The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LM134H-3 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN
LM134H-6 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN
LTC2997IDCB#PBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C
LTC2997CDCB#PBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C
LTC2997HDCB#PBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: High
LTC2997IDCB#TRMPBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C

Pt 100 sensor connection Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2004 - PT100 standard IEC 60751 accuracy

Abstract: 1XPt100 pt100 temperature sensor circuit diagram sensytemp PT-100 ABB Pt 100 sensor connection DIN EN 60751 Pt100 3 wire pt 250 temperature sensor PT100 ABB datasheet
Text: Technical data Sensor 1 x Pt 100 Sensor 1 x Pt 100 or 2 x Pt 100 Standard, tolerance EN 60751 , Material Plastic, ABS Technical data Color Light grey Sensor 1 x Pt 100 Dimensions 80 mm x , : air ducts, air shafts Technical data Sensor 1 x Pt 100 Standard, tolerance EN 60751 (IEC 60751 , Measuring winding 1 x Pt 100 Connection head Type B (also with integrated transmitter) Standard , automation, machine construction and environmental engineering Different output signals ­ Pt 100 signal


Original
PDF
2010 - M452A1006

Abstract: M4450A1009 honeywell ml7420a3006 ML7420A DN100 PN16 honeywell M7420A CE0085AR0013 V5077 VF20T M7420A
Text: thermostats Sensor Applications Sensors 1-15 3-5 6-4 5-2 7-9 Signal modules Small linear , input signal 2- pt Additional description Actuator supplied with mounting clip (MT-CLIP) and M30 , , V2000, V2464, V2474, VSO. For thermostatic radiator valves with connection size: M30 x 1,5. 11 , mm; 90 N Cable length (m) 1 3 1 Type MT010-N MT010-3MN 2 Actuator 3- pt for terminal , indicator Stem force 90 N Power supply 24 Vac; 0,7 VA Control input signal 3- pt Stroke


Original
PDF D-71101 EN3B-0260GE51 R0110 M452A1006 M4450A1009 honeywell ml7420a3006 ML7420A DN100 PN16 honeywell M7420A CE0085AR0013 V5077 VF20T M7420A
2004 - hy 214

Abstract: PT-100 ABB food and beverage stock sheet pt 100 temperature sensor abb sensytemp hy sensytemp milk sensor PT 100 sensor installation sensy sensytemp us r
Text: NE 21 CE conform Connection diagram 1 x Pt 100 , 3-wire circuit 2 x Pt 100 , 2-wire circuit , TSHY (SensyTemp HY R-1E) Sensor smooth, without threaded compression fitting 1 x Pt 100 , EN 60751, class A, 3-wire circuit Sensor nominal length N = 100 mm N = 250 mm N = 450 mm 2 x Pt 100 , EN 60751, class B, 2-wire circuit Sensor nominal length N = 100 mm N = 250 mm N = 450 mm 1 x Pt 100 , EN 60751 , -5E) Sensor with fixed flange for "inline" mounting 1 x Pt 100 , EN 60751, class A, 3-wire circuit Flange for


Original
PDF
2013 - Honeywell M6531A1007

Abstract: TP939B1002 honeywell M7535A1001 T7560C1006 Honeywell V5078B T7414A1019 Delta Electronics dps 730 T7460B1009 MT4-230-NC C7085A1006
Text: actuators Rotary valves 5-14 7-5 6-9 1-15 3-5 Safety thermostats Sensor Applications Sensors , STB70130 STG12- 100 STU25 STU32 STW+TR 6-3 6-3, 6-4 3-12, 3-13 3-12 6-6 T7460D1005 T7460E1002 , 2- pt Additional description Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 , connection size: M30 x 1,5. Protection class 24 Vac; 2 VA Control input signal 0.10V= Stroke , Actuator 3- pt for terminal unit/radiator valves, 2,5 mm 90 N, M7410A 3 Electrical actuator floating


Original
PDF 20/38mm Honeywell M6531A1007 TP939B1002 honeywell M7535A1001 T7560C1006 Honeywell V5078B T7414A1019 Delta Electronics dps 730 T7460B1009 MT4-230-NC C7085A1006
1999 - RTD PT-300

Abstract: kty PT-100 IBS sl 24 BK-T RTD PT-100 CU 53 k 0538 thermocouple k 900 lg PT 2000 temperature sensor ,kty81 application note KTY81
Text: Sensor Type RTD-R0 Code (Hex.) Pt 100 , Ni 100 0A 0 00 Not permissible Pt 120, Ni 120 , 0000hex) Desired Operating Mode Pt 100 DIN sensor and 0.1°C / LSB 0A00hex Pt 100 SAMA sensor and , with encapsulated sensors Sensor types that can be used (RTD) Pt 100 , Pt 1000, Ni., Cu., KTY , Capacitor 2 5425B IBSL BOX TEMP 2/2 M12 Sensor Connection 0 2 0 1 1 2 IN O U T , 255 FF Not permissible RTD-R0 is the sensor resistance at 0°C (32°F). This value is 100 for


Original
PDF 5425B SAC-4P-M12MS/1 SAC-4P-M12MS/3 SAC-4P-M12MS/5 SAC-4P-M12MR/1 SAC-4P-M12MR/3 SAC-4P-M12MR/5 RTD PT-300 kty PT-100 IBS sl 24 BK-T RTD PT-100 CU 53 k 0538 thermocouple k 900 lg PT 2000 temperature sensor ,kty81 application note KTY81
2000 - Pt 1000 sensor connection in s7 300

Abstract: MCR-PT100-I MCR-PT100-I-DC Pt 100 sensor connection SIMULATOR 4.20 mA PT 4107 PT100-Simulator MCR-PT100-U-DC phoenix contact MCR R I 4v PT-100 temperature transducer
Text: transducers convert the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into electrically , Supply current ( PT 100 ) Connection method PT 100 (IEC 751/EN 60 751); 2-, 3-, 4-wire technology , MCR-PT100-U-DC Input Temperature range Supply current ( PT 100 ) Connection method PT 100 (IEC 751/EN 60 , Temperature Measuring Transducers for PT 100 ­ MCR-PT100-. 3. Connection and Operating Instructions ld , distances between PT 100 sensor and MCR module for equal cable resistances (RL1 = RL2 = RL3). Please note


Original
PDF MCR-PT-100 PT-100 PT100/I Pt 1000 sensor connection in s7 300 MCR-PT100-I MCR-PT100-I-DC Pt 100 sensor connection SIMULATOR 4.20 mA PT 4107 PT100-Simulator MCR-PT100-U-DC phoenix contact MCR R I 4v PT-100 temperature transducer
TH02-Ex

Abstract: TR04-Ex IEC 60 751 sensytemp AGLHD DIN 3852 th02 PT100 temperature sensor ABB PT100 IEC 751 pt100 atex
Text: rough environmental conditions. In connection with special insets this sensor may be supplied as , Class 2 EN/IEC 60 584 4) G Class 1 EN/IEC 60 584 4) H Measuring inset 1 x Pt 100 , 2-wire operation temperature -200.600 °C A 1 x Pt 100 , 3-wire operation temperature -200.600 °C B 1 x Pt 100 , 4-wire operation temperature -200.600 °C C 2 x Pt 100 , 2-wire operation temperature -200.600 °C 5) D 2 x Pt 100 , 3-wire operation temperature -200.600 °C 6) E 1 x Type K (Ni-CrNi) H


Original
PDF
2006 - th02-ex

Abstract: transmitter TH02-Ex V11518 tH02 abb SMART temperature Transmitter 3KDE115040R4501 tag 8530 TH02 transmitter PT-1000 sensor prometer
Text: programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11-8.19 EN Connection diagram , , Pt 100 (RTD), thermocouples, electrical isolation Input ­ Resistance thermometer (2-, 3-, 4 , Temperature Transmitter TH02/TH02-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation , mV Resistance Resistance thermometer (IEC 751, JIS, SAMA) n · Pt 100 /Ni 100 to Pt 1000/Ni 1000 , > 5 k Voltage measurement > 5 k Input filter 50/60 Hz Internal reference junction Pt 100 , via


Original
PDF TH02/TH02-Ex th02-ex transmitter TH02-Ex V11518 tH02 abb SMART temperature Transmitter 3KDE115040R4501 tag 8530 TH02 transmitter PT-1000 sensor prometer
1999 - Not Available

Abstract: No abstract text available
Text: No. Typical connection for sensors such as the CY7 series. The connection points (A) are made close to the sensor in the case of 4-lead measurement, and near or at the instrumentation for a 2-lead measurement. Generally, the 4-lead connection is preferred. PT -102 PT -103 PT -111 Description Sensor , 2 x 20.3 mm (250 mg) Sensor , 1.8 x 12.1 mm (120 mg) Sensor , 1.8 x 5 mm (52 mg) To Order , Platinum Resistance Sensors and Silicon Diode Accessories PT -111 PT -103 PT -102 Shown


Original
PDF PT-111 PT-103 PT-102 CY82-4SL CY82-P1 CY82-P2 CY82-P3
2001 - Not Available

Abstract: No abstract text available
Text: No. Typical connection for sensors such as the CY7 series. The connection points (A) are made close to the sensor in the case of 4-lead measurement, and near or at the instrumentation for a 2-lead measurement. Generally, the 4-lead connection is preferred. PT -102 PT -103 PT -111 Description Sensor , 2 x 20.3 mm (250 mg) Sensor , 1.8 x 12.1 mm (120 mg) Sensor , 1.8 x 5 mm (52 mg) To Order , Platinum Resistance Sensors and Silicon Diode Accessories PT -111 PT -103 PT -102 Shown


Original
PDF PT-111 PT-103 PT-102 CY82-4SL CY82-P1 CY82-P2 CY82-P3
2014 - Not Available

Abstract: No abstract text available
Text: , third-party sensors with 4.20 mA 0 to 10 V, Pt 100 , Pt 1000 Order No. 2 sensor inputs board 1 2 , connection cable with open ends 0604 0102 Temperature probe cable Pt 100 , Class A, length: 150 mm, Ã , : 0601 4005 sensor length 220 mm Options for DS 400 Option: Integrated data logger for 100 million , mA 0 to 10 V, Pt 100 , Pt 1000 73 Flow DS 400 - chart recorder for all relevant parameters , Current meters 4.20 mA 0.20 mA 0.10 V Pulse Pt 100 Pt 1000 Thirdparty sensors with RS


Original
PDF
2014 - PT-1000 sensor chart table

Abstract: No abstract text available
Text: resistance (0.10 V / 30 V) 0.10 V 0.5 mV ± 2 mV ± 0.05 % RTD Pt 100 Measuring range , 4.20 mA 0.20 mA 0.10 V Pulse Pt 100 Pt 1000 20 www.cs-instruments.com Pressure , output could be connected: 4-20 mA, 0-20 mA | 0-1 V / 0-10 V / 0-30 V | Pt 100 (2- or 3-wire), Pt 1000 , www.cs-instruments.com Chart recorder Easy operation via touch screen sensor Technical data DS 400 mobile , : 2 x 2 sensor inputs for digital or analogue sensor signals Interface: the respective inner


Original
PDF
2006 - EMERSON PT 100 RESISTANCE THERMOMETER

Abstract: Pt 100 RTD Siemens Siemens PT100 temperature sensor RTD tmt 112 Wiring Diagram pt-100 siemens DXR275 Siemens PT100 temperature sensor din iec 60751 Pt 100 RTD wiring Siemens PT-1000 RTD 3 wire RTD PT-100
Text: with the following default configuration: Pt 100 sensor , measuring range 0°C . + 100 °C, 3 , : Internal ( Pt 100 ) Reference junction accuracy: ±1 K Millivolt sensor (mV) According to ASTM E988 2 , supplied with the following default configuration: Pt 100 sensor , measuring range 0°C . + 100 °C, 3 , www.phoenixcontact.com/salesnetwork 1 MCR-FL-TS-LP-I-EX Input Signals Designation Pt 100 10 K -60°C . , Ni 500 ­ 10 K According to IEC 60751 Ni 100 ­ -200°C . +250°C Pt 1000 ­ ­


Original
PDF
2000 - temperature sensor Landis Ni 1000

Abstract: DIN EN 60751 2750138 PT-1000 sensor Pt 1000 sensor PT-1000 sensor range FC18 PT 2000 temperature sensor NI-100 RTD DIN ibs STME
Text: IB ST (ZF) 24 PT 100 4/4 Analog Input Module with 4 Channels for the Connection of Resistance , terminals 33 and 36 (Us), 49 and 52 (). 3 IB ST (ZF) 24 PT 100 4/4 Typical Sensor Connections 4 , temperatures range from -200°C to +850°C for Pt 100 sensors and Pt 1000 sensors. The sensor characteristic , -328°F to +1562°F for Pt 100 sensors and Pt 1000 sensors. The sensor characteristic curves for Ni 100 , corresponding channel to be indicated. 5080C 5 IB ST (ZF) 24 PT 100 4/4 Celsius Scale Sensor


Original
PDF 5080C000 5080C temperature sensor Landis Ni 1000 DIN EN 60751 2750138 PT-1000 sensor Pt 1000 sensor PT-1000 sensor range FC18 PT 2000 temperature sensor NI-100 RTD DIN ibs STME
2006 - PT100 Emerson

Abstract: Pt 1000 sensor connection PT100 B DIN 43729 Siemens PT100 temperature sensor RTD SN29500 Wiring Diagram pt-100 siemens Siemens PT100 temperature sensor ex W5Re-W26Re Pt 100 RTD Siemens Pt 1000 sensor siemens
Text: following default configuration: Pt 100 sensor , measuring range 0°C . + 100 °C, 3-wire connection . The , ambient temperature range. The devices are supplied with the following default configuration: Pt 100 sensor , measuring range 0°C . + 100 °C, 3-wire connection . Features ­ ­ ­ ­ For resistance , Sensor (mV) 1 According to IEC 60584-1 Reference junction: Internal ( Pt 100 ) Reference junction , MCR-FL-HT-TS-I-EX Input Signals Designation Pt 100 10 K -60°C . +250°C 10 K -60°C . +150°C


Original
PDF
2004 - Resistance characteristic Ni1000

Abstract: ABB Pt100 3 wire accuracy of K type thermocouple EC certificate PTB ATEX 1144 X PT1000 temperature sensor PT100 IEC 751 pt100 atex Ni120 circuit diagram temperature measurement rtd PT-100 RTD 3 wire sensor rosemount
Text: FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent channels Input ­ Resistance , Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD , , Pt 100 (RTD), thermocouples, 1 or 2 independent channels General characteristics , EN 61000-4-3 10 V/m EN 61000-4-6 10 V Influences Influence of ambient temperature Pt 100 , ) Measuring error incl. characteristic deviation Pt 100 resistance measurement 0.500 0.4000


Original
PDF TF202/TF202-Ex Resistance characteristic Ni1000 ABB Pt100 3 wire accuracy of K type thermocouple EC certificate PTB ATEX 1144 X PT1000 temperature sensor PT100 IEC 751 pt100 atex Ni120 circuit diagram temperature measurement rtd PT-100 RTD 3 wire sensor rosemount
2000 - Not Available

Abstract: No abstract text available
Text: Platinum sensor Secondary reference Material P = Platin TCR = Pt 3850 ppm/K G = Pt , Order Information Platinum Sensor Secondary reference Material P = Platin TCR = Pt 3850 , 150 °C series Platinum sensor with wires For low temperatures Benefits & Characteristics , sensor available upon request W Illustration1) H H2 L 1) For actual size, see , :* 100 Ω at 0 °C 500 Ω at 0 °C 1000 Ω at 0 °C Characteristics curve:* 3850 ppm/K


Original
PDF
HTY7803T4P00

Abstract: TY7803Z0P00 HY7803T4000 HTY7803T1P00 HTY7813T1P00 PT 100 sensor installation TY7813Z0P00 PT-100, temp range 20 to 800 HTY7813T4P00 HTY7803
Text: 1-5 V Humidity output 4-20 mA Humidity output 0-10 V W/o temperature sensor Temperature Pt 100 Select a model No. from below HTY7803T1P00 Humidity (1-5 V) + temperature ( Pt 100 ) HTY7803T4P00 Humidity (4-20 mA) + temperature ( Pt 100 ) HTY7803T6P00 Humidity (0-10 V) + temperature ( Pt 100 ) HTY7813T1P00 Humidity (1-5 V) + temperature ( Pt 100 ) HTY7813T4P00 Humidity (4-20 mA) + temperature ( Pt 100 ) HTY7813T6P00 Humidity (0-10 V) + temperature ( Pt 100 ) TY7803Z0P00 Temperature ( Pt 100 ) TY7813Z0P00


Original
PDF AB-5961 HTY78X3/ TY78X3/ HY78X3 HTY78X3 Pt100 TY78X3 HTY7803 TY7813 HTY7803T4P00 TY7803Z0P00 HY7803T4000 HTY7803T1P00 HTY7813T1P00 PT 100 sensor installation TY7813Z0P00 PT-100, temp range 20 to 800 HTY7813T4P00 HTY7803
NTC 20K

Abstract: Pt 100 sensor connection Pt 1000 sensor connection PT-1000 RTD 3 wire pt 250 temperature sensor pt 100 sensor technical data PT-100 RTD PT-100 RTD 3 wire NI-100 RTD DIN Ni 120
Text: for Pt 200, Pt 500, Pt 1000, Ni 100 , Ni 120, Ni 1000, resistance measuring 3-wire connection , temperature device) input module allows the direct connection of Pt or Ni resistance sensors. The connection , . Other variations are available upon request: Pt 100 , Pt 200, Pt 500, Pt 1000, temperature range -200 °C , software. Description Item no. Pack. unit 1) 2AI Pt 100 /RTD 2AI Pt 1000/RTD 2AI Pt 100 /RTD S5 2) 2AI Pt 100 /free configurable 2AI Ni 100 /RTD 2AI Ni 1000 TK6180/ RTD 2AI Ni 1000 TK5000/ RT


Original
PDF D-32385 D-32423 NTC 20K Pt 100 sensor connection Pt 1000 sensor connection PT-1000 RTD 3 wire pt 250 temperature sensor pt 100 sensor technical data PT-100 RTD PT-100 RTD 3 wire NI-100 RTD DIN Ni 120
1999 - k 1058

Abstract: 81-110 thermistor L type thermocouple conversion table kty PT-100 KTY 81 210 MTKD-NICR/NI pg7sh thermocouple k 900 lg KTY 110 KTY 81 6
Text: FF Not permissible RTD-R0 is the sensor resistance at 0°C (32°F). This value is 100 for Pt , 0000hex) Desired Operating Mode Pt 100 DIN sensor and 0.1°C / LSB 0A00hex Pt 100 SAMA sensor and , with encapsulated sensors Sensor types that can be used (RTD) Pt 100 , Pt 1000, Ni., Cu., KTY , . 5 Sensor Connection , IB L2 BOX TEMP 2/2 M12 Sensor Connection 0 2 0 1 1 2 IN O U T IB L 2 B O X T E M P


Original
PDF SAC-4P-M12MS/1 SAC-4P-M12MS/3 SAC-4P-M12MS/5 SAC-4P-M12MR/1 SAC-4P-M12MR/3 SAC-4P-M12MR/5 k 1058 81-110 thermistor L type thermocouple conversion table kty PT-100 KTY 81 210 MTKD-NICR/NI pg7sh thermocouple k 900 lg KTY 110 KTY 81 6
2004 - pt 100 temperature sensor abb

Abstract: PT-100 ABB datasheet Pt 100 sensor connection PT-100 ABB TSHY sensytemp PT 100 sensor installation abb catalog voltage sensor pt sensytemp hy
Text: Information Catalog No. Temperature sensor TSHY (HY R-4E) for surface temperature measurement With Pt 100 , Pt 100 signal or 4.20 mA with installed transmitter High operational reliability ­ Components , (SensyTemp HY R) Installation design, suitable for the connection head of the HY R-4E temperature sensor , data Input Pt 100 (EN 60751), 3-wire circuit, fixed ranges Power supply Us = 10.5.30 V DC , value 0 °C: 0.15 % or 0.15 K nominal value < or > 0 °C: 0.2 % or 0.2 K Resistance element Pt 100


Original
PDF
buzh

Abstract: PT-100 RTD 3 wire sensor rosemount TR04-ECO 2.4 ghz FM TRANSMITTER CIRCUIT DIAGRAM TR04-Ex PTB 20017 Pt 100 sensor connection V11531-30 D-63755 PTB 99 ATEX
Text: lead resistance (max.) Sensor lead influence > 100 Sensor lead influence Pt 100 -measuring current , / characteristic / sensor break identification Pt 100 (acc. to IEC 751 / ITS 90), direct action characteristic , TR 04-Eco / TR 04-Ex Head mounted Temperature transmitters, analog, Pt 100 (RTD), fixed , . characteristic deviation Pt 100 /resistance measurement . Balancing error Spans > 100 °C < 0.1 % Spans < 100 °C < 0.15 K Linearity error < 0.10 % Pt 100 (IEC 751) ­200 °C.850 °C cf. ordering


Original
PDF 04-Eco 04-Ex 04-Eco/-Ex Z-187631 Z-20047 Z-20017 D-63755 buzh PT-100 RTD 3 wire sensor rosemount TR04-ECO 2.4 ghz FM TRANSMITTER CIRCUIT DIAGRAM TR04-Ex PTB 20017 Pt 100 sensor connection V11531-30 PTB 99 ATEX
2004 - contrans ts 11

Abstract: pt 100 temperature sensor RTD abb contrans ts 02 abb ts02 TS02-ex MEssumformer TS-02 th02 ptb 99 atex 2123 declaration Contrans ts02 PT100 IEC 751
Text: programmable, Pt 100 (RTD), thermocouples, electrical isolation Input ­ Resistance thermometer (2-, 3 , Parasoft 5 years warranty Head mounted Temperature Transmitter TS02/TS02-Ex programmable, Pt 100 , thermometer Pt 100 , Pt 200. Pt 1000; Ni 100 , Ni 500 min. span: 20 K (15 K) Internal reference junction Pt 100 , via software switchable (no jumper necessary) Resistance 0.500 / 0.5000 min. span , thermometer Pt 100 Resistance thermometer Pt 1000 -200.+ 850 °C -200.+ 850 °C (-328.+1562 °F


Original
PDF TS02/TS02-Ex contrans ts 11 pt 100 temperature sensor RTD abb contrans ts 02 abb ts02 TS02-ex MEssumformer TS-02 th02 ptb 99 atex 2123 declaration Contrans ts02 PT100 IEC 751
2001 - 81-110 thermistor

Abstract: Cu50 measurement Cu53 rtd PT-100 385 4wire temperature sensor Landis Ni 1000 CU53 kty PT-100 THERMISTOR kty Cu50 RTD KTY81-110
Text: : Resolution: 0.1°C Format: Format 1 (IB standard) Sensor type: 10 100 PT 100 (DIN , .] and PT 100 sensor ) Temperature measuring error for A = 0.25 mm2 (24 AWG) (3) Figure 16 (Measuring error valid for: copper cable = 57 m/mm2, TU = 25°C [77°F] and PT 100 sensor ) 2 ,5 K 2 ,0 , [16.404 ft.], A = 0.25 mm2 [24 AWG] and PT 100 sensor ) 26 5755B IB IL TEMP 2 RTD All diagrams , 1 .1 I1- 1.3 2 RTD sensor 1 1.2 1 I1+ Shield Shield connection (channel 1


Original
PDF 5755B KTY81 KTY84 16-bterminal 81-110 thermistor Cu50 measurement Cu53 rtd PT-100 385 4wire temperature sensor Landis Ni 1000 CU53 kty PT-100 THERMISTOR kty Cu50 RTD KTY81-110
2004 - SENSORS TEMPERATURE Pt-100-DIN 43760

Abstract: PTB 01 ATEX 2035 TS102 TS102-EX atex 2123 pt 100 temperature sensor RTD abb Pt 100 sensor connection PT-100 temperature ptb 99 atex 2123 pt 100 temperature sensor abb
Text: programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11-8.50 EN Connection diagram 11 + , programmable, Pt 100 (RTD), thermocouples, electrical isolation Input ­ Resistance thermometer (2-, 3 , TS102/TS102-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11-8.50 EN , Resistance Input filter 50/60 Hz Resistance thermometer Pt 100 , Pt 200. Pt 1000; Ni 100 , Ni 500 min. span: 20 K (15 K) Internal reference junction Pt 100 , via software switchable (no jumper necessary


Original
PDF TS102/TS102-Ex SENSORS TEMPERATURE Pt-100-DIN 43760 PTB 01 ATEX 2035 TS102 TS102-EX atex 2123 pt 100 temperature sensor RTD abb Pt 100 sensor connection PT-100 temperature ptb 99 atex 2123 pt 100 temperature sensor abb
Supplyframe Tracking Pixel