The Datasheet Archive

Top Results (6)

Part ECAD Model Manufacturer Description Datasheet Download Buy Part
1480320005 1480320005 ECAD Model Molex Combination Line Connector,
1480320003 1480320003 ECAD Model Molex Combination Line Connector,
0348242244 0348242244 ECAD Model Molex Combination Line Connector,
0194270017 0194270017 ECAD Model Molex Combination Line Connector,
0937928425 0937928425 ECAD Model Molex Combination Line Connector,
2042234004 2042234004 ECAD Model Molex Combination Line Connector,

RE102 limit line Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1997 - RE102 limit line

Abstract: No abstract text available
Text: , MIL-STD-461D, CE102, +28 V Hot Line 100 W Load Figure 14. Radiated Emissions, MIL-STD-461D, RE102 , input conditions: 16 V­50 V dc; survives low line , high line and positive and negative transients. See , Units V V V mA mA V V V mV mV mV p-p A % VO Nom % IO max A M 52.5 85 1 OBS Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO) Output Overvoltage Protection Output Current Limit Output , 13.35 V 0.5 1.2 15 4.0 2.70 2.80 3.90 150 2.90 V mA V V µA V V 50 V dc upper limit rated for


Original
PDF MIL-STD-461D ADDC02828SA ADDC02828 C2994 MIL-STD-883, TM1014 TM2017 RE102 limit line
1995 - schematic diagram dc-dc flyback converter

Abstract: power architecture hybrid vehicles Lambda LC Schematic hybrid vehicle EMI power filter lisn audio Amp. mosfet 1000 watt TV flyback transformer 90 M 20 A pin configuration 1K variable resistor dc line EMI filter
Text: . Operational and survivable over a wide range of input conditions: 16 V­50 V dc; survives low line , high line , ) Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO) Output Overvoltage Protection Output Current Limit Output Short Circuit Current ISOLATION CHARACTERISTICS Isolation , 2.78 2.82 3.90 NOTES 1 50 V dc upper limit rated for transient condition of up to 50 ms. 16 V dc lower limit rated for continuous operation during emergency condition. Steady state and


Original
PDF MIL-STD-461D ADDC02805S C2077 schematic diagram dc-dc flyback converter power architecture hybrid vehicles Lambda LC Schematic hybrid vehicle EMI power filter lisn audio Amp. mosfet 1000 watt TV flyback transformer 90 M 20 A pin configuration 1K variable resistor dc line EMI filter
1997 - 1n5819 smd

Abstract: lambda IC 101 MIL-STD-704A RE102 ADDC02828SA ADDC02828SAKV ADDC02828SATV
Text: . Figure 12 shows the CE102 limit and the measurement taken from the +VIN line . While the measurement , : 16 V­50 V dc; survives low line , high line and positive and negative transients. See Input Voltage , Disabled Input Current OUTPUT CHARACTERISTICS2, 3 Output Voltage (VO) Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO) Output Overvoltage Protection Output Current Limit Output , upper limit rated for transient condition of up to 50 ms. 16 V dc lower limit rated for continuous


Original
PDF MIL-STD-461D ADDC02828SA 1n5819 smd lambda IC 101 MIL-STD-704A RE102 ADDC02828SA ADDC02828SAKV ADDC02828SATV
1995 - RE102 limit line

Abstract: MIL-STD-462D
Text: -461D, CE102, +28 V Hot Line 100 W Load Figure 13. Radiated Emissions, MIL-STD-461D, RE102 , Vertical , ­50 V dc; survives low line , high line , and positive and negative transients. See section entitled , V V V mV mV mV p-p A % VO Nom % IO max A M 52.5 82 4 5.025 OBS Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO) Output Overvoltage Protection Output Current Limit Output , 14.5 50 V dc upper limit rated for transient condition of up to 50 ms. 16 V dc lower limit rated for


Original
PDF MIL-STD-461D ADDC02805S ADDC02e C2077 RE102 limit line MIL-STD-462D
1998 - RE102-2

Abstract: 5962-9763401HXC ADDC02808PB ADDC02808PBKV ADDC02808PBTV CE101 RE101
Text: conditions: 16 V­50 V dc; survives low line , high line The ADDC02808PB is available in a hermetically , 16 50 Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO)5 Output Overvoltage Protection Output Current Limit Output Short Circuit Current +25°C Full Full +25°C +25°C , V 175 2.65 V µA V V 4.0 2.45 2.55 3.90 NOTES 1 50 V dc upper limit rated for transient condition of up to 50 ms. 16 V dc lower limit rated for continuous operation during emergency


Original
PDF ADDC02808PB RE102-2 5962-9763401HXC ADDC02808PB ADDC02808PBKV ADDC02808PBTV CE101 RE101
1996 - LS 1017 TRANSFORMER

Abstract: ADDC02808PB ADDC02808PBKV ADDC02808PBTV RE101 MIL-STD-462D
Text: : 16 V­50 V dc; survives low line , high line The ADDC02808PB is available in a hermetically sealed , Disabled Input Current OUTPUT CHARACTERISTICS2, 3 Output Voltage (VO) Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO)5 Output Overvoltage Protection Output Current Limit Output , 4.0 2.45 2.55 3.90 NOTES 1 50 V dc upper limit rated for transient condition of up to 50 ms. 16 V dc lower limit rated for continuous operation during emergency condition. Steady state and


Original
PDF ADDC02808PB LS 1017 TRANSFORMER ADDC02808PB ADDC02808PBKV ADDC02808PBTV RE101 MIL-STD-462D
RE102 limit line

Abstract: 461E CE102 CS101 RE102 RS103 MIL-STD461E
Text: Rise Time · 50 ms Hold Up Time · 16/75 ms minimum at 115/230 VAC Line Regulation · ±0.5% Load , reset Overload Protection · 110-150%, on primary power limit , auto recovery Short Circuit Protection , Immunity Safety Approvals · MIL-STD-461E, CE102, RE102 · MIL-STD 461E, CS101, 114, 115, 116 & RS103


Original
PDF MIL-STD-461E MCM60US28-NI. 18-Jul-08 RE102 limit line 461E CE102 CS101 RE102 RS103 MIL-STD461E
1996 - c2183

Abstract: No abstract text available
Text: Hot Line 100 W Load Figure 14. Radiated Emissions, MIL-STD-461D, RE102 , Vertical Polarity, 100 W , dc; survives low line , high line 5. High reliability; NAVMAT derated 6. Protection features include , p-p A % VO nom % IO max A M 52.5 45 1 8.00 OBS Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO)5 Output Overvoltage Protection Output Current Limit Output Short Circuit , 50 V dc upper limit rated for transient condition of up to 50 ms. 16 V dc lower limit rated for


Original
PDF ADDC02808PB ADDC02808PB C2183 MIL-STD-883, TM1014 TM2017
2012 - RE-01

Abstract: No abstract text available
Text: CE101 Low Frequency Conducted Emissions. Limit line (in red) is the `Submarine Applications DC Curve'. Figure 4: MIL-STD-461E Method CE102 High Frequency Conducted Emissions. Limit line (in red) is the `Basic Curve'. Figure 5: MIL-STD-461E Method RE101 Low Frequency Radiated Emissions. Limit line (in red) is , . Product # MQME-28-P Phone 1-888-567-9596 Figure 6: MIL-STD-461E Method RE102 High Frequency Radiated Emissions. Limit line (in red) is the 5Submarine External to Pressure Hull Curve. Doc.# 005-2ME028P Rev. E


Original
PDF MQME-28-P 500kHz MQME-28-P 005-2ME028P RE-01
2012 - Not Available

Abstract: No abstract text available
Text: 50W output. Limit line (in red) is the `Submarine Applications DC Curve'. Figure 4: MIL-STD , . Limit line (in red) is the `Basic Curve'. Figure 5: MIL-STD-461E Method RE101 Low Frequency Radiated Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Standard , MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Submarine External to , CE102 CS101 CS114 CS115 CS116 RE101 RE102 RS101 RS103 Most Stringent Limit Listed Class A5


Original
PDF MQHE-28-P 500kHz MQHE-28-P
2012 - Not Available

Abstract: No abstract text available
Text: -28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Submarine Applications DC Curve , MQHL-28-05S at 50W output. Limit line (in red) is the `Basic Curve'. Figure 5: MIL-STD-461E Method RE101 Low Frequency Radiated Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit , Radiated Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the , CE102 CS101 CS114 CS115 CS116 RE101 RE102 RS101 RS103 Most Stringent Limit Listed Class A5


Original
PDF MQHE-28E-P 500kHz MQHE-28E-P
1996 - 12 v 100w power amp diagram

Abstract: 12/24 v dc-dc converter schematic schematic diagram dc-dc flyback converter 12 v 100w power amp audio Amp. mosfet 1000 watt MIL-STD-704D. Input Transient 8 pin SMD audio transformer DC TO AC CONVERTER MIL-STD-704D MIL-STD-1275
Text: . Conducted Emissions, MIL-STD-461D, CE101, +28 V Hot Line 100 W Load 90 130 RADIATED EMISSIONS RE­102 , -461D, CE102, +28 V Hot Line 100 W Load LISN RE102 ­2 +VOUT 82nF 0.1µF 2µF 1/4 82nF ­VIN , ; survives low line , high line , and positive and negative transients 4. High reliability; NAVMAT derated 5 , ) VI VI +25°C I Full VI Full VI Line Regulation (12 V) +25°C VI Line Regulation , Limit (12 V/15 V) Output Short Circuit Current (12 V/15 V) +25°C V +25°C I ISOLATION


Original
PDF ADDC02812DA) ADDC02815DA) MIL-STD-461D ADDC02812DA/ADDC02815DA C2133 12 v 100w power amp diagram 12/24 v dc-dc converter schematic schematic diagram dc-dc flyback converter 12 v 100w power amp audio Amp. mosfet 1000 watt MIL-STD-704D. Input Transient 8 pin SMD audio transformer DC TO AC CONVERTER MIL-STD-704D MIL-STD-1275
1997 - 70-100W

Abstract: P4855 ADDC02812DA ADDC02812DAKV ADDC02812DATV ADDC02815DA diagram electric sources lambda
Text: 90 70 LIMIT 28VDC 50 30 0.01 0.1 0.1 1 FREQUENCY ­ MHz 50 30 RE102 ­2 10 , equipment. Figure 14 shows the CE102 limit and the measurement taken from the +VIN line . While the , ; survives low line , high line , and positive and negative transients 4. High reliability; NAVMAT derated 5 , Regulated Output Voltage (­15 V) VI VI +25°C I Full VI Full VI Line Regulation (12 V) +25°C V Line Regulation (15 V) +25°C V Load Regulation (12 V) +25°C V Load Regulation (15


Original
PDF ADDC02812DA) ADDC02815DA) MIL-STD-461D ADDC02812DA/ADDC02815DA VCO02 C2133a 70-100W P4855 ADDC02812DA ADDC02812DAKV ADDC02812DATV ADDC02815DA diagram electric sources lambda
1998 - Lambda Electronics

Abstract: ADDC02803SC ADDC02803SCKV ADDC02803SCTV ADDC02805SA schematic power supply circuit diagram Lambda CE102
Text: LIMIT 28VDC 70 50 30 RE102 ­2 10 50 0.1 1 FREQUENCY ­ MHz ­30 10 Figure , the CE102 limit and the measurement taken from the +VIN line . While the measurement taken from the input return line is slightly different, both comfortably meet the MIL-STD-461D, CE102 limit , survivable over a wide range of input conditions: 16 V­50 V dc; survives low line , high line and positive , Output Voltage (VO) Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO


Original
PDF ADDC02803SC/ADDC02805SA ADDC02805SA) ADDC02803SC) MIL-STD-461D ADDC02803SC ADDC02805SA Lambda Electronics ADDC02803SC ADDC02803SCKV ADDC02803SCTV ADDC02805SA schematic power supply circuit diagram Lambda CE102
1996 - Not Available

Abstract: No abstract text available
Text: the CE102 limit and the measurement taken from the +VIN line . While the measurement taken from the input return line is slightly different, both comfortably meet the MIL-STD-461D, CE102 limit . CS101 , of input conditions: 16 V­50 V dc; survives low line , high line , and positive and negative transients , Regulated Output Voltage (­15 V) VI VI +25°C I Full Full Line Regulation (12 V) Line Regulation (15 V) Load , Protection (12 V) Output Overvoltage Protection (15 V) Output Current Limit (12 V/15 V) Output Short Circuit


Original
PDF ADDC02812DA) ADDC02815DA) MIL-STD-461D ADDC02812DA/ADDC02815DA C2133
1997 - C3056

Abstract: ADDC02803SC ADDC02803SCKV ADDC02805SA
Text: the CE102 limit and the measurement taken from the +VIN line . While the measurement taken from the input return line is slightly different, both comfortably meet the MIL-STD-461D, CE102 limit , input conditions: 16 V­50 V dc; survives low line , high line and positive and negative transients. See , 52.5 55 90 0.85 2.0 V V mA mA Line Regulation Load Regulation Output Ripple/Noise4 Output Current (IO) Output Overvoltage Protection Output Current Limit Output Short Circuit Current +25°C


Original
PDF ADDC02803SC/ADDC02805SA ADDC02805SA) ADDC02803SC) MIL-STD-461D C3056 ADDC02803SC ADDC02803SCKV ADDC02805SA
2012 - Not Available

Abstract: No abstract text available
Text: CE101 Low Frequency Conducted Emissions. Limit line (in red) is the `Submarine Applications DC Curve'. Figure 4: MIL-STD-461E Method CE102 High Frequency Conducted Emissions. Limit line (in red) is the `Basic Curve'. Figure 5: MIL-STD-461E Method RE101 Low Frequency Radiated Emissions. Limit line (in red) is , . Product # MQME-28E-P Phone 1-888-567-9596 Figure 6: MIL-STD-461E Method RE102 High Frequency Radiated Emissions. Limit line (in red) is the 5Submarine External to Pressure Hull Curve. Doc.# 005-0005135 Rev. D


Original
PDF MQME-28E-P 500kHz MQME-28E-P
2011 - Not Available

Abstract: No abstract text available
Text: -28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Submarine Applications DC Curve , MQHL-28-05S at 50W output. Limit line (in red) is the `Basic Curve'. Figure 5: MIL-STD-461E Method RE101 Low Frequency Radiated Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit , Radiated Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the , CE102 CS101 CS114 CS115 CS116 RE101 RE102 RS101 RS103 Most Stringent Limit Listed Class A5


Original
PDF MQHE-28E-P 500kHz MQHE-28E-P
2010 - MIL-STD-461E, RS103

Abstract: No abstract text available
Text: Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Submarine , -28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Basic Curve'. Figure 5: MIL-STD , . Limit line (in red) is the `Standard Curve' from MIL-STD461C Method RE01, which is more strict than all RE101 limits. Product # MQHE-28-P Phone 1-888-567-9596 Figure 6: MIL-STD-461E Method RE102 High Frequency Radiated Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red


Original
PDF MQHE-28-P 500kHz MQHE-28-P MIL-STD-461E, RS103
2010 - ld-sw

Abstract: mqme-28-p RTCA DO-160E section 8
Text: -461E Method RE102 High Frequency Radiated Emissions. Limit line (in red) is the 5Submarine External to , Conducted Emissions. Limit line (in red) is the `Submarine Applications DC Curve'. Figure 4: MIL-STD-461E Method CE102 High Frequency Conducted Emissions. Limit line (in red) is the `Basic Curve'. Figure 5: MIL-STD-461E Method RE101 Low Frequency Radiated Emissions. Limit line (in red) is the `Standard Curve , provided by this filter when the source impedance is 50 to chassis ground on each input line . The MQME


Original
PDF MQME-28-P 500kHz 005-2ME028P ld-sw mqme-28-p RTCA DO-160E section 8
2010 - MIL-STD-461 CS101

Abstract: RTCA DO-160E curve b ce07 ld-sw MQHE-28E-P-X-HB 1275d DO-160E MQHE-28E-P MIL-HDBK-704-8 MQHE-28E-P-W-HB
Text: with a MQHL-28-05S at 50W output. Limit line (in red) is the `Submarine Applications DC Curve , MQHL-28-05S at 50W output. Limit line (in red) is the `Basic Curve'. Figure 5: MIL-STD-461E Method RE101 Low Frequency Radiated Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Standard Curve' from MIL-STD461C Method RE01, which is more strict than all RE101 , with a MQHL-28-05S at 50W output. Limit line (in red) is the `Submarine External to Pressure Hull


Original
PDF MQHE-28E-P 500kHz 28Vin MIL-STD-461 CS101 RTCA DO-160E curve b ce07 ld-sw MQHE-28E-P-X-HB 1275d DO-160E MQHE-28E-P MIL-HDBK-704-8 MQHE-28E-P-W-HB
RTCA DO-160

Abstract: EMI FILTER MIL-STD-461E MIL-STD-461 CS101 aall ce07 ce07 series ld-sw MIL-STD-1275 MIL-STD-461C CS116
Text: RE102 High Frequency Radiated Emissions. Limit line (in red) is the `Submarine External to Pressure , Conducted Emissions. Limit line (in red) is the `Submarine Applications DC Curve'. Setup described on Page 7. Figure 4: MIL-STD-461E Method CE102 High Frequency Conducted Emissions. Limit line (in red , Frequency Radiated Emissions. Limit line (in red) is the `Standard Curve'from MIL-STD-461C Method RE01 , ground on each input line . The MQME-28-P EMI filter includes a large bulk capacitor (also X7R) with a


Original
PDF MQME-28-P 500kHz 005-2ME028P RTCA DO-160 EMI FILTER MIL-STD-461E MIL-STD-461 CS101 aall ce07 ce07 series ld-sw MIL-STD-1275 MIL-STD-461C CS116
2010 - RTCA DO-160E curve b

Abstract: No abstract text available
Text: Conducted Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the , of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Basic Curve , -28-05S at 50W output. Limit line (in red) is the `Standard Curve' from MIL-STD461C Method RE01, which is , -461E Method RE102 High Frequency Radiated Emissions of the MQHE-28-P filter with a MQHL-28-05S at 50W output. Limit line (in red) is the `Submarine External to Pressure Hull Curve'. Doc.# 005-0005151 Rev. A 05/12


Original
PDF MQHE-28E-P 500kHz MQHE-28E-P RTCA DO-160E curve b
Not Available

Abstract: No abstract text available
Text: Hz. Internal T3.15/250 V fuse in line and neutral Output Output Voltage Output Voltage Trim , €¢ MIL-STD-461F - Ground Army, CE102. MIL-STD-461F - Ground Army, RE102 . Figure RE102 -3 fixed wing external


Original
PDF EN61000-3-2, VAC/60 BS1363A 02-Oct-12 MCS65
2012 - Not Available

Abstract: No abstract text available
Text: Figure 3: MIL-STD-461F Method CE101 Low Frequency Conducted Emissions. Limit line (in red) is the , 33nF common mode capacitors. Limit line (in red) is the `Basic Curve'. See MIL-STD-461 Compliance , Frequency Radiated Emissions. Limit line (in red) is the `Standard Curve' from MIL-STD-461F Method RE01 , Radiated Emissions. Limit line (in red) is the `Fixed Wing Internal, 25 meters Nose to Tail'. See MIL-STD , Susceptibility Radiated Emissions CE101 CE102 CS101 CS114 CS115 CS116 RE101 RE102 Most Stringent Limit Listed


Original
PDF MCOTS-F-28-T-HT 250kHz 005-IH01196 MCOTS-F-28-T-HT
Supplyframe Tracking Pixel