The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC4300A-2IMS8 Linear Technology LTC4300A-2 - Hot Swappable 2-Wire Bus Buffers; Package: MSOP; Pins: 8; Temperature Range: -40°C to 85°C
LTC4301CDD#TR Linear Technology LTC4301 - Supply Independent Hot Swappable 2-Wire Bus Buffer; Package: DFN; Pins: 8; Temperature Range: 0°C to 70°C
LTC4301CMS8#PBF Linear Technology LTC4301 - Supply Independent Hot Swappable 2-Wire Bus Buffer; Package: MSOP; Pins: 8; Temperature Range: 0°C to 70°C
LTC4302IMS-2#PBF Linear Technology LTC4302 - Addressable 2-Wire Bus Buffer; Package: MSOP; Pins: 10; Temperature Range: -40°C to 85°C
LTC4301IMS8#TR Linear Technology LTC4301 - Supply Independent Hot Swappable 2-Wire Bus Buffer; Package: MSOP; Pins: 8; Temperature Range: -40°C to 85°C
LTC4313CDD-2#TRPBF Linear Technology LTC4313 - 2-Wire Bus Buffers with High Noise Margin; Package: DFN; Pins: 8; Temperature Range: 0°C to 70°C

PT100 temperature transducer 3 wire Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
PT100 application note

Abstract: pt100 sensors PT100 IEC B PT100 temperature sensor class B application note pt100 pt100 thermometer RTD PT100 3wire PT100 temperature transducer 3 wire pt100 temperature sensor circuit connection MCR-SL-HT-PT100-I
Text: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4- wire technology ­ For installation , default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. 5 , : www.phoenixcontact.com/salesnetwork Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors , Transducer for PT100 Sensors MCR-SL-HT-PT100-I 2. Technical Data IN OUT 3 µC D 4


Original
PDF PT100 MCR-SL-HT-PT100-I MCR-FL-HT-PT100-I PT100 application note pt100 sensors PT100 IEC B PT100 temperature sensor class B application note pt100 pt100 thermometer RTD PT100 3wire PT100 temperature transducer 3 wire pt100 temperature sensor circuit connection MCR-SL-HT-PT100-I
2002 - MCR-SL-HT-PT100-I

Abstract: pt100 sensors PT100 SENSOR PT100 temperature transducer 3 wire PT100 2 wire temperature sensor -200 to 650 rtd pt100 sensor DIN43729
Text: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4- wire technology ­ For installation , configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Dimensional drawing for MCR-FL-HT-PT100-I 44 33 3 Programmable Loop-Powered Temperature Measuring Transducer for , Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 2. Technical Data IN OUT 3 4 5 6 D


Original
PDF PT100 MCR-SL-HT-PT100-I MCR-SL-HT-PT100-I pt100 sensors PT100 SENSOR PT100 temperature transducer 3 wire PT100 2 wire temperature sensor -200 to 650 rtd pt100 sensor DIN43729
2002 - RTD PT100 3wire

Abstract: MCR-SL-PT100-LP-I Pt100 3 wire pt100 temperature sensor circuit connection namur NE 43 pt100 4-20mA MCR-SL-PT100 rtd pt100 4-20ma connections pt100 temperature transducers Phoenix/pt100 4-20 ma
Text: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1 , 114,5 Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors ­ , PHOENIX CONTACT page 2 of 6 Programmable Loop-Powered Temperature Measuring Transducer for PT100 , temperature measuring transducer for PT100 resistance thermometer u solid [mm2] flexible AWG 24 - 15 Connection data 0.2 - 1.75 0.2 - 1.75 Description MCR temperature measuring transducer , for PT100


Original
PDF PT100 MCR-SL-PT100-LP-I RTD PT100 3wire MCR-SL-PT100-LP-I Pt100 3 wire pt100 temperature sensor circuit connection namur NE 43 pt100 4-20mA MCR-SL-PT100 rtd pt100 4-20ma connections pt100 temperature transducers Phoenix/pt100 4-20 ma
MCR-SL-PT100-LP-I

Abstract: PT100 application note RTD PT100 3wire PT100 SENSOR PT100 IEC 751 PT100 temperature transducer 3 wire pt100 thermometer pt100 sensors application note pt100 mcr pt100
Text: 6 2 3 4 Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors ­ , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1 , configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Headquar ters , /salesnetwork Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors ­ , Programmable loop-powered temperature measuring transducer for PT100 resistance thermometer u solid


Original
PDF PT100 MCR-SL-PT100-LP-I MCR-SL-PT100-LP-I PT100 application note RTD PT100 3wire PT100 SENSOR PT100 IEC 751 PT100 temperature transducer 3 wire pt100 thermometer pt100 sensors application note pt100 mcr pt100
NI500 temperature

Abstract: Ni100 sensor PT100 4 wire temperature sensor PT500 IEC 751 Resistance characteristic Pt1000 PT500 temperature sensor PT500 sensor PtRh10-Pt Ni1000 temperature sensor PT100 2 wire temperature sensor
Text: Temperature monitoring in a heat exchanger PT100 in 3-wire technology 4 3 R B Thermocouple type J , °C (32.212ºF) measuring range, 3-wire termination. 4 5 Temperature ­ Can be freely programmed , Loop-Powered Temperature Measuring Transducer - MCR-FL-HT-T-I 2. Technical Data IN OUT 3 µC , PHOENIX CONTACT page 5 of 7 4- wire Programmable Loop-Powered Temperature Measuring Transducer - , . Mounting screws 3 . Mounting springs 4. Temperature measuring transducer 5. Sensor insert with connection


Original
PDF PT100 NI500 temperature Ni100 sensor PT100 4 wire temperature sensor PT500 IEC 751 Resistance characteristic Pt1000 PT500 temperature sensor PT500 sensor PtRh10-Pt Ni1000 temperature sensor PT100 2 wire temperature sensor
2001 - PT100 IEC 751

Abstract: MCR-SL-PT100-I-DC-24 MCR-SL-PT100 phoenix DIP switch settings MCR-SL-PT100 DC 24 MCR-SL-PT100-U-DC-24 pt 100 sensor pt100 temperature transducers PT100 type B iec 60751 PT-100 sensor
Text: Temperature Measuring Transducer for PT100 MCR-SL-PT100-.-DC-24 1. Description MCR-SL-PT100 , increase the process safety, the modules are equipped with 3 -way isolation. 2-, 3 -, and 4- wire PT100 , Temperature Measuring Transducer for PT100 ­ MCR-SL-PT100-.-DC-24 2. Technical Data OUT 1 2 D , MCR-SL-PT100-.-DC-24 Temperature measuring transducer for PT100 8 M3 rigid Connection data [mm2 , .) * Pcs. Pkt. Description Type Order No. Temperature measuring transducer , for the PT100


Original
PDF PT100 MCR-SL-PT100-. -DC-24 MCR-SL-PT100 PT100 rigid751/EN PT100 IEC 751 MCR-SL-PT100-I-DC-24 phoenix DIP switch settings MCR-SL-PT100 DC 24 MCR-SL-PT100-U-DC-24 pt 100 sensor pt100 temperature transducers PT100 type B iec 60751 PT-100 sensor
ni500 DIN 43760

Abstract: PT500 IEC 751 Resistance characteristic Ni1000 Resistance characteristic Pt1000 W5Re-W26Re ni1000 DIN 43760 PT100 IEC 751 accuracy Ni100 sensor pt100 4-20 ma RTD PT1000 conversion
Text: CONTACT page 5 of 6 2 3 4 Programmable Loop-Powered Temperature Measuring Transducer ­ , Programmable Loop-Powered Temperature Measuring Transducer MCR-FL-T-LP-I 1. Brief Description ­ , temperature range. The devices are supplied with the following default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Headquarters: © Phoenix Contact GmbH & Co. KG · , Connection type: 2, 3 or 4- wire termination With 2- wire termination, the cable resistance can be compensated


Original
PDF
pt100/RTD PT100

Abstract: PT100 temperature sensor data sheet pt100 resistance thermometer pt100 thermometer pt100/RTD PT100 2 wire temperature sensor Resistance thermometers RTD PT100 temperature transducer 3 wire PT100 temperature sensor PT100 4 wire temperature sensor
Text: thermometer: - Pt100 or resistance < 400 mA Resistance of wires connecting the resistance thermometer with the transducer < 10 W / wire Transducer preheating time 15 min Rated operating , function of cold junction temperature changes. The P17 transducer is supplied from the current loop, and , TRANSDUCER SUPPLIED FROM A CURRENT LOOP Range of analog output 4.20 mA Output resolution 0.005 mA Additional error from ambient temperature changes ± (0.25 % range /10K) P17


Original
PDF Pt100 P17-05 pt100/RTD PT100 PT100 temperature sensor data sheet pt100 resistance thermometer pt100 thermometer pt100/RTD PT100 2 wire temperature sensor Resistance thermometers RTD PT100 temperature transducer 3 wire PT100 temperature sensor PT100 4 wire temperature sensor
temperature transmitter pt100 4-20ma atex

Abstract: rtd sensor pt100 PT100 SENSOR Resistance characteristic Ni1000 Resistance characteristic Pt1000 PT500 IEC 751 PT1000 thermocouple Thermocouple type PT100 thermocouple cable PT1000 application note
Text: °C (32.212ºF) measuring range, 3-wire termination. 4 5 Temperature ­ Can be freely programmed , · PT100 , PT500, PT1000 and Ni100, Ni500, Ni1000 resistance thermometers, in 2, 3 or 4- wire , 3 of 7 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer - , Intrinsically Safe Loop-Powered Temperature Measuring Transducer - MCR-FL-HT-T-I-Ex 5. Connections 2- Wire , 729 Form B 1. Cover 2. Mounting screws 3 . Mounting springs 4. Temperature measuring transducer 5


Original
PDF
pt100/RTD PT100

Abstract: PT100 temperature sensor data sheet signal conditioning circuit for pt100 Resistance thermometers RTD pt100/RTD PT100 thermocouple pt100 datasheet Pt100 3 wire lumel pt100 resistance thermometer
Text: consumption 1s < 0.7 VA Current flowing through the resistance thermometer: - Pt100 or resistance < 400 mA Resistance of wires connecting the resistance thermometer with the transducer < 10 W / wire Transducer preheating time 15 min Additional error from ambient temperature changes ± , -05.0 comp. auto means a transducer version supplied from a current loop, 05 - Input signal: Pt100 RTD , TRANSDUCER SUPPLIED FROM A CURRENT LOOP P15 TYPE Range of analog output 4.20 mA


Original
PDF Pt100 pt100/RTD PT100 PT100 temperature sensor data sheet signal conditioning circuit for pt100 Resistance thermometers RTD pt100/RTD PT100 thermocouple pt100 datasheet Pt100 3 wire lumel pt100 resistance thermometer
2002 - hart protocol

Abstract: Resistance characteristic Pt1000 Pt1000 RTD Sensor Thermocouple Type K linearization Pt100 transmitter 4.20 mA ni1000 DIN 43760 Resistance characteristic Ni1000 Resistance thermometer mw PT500 SENSOR PT500 thermocouple
Text: default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. 4 , Loop-Powered Temperature Measuring Transducer With HART Protocol - MCR-FL-HT-TS-I-Ex 3 . Technical Data , Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HARTProtocol , Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol - , +150°C (-76 to +302°F) 10 K 10 K 10 K · · · · Resistance sensor Connection type: 2, 3 or 4- wire


Original
PDF
PT500 temperature sensor

Abstract: Pt1000 transmitter 4.20 mA Phoenix Ni1000 2-wire W5Re-W26Re IEC 751 PT500 SENSOR PT500 IEC 751 MoRe5-MoRe41 INTRINSICALLY SAFE PLC PT100 IEC B
Text: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer MCR-FL-T-LP-I-Ex 1 , temperature range. The devices are supplied with the following default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Headquarters: © Phoenix Contact GmbH & Co. KG · , Loop-Powered Temperature Measuring Transducer - MCR-FL-T-LP-I-Ex 1.1. Input Signals Designation , Resistance sensor Connection type: 2, 3 or 4- wire termination With 2- wire termination, the cable


Original
PDF eebt02 PT500 temperature sensor Pt1000 transmitter 4.20 mA Phoenix Ni1000 2-wire W5Re-W26Re IEC 751 PT500 SENSOR PT500 IEC 751 MoRe5-MoRe41 INTRINSICALLY SAFE PLC PT100 IEC B
2002 - 3 wire pt100 sensor

Abstract: temperature sensor Landis Ni 1000 phoenix contact MCR R I 4v KTY 81-110 philips pt100 sensor interface with microcontroller PT100 connected diagram PT100 3 wire connected diagram cable NICR-NI thermocouple L type thermocouple conversion table signal converter pt100
Text: standard configuration - MCR-T-UI(-E)/NC ( PT100 DIN IEC 751 3-wire from -200.850°C (-328°F. 1562 , Temperature Measuring Transducer ­ MCR-T-UI(-E). 2. Technical Data OUT + - 1 2 3 + - , PHOENIX CONTACT page 3 of 7 5 MCR Temperature Measuring Transducer ­ MCR-T-UI(-E). 3 . Method , MCR-T-UI-E / PT100 / D 3 / -200.0 / +850.0 / 1 / 3 / 1 (Configuration for 3-wire , Temperature monitoring with a PT100 element in 2- wire technology when using the transistor switching output


Original
PDF PT100: 3 wire pt100 sensor temperature sensor Landis Ni 1000 phoenix contact MCR R I 4v KTY 81-110 philips pt100 sensor interface with microcontroller PT100 connected diagram PT100 3 wire connected diagram cable NICR-NI thermocouple L type thermocouple conversion table signal converter pt100
3 wire pt100 sensor

Abstract: PT100 3 wire connected diagram Ni1000 CONVERSION TABLE PT100 resistor Cu50 measurement Ni1000 temperature sensor ni1000 KTY 81-110 philips MCR-TTL-RS232 L type thermocouple conversion table
Text: monitoring function. 1.1. Versions · With standard configuration - MCR-T-UI(-E)/NC ( PT100 DIN IEC 751 3-wire , 5 MCR Temperature Measuring Transducer ­ MCR-T-UI(-E). 3 . Method of Operation The analog , MCR-T-UI-E / PT100 / D 3 / -200.0 / +850.0 / 1 / 3 / 1 (Configuration for 3-wire , Temperature monitoring with a PT100 element in 2- wire technology when using the transistor switching output , Transducer 1. Description A universal temperature measuring transducer for resistance thermometers and


Original
PDF MCR-TTL-RS232-E PT100: 3 wire pt100 sensor PT100 3 wire connected diagram Ni1000 CONVERSION TABLE PT100 resistor Cu50 measurement Ni1000 temperature sensor ni1000 KTY 81-110 philips MCR-TTL-RS232 L type thermocouple conversion table
2012 - ultrasonic flow meter

Abstract: ultrasonic flowmeter circuit PLC based WATER LEVEL CONTROL
Text: sensor pair Accuracy – Temperature For T: <1°C (33.8 °F) Sensor Type: PT100 . 4- wire Repeatability , €¢ Industrial grade temperature sensors and ultrasonic sensors for improved robustness • Paired PT100 RTD , temperature measurement. MEASURE TODAY. ENSURE TOMORROW. 3 Versatile Interfaces TP10 provides , to the temperature inside of the pipe. • Flow Transducer • Surface Temperature Sensor , PC software use. ID A B C Temperature Sensor Wire Length None 3m (10ft) 10m (30ft) ID


Original
PDF
2013 - kd 2060 transistor

Abstract: saia factory 124
Text: External transducer supply (option) Supply Resistance thermometer in a 3-wire system , measuring inputs Supply Resistance Resistance thermometer in a thermometer in a 3-wire system 2- wire , (option) Resistance thermometer in a 3-wire system Resistance thermometer in a 2- wire system , ) Connection of two wire transducer (0.10 V) Connection of two wire transducer (4.20 mA) Supply , 1 2 3 4 5 N24T/N25T 0.20 mA 4.20 mA 0.60 mV 0.10 V ± 60 mV ± 10 V Pt100


Original
PDF rs-485 kd 2060 transistor saia factory 124
rtd pt100 sensor JIS C1604

Abstract: pt100/RTD PT100 signal conditioning circuit for pt100 MAX4236 pt100 pt100 TRANSFER FUNCTION pt100 jis current source pt100 PT100 table pt100 sensor interface WITH ADC maxim pt100 interface
Text: Feedback Compensates PT100 Transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature transducer , and explains a simple analog approach , the most reliable standard available for temperature measurement. The PT100 RTD is described by the , 3 . Resistance/ Temperature Table* for 385 Platinum, 100.0 at 0°C °C 0 1 2 3 4 5 , and temperature . Page 3 of 11 Figure 1. This two-wire connection affects measurement accuracy


Original
PDF PT100 PT100 com/an3450 MAX197: MAX4236: MAX4237: AN3450, APP3450, Appnote3450, rtd pt100 sensor JIS C1604 pt100/RTD PT100 signal conditioning circuit for pt100 MAX4236 pt100 pt100 TRANSFER FUNCTION pt100 jis current source pt100 PT100 table pt100 sensor interface WITH ADC maxim pt100 interface
maxim pt100 interface

Abstract: DIN 17006 pt100 TRANSFER FUNCTION pt100 sensor interface WITH ADC pt100 maxim signal conditioning circuit for pt100 MAX4236 pt100 pt100 sensor interface WITH ADC for max197 PT100 IEC 751 Resolution current source pt100
Text: feedback compensates PT100 transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature transducer , and explains a simple analog approach , reliable standard available for temperature measurement. The PT100 RTD is described by the following , . Resistance/ temperature table* for 385 platinum, 100.0 at 0°C °C 0 1 2 3 4 5 6 7 8 9 -100 60.26 , 0 1 2 3 4 5 7 8 9 200 175.84 *RTD PT100 table showing the relation


Original
PDF PT100 MAX4236 MAX4237 com/an3450 AN3450, APP3450, Appnote3450, maxim pt100 interface DIN 17006 pt100 TRANSFER FUNCTION pt100 sensor interface WITH ADC pt100 maxim signal conditioning circuit for pt100 MAX4236 pt100 pt100 sensor interface WITH ADC for max197 PT100 IEC 751 Resolution current source pt100
Carlo Gavazzi Group pt-100 controller

Abstract: pt100 carlo gavazzi PT100 temperature PT-100 carlo gavazzi Carlo Gavazzi Group pt-100 PT-100 G3210 G38900030 G32101113 pt100 dissipation
Text: Temperature drift Cable length Response time 3-wire Pt-100 G 3210 1111: -50 to +40°C G 3210 1112: +30 , Transmitter for Analog Pt-100 Temperature Signal Types G 3210 1111, G 3210 1112, G 3210 1113 · · · · · · · · · Product Description AnaLink transmitter for connection of external 3-wire Pt100 temperature transducer . The module measures the temperature and transmits the value to the , /or read from a PC. Du line ® Fieldbus Installationbus AnaLink transmitter for 3-wire Pt-100


Original
PDF Pt-100 Pt100 Pt-100 Carlo Gavazzi Group pt-100 controller pt100 carlo gavazzi PT100 temperature PT-100 carlo gavazzi Carlo Gavazzi Group pt-100 G3210 G38900030 G32101113 pt100 dissipation
1999 - Not Available

Abstract: No abstract text available
Text: Description AnaLink transmitter for connection of external 3-wire Pt100 temperature transducer . The module measures the temperature and transmits the value to the controller G 3890 0030, in which the , transmitter for 3-wire Pt-100 input Built-in cable-compensation Built-in signal linearization Temperature , Inaccuracy Temperature drift Cable length Response time 3-wire Pt-100 G 3210 1111: -50 to +40°C G , Dupline® Field- and Installationbus Transmitter for Analog Pt-100 Temperature Signal Types G


Original
PDF Pt-100 Pt100
eliwell

Abstract: ELIWELL EWHS 28 RH PROBE ELIWELL EWHS 31 RH PROBE ewpc 902 ewpc 902 dp Humidity Sensor ewpc902 74x32 PT100 table ptc 100 rtd
Text: panel · Output: one (1) SPDT relay 8( 3 )A 250V AC · Auxiliary output: 12 Vdc/60 mA (for transducer , gnd 5 Pt100 / Ni100 2 wires blue 3 8 9 10 Pt100 / Ni100 3 wires PTC 1 8 9 , Output: one (1) SPDT relay 8( 3 )A 250V AC. Auxiliary output: 12 Vdc/60 mA (for transducer power supply , different versions of this controller are available: EWPC 902/T for Temperature , EWPC 902/R for Relative , protection of the rear terminal block · Connections: screw terminal block (2.5 mm2; one wire each terminal


Original
PDF 902/T 902/R 902/P 74x32 913x1 9FT40119 eliwell ELIWELL EWHS 28 RH PROBE ELIWELL EWHS 31 RH PROBE ewpc 902 ewpc 902 dp Humidity Sensor ewpc902 PT100 table ptc 100 rtd
Not Available

Abstract: No abstract text available
Text: . Alternatively, Ni100/ Pt100 resistors in 2, 3 or 4-wire-technology can be operated at the measuring amplifier , DTM: I Connection mode (2, 3 and 4- wire technology) I Measuring range I Input circuit , intrinsically safe acc. to EN 60079 PT100 (IEC 751), NI100 (DIN 43760), 2, 3 - und 4Leiter-Technik, nach Gost , µV 2- wire < 100mò after line compensation 3-wire < 100mò with asymmetrical wiring 4- wire < 50mà , Temperature measuring amplifier 2-channel IMB-TI-RTD-231Ex-HCi/24VDC The 2-channel temperature


Original
PDF IMB-TI-RTD-231Ex-HCi/24VDC IMB-TI-RTD-231Ex-HCi/24VDC Ni100/Pt100 D-45472 2013-07-13T20
sensor PT100

Abstract: SEM104 PT100 in head PT100 Platinum Resistance Thermometer probe Platinum Resistance Temperature DM500X DM400X FRO 021 DM420X iron constantan temperature sensor
Text: Pt100 INPUT X T/C INPUT K T OR J X TWO WIRE 4-20 mA OUTPUT X LOW COST TEMPERATURE , SEM104 CONNECTIONS + T/C ­ 24V Pt100 2 or 3 wire LOAD STANDARD RANGES °C Range °C SEM104 , ASSOCIATED PRODUCTS SEM205P `Smart' Low cost Pt-100 in head Temperature transmitter The SEM205P accepts Pt-100 platinum resistance temperature sensors and converts the output to the 4-20mA industry , transmitter The SEM210 accepts any commonly used temperature sensor, Slidewire transducer or millivolt


Original
PDF SEM205P Pt-100 SEM205P 4-20mA SEM205XP FM3610) SEM210 sensor PT100 SEM104 PT100 in head PT100 Platinum Resistance Thermometer probe Platinum Resistance Temperature DM500X DM400X FRO 021 DM420X iron constantan temperature sensor
jumo 90.295

Abstract: tya-332 PT100 90.295 90.165-F41 90.295 jumo tya-332 PT1000 table Thermocouple type PT100 jumo PT1000 JUMO PT100 resistor
Text: with falling characteristic Permitted ambient temperature range 0-55°C Input Pt100 , Pt1000 in 3-wire circuit Permitted storage temperature range -40 to +70°C Climatic conditions rel , input filter. Input Output limitation Lead compensation not required for 3-wire circuit. When , 70.0702 (2) ( 3 ) (4) ­ . ­ . ­ . Accessories Mineral-insulated Pt100 resistance thermometer , /10-001-101-23/000 6.99/00366723 Control range -200 to +850°C Transducer Pt100 * Sales No. 00360136


Original
PDF Pt1000 RS485 Pt100* jumo 90.295 tya-332 PT100 90.295 90.165-F41 90.295 jumo tya-332 PT1000 table Thermocouple type PT100 jumo PT1000 JUMO PT100 resistor
PT100 temperature sensor JUMO

Abstract: PT1000 table jumo itron signal conditioning circuit for pt100 4-20 mA PT100 JUMO PROCESS CONTROL TIMER PT1000 temperature sensor PT1000 temperature sensor JUMO PI CONTROLLER circuit jumo ITRON 702043
Text: temperature error 50 ppm/°C 50 ppm/°C 50 ppm/°C 20 max. per lead for 2- and 3-wire circuit 250µA Not , 7 Supply see label 1 8 9 N AC AC + Pt100 /1000 ( 3-wire , + Pt100 /1000 KTY11-6 (2- wire ) AC/DC ­ Pt100 /1000 ( 3-wire ) floating contact ­ , (alternative to output 2) ­ Logic input Pt100 /1000 ( 3-wire ) 110-240V Thermocouple L1 , setpoint, e. g. cooling ( 3 ) Inputs 001 = Pt100 3-wire 040 = Fe-Con J 045


Original
PDF 1-800-554-JUMO Pt100 Pt1000 KTY11-6 0--20mA Pt10Rh-Pt 4--20mA PT100 temperature sensor JUMO PT1000 table jumo itron signal conditioning circuit for pt100 4-20 mA PT100 JUMO PROCESS CONTROL TIMER PT1000 temperature sensor PT1000 temperature sensor JUMO PI CONTROLLER circuit jumo ITRON 702043
Supplyframe Tracking Pixel