The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1580 Linear Technology IC VREG FIXED POSITIVE REGULATOR, Fixed Positive Single Output Standard Regulator
RH137KDICE Linear Technology IC VREG ADJUSTABLE NEGATIVE REGULATOR, UUC3, DIE-3, Adjustable Negative Single Output Standard Regulator
RH137HDICE Linear Technology IC VREG ADJUSTABLE NEGATIVE REGULATOR, UUC3, DIE-3, Adjustable Negative Single Output Standard Regulator
LT1584 Linear Technology IC VREG FIXED POSITIVE REGULATOR, Fixed Positive Single Output Standard Regulator
LM317HVH Linear Technology IC VREG 1.2 V-57 V ADJUSTABLE POSITIVE REGULATOR, MBCY3, TO-39, 3 PIN, Adjustable Positive Single Output Standard Regulator
LT117AHVH Linear Technology IC VREG 1.25 V-60 V ADJUSTABLE POSITIVE REGULATOR, MBCY3, TO-39, 3 PIN, Adjustable Positive Single Output Standard Regulator

PT100 WIRING standard Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2013 - RMPT50BD

Abstract:
Text: converter, which converts it to a standard signal. Converters for Universal Pt100 probes have: â , , 0–20 mA, and 4–20 mA The products in the Universal Pt100 family allow wiring of Pt100 probes in 2 , . 5 Measurement Signals for Thermocouples and Pt100 Probes , . 6 Converters for Universal Pt100 Probes . 6 Converters for Optimum Pt100 Probes


Original
PDF 8501CT0502R07/13 Pt100 NSYTRV62PE NSYTRV42PE 8501CT0502R07/13 8501CT0502, RMPT50BD 02-64 4A20 rmcn22bd schneider electric Pt100 schneider Pt100 sensor
TR800

Abstract:
Text: , K, and Pt-100 RTD Bottom View of Cover Fixed-Range Units Offered in Standard or Special , process signals, including J, K, and Pt100 inputs. Each transmitter offers 2 to 3-wire compensation and linearization for Pt-100 , and ice point reference compensation for thermocouples that are voltage linear. On , of span Adjustability: ±25% for both zero and span Burnout Detection: Upscale-standard Standard , SPAN RTD: 20°C (36°F) min, 500°C (900°F) max TC: 10mV min span * 0+50 INPUT RTD: Pt-100 , 2


Original
PDF TR800 Pt-100 TR800 4-20mA) 4-20mA RTD PT100 3wire rtd pt100 4-20ma wiring diagram RTD PT-100 PT-100 RTD 3 wire rtd pt100 sensor 3 wire pt100 sensor wiring diagram PT-100 wiring diagram PT100 temperature sensor 0-400 PT-100 RTD 3 wire transmitter
MCHSML000M

Abstract:
Text: 3VA max. +/- 2% of FSD See standard items below J or K thermocouple or PT100 - 3 wire T/couple , wiring sockets see page 33. For thermocouples, PT100 and other applicable types of sensor see page 26 , 230Vac PJ32 S2 Input 4-20 mA 6 230Vac 12Vac/dc 14 STANDARD ITEMS PT100 7 , 10Vdc on/off Panel cut-out : 70 x 45 STANDARD ITEMS Output Type Input Type 1 relay NTC PT100 , simple on/off or proportional control. Options for J/K thermocouples and PT100 RTDs are available with


Original
PDF PT100 264Vac/dc 100-240Vac 24Vac/dc RS485 MCHSML000M IR32C0LBR0 PT100 connected diagram MCHTER00L0 IR32S0LBR0 IR32W00000 rtd pt100 4-20ma wiring diagram pt100 relay 2kw TRIAC 110v 230vac 12vac 5VA transformer
rtd pt100 4-20ma wiring diagram

Abstract:
Text: , PT100 , 4-20mA o o = -99 to 700 C (999 F) o o = -99 to 300 C (570 F) o = -99 to 999 C or F o , +/- 0.6% of scale range 14 Panel cut-out 45 x 45 mm +0.5 STANDARD ITEMS SPECIFICATION , thermocouple inputs PT100 & 4-20mA inputs 10 programmable alarm options Direct or reverse action Programmable set-point limits J T/c T T/c K/N T/c PT100 4-20mA sensor 4-20mA L Scale ranges: 7 4-20 mA input 10 2 6 8 5 Alarm RTD - + PT100 4-20 mA 110Vac


Original
PDF DTC410 PT100, 4-20mA 24Vac/dc 110Vac, 220-240Vac, DTC410-01-230 DTC410-02-24 DTC410-02-110 rtd pt100 4-20ma wiring diagram pt100 4-20mA Digital temperature controller with PT100 rtd PT100 WIRING standard Tempatron F Series Digital temperature controller with PT100 DTC410-01-110 rtd pt100 A sensor DTC410-01-230
pt100 sensor JIS C1604 range M type A

Abstract:
Text: transmitter have been certified to conform with the JIS Flameproof structure standard . For this reason, use , STANDARD SPECIFICATIONS Construction Case Aluminum alloy Converter Input type (Select by SFC , (J), SK(K), ST(T) SE(E) SN(N), SR(R), SS(S), SB(B) Resistance temperature detector (RTD) Pt100 , /internal selectable from an SFC Sensor model Pt100 (by specifying 'C' of additional specifications , % RH (No condensation) SB(B) 400~1820°C 200~1820°C Additional features Pt100 -200~850


Original
PDF SS2-ATT110-0100 ATT61/71 ATT61/71 ATT90 ATT61/71. ATT90 SS2-ATT900-0100. pt100 sensor JIS C1604 range M type A rtd pt100 sensor JIS C1604 3 wire pt100 sensor wiring diagram Yamatake pt100 pt100 jis Pt100 3 wire yamatake yamatake Sfc PT100 Platinum Resistance Temperature Detector Yamatake converter jPT100
2002 - wieland cores PT100

Abstract:
Text: or earth loops are ruled out due to advanced technology. They ensure that the analog standard signals , , temperature input modules for Pt100 /RTD sensors and thermocouples are also available, with or without electrical isolation. All the modules are intended for installation on standard DIN rail. The following types are available: One temperature input range/one standard signal output Two defined temperature input ranges/two standard signal outputs, input and output characteristics can be freely selected Four freely


Original
PDF
PT250 RTD

Abstract:
Text: : selectable full scales (200mV to 500V) °C or °F temperature measurements ( Pt100 -250-500-1000, Ni100, TC , inputs: TC temperature probes (J-K-ST-E, Pt100 -250-5001000) and resistance (0.02-0.2-2-20k) XX: SX , scale . Module BQ TRX Thermoresistance Inputs Type -200°C to +850°C Pt100 -328°F to +1562°F Pt100 -200.0°C to +200.0°C Pt100 -328°F to +392°F Pt100 -200.0°C to +200.0°C Pt250 -328°F to , to +392°F -60°C to +180°C -76°F to +356°F Pt100 Pt100 Pt250/ Pt100 Pt250/ Pt100 Pt1000/Pt500


Original
PDF UDM35 200mV Pt100-250-500-1000, Ni100, 20mA/10VDC RS485 RS232 pan48mm UDM35DS PT250 RTD BQ HSX Pt100-250-500-1000 PT250 table PT1000 table PT100 IEC B IEC61000-6-3 pt100/PT100 PT1000 CONVERSION TABLE
sensor TCJ

Abstract:
Text: compatibility of the instrument: pay extreme attention to wiring ). IC 912 Pt100 /TcJ/TcK UNPERMITTED USE , standard configuration passwords are not present. To enable them and assign them the desired value , connection of the 3rd wire ( Pt100 sensor) in "AL" folder it will appear the label "Pt3". For few seconds , . Ventilate the place in proximity to the instrument colling slits. ELECTRICAL WIRING Attention! Never , with the protection of a delayed 250 mA fuse. Probe cable ( Pt100 model), power supply cables and the


Original
PDF Pt100-TC 9IS22093 Pt100/TcJ/TcK sensor TCJ PT100 connected diagram pt100 TRANSFER FUNCTION PT100 3 wire connected diagram Invensys LOD voltage regulator 12v IC 555 as temperature controller pt100 model pt100 out PT100 temperature sensor water
omron pt100

Abstract:
Text: using DIP switch. · Multi-input support for thermocouple or Pt100 sensor input. · Selectable output , using multi-input support for thermocouple or Pt100 sensor input. Selecting Functions and Modes · , /°F, relay output non-fail safe/fail safe, setting protection. Terminal Wiring with Ferrules · Wire with 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 wiring ferrules. Model Number Structure Model Number , VAC/VDC Thermocouple/ Pt100 K8AB-TH12S 24VAC/VDC Note: Refer to page 3 for setting ranges


Original
PDF Pt100 N150-E1-01 75-344-7080/Fax: 0805-1M omron pt100 K8AB-TH12S motor PT100 connected diagram PT100 omron pt100 relay pt100 thermometer
pt100/RTD PT100

Abstract:
Text: display s J, K or E thermocouple or 3-wire Pt100 resistance thermometer input options s Relay, voltage , Fast sampling period 0.25 seconds s Case and wiring connections identical to GCS-23A FCS-13A and FCS , K-thermocouple Without second alarm PRICE INFORMATION AND ORDERING Pt100 resistance thermometer R * *For Pt100 input, please specify temperature range -19.9 to 99.9°C or -199 to 400°C Please note , material (1) K-thermocouple 0 to 999°C J-thermocouple E-thermocouple DIN Pt100 RTD J Pt100 RTD


Original
PDF 48-DIN Pt100 4-20mA GCS-23A FCS-13A FCS-23A GCS-132 FC-48-S nX48-3 pt100/RTD PT100 3 wire pt100 sensor wiring diagram RTD PT100 3wire pid temperature controller GCS-23A PT100 thermocouple analog temperature sensor pt100 for 0 to 400 c pt100 resistance thermometer GCS-132 PT100 RTD
PT1000 CONVERSION TABLE

Abstract:
Text: measurements ( Pt100 -250-500-1000, Ni100, TC J-K-S-T-E) Resistance measurements; selectable full scales (20 , : TC temperature probes (J-KS-T-E, Pt100 -250-5001000) and resistance (0.02-0.2-2-20k) XX: SX: SY , +356°F Pt100 Pt100 Pt100 Pt100 Pt250 Pt250 Pt500 Pt500 Pt1000 Pt1000 Ni100 Ni100 ±(0.2 , °C -328°F to +392°F -60°C to +180°C -76°F to +356°F Pt100 Pt100 Pt250/ Pt100 Pt250/ Pt100 Pt1000 , /DC voltage 90 to 260V ( standard ) 18 to 60V (on request) Excitation output 30VA/12W (90 to


Original
PDF UDM40 200mV Pt100-250-500-1000, Ni100, 20mA/10VDC RS485 RS232 UDM40DS PT1000 CONVERSION TABLE PT1000 table 20-200-500V PT100 IEC B PT100 tempered NPN DGT PT1000 RTD udm40 PT250 table PT500 RTD
Cu53 rtd

Abstract:
Text: signals between 0/4…20 mA. The special device K63 analyzes standard PT100 /NI100 acc. to IEC 751, as well as Pt100 acc. to Gost, also CU50, CU53 CU100 and CuZn100 acc.to Gost. Moreover, standard , in zone 2 I HART® I Removable terminal blocks I Connection of PT100 sensors acc , supply unit 20…250 VAC 40…70 Hz 20…125 VDC ð 3 W Input circuits Voltage input Pt100 Ni100 thermocouple (IEC 751), 2, 3 and 4-wire technology, acc. to Gost: PT100 , Cu50, Cu53, Cu100


Original
PDF IM34-12Ex-CRi/K63 IM34-12EX-CRI/K63 PT100/NI100 Pt100 CU100 CuZn100 2013-07-13T20 D-45472 Cu53 rtd PT100 IEC 751
BQ HSX

Abstract:
Text: scales (200mV to 500V) °C or °F temperature measurements ( Pt100 -250-500-1000, Ni100, TC J-K-S-T-E , input: TC temperature probes: J-K-ST-E, Pt100 -250-5001000 and resistance 0.02-0.2-2-20k XX: SX: SY , °C + 3182°F + 400°C + 752°F BQ TRX Thermoresistance -200°C to +850°C Pt100 -328°F to +1562°F Pt100 -200.0°C to +200.0°C Pt100 -328°F to +392°F Pt100 -200.0°C to +200.0°C Pt250 -328°F to +392°F , °C -328°F to +392°F -200,0°C to +200.0°C -328°F to +392°F -60°C to +180°C -76°F to +356°F Pt100


Original
PDF 200mV Pt100-250-500-1000, Ni100, 20mA/10VDC RS485 RS232 USCDS040706 RS232 USCDS0407063 BQ HSX BQ lSX PT500 RTD PT1000 CONVERSION TABLE PT500 thermocouple PT500 Resistance Table PT1000 table CONVERSION SY 356 PT1000 table Pt100-250-500-1000
JIS C1604-1989

Abstract:
Text: PT100 RS-485 CR 1mA External Wiring RS-485 cannot be used when connected to PLC , '1) b6 0 0 0 0 0 0 1 Wiring to empty external contact 0 0 0 0 0 1 , than 2 errors occurring at the same time. 0 = normal; 1 = error. #31 H'4083 *1: Wiring for analog input should adopt cables of PT100 temperature sensor or double shielding cable and should be separated from other power cables that may cause interference. Please use 3 wires for PT100 . *2: Terminal


Original
PDF VP04PT-H2 RS-485 JIS C1604-1989 pt 4115 K2098 rtd pt100 sensor JIS C1604 DVP04PT-H2 pt100 jis 63b15 4082 C1604-1989 K121
temperature PT100

Abstract:
Text: to. 1 (A) 2 (B) 3 (A) 4 (B) 5 NC Pt100 6 (B) 7 NC 8 (B) TY7033Z0P01 Wiring and color , HTY7033 Ceiling Mounted Sensor uses a Pt100 platinum film temperature sensing element and a polymer , Z 1 0 0 P P P 00 00 01 Humidity (1-5 V) + Temperature ( Pt100 ) Lead wire output Temperature ( Pt100 ) Lead wire output Temperature ( Pt100 ) Modular jack output 1 Specifications Item , 500 V DC 20 M or more Installation Installed in return ceiling opening Wiring Lead wire: Length


Original
PDF AB-5965 HTY7033/ TY7033 HTY7033 Pt100 TY7033 AB-5965 temperature PT100 Yamatake pt100 PT100 double PT100 temperature sensor long sensing element TY7033Z0P00 Pt100 3 wire yamatake HTY7033T1P00 fp3 matsushita sensor PT100 PT100 temperature sensor data sheet
2010 - K8AB-TH11S

Abstract:
Text: Simple function settings using DIP switch. · Universal-input support for thermocouple or Pt100 sensor , universal-input support for thermocouple or Pt100 sensor input. Selecting Functions and Modes · The following , non-fail safe/fail safe, setting protection. Terminal Wiring with Ferrules · Wire with 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 wiring ferrules. Third-party Certification of CE Mark Compliance, Certified UL Standard Compliance, and Certified TÜV and SUD Standard Compliance Model Number Structure Model


Original
PDF Pt100 K8AB-TH11S K8AB-TH12S omron pt100 PT100 omron PT100 medical application PT100 omron SENSOR t thermocouple switch PT100 connected diagram PFP-50N PFP-100N
PT100 DIN

Abstract:
Text: < 0.7 sec. Humidity < 100% RH, condensing Pt100 Standard IEC/DIN/EN 60 751-2 Protection , TE2 - Pt100 Temperature Sensors Case in stainless steel Wetted parts in acid-proof, stainless steel or PEEK Wide range of process connections Pt100 sensors, single or duplex element DIN A or B (1/1 or 1/3) elements Standard or fast response sensor tip Electrical connection M12 or DIN43650 plug , -5 TE20-Z TE2x-3 TE2x-1xx2 Description The TE2 Pt100 temperature sensor system has a stainless steel


Original
PDF Pt100 DIN43650 TE20-Z DIN43650A TE2/M12 3650-A EN/2012-06-19 PT100 DIN PT100 temperature ZED601
2011 - Ni120

Abstract:
Text: Pt100 , Ni100, Ni120, Cu10 RTD or 4-20 mA inputs Protects circuit boards against corrosion and moisture , wiring diagram, see page 86. SUPPLEMENTAL MONITORING Simplified Circuit Diagram M RTD x 8 , Pt100 (default), Ni100, Ni120, Cu10 RTD Range - 40 to 200° C with open and short detection . Analog Range 4-20 mA Accuracy 1° C ( Pt100 , Ni100, Ni120) (Cu10) 3° C (4-20 mA) 0.1 mA Lead Compensation Up to 20 Communications Modbus RTU® Conformally Coated Standard feature Warranty 5 years Mounting DIN


Original
PDF Pt100 Ni100, Ni120, Pt100, Ni120) RS-485 sio-rtd-02-00 Ni120 pt100 circuit diagram Ni100 modbus RS485 circuit modbus circuit pt100/Ni120
2010 - 931S-A2A5N-OP

Abstract:
Text: temperature measurements. For example, PT100 signals in 2-, 3and 4-wire systems are converted into standard , using standard Bulletin 1492 terminal block jumpers on most Bulletin 931H devices Wiring diagrams , 931H-P2A2N-OP Specifications Active Converter, PT100 /RTD Wiring Diagram Standards Compliance , loss 931H-P2C1D-DC Specifications Active Converter, PT100 /RTD Wiring Diagram Standards , Product Selection · High-Density Signal Conditioners Page 8 · Standard Signal Conditioners Page


Original
PDF 931-TD001A-EN-P 931S-A3C2D-DC 931S-C3C3J-DC 931U-C9A2C-OP 931U-C9C7C-BC 931S-A2A5N-OP 931S-F1C2D-DC 931H-C2C2D-DC pt100/signal conditioning circuit for pt100 E10314 931H-P2A2N-OP 931S-T9C2D-DC pt100 signal conditioner 931S-A2A2N-DC 931H-T2C1D-DC
Not Available

Abstract:
Text: temperature measurements ( Pt100 -250-500-1000, Ni100, TC J-K-S-T-E) Resistance measurements: selectable full , probes (J-KS-T-E, Pt100 -250-5001000) and resistance (0.02-0.2-2-20kΩ) TF1: 0.001Hz to 50kHz for DC , -200.0°C to +200.0°C -328°F to +392°F -60°C to +180°C -76°F to +356°F Pt100 Pt100 Pt100 Pt100 Pt250 Pt250 Pt500 Pt500 Pt1000 Pt1000 Ni100 Ni100 ±(0.2%RDG +2DGT) ±(0.2%RDG +4DGT , °C -328°F to +392°F -60°C to +180°C -76°F to +356°F Pt100 Pt100 Pt250/ Pt100 Pt250/ Pt100 Pt1000


Original
PDF UDM35 NEMA12, 200mV Pt100-250-500-1000, Ni100, 001Hz 50kHz) UDM35 RS485
Digital Panel Meters

Abstract:
Text: : selectable full scales (200mV to 500V) °C or °F temperature measurements ( Pt100 -250-500-1000, Ni100, TC , probes (J-KS-T-E, Pt100 -250-5001000) and resistance (0.02-0.2-2-20k) TF1: 0.001Hz to 50kHz for DC , to +392°F -200.0°C to +200.0°C -328°F to +392°F -60°C to +180°C -76°F to +356°F Pt100 Pt100 Pt100 Pt100 Pt250 Pt250 Pt500 Pt500 Pt1000 Pt1000 Ni100 Ni100 ±(0.2%RDG +2DGT) ±(0.2 , -76°F to +356°F Pt100 Pt100 Pt250/ Pt100 Pt250/ Pt100 Pt1000/Pt500 Pt1000/Pt500 Ni100 Ni100


Original
PDF UDM35 200mV Pt100-250-500-1000, Ni100, 001Hz 50kHz) 20mA/10VDC RS485 RS232 IP67nel Digital Panel Meters BQ 24 Transistor BQ HSX PT1000 CONVERSION TABLE pnp 1000V 2A BQ lSX PT500 DIN d connector screw lock torque bq 62 PNP 1000V 100a
PT1000 CONVERSION TABLE

Abstract:
Text: ( PT100 3-WIRE 100 3850 PPM/°C (DIN 43760 JIS C1604-1989)/ NI100 / PT1000 / NI1000) and converts them , and wiring . For detailed program design and applicable instructions, please refer to "DVP-ES2 , the I/O terminals; otherwise serious damage may occur. Check all the wiring again before switching on , port 61.5 62 70 78 Unit: mm -1- [ Figure 2 ] External Wiring 1 .53 mA(PT1 00 , la ss 3 Gro un ding (1 00 o r less) Note 1: Wiring for analog input should adopt cables of


Original
PDF 5011686600-E2P0 DVP-1130530-01 DVP04PT-E2 PT100 C1604-1989 NI100 PT1000 NI1000) 16-bit D9900 PT1000 CONVERSION TABLE Ni1000 CONVERSION TABLE PT1000 table CONVERSION PT1000 temperature sensor 04PT-E2 DVP-04PT-E2 KD 472 M mov Ni1000
2004 - PT100 omron SENSOR

Abstract:
Text: ■Unit Description The CJ1W-TS562 is a 6-channel input unit for Pt100 and Pt1000 RTD’s. It can , access) • Select input types ( Pt100 /Pt1000) • Select filter functions • Select number of active inputs (1-6) Terminal Block latch • Slide down to remove • Slide up to lock ■Wiring , input wiring away from power lines including AC power supply lines and high-power lines. Do not run the , the PLC. In case of shielded sensor wiring , connect the shields to the same grounding point as the


Original
PDF CJ1W-TS562 CJ1W-TS562 Pt100 Pt1000 NL-2132 634292-5A PT100 omron SENSOR
Not Available

Abstract:
Text: measurements; selectable full scales (200mV to 500V) °C or °F temperature measurements ( Pt100 , /AC TRX: signal inputs: TC temperature probes (J-KS-T-E, Pt100 -250-5001000) and resistance , -200.0°C to +200.0°C -328°F to +392°F -60°C to +180°C -76°F to +356°F Pt100 Pt100 Pt100 Pt100 Pt250 Pt250 Pt500 Pt500 Pt1000 Pt1000 Ni100 Ni100 ±(0.2%RDG +2DGT) ±(0.2%RDG +4DGT , °C -328°F to +392°F -60°C to +180°C -76°F to +356°F Pt100 Pt100 Pt250/ Pt100 Pt250/ Pt100 Pt1000


Original
PDF 200mV Pt100-250-500-1000, Ni100, 001Hz 50kHz) 20mA/10VDC RS485 RS232 RS232
2011 - Ni120

Abstract:
Text: Individually-selectable Input Type Can be mounted in hazardous areas Flexible; can be used with Pt100 , Ni100, Ni120 , Circuit Diagram Rejects noise from motor monitoring applications For detailed wiring diagram, see page , ) RTD Types RTD Range Analog Range Accuracy ( Pt100 , Ni100, Ni120) (Cu10) (4-20 mA) Lead , 56 mm (2.2”) Pt100 (default), Ni100, Ni120, Cu10 -40 to 200˚ C with open and short detection 4-20 mA 1˚ C 3˚ C 0.1 mA Up to 20 Ω Modbus RTU® Standard feature 5 years DIN, Surface


Original
PDF Pt100, Ni100, Ni120) RS-485 SIO-RTD-02-00 Pt100 Ni120, Ni120 pt100/Ni120