RBS 2106 operating weight Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2003 - RBS 2106

Abstract: RBS 2106 cabinet rbs 2106 ericsson ericsson 2106 ERICSSON RBS 2106 RBS 2106 operating weight Ericsson Base transceiver Station Ericsson tma RBS 2106 outdoor CDU-F
Text: RBS 2106 The GSM Macro Outdoor Base Station RBS 2106 is a high capacity, compact outdoor macro , member in the RBS 2000 family, RBS 2106 is to date the most powerful outdoor RBS in the world. Keeping , as operation and maintenance makes the RBS 2106 a very cost-effective solution for growing GSM , . Site space is often a limiting factor for capacity growth. The powerful RBS 2106 , included in , be replaced by one RBS 2106 . This is of major importance, since it makes it possible to reuse the


Original
PDF
2003 - RBS 2106

Abstract: ERICSSON rbs 3101 RBS 3101 rbs 2106 ericsson Ericsson BBU bbu 9500 bbu 9500 installation RBS 2106 outdoor RBS 2106 BBU 9500 ERICSSON RBS 2106
Text: ) for RBS 2106 and BBU 9500 including batteries - Max weight 1231 kg (2714 lb) for RBS 3101 and BBU , Battery Base Frame - BBU 9500 for outdoor RBS 2106 and 3101 The Battery Base Frame ­ BBU 9500 , with the outdoor cabinets RBS 2106 and RBS 3101 · A climate door including either a +24 V or -48 V , RBS Same as for the RBS IP55 Battery Backup times RBS 2106 : RBS 3101: Up to 6 h for 3 x 4 , providing battery backup for either +24 V DC or -48 V DC and supports GSM and WCDMA outdoor RBS cabinets


Original
PDF 706/BYB 705/BYB SE-126 RBS 2106 ERICSSON rbs 3101 RBS 3101 rbs 2106 ericsson Ericsson BBU bbu 9500 bbu 9500 installation RBS 2106 outdoor RBS 2106 BBU 9500 ERICSSON RBS 2106
2003 - KRY 112 75 1 dual band

Abstract: Ericsson tma KRY 112 75 1 ERICSSON TMA KRY 112 TMA ericsson 1800 ericsson BTS and antenna installation Ericsson tma kry 112 75 ERICSSON dual band tma DDTMA Tower Mounted Amplifiers ericsson
Text: Optimized for Ericsson's RBS 2102 / 2202 and RBS 2106 / 2206 · Compact casing Convincing results from , TMA + BTS fulfils ETSI requirements Mechanical specifications Dimensions (H x W x D) Weight : RF


Original
PDF
2003 - ERICSSON TMA KRY 112

Abstract: Ericsson tma ERICSSON dual band tma DDTMA Ericsson KRY 112 71 Ericsson TMA 1900 Tower Mounted Amplifiers ericsson ericsson BTS and antenna installation RBS 2106 ericsson kry 112
Text: · Optimized for Ericsson's RBS 2102 / 2202 and RBS 2106 / 2206 · Compact casing Convincing , Ericsson TMA + BTS fulfils ETSI requirements Mechanical specifications Dimensions (H x W x D) Weight


Original
PDF UL1950, ERICSSON TMA KRY 112 Ericsson tma ERICSSON dual band tma DDTMA Ericsson KRY 112 71 Ericsson TMA 1900 Tower Mounted Amplifiers ericsson ericsson BTS and antenna installation RBS 2106 ericsson kry 112
2003 - ERICSSON TMA KRY 112

Abstract: Ericsson tma ericsson kry 112 RBS 2106 KRY 112 488 kry 112 42 ERICSSON dual band tma RBS 2206 TMA ericsson Tower Mounted Amplifiers ericsson
Text: Ericsson's RBS 2106 /2206 · >30 dB attenuation at 851 MHz (SMR Tx band) · Compatible with all radio base , : Dimension (H x W x D): Volume: Weight : RF connector: DC/Alarm: Mounting: KRY 112 81 25 MHz 824­849


Original
PDF
2005 - RBS 2106

Abstract: RBS 2109
Text: 2106 COM immune CMOS technologies enable 515/500 no none VSS/COM 21064 HIN/LIN ruggedized , Operating Conditions The Input/Output logic timing diagram is shown in figure 1. For proper operation the , pulsed current IO- Output low short circuit pulsed current Rbs Bootstrap resistance


Original
PDF IRS2106 PD60241 14-Lead IRS2106D/IRS2108D/IRS2109D/Feature IRS21064D RBS 2106 RBS 2109
2000 - RBS 2401

Abstract: rbs cabinet e1 ericsson rbs RBS ericsson Ericsson Base Station ericsson gsm antenna RBS repair RBS -ericsson ericsson gsm rbs RBS ericsson 2000
Text: GSM Systems RBS 2401 RBS 2401 is a small, flexible and easily installed radio base station for GSM, with a volume of less than 20 liters, and a cabinet weight of less than 17 kg. The RBS 2401 , indoor applications. RBS 2401 enables indoor cell solutions that are easier to install and maintain, thereby cutting implementation time and operating costs. New market The slim cabinet with its sleek design builds out only 126 mm from the wall. This makes the RBS 2401 ideal for use with indoor cell


Original
PDF
2003 - RBS 2206

Abstract: CDU-F Ericsson Base transceiver Station Ericsson 2206 RBS 2202 ericsson RBS 2206 RBS 200 RBS ericsson maintenance dtru RBS 2206 ericsson
Text: RBS 2206 The GSM Macro Indoor Base Station RBS 2206 is a high capacity, small footprint indoor , member in the RBS 2000 family RBS 2206 is to date the most powerful indoor RBS in the world. Keeping the successful characteristics of the existing RBS 2000 portfolio and improving functionality as well as operation and maintenance makes the RBS 2206 the most cost-effective solution for growing GSM operators. The RBS 2000 family supports a wide range of applications ranging from extreme coverage to


Original
PDF SE-126 RBS 2206 CDU-F Ericsson Base transceiver Station Ericsson 2206 RBS 2202 ericsson RBS 2206 RBS 200 RBS ericsson maintenance dtru RBS 2206 ericsson
2001 - RBS 2102

Abstract: Ericsson TRU ericsson rbs 2000 family RBS 3G ericsson Ericsson Battery Backup System power and battery cabinet ericsson ericsson 2102 RBS 2102 installation ericsson trx receiver sensitivity RBS 2202
Text: GSM RBS 2102 The RBS 2102 is an EDGE/E-GPRS capable outdoor RBS supporting up to six , band configurations in one cabinet. The RBS 2102 is normally ground or roof mounted and provides a , for a six TRU configuration is supported. The RBS 2000 product family for Ericsson's GSM System offers the most advanced technology available. With Ericsson's wide range of RBS 2000 products, the most , environmental requirements. e Fast rollout and expansion RBS 2000 Macro allows for easy installation


Original
PDF
2001 - RBS 2202

Abstract: RBS 2202 ericsson RBS ericsson 2202 Ericsson Battery Backup System ericsson rbs 2000 family ericsson RBS 2202 power and battery cabinet ericsson Ericsson TRU RBS 2202 commissioning Ericsson Base Station DC 1800
Text: GSM RBS 2202 The RBS 2202 is an EDGE/E-GPRS capable indoor RBS supporting up to six , band configurations in one cabinet. The RBS 2000 product family for Ericsson's GSM System offers the most advanced technology available. With Ericsson's wide range of RBS 2000 products, the most , environmental requirements. e Fast rollout and expansion RBS 2000 Macro allows for easy installation with , , and SW loaded and tested before delivery. The flexible design of RBS 2000 supports a number of site


Original
PDF
RBS 2116

Abstract: RBS 2107 RBS 2106 RBS 2111 V2 RBS 2111 RBS 2102 RBS 2101 RBS 2104 RBS 2103 00F86H
Text: . RBS 4 ( RBS ) 6. 88CU74-29 2007-10-12 2003-02-17 TMP88CU74 1 INT5 , +1 n-1 n-2 n-3 n-4 a SP b b b+1 b+2 b+1 b+2 b+3 n-1 n-2 n-3 n-4 n RBS i n-5 k = i + (FFFE7). 3 - 0 (a) IMF RETI c c PC c+1 n-5 SP RBS , [RETI]/[RETN] RBS : PINTxx: . RETI VINTxx: b. DP DB PINTxx 1 ; RBS RBS + 1 / 0 115 : PINTxx: LD RBS , n ; . RETI VINTxx: c. DP DB


Original
PDF TLCS-870/X TMP88CU74FG TMP88CU74 LQFP100-P-1414-0 TMP88CU74F P-QFP80-1420-0 QFP80-P-1420-0 RBS 2116 RBS 2107 RBS 2106 RBS 2111 V2 RBS 2111 RBS 2102 RBS 2101 RBS 2104 RBS 2103 00F86H
Not Available

Abstract: No abstract text available
Text: -28 mA Tem perature Operating Temperature, am bient. -25 to +85 °C c a s e , OUTPUT CIRCUIT AGND 2-106 fl24flTl? 0 0 0 4 1 4 1 b30 ■CLOCK INPUT DG ND 4755 , , Nominally -1 V V rbf Reference Voltage Force Bottom, Nominally -2 V V rbs Reference Voltage , Data Ready Bank A DRB Data Ready Bank B NDRB V ee V RBS U U U U U U U U U U L T D U U U U


OCR Scan
PDF SPT7755 SPT7755AIK SPT7755BIK
2003 - BBS 2202

Abstract: Ericsson BBS 2202 Ericsson BBS ericsson TMR 9202 ericsson RBS 2202 RBS 2202 Ericsson Base Station TMR 9202 Ericsson Installation dxx MINI-LINK ericsson
Text: installed as standard. Site Solution for Ericsson's RBS 2202 Prefabricated cables are delivered with TMR 9202, for easy installation together with the Ericsson base station RBS 2202 and the power cabinet , microwave solution, providing transmission from 2 up to 155 Mbit/s, operating within the 7 to 38 GHz , ) 1650x600x400 mm Weight Fully equipped 120 kg Operational temperature +5 to +40 Standards and


Original
PDF E1/75 E1/120 1650x600x400 SE-164 BBS 2202 Ericsson BBS 2202 Ericsson BBS ericsson TMR 9202 ericsson RBS 2202 RBS 2202 Ericsson Base Station TMR 9202 Ericsson Installation dxx MINI-LINK ericsson
RBS 6000

Abstract: rbs 5000 RBS 6000 -ericsson RBS 200 RBS-33-SD RBS-34 RBS -ericsson RBS33 RBS-37 RMS-68
Text: PART NO. "H" RBS -3R RBS -19 RBS -20 RBS -29 RBS -32R RBS -1 RBS -5 RBS -6 RBS -11 RBS -24 RBS -34 RBS -35 RBS -41 RBS -44 RBS -72 RBS -2 RBS -8 RBS -12 RBS -15 RBS -22 RBS -27 RBS -37 RBS -39 RBS -40 RBS -30 RBS -17 RBS -4 RBS -36 RBS -18 RBS -33-SD RBS -7 RBS -10 "H" "H" "W" "W" , . PART NO. RBS -33-SD AND RBS -10 AVAILABLE IN CLEAR ONLY. 3. ADHESIVE: RUBBER ( RMS-68). 4. LIGHTER , FILE #: RBS SHEET: 1 OF 1 RE: SHEET SIZE: B RICHCO, INC. DWN: SM DT: 08/12/04 APP: DJZ


Original
PDF RBS-19 RBS-20 RBS-29 RBS-32R RBS-11 RBS-24 RBS-34 RBS-35 RBS-41 RBS-44 RBS 6000 rbs 5000 RBS 6000 -ericsson RBS 200 RBS-33-SD RBS-34 RBS -ericsson RBS33 RBS-37 RMS-68
2010 - rbs 3216

Abstract: RBS 6000 POWER RATING RBS10 RBS Series rbs 5000 RBS-12 rbs 6000
Text: Document No TRBS-XXOS002B 2010/08/04 1/10 Anti Sulfuration Chip Resistors ( RBS series Standard ) Issued date page 1. Scope : This specification applies for the RBS series of chip , Ceramic Substrate Inner electrode 3. Type Designation: RBS Product Code 10 Size B Tolerance T Packaging P TCR 1001 Nominal Resistance RBS : Anti Sulfuration Power Rating 04-0402 , Chip Resistors ( RBS series Standard ) Issued date page 4. Dimensions: 1001 UNIT: mm


Original
PDF TRBS-XXOS002B 1/16W 1/10W rbs 3216 RBS 6000 POWER RATING RBS10 RBS Series rbs 5000 RBS-12 rbs 6000
2007 - sustain circuits for plasma tv

Abstract: plasma display address electrode driving sustain driver for plasma tv igbt for plasma tv circuit for driving address electrodes PDP igbt display plasma heat sink design guide, IGBT BD-2249 pdp driver igbt pdp pulse module ic
Text: operating a fullbridge configuration as shown in Fig.5. This schematic diagram is conventional Weber , Sustain circuit : Q1~2, Q5~6, D1~2, D5~6 The sustain block is operating as full-bridge and the energy recovery block is operating leading and lagging energy for give-and-take charges to the PDP cells with the assistance of sustain operating . Figure 6. Driving sequence during sustain period The waveform in , (9) VIN H (10) VCC H RIN SUS_UP DZBS RBS DBS CBS CBS ERC (11) VB H (12) G H


Original
PDF
2007 - CiPoS IKCS12F60AA

Abstract: DC MOTOR SPEED CONTROL USING IGBT capacitor 100nf 400v VF 3 phase converter IGBT 3 phase IGBT gate driver IGBT DRIVER SCHEMATIC 3 PHASE temperature controller h bridge 15V 3 phase IGBT gate driver 6ED003L06-F IGBT cross reference "AC Motors"
Text: Dbs1Dbs3 Rbs VDD (22) VCC /HIN1 (15) /HIN2 (16) /HIN3 (17) /HIN1 /HIN2 /HIN3 /LIN1 , R2 Rbs RH1-RH3 RL1-RL3 RTS C1 C2 CbsH1-CbsH3 Dbs1-Dbs3 RTS R2 EN (24) *) C1 R1 , Operating temperature control PCB max Tstg Storage temperature range typ - 125 - °C , mounting surface NMC - - 150 N/mm² Weight mP - 17 - g Creepage distance , 35 - W Operating junction temperature range IGBT Diode TvjI TvjD -40 -40 -


Original
PDF IKCS12F60AA IKCS12F60AB IKCS12F60AA, 6EDL003L06-F CiPoS IKCS12F60AA DC MOTOR SPEED CONTROL USING IGBT capacitor 100nf 400v VF 3 phase converter IGBT 3 phase IGBT gate driver IGBT DRIVER SCHEMATIC 3 PHASE temperature controller h bridge 15V 3 phase IGBT gate driver 6ED003L06-F IGBT cross reference "AC Motors"
Tapeswitch Corporation

Abstract: DA-12 LS Contactor
Text: , unless submerged or in continuous contact. Operating Temperature 0 °F to 120 °F (­18 °C to 50 °C , , will withstand continuous body weight . 1.5" diameter round, or 1.0" x .75" rectangle. .188" thick , . (Specify length). Type RB-S Road Switch Type RB-S features the same design and functional versatility


Original
PDF 455mm) 610mm) Tapeswitch Corporation DA-12 LS Contactor
2007 - IKCS22F60AA

Abstract: No abstract text available
Text: ) CbsH1 CbsH2 CbsH3 Dbs1Dbs3 Rbs VDD (22) VCC /HIN1 (11) /HIN2 (12) /HIN3 (13 , D1-D6 R1 R2 Rbs RH1-RH3 RL1-RL3 RTS C1 C2 CbsH1-CbsH3 Dbs1-Dbs3 22 A @ 25°C/ 600V 22 A @ , not stated otherwise) Module Section Description Condition Symbol Operating temperature , °C Ptot 65 W Operating junction temperature range IGBT Diode TvjI TvjD -40 … 150 , 10 TJ,IC - 125 3 Operating junction temperature 1 2 3 V Monitored by pin 20


Original
PDF IKCS22F60AA 6EDL003L06-F IKCS22F60AA
2008 - rbs 3216

Abstract: rbs 5000 RBS-10 RBS Series RBS04
Text: Document No TRBS-XXOS001A 2008/1/16 1/10 Anti Sulfuration Chip Resistors ( RBS series Standard ) Issued date page 1. Scope : This specification applies for the RBS series of chip , Substrate Inner electrode 3. Type Designation: RBS Product Code 10 Size B Tolerance T Packaging P TCR 1001 Nominal Resistance RBS : Anti Sulfuration Power Rating 04-0402(1005) 1 , Anti Sulfuration Chip Resistors ( RBS series Standard ) Issued date page 4. Dimensions: 1001


Original
PDF TRBS-XXOS001A 1/16W 1/10W rbs 3216 rbs 5000 RBS-10 RBS Series RBS04
SPS60

Abstract: alcoa adss fiber optic cable RBS 2204 lt 6224 alcoa fujikura optical ground wire gw 340 Alcoa Fujikura ADSS alcoa fujikura fiber optic cable alcoa adss fiber optic cable weight Installation guide for RBS
Text: Diameter Weight RBS Note: Custom designs available TYPICAL REEL LENGTHS NR68.34.35* Item , )² sec Total Conductor Area Overall Diameter Weight Sag10TM Chart Number RBS in , conductivity, short circuit rating, strength, and weight ratings to meet even the strictest applications , DESIGN DESIGN FEATURES High fiber count package with reduced diameter and weight (49 to 288 fibers , OPT-GW size (Strand Area/O.D.) Total Conductor Area Overall Diameter Weight Sag10TM Chart


Original
PDF 1-800-AFL-FIBER. SPS60 alcoa adss fiber optic cable RBS 2204 lt 6224 alcoa fujikura optical ground wire gw 340 Alcoa Fujikura ADSS alcoa fujikura fiber optic cable alcoa adss fiber optic cable weight Installation guide for RBS
rbs ericsson element manager

Abstract: ericsson base station controller Ericsson Base transceiver Station rbs element manager ericsson bts operation and maintenance Ericsson Base Station Ericsson RBS, spare parts Ericsson RBS element manager installation RBS ericsson maintenance byb 501
Text: network server (RNS); · the radio base station ( RBS ); · the BSS gateway (GW); · the real-time IP , service Network management system Operation and maintenance OS PDH PHB PM PPP QoS RBS RFC RLC RNS SCB-RP SCCP SGSN SNM SS7 STM TCP TDMA TRC TRX UDP UMTS UTRAN WAN Operating system , Ericsson Review No. 4, 2000 RBS The radio base station, which includes radio transmission and , RBS RBS RBS Gb RBS RBS IP network Figure 1 System architecture. nication are


Original
PDF EGPRS-136) rbs ericsson element manager ericsson base station controller Ericsson Base transceiver Station rbs element manager ericsson bts operation and maintenance Ericsson Base Station Ericsson RBS, spare parts Ericsson RBS element manager installation RBS ericsson maintenance byb 501
RA003

Abstract: 0x0003B 0x0003A 16A2 RA002 0X00007
Text: (PSW) 1.1.4 · (JF) · (ZF) · (CF) · (HF) · (SF) · (VF) · ( RBS ) 7 SFR 0x0003F , HF SF VF RBS - / [JR cc, a], [JRS cc, a] cc cc T True JF , POP PSW ; PSW LD A, (0x3F) ; A PSW LD RBS , 1 ; PSW RBS 1 (BANK1 ) LD RBS , 0 ; PSW RBS 0 (BANK0 ) LD PSW, 0x02 ; PSW RBS 1 (BANK1 0 ) LD PSW, 0x00 ; PSW RBS 0 (BANK0 0 ) LD PSW,n LD PSW,n LD RBS ,0 LD RBS ,1 (0x3F


Original
PDF TLCS-870/C1 TLCS-870/C1 TLCS-870/C RA003 0x1FF80 0xFF80) RA003 0x0003B 0x0003A 16A2 RA002 0X00007
2008 - RBS 2111

Abstract: RBS -ericsson 16A2 RA001 0x0003B
Text: Instruction register PSW Flags RBS A W A C B E D E H L H , Carry Flag (HF) · Sign Flag (SF) · Overflow Flag (VF) · Register Bank Selector ( RBS ) Dedicated , VF RBS - The PSW consists of seven bits of status information that are set or cleared by CPU operations. The flags except RBS and HF can be specified as a condition code (cc) in conditional jump , , (0x3F) ; Loads the PSW into A. (5) LD RBS , 1 ; Sets RBS in the PSW. (Switches to Bank 1


Original
PDF TLCS-870/C1 TLCS-870/C1 TLCS-870/C 16-bit 16-bit 0x1FF80 0xFF80) 0x1E846 RBS 2111 RBS -ericsson 16A2 RA001 0x0003B
d6406

Abstract: rbs 600 RBS 2000 power supply dbe dbs db4 db3 db2 db1 db0
Text: 14 13 ZD = 1 2 = 3 = 3 = 3 D E E E E Q E E E E E E E E · DGND V rb V rbs Ü E t · c , ) CLK V rbs c= = C l c z : c rz c = t = 5 6 7 ê 9 10 11 12 R1 AGND V |N AV qd R2 R3 V , Internal Reference Bottom of Reference Digital Ground R3 R2 AV dd V ,N AGND R1 V rbs V rb DGND , ref R l Rtco V rts V rbs a V qd V V AGND 1.0 1400 2000 4 1 AV qq V Q V ref = V rt - V rb ppm/°C V V V rt V rb connected to V r t s & connected to V Rbs ANALOG INPUT2 Input


OCR Scan
PDF 10-Bit XRD6406 10-Bit, XRD6406 XRD6406, d6406 rbs 600 RBS 2000 power supply dbe dbs db4 db3 db2 db1 db0