The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT5400BMPMS8E-3#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -55°C to 125°C
LT5400BHMS8E-7#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -40°C to 125°C
LT5400BIMS8E-7#PBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -40°C to 85°C
LT5400ACMS8E-1#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: 0°C to 70°C
LT5400AIMS8E-1#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -40°C to 85°C
LT5400BCMS8E-3#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: 0°C to 70°C

PT100 resistor Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
PT100 standard IEC 60751 accuracy

Abstract:
Text: 4.20 mA). The MTW module supplies a constant current to the PT100 resistor across, which develops a , data Supply voltage range Supply current Cable resistance (without PT100 ) Output signals , Murrelektronik temperature converter module works in conjunction with a temperature sensor PT100 (IEC 751/EN , between the MTW and the PT100 sensor to be covered, i.e. <5 m. For longer distances, 3-wire technology


Original
PDF PT100) 6644333iable PT100 PT100 standard IEC 60751 accuracy PT100 IEC 751 PT100 resistor pt100 temperature sensor circuit diagram temperature sensor pt100 sensor PT100 mtw 12 pt100 circuit diagram PT100 bridge PT-100 temperature sensor
Not Available

Abstract:
Text: / Pt100 resistor in 2, 3 or 4-wire technology I I I Measuring range, lower limit -100…- 1 °C , thermo detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , . Alternatively, Ni100/ Pt100 in 2, 3 or 4-wiretechnology can be operated at the measuring amplifier's input circuit. The Ni100/ Pt100 input can either be used as external cold junction compensation for the , Application area acc. to ATEX: II (1) G; II (1) D Installation in zone 2 Input for Pt100 / Ni100 resistors


Original
PDF IM34-12EX-RI IM34-12EX-RI Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472
Not Available

Abstract:
Text: I Type of probe Connection of the Ni100/ Pt100 resistor in 2, 3 or 4-wire technology I I , thermo detectors (RTD) Ni100/ Pt100 , thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , . Resistance thermo detectors Ni100/ Pt100 in 2, 3 or 4-wire-technology can be operated alternatively at the input circuit of the measuring amplifier. The Ni100/ Pt100 input can either be used as external cold , zone 2 Input for Pt100 / Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4


Original
PDF IM34-11EX-I IM34-11EX-I Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472
SONDA PT100

Abstract:
Text: obligatoirement être du type Pt100 . Le module permet de mesurer des températures comprises entre -20°C et , supplied with the modules. These sensors must be Pt100 sensors. The module allows temperatures between , zijn niet meegeleverd met de modules. Deze sensoren moeten beslist van het type Pt100 zijn. De module , sondas de temperatura. Estas sondas no se suministran junto con los módulos. Deben ser del tipo Pt100 , juntamente com os módulos. Estas sondas têm de ser do tipo Pt100 . O módulo permite medir temperaturas


Original
PDF N292518/00 CEI61010 Pt100 37827A SONDA PT100 sonde pt100 Pt100-sensor modulo PT100 PT100 temperature sensor of temperatur N2925 PT100 resistor PT100 SENSOR sonde de temperature
PT100 resistor temperature

Abstract:
Text: · 6 inputs for PT100 resistors · 6 current outputs 4-20mA according to DIN EN 60751 & IEC 751 · Can , in connection with the SELCO M3000 Analog Alarm Annunciator. The PT100 resistors are connected at the inputs illustrated in fig. 1. The resistance of PT100 resistors depends on the temperature. The , for 0-160°C PT100 resistors, 0°C corresponds to 4mA, 80°C correspond to 12mA and 160°C correspond to , reference resistor R should be used with M3000-20 Analog Alarm Annunciator, but not with the newer version


Original
PDF PT100 4-20mA M3000 M1500 M3000-20 PT100 resistor temperature annunciator IEC 751 PT100 resistor selco
2007 - PT100 Thermocouple Amplifier

Abstract:
Text: Note: The PT100 is a platinum resistor with a resistance of 100 Ohms at 0 degrees Centigrade , +5ISO + LED HEARTBEAT R1 RTD PT100 INA326 Vpt +5ISO Vref R1 LDO REGULATOR , PT100 RTD is connected to a separate instrumentation amplifier (U2), set to the same gain as the instrumentation amplifier connected to the thermocouple (U1). The PT100 has a resistance of 100 at 0°C. Its , therefore a function of temperature and the current through the RTD. The value of resistor R1 (20 k) is


Original
PDF SLOA123 INA326 PT100 Thermocouple Amplifier DCR10505 Amplifier k thermocouple texas PT100 Platinum Resistance Temperature Detector RTD CIRCUITS analog instruments pt100/RTD PT100 PT100 resistor PT100 application note thermocouple to digital interface SLOA123
2007 - pt100 interface to pic

Abstract:
Text: PT100 RTD Evaluation Board User's Guide © 2007 Microchip Technology Inc. DS51607B Note , . DS51607B-page ii © 2007 Microchip Technology Inc. PT100 RTD EVALUATION BOARD USER'S GUIDE Table of , . 5 1.2 What is the PT100 RTD Evaluation Board? . 5 1.3 What the PT100 RTD Evaluation Board Kit Includes . 5 , . 22 © 2007 Microchip Technology Inc. DS51607B-page iii PT100 RTD Evaluation Board User


Original
PDF PT100 DS51607B DS51607B-page pt100 interface to pic pt100 amplifier schematic pt100 sensor interface with microcontroller pt100 pic pt100 adc microchip USB PIC18F2550 assembly .asm pt100 rtd spi connection between Pt100 to opamp PT100 RTD USB to SPI PIC18F2550 assembly .asm
2008 - PT100 temperature sensor data sheet

Abstract:
Text: Cable Sensor, Pt100 /Pt1000 Sensors with 4-wire silicone cable for pockets or tubes 4-wire air , , Building Block Temperature Measuring System Description A platinum resistor is built into the , measuring the value of the resistance gives an analogue expression for the actual temperature. The Pt100 , the nominal working range. The Pt100 sensor fits as an insert in sensor tubes with an internal , /EN/IEC 60751) Pt100 , 1/1 DIN B, single, specified accuracy -50.400°C Pt100 , 1/3 DIN B, single


Original
PDF Pt100/Pt1000 Pt100 UK/2008-06-02 PT100 temperature sensor data sheet PT100 temperature sensor 811A tube PT100 temperature sensor 3 wires pt1000 class B, DIN EN 60751 PT1000 Sensor Data PT1000 temperature sensor
2XPT100

Abstract:
Text: Designation Pt100 EN 60 751 Accuracy1 -200 to +850°C 0.1% KTY11-6 PTC -50 to +150 °C , % W3Re-W25Re D Cold junction Pt100 internal Cold junction accuracy ± 1°C Sampling interval 90 , =001 (3-wire circuit) and compensated with a resistor . Compensation condition: Rlead = Rcomp Resistance thermometer in 3-wire circuit Resistance thermometer 2 x Pt100 in 2-wire circuit for , 90.2006 Probe type Temperature range 90.271-F01 2 x Pt100 -170 to +700°C Nom. length mm


Original
PDF 1-800-554-JUMO KTY11-6 TTL/RS232C 2XPT100 Pt30Rh-Pt6Rh 701140 2XPT100 JUMO 90D239-F03 Pt10Rh-Pt Thermocouple type PT100 jumo pt100 temperature probe circuit diagram 90-D-239 pt10rh-pt type s
gefran pt100

Abstract:
Text: signal: Humidity: analog Temperature: Pt100 1/3DIN · Thin film capacitive humidity sensor · Wire mesh , ) Sensor response time Pt100 1/3 DIN (90% of scale for a step change from 11% to 75 %RH) < 10 sec / Output Signal T211.A 4.20mA Pt100 1/3 DIN (3 wires) T211.B 0.10V Pt100 1/3 DIN (3 , % Load resistor : R Operating range Housing Storage Housing Dimension Material / Output 4


Original
PDF Pt100 Pt100 gefran pt100 PT100 resistor gefran Pt100 transmitter 4.20 mA rtd pt100 sensor thin film PT100 2 wire temperature sensor temperature PT100 pt100 0-10V gefran 40 PT100 temperature sensor 3 wires
gefran pt100

Abstract:
Text: : Humidity: analog Temperature: Pt100 1/3DIN · Thin film capacitive humidity sensor TECHNICAL DATA , non-linearity included ± 3 %RH (10.90 %RH) ± 5 %RH (<10, >90 %RH) Pt100 1/3 DIN Sensor response , signal T212.A 4.20mA Pt100 1/3 DIN (3 wires) T212.B 0.10V Pt100 1/3 DIN (3 wires , resistor : R Operating Range Housing Storage Housing Dimension Storage IP Protection Electrical


Original
PDF Pt100 Pt100 gefran pt100 rtd pt100 sensor thin film Pt100 transmitter 4.20 mA PT100 resistor gefran electronic hygrometer pt100 0-10V T212 PT100 resistor temperature measuring resistor pt100
2002 - Arrayed Waveguide Grating

Abstract:
Text: . Signals are output in 0-5 V levels. 4 GND 5 R-SET Temperature set resistor terminal 1 6 R-SET Temperature set resistor terminal 2 7 +5 Volts Supply input RTD L2 PT100 Temp Resistor Note 1. Values quoted are for all polarizations and all operating temperatures in a clear , °C) <1 nA 9 RTD L1 PT100 Temp Resistor 10 RTD H2 PT100 Temp Resistor Dark current (­5 V; 85°C) < 120 Forward current (0.5 V) > 10 µA 11 RTD H1 PT100 Temp Resistor


Original
PDF V23846-Pwxyz( D-13623, Arrayed Waveguide Grating PT100 resistor GR-1221-CORE Power Line Communications PT100 RTD signal conditioning pt100 temp rtd pt100 datasheet
1996 - defibrillator circuits

Abstract:
Text: controller, isolation protects the circuit if the resistance-temperature detector (RTD), a PT100 , is , Isolation Amplifiers PT100 Transducer Power Supply Heat Source Signal Valve Output 20mA , 11 3 12 2N2222A Q1 15 RCV420 14 13 2 7 C1 0.01µF PT100 12 XTR101 , Controller, the Isolated Input Channel Runs from the PT100 Transducer to the XTR101 Two-Wire Transmitter , XTR101, the external 2N2222A conducts all but 4mA of the transmitter current. The 750, 1/2W resistor


Original
PDF
2014 - PT2000 temperature sensor

Abstract:
Text: measuring system that uses only three active devices. The system processes the output of a Pt100 RTD and , U1C 1/4 VDD VR INPUT REF OUT LINE +3.3V (C-GRADE) GND J2 RTD ( Pt100 ) 1 +3.3V REGCAP A Figure 1. Resistance Deviation to Digital Conversion with Isolation Using Pt100 , amplifies this voltage change by 19.6, producing an output span of 2.3 V. Resistor R2 added in parallel with Resistor R1 shifts the output range so that the U1A op amp output is 0.1 V to 2.4 V, which


Original
PDF CN-0337 AD8608 AD7091R 12-Bit ADuM5401 com/CN0337. 12-Bit, CN11653-0-3/14 PT2000 temperature sensor PT2000 pt100 dissipation pt100 rtd spi
2001 - PT100 2 wire temperature sensor

Abstract:
Text: MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into binary alarm switching , 00 · www.phoenixcontact.com MCR-SL-PT100-SP Thermostat for the PT100 2. Technical Data PT100 OUT SETPOINT 1 5 14 12 11 6 11 U 2 12 DC +24VDC 3 GND 4 114.5 IN 7 11 DC 8 14 99 MCR-SL-PT100-SP Thermostat for the PT100 8 M3


Original
PDF MCR-SL-PT100-SP PT-100 MCR-SL-PT-100-SP PT-100 PT100 PT100 2 wire temperature sensor PT100 IEC 751 pt100 on linearity PT100 resistor pt100 temperature sensor circuit connection PT100 temperature sensor class B
rtd pt100 sensor JIS C1604

Abstract:
Text: Feedback Compensates PT100 Transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature transducer, and explains a simple analog approach , the most reliable standard available for temperature measurement. The PT100 RTD is described by the , 2 4 5 7 8 9 200 175.84 *RTD PT100 table showing the relation between resistance , effect of voltage drops in the two connecting wires. You can connect a PT100 RTD to the measuring


Original
PDF PT100 PT100 com/an3450 MAX197: MAX4236: MAX4237: AN3450, APP3450, Appnote3450, rtd pt100 sensor JIS C1604 pt100/RTD PT100 signal conditioning circuit for pt100 MAX4236 pt100 pt100 TRANSFER FUNCTION pt100 jis current source pt100 PT100 table pt100 sensor interface WITH ADC maxim pt100 interface
1999 - elcon SERIES 1000

Abstract:
Text: B ߜ Input Output Isolation ߜ For J, K, T, E, R, S, B Thermocouples, mV, and Pt100 and Ni100 , across 250 Ω shunt resistor .) All models feature zero and span jumpers (26 steps each). Reference , . Thermocouple inputs linear to mV input, not temperature. (Output is linear to temperature for PT100 RTD) Load , Programmable Code Low High J,K,T,E, Pt100 J,K,T,E, Pt100 J,K,T,E, Pt100 J,K,T,E, Pt100 , Ni100 J,K,T,E, Pt100 , Ni100 J,K,T,E, Pt100 , Ni100 J,K,T,E, Pt100 , Ni100 J,K,T,E, Pt100 , Ni100 J,K,T,E, Pt100 , Ni100


Original
PDF Pt100 Ni100 SIB-BP-1116-TB-R KTSS-316G-12 TQSS-316G-12 12AWG elcon SERIES 1000
PT100 IEC 751

Abstract:
Text: MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into binary alarm switching , www.phoenixcontact.com MCR-SL-PT100-SP Thermostat for the PT100 2. Technical Data PT100 OUT SETPOINT , DC 8 14 99 MCR-SL-PT100-SP Thermostat for the PT100 8 M3 rigid [mm2] Connection , in.) * Description Type Order No. Pcs. Pkt. Thermostat, for the PT100 sensor


Original
PDF MCR-SL-PT100-SP PT-100 MCR-SL-PT-100-SP PT-100 PT100 PT100 IEC 751 PT100 resistor PT100 4 wire temperature sensor active length PT100 table PT100 class A pt100 out PT100 2 wire temperature sensor sensor thermostat
2000 - ecg simulator circuit

Abstract:
Text: controller, isolation protects the circuit if the resistance-temperature detector (RTD), a PT100 , is , Isolation Amplifiers PT100 Transducer Power Supply Heat Source Signal Valve Output 20mA , 11 3 12 2N2222A Q1 15 RCV420 14 13 2 7 C1 0.01µF PT100 12 XTR101 , Controller, the Isolated Input Channel Runs from the PT100 Transducer to the XTR101 Two-Wire Transmitter , XTR101, the external 2N2222A conducts all but 4mA of the transmitter current. The 750, 1/2W resistor


Original
PDF
Pt100 transmitter

Abstract:
Text: INDEX SECTION SEM1503P & SEM1504P DIN Rail Mounted Pt100 Transmitter Status Instruments , temperature transmitters designed to accept a standard platinum resistance sensor (SEM1503P; Pt100 2 or 3 wire, SEM1504P; Pt100 2 or 4 wire) to BS EN60751;1996, DIN 43760 and convert the temperature to a (4 , ends of the scale. 2.0 SPECIFICATION @20ºC 3.1 MECHANICAL Type Pt100 2 or 3 wire (SEM1503P) Pt100 2 or 4 wire (SEM1504P) BS EN60751; 1996, DIN 43760 Accuracy Accuracy ± 0.15 ºC ± % reading


Original
PDF SEM1503P SEM1504P Pt100 SEM1503P; SEM1504P; EN60751 Pt100 transmitter PT100 resistor SEM1503P pt100 datasheet 3 wire pt100 sensor transmitter pt100 PT100 2 wire temperature sensor PT100 table PT100 in head
PLATINUM RESISTOR

Abstract:
Text: resistor (page 1-22). PT-100 sensors are not useful below 14 K for metrology and are of limited use below , 1-28 PT-100 Platinum RTDs PT-100 Platinum RTDs · Follows Lake Shore extended standard , PT-100 platinum resistance thermometers (PRTs) are an excellent choice for use as cryogenic , calibration available 1. If your application requires more than one platinum resistor , up to five , ) 891-2244 Fax: (614) 818-1600 www.lakeshore.com EMail: sales@lakeshore.com PT-100 Platinum RTDs 1-29


Original
PDF PT-100 IMI-7031 PT-102 PT-103 PT-111 PLATINUM RESISTOR PT 100 sensor installation PT-100 RTD 3 wire sensor rosemount pt 100 temperature sensor PT-100 temperature sensor Pt100 Platinum Sensing Resistors PT-100 RTD 3 wire PT-111 PT-103 pt100 calibration certificate
1996 - PT200 Platinum RTD reference table

Abstract:
Text: RLIN resistor values for a Pt100 RTD. FIGURE 2. Operation Without External Transistor. LOOP POWER , Pt100 RTD. Double (x2) all values for Pt200. TABLE I. RZ, RG and RLIN Resistor Values for Pt100 RTD , RLIN2 Standard 1% Resistor Values for Three-Wire Pt100 RTD Connection with Linearization. LINEARIZATION , applications. Table I provides the 1% resistor values for a three-wire Pt100 RTD connection. Table II shows , RANGE: 9V to 40V q HIGH PSR: 110dB min q HIGH CMR: 80dB min Pt100 NONLINEARITY CORRECTION USING


Original
PDF XTR103 4-20mA 110dB Pt100 XTR103 4-20mA, RCV420 PWS740 ISO122 PT200 Platinum RTD reference table pt100 to 4-20 ma ic RTD SENSING CIRCUIT 4-20mA pt100/RTD PT100 circuit diagram temperature measurement rtd rtd pt100 4-20ma wiring diagram PT200 rtd chart xtr105 MODEL Pt100 transmitter 4...20 mA constant current source rtd circuits
maxim pt100 interface

Abstract:
Text: feedback compensates PT100 transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature transducer, and explains a simple analog approach , reliable standard available for temperature measurement. The PT100 RTD is described by the following , 0 1 2 3 4 5 7 8 9 200 175.84 *RTD PT100 table showing the relation , eliminates the effect of voltage drops in the two connecting wires. You can connect a PT100 RTD to the


Original
PDF PT100 MAX4236 MAX4237 com/an3450 AN3450, APP3450, Appnote3450, maxim pt100 interface DIN 17006 pt100 TRANSFER FUNCTION pt100 sensor interface WITH ADC pt100 maxim signal conditioning circuit for pt100 MAX4236 pt100 pt100 sensor interface WITH ADC for max197 PT100 IEC 751 Resolution current source pt100
2014 - Y20100

Abstract:
Text: RTD Simulator Vishay Foil Resistors Handy Resistor Simulates  RTD Temperature Outputs, such as PT-100 and PT-1000 FEATURES AND BENEFITS • Temperature coefficient of resistance (TCR): â , certification and printed temperature on the resistor itself. Connect an RTD and instantly read the temperature indicated on the resistor itself. Better than a decade box—faster, easier, and much less , regulated with respect to temperature and humidity. The only resistor with internal climate isolation


Original
PDF PT-100 PT-1000 27-Apr-2011 Y20100 y2010 rtd simulator
2010 - pt100/RTD PT100

Abstract:
Text: Data Sheet DS/TTH200-EN Head mounted Temperature Transmitter TTH200 HART, Pt100 (RTD , EDD Contents Head mounted Temperature Transmitter TTH200 HART, Pt100 (RTD), thermocouples , .13 Head mounted Temperature Transmitter TTH200 HART, Pt100 (RTD), thermocouples, Electrical isolation , Resistance thermometers / Resistors Resistance thermometer Pt100 in accordance with IEC 60751, JIS C1604 , communication resistor Maximum power consumption P = Us x 0.022 A e.g., Us = 24 V Pmax = 0.528 W 3


Original
PDF DS/TTH200-EN TTH200 Pt100 DS/TTH200seconds 3KXT231002R1001 DS/TTH200-EN pt100/RTD PT100 MIL-T-24388 PT200 reference table PT50 temperature sensor PT200 RTD reference table PT200 rtd ni1000 DIN 43760 PT100 B DIN 43729 rtd pt100 sensor JIS C1604 PT100 IEC 751
Supplyframe Tracking Pixel