IEC 60 751 Ni 100 , NOTE: Any value between 4 and <21.6mA *The short-circuit signal is only active for RTD measuring 100 at


Original
PDF SCTP20 SCTP20 DSCX-887 DSCX-440 DSCX-895 RS-232C. SCTP20-01 SCTP20-02 Cu50 RTD LEXAN 940 IEC 60 751 RTD PT-100 Cold Junction Compensation NICR-NI thermocouple W5W26 Ni100 sensor cu50 datasheet
2000 - E5CS-R1PX-F

Abstract: E5CS-R1PX E5CS-R1KJX-F data sheet omron E5CS-R1PX E5CS-Q1PX-F E5CS-Q1PX E5CS-Q1KJX-F temperature controller circuit diagram with relay 1px transistor DIP switch
Text: Item Part number Sensor input type Thermocouple (Types J and K) Platinum RTD ( Pt : 100 , Sensor input type Thermocouple Type J (IC) and Type K (CA) Platinum RTD ( Pt : 100 ) DIN or JIS , OFF Thermistor sensor Note: The resistance of the platinum RTD is 100 at 0°C and increases to , /°F °C/°F Platinum RTD Input Type Temperature range ­50 to 50 0.0 to 50.0 ­20 to 80 , indication °C Unit of measure 1° C or F 0 to 100 50 to 150 100 to 200 150 to 300 ­50


Original
PDF /H032E12A 1-800-55-OMRON GCTC13 E5CS-R1PX-F E5CS-R1PX E5CS-R1KJX-F data sheet omron E5CS-R1PX E5CS-Q1PX-F E5CS-Q1PX E5CS-Q1KJX-F temperature controller circuit diagram with relay 1px transistor DIP switch
2000 - Omron SPEED RELAY

Abstract: No abstract text available
Text: Temperature Sensor Modules 2 - 2 - 0 to 10V 1 to 5V 4 to 20mA RTD Pt 100 -40 to 250C , expansion modules 12 bit Analog I/O module RTD or Thermocouple temperature sensor modules Compobus/S


Original
PDF RS-232C/Peripheral G7TC-OC08 G70D-SOC16-DC24V G70D-FOC16-DC24V G79-100C G79-150C G79-200C G79-300C G79-500C G70A-ZOC16-DC24V Omron SPEED RELAY
rtd pt100 only 1 page

Abstract: DSCP20 50035-G32 NICR-NI thermocouple Resistance thermometers RTD W5W26 PT100 RTD IEC 751 PT100 resistance table circuit diagram temperature measurement rtd W5-W26RE
Text: B) TC Type B 2) RTD Ni 100 Specify: 1) RTD Pt 100 Specify Range: ° to (See , is selectable as either internal or external. Three RTD types, Pt 100 , Ni 100 , and Cu 50* can be , Model Reference Table 1 Incorporated Pt 100 0 to 60°C, Configurable >10M Input Range, RTD RTD Types: Pt 100 , Ni 100 RTD Excitation Current Input Resistance Lead Resistance Reference , Cable Configuration Software Measured Variables Limits RTD : 2, 3, or 4-wire Pt 100 , Standard


Original
PDF DSCP20 DSCP20 DSCX-887 DSCX-416 DSCX-895 RS-232C. 4-20mA rtd pt100 only 1 page 50035-G32 NICR-NI thermocouple Resistance thermometers RTD W5W26 PT100 RTD IEC 751 PT100 resistance table circuit diagram temperature measurement rtd W5-W26RE
2001 - Not Available

Abstract: No abstract text available
Text: % of span error; RTD Pt 100 , 50 Ω/lead: <0.5% of span error Radiated RF Field Influence , RTD Type and Connection: (3-wire) 100 Ω (.00385 Ω/Ω/°C) Lead Compensation: Automatic RTD , Unit Features ߜ Universal Sensor Inputs: Thermocouple, 3-Wire RTD or DC Linear (mA, mV or V) ß , Resolution: 14 bits, approximately Input Impedance: Greater than 100 MΩ resistive (except for dc mA and , Depicting Ramp and Soak Programming Sensor Break Protection for RTD and dc mV: Break detected within 2


Original
PDF CN1462 NEMA-4/IP65 RS-485 BD1600-R BD1600-DC BD1600-F BD1600-C4 P-118
rtd circuit output 10v

Abstract: PT100 RTD IEC 751 pt100 W5 basic model circuit for pt100 NICR-NI thermocouple 0,600 RTD PT-100 W26Re THERMOCOUPLE PT100 J TYPE OR K TYPE rtd frequency response NICR-NI thermocouple
Text: B) TC Type B Specify: 2) RTD Ni 100 1) RTD Pt 100 Sensor type , selectable as either internal or external. Three RTD types, Pt 100 , Cu 50*, and Ni 100 , can be interfaced , Input Range, RTD RTD Types: Pt 100 , Ni 100 RTD Excitation Current Lead Resistance Output Range Load , Interface Cable Configuration Software Table 1 Measured Variables RTD : 2, 3, or 4-wire Pt 100 , signal is only active for RTD measuring 100 at 0°C and three or four-wire connection


Original
PDF DSCP80 DSCP80 DSCX-887 DSCX-416 DSCX-895 RS-232C. rtd circuit output 10v PT100 RTD IEC 751 pt100 W5 basic model circuit for pt100 NICR-NI thermocouple 0,600 RTD PT-100 W26Re THERMOCOUPLE PT100 J TYPE OR K TYPE rtd frequency response NICR-NI thermocouple