The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LM134H-6 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN
LM134H-3 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN
LTC2997IDCB#PBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C
LTC2997CDCB#PBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C
LTC2997CDCB#TRMPBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: Commercial
LTC2997HDCB#TRPBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 125°C

PT100 SENSOR Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1998 - PT100 4 wire temperature sensor

Abstract: PT100 connected diagram PT100 2 wire temperature sensor PT100 SENSOR PT100 3 wire temperature sensor PT100 bridge example PT100 temperature sensor resolution PT100 3 wire connected diagram PT100 bridge 3 wire pt100 sensor wiring diagram
Text: fibre-optic bus Connections Plug-in for PT100 sensor (2-wire, 4-wire) Data port II/O system , G Plug-in connector GND for PT100 sensor Input, PT100 sensor pick-off Input, PT100 sensor pick-off Constant-current source for PT100 sensor Beckhoff II/O System Page 9 of 10 Plug-in , : Example: Page 10 of 10 Description GND for PT100 sensor Input, PT100 sensor pick-off Input, PT100 sensor pick-off Constant-current source for PT100 sensor (1mA) GND for PT100 sensor Input, PT100


Original
PDF PT100 D-33415 PT100 4 wire temperature sensor PT100 connected diagram PT100 2 wire temperature sensor PT100 SENSOR PT100 3 wire temperature sensor PT100 bridge example PT100 temperature sensor resolution PT100 3 wire connected diagram PT100 bridge 3 wire pt100 sensor wiring diagram
2013 - Not Available

Abstract: No abstract text available
Text: Pt100 sensor Measuring range -200.850°C Ambient temperature -10.70°C Accuracy 0.3°C Battery , Temperature sensor Pt100 , 2-wire (DIN/EN/IEC 60751) Battery: Energizer Lithium FR6 L91 AA , status Battery clip Terminals for Pt100 sensor + Control buttons Note: A Lithium battery , Battery operated digital thermometer 3A/DN38 hygienic, Pt100 sensor 1/6 DIN B Sensor , fast response, 3A , operated digital thermometer Clamp connection, Pt100 sensor 1/3 DIN B Sensor , fast response, clamp


Original
PDF Pt100 EN/2013-03-03
Siemens PT100 temperature sensor

Abstract: PT100 temperature sensor PT100 B DIN 43729 PT100 temperature sensor data sheet PT100 temperature sensor water ISO-228 g1 ISO228 thread Siemens temperature sensor sensor PT100 ISO228
Text: Pt100 sensor inputs · In conjunction with MULTIREG and INTEGRAL RS. Use The FT-TP/. immersion , temperature measurement over a wide range with controllers equipped with a Pt100 sensor input, e.g , Technical design The Pt100 temperature sensor is fitted with a platinium measuring element with a , sheet 1714 for technical information on the Pt100 sensor element. The sensor FT-TP/. comprises a , 1 797 FT-TP/100 FT-TP/400 Immersion temperature sensor for HVAC systems Immersion


Original
PDF FT-TP/100 FT-TP/400 Pt100 ISO228/1 9M427 Siemens PT100 temperature sensor PT100 temperature sensor PT100 B DIN 43729 PT100 temperature sensor data sheet PT100 temperature sensor water ISO-228 g1 ISO228 thread Siemens temperature sensor sensor PT100 ISO228
1999 - Not Available

Abstract: No abstract text available
Text: 100% RH Transmitter with Pt100 Sensor Wall Mount, 0 to 100% RH Transmitter Wall Mount, 0 to 100% RH Transmitter with Pt100 Sensor Flange for HX801, 100 mm (3.9") dia. Ordering Example: HX801T is a 220 mm (8.6") Duct Mount 0 to 100% RH Transmitter with Pt100 Sensor , $539. Hu-28 Omega Engineering , Basic Unit ߜ Monolithic IC Humidity Sensor ߜ 2 Wire, 4-20mA Transmitter ߜ Output Linearized With % RH ߜ Temperature Compensated Output ߜ Available With Pt100 RTD Output ߜ 40~200 mV Output Test


Original
PDF HX801, HX802 HX801/802 4-20mA Pt100 HX801/HX802 10-hour HX801 HX801T
SEM203P

Abstract: current source pt100 PT100 standard IEC 60751 accuracy JISC1604 RS363-0238 PT100 SENSOR PT100 double XQ-126-RS SEM20 SEM203/TC
Text: The SEM203/P head mounted temperature transmitter connects to any standard pt100 resistance sensor , mA Precision resistance decade box to simulate PT100 sensor . Screw driver flat blade 3mm wide PT100 resistance tables Current meter (user trim) · Refer to figure 3, connect sensor or , period. · Set calibrator to the equivalent resistance of the pt100 sensor , at required trim point , allow 1 minute warm up period. · Set calibrator to the equivalent resistance of the pt100 sensor


Original
PDF PT100 XQ-126-RS SEM203P current source pt100 PT100 standard IEC 60751 accuracy JISC1604 RS363-0238 PT100 SENSOR PT100 double XQ-126-RS SEM20 SEM203/TC
2002 - RTD PT100 3wire

Abstract: MCR-SL-PT100-LP-I Pt100 3 wire pt100 temperature sensor circuit connection namur NE 43 pt100 4-20mA MCR-SL-PT100 rtd pt100 4-20ma connections pt100 temperature transducers Phoenix/pt100 4-20 ma
Text: range. The devices are supplied with the following default configuration: PT100 sensor , 0.100 , supplied with the following default configuration: PT100 sensor , 0.100°C (32.212ºF) measuring range, 3 , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4wire technology ­ Can be mounted on , Universal PC programmable temperature measuring transducers convert temperature signals from PT100


Original
PDF PT100 MCR-SL-PT100-LP-I RTD PT100 3wire MCR-SL-PT100-LP-I Pt100 3 wire pt100 temperature sensor circuit connection namur NE 43 pt100 4-20mA MCR-SL-PT100 rtd pt100 4-20ma connections pt100 temperature transducers Phoenix/pt100 4-20 ma
PT100 application note

Abstract: pt100 sensors PT100 IEC B PT100 temperature sensor class B application note pt100 pt100 thermometer RTD PT100 3wire PT100 temperature transducer 3 wire pt100 temperature sensor circuit connection MCR-SL-HT-PT100-I
Text: default configuration: PT100 sensor , 0.100°C (32.212ºF) measuring range, 3-wire termination. 5 , . Configuration The devices are supplied with the following default configuration: PT100 sensor , 0.100 , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4-wire technology ­ For installation , transducers convert temperature signals from PT100 resistance thermometers to analog 4.20 mA signals. On


Original
PDF PT100 MCR-SL-HT-PT100-I MCR-FL-HT-PT100-I PT100 application note pt100 sensors PT100 IEC B PT100 temperature sensor class B application note pt100 pt100 thermometer RTD PT100 3wire PT100 temperature transducer 3 wire pt100 temperature sensor circuit connection MCR-SL-HT-PT100-I
2002 - MCR-SL-HT-PT100-I

Abstract: pt100 sensors PT100 SENSOR PT100 temperature transducer 3 wire PT100 2 wire temperature sensor -200 to 650 rtd pt100 sensor DIN43729
Text: configuration: PT100 sensor , 0.100°C (32.212ºF) measuring range, 3-wire termination. Dimensional drawing , Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 5. Installation in the Sensor Connection Head , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4-wire technology ­ For installation , convert temperature signals from PT100 resistance thermometers to analog 4.20 mA signals. On the output


Original
PDF PT100 MCR-SL-HT-PT100-I MCR-SL-HT-PT100-I pt100 sensors PT100 SENSOR PT100 temperature transducer 3 wire PT100 2 wire temperature sensor -200 to 650 rtd pt100 sensor DIN43729
MCR-SL-PT100-LP-I

Abstract: PT100 application note RTD PT100 3wire PT100 SENSOR PT100 IEC 751 PT100 temperature transducer 3 wire pt100 thermometer pt100 sensors application note pt100 mcr pt100
Text: configuration: PT100 sensor , 0.100°C (32.212ºF) measuring range, 3-wire termination. Headquar ters , default configuration: PT100 sensor , 0.100°C (32.212ºF) measuring range, 3-wire termination. To , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4wire technology ­ Can be mounted on , temperature signals from PT100 resistance thermometers to analog 4.20 mA signals. On the output side the


Original
PDF PT100 MCR-SL-PT100-LP-I MCR-SL-PT100-LP-I PT100 application note RTD PT100 3wire PT100 SENSOR PT100 IEC 751 PT100 temperature transducer 3 wire pt100 thermometer pt100 sensors application note pt100 mcr pt100
ni500 DIN 43760

Abstract: PT500 IEC 751 Resistance characteristic Ni1000 Resistance characteristic Pt1000 W5Re-W26Re ni1000 DIN 43760 PT100 IEC 751 accuracy Ni100 sensor pt100 4-20 ma RTD PT1000 conversion
Text: temperature range. The devices are supplied with the following default configuration: PT100 sensor , 0.100 , : internal ( Pt100 ) or external (0.80°C [32.176ºF]) · Cold junction accuracy: ±1 K Voltage sensor (mV , 5. Configuration The devices are supplied with the following default configuration: PT100 sensor , . Failure information in the event of sensor breaks or sensor short circuit can be set according to NE 43 , Measuring Span Pt100 Pt500 Pt1000 according to IEC 751 Resistance thermometer (RTD) -200 to


Original
PDF
PT100 IEC 751

Abstract: en60751 slide linear potentiometer pt100 PT100 Thermocouple Amplifier PT100 temperature sensor data sheet transducer 61326 pt100 datasheet 0.05 BS1904 PT100 IEC 751 1/2 d 400 transistor
Text: . 2.0 SPECIFICATION @ 24 ºC 2.1 RTD INPUT ( Pt100 ) Sensor Range Minimum Span*¹ Linearisation , connection to provide a (4 to 20) mA current loop output. The Pt100 sensor shown would normally take the , INPUT SENSOR RANGES Thermocouple Type TC Type K TC Type J TC Type T TC Type R TC Type S TC Type , quick selector or via PC) 1000 m Sensor type: Burnout: ºC/ºF: Output: PC: Hi/Lo: Filter: Tag: User , screened cable is used for the input signal wires for cable runs greater than one metre. For Pt100 inputs


Original
PDF SEM215 to1000 to1200 to1600 PT100 IEC 751 en60751 slide linear potentiometer pt100 PT100 Thermocouple Amplifier PT100 temperature sensor data sheet transducer 61326 pt100 datasheet 0.05 BS1904 PT100 IEC 751 1/2 d 400 transistor
2015 - el 7406

Abstract: ZPH1-5216
Text: . 20 mA output Temperature Media Secondary coil Pt100 sensor www.baumer.com Data sheet , compensation of the conductivity signal, which is very temperature dependent. The Pt100 sensor signal is also , „ AFI5 split version with remote sensor „„ Separate 4.20 mA output for conductivity , 14 selectable ranges Temperature ( sensor incl. transmitter @ 25°C ambient) Cond./conc , Left side ≤ 0.05%/K 1) AFI5: ≤ 0.05%/K + 0.005%/K pr. m sensor cable IEC 60068.2.6 - test


Original
PDF EN/2015-03-17 el 7406 ZPH1-5216
EN60079-14

Abstract: sem210x pt100 temperature sensor circuit diagram MARKING x328 Universal GAS SENSOR pt100 ANSI en60751 EN60584 current source pt100 EEx ia IIC T6
Text: loop output. The Pt100 sensor shown would normally take the form of a probe assembly with a three wire , in-head temperature transmitter that accepts any commonly used temperature sensor , slidewire transducer , Accuracy*² Input Impedance Thermal Drift Zero Span 2.0 SPECIFICATION @ 20 ºC 2.1 RTD INPUT ( Pt100 ) Sensor Range Minimum Span*¹ Linearisation Basic Measurement Accuracy*² Thermal Drift Zero Span , , 4th order polynomial 5% 0.1 % FRI 0.01 %/ºC 2.5 OUTPUT 2.2 THERMOCOUPLE INPUT SENSOR RANGES


Original
PDF SEM210 Pt100 EN60079-14 sem210x pt100 temperature sensor circuit diagram MARKING x328 Universal GAS SENSOR pt100 ANSI en60751 EN60584 current source pt100 EEx ia IIC T6
PT100 standard IEC 60751 accuracy

Abstract: PT100 IEC 751 PT100 resistor pt100 temperature sensor circuit diagram temperature sensor pt100 sensor PT100 mtw 12 pt100 circuit diagram PT100 bridge signal converter pt100
Text: Murrelektronik temperature converter module works in conjunction with a temperature sensor PT100 (IEC 751/EN 60751) and converts the output from the sensor into a standard signal format of (0.10 V, 0.20 mA or 4.20 mA). The MTW module supplies a constant current to the PT100 resistor across, which develops a , between the MTW and the PT100 sensor to be covered, i.e. <5 m. For longer distances, 3-wire technology , data Supply voltage range Supply current Cable resistance (without PT100 ) Output signals


Original
PDF PT100) 6644333iable PT100 PT100 standard IEC 60751 accuracy PT100 IEC 751 PT100 resistor pt100 temperature sensor circuit diagram temperature sensor pt100 sensor PT100 mtw 12 pt100 circuit diagram PT100 bridge signal converter pt100
"Humidity Sensor"

Abstract: sensor PT100 dew point sensor pt100 datasheet temperature sensor pt100 PT100 temperature sensor humidity sensor PT100 temperature sensor datasheet PT100 pt100 smd
Text: humidity sensor + Platinum heating element / Pt100 sensor W= 3,81 x L= 7,7 x D= 0,4 mm 0 . 100 % RH , P14 Thermo Capacitive Humidity Sensor Heated Product The P14 Thermo was designed especially for , capacitive humidity sensor , based upon the famous P14 sensor , together with a heating element which is also , sensor array clearly to best in class. Advantages · · · · · · · · Application in dew point , comfortably even under dewing conditions 1 chip solution = sensor + heating element / Pt100-sensor


Original
PDF Pt100-sensor, "Humidity Sensor" sensor PT100 dew point sensor pt100 datasheet temperature sensor pt100 PT100 temperature sensor humidity sensor PT100 temperature sensor datasheet PT100 pt100 smd
pt100 calibration certificate

Abstract: TG12-0020 TGP-0104 pt100 0.00385 PB-3225 sensor data logger
Text: : Offload : Range : -50°C + 300°C / -58°F + 572°F Sensor Type : PT100 Probe PB-3225 Resolution : 1 , you w ill require: PT100 sensor probe (PB-3225) Tinytag interface cable (CAB-0007), PC with GLM for , *HPLQL 'DWD 6KHHW Tinytag Plus Temperature for PT100 probe TGP-0104 I ssue 9: 27 th February , No. of Readings Resolution Trigger Start Delayed Start Sensor Details IP Rating , , not the sensor range over which it will record. This equipment complies with part 15 of the FCC


Original
PDF PT100 TGP-0104 PB-3225 PB-3225 dayT100 PB-3225) CAB-0007) SW-0009) pt100 calibration certificate TG12-0020 TGP-0104 pt100 0.00385 sensor data logger
NI500 temperature

Abstract: Ni100 sensor PT100 4 wire temperature sensor PT500 IEC 751 Resistance characteristic Pt1000 PT500 temperature sensor PT500 sensor PtRh10-Pt Ni1000 temperature sensor PT100 2 wire temperature sensor
Text: temperature range. The devices are supplied with the following default configuration: PT100 sensor , 0.100 , . Configuration The devices are supplied with the following default configuration: PT100 sensor , 0.100 , . Failure information in the event of sensor breaks or sensor short circuit can be set according to NE 43 , Measuring Range Limits Minimum Measuring Span Pt100 Pt500 Pt1000 according to IEC 751 Resistance , Resistance sensor Connection type: 2, 3 or 4-wire termination With 2-wire termination, the cable


Original
PDF PT100 NI500 temperature Ni100 sensor PT100 4 wire temperature sensor PT500 IEC 751 Resistance characteristic Pt1000 PT500 temperature sensor PT500 sensor PtRh10-Pt Ni1000 temperature sensor PT100 2 wire temperature sensor
PT500 temperature sensor

Abstract: Pt1000 transmitter 4.20 mA Phoenix Ni1000 2-wire W5Re-W26Re IEC 751 PT500 SENSOR PT500 IEC 751 MoRe5-MoRe41 INTRINSICALLY SAFE PLC PT100 IEC B
Text: temperature range. The devices are supplied with the following default configuration: PT100 sensor , 0.100 , . Configuration The devices are supplied with the following default configuration: PT100 sensor , 0.100 , information in the event of sensor breaks or sensor short circuit can be set according to NE 43. This , Measuring Range Limits Minimum Measuring Span Pt100 Pt500 Pt1000 according to IEC 751 Resistance , Resistance sensor Connection type: 2, 3 or 4-wire termination With 2-wire termination, the cable


Original
PDF eebt02 PT500 temperature sensor Pt1000 transmitter 4.20 mA Phoenix Ni1000 2-wire W5Re-W26Re IEC 751 PT500 SENSOR PT500 IEC 751 MoRe5-MoRe41 INTRINSICALLY SAFE PLC PT100 IEC B
PT100 thermistor

Abstract: pt100 temperature sensor schematic pt100 schematic PT100 thermistor sensor pt100 temperature schematic PT100 3 wire thermistor SCHEMAT* PT100 PT100 4 wire temperature sensor PT100 2 wire temperature sensor lcd backlight
Text: accuracy we recommend a 4 wire class A Pt100 sensor . 19mm (0.75") Digit Height Simple Connection LED , DTM 910 LCD Type Pt100 Temperature Indicator The DTM 910 will give an accurate direct temperature reading in either °C or °F from a 2, 3 or 4 wire Pt100 thermistor*. Simple single step calibration , to correspond with a known accurate temperature. Stock Number Standard Meter Sensor DTM , As the Pt100 is a passive device, no voltages should be applied to the input terminals. DIMENSIONS


Original
PDF Pt100 20-turn Pt100 November/1997 PT100 thermistor pt100 temperature sensor schematic pt100 schematic PT100 thermistor sensor pt100 temperature schematic PT100 3 wire thermistor SCHEMAT* PT100 PT100 4 wire temperature sensor PT100 2 wire temperature sensor lcd backlight
2004 - pt100 temperature sensor circuit diagram

Abstract: MCR-SL-PT100-UI-SP PT100 bridge MCR-SL-PT100-UI PT100 DIN MCR-SL-PT100-UI-NC
Text: signal Behavior in the case of a sensor fault (configurable) IIN PT100 2-, 3-, 4-conductor connection , distances between PT100 sensor and MINI Analog module The value of all cable resistances must be exactly the , 8) ­ For long distances between the PT100 sensor and the MINI Analog module and different cable , MINI MCR-SL-PT100-UI . Configurable Temperature Transducer for PT100 Data Sheet Product , measuring transducer. It is suitable for the connection of PT100 resistance thermometers in acc. with IEC


Original
PDF MCR-SL-PT100-UI PT100 PT100 volta1562 pt100 temperature sensor circuit diagram MCR-SL-PT100-UI-SP PT100 bridge MCR-SL-PT100-UI PT100 DIN MCR-SL-PT100-UI-NC
2002 - hart protocol

Abstract: Resistance characteristic Pt1000 Pt1000 RTD Sensor Thermocouple Type K linearization Pt100 transmitter 4.20 mA ni1000 DIN 43760 Resistance characteristic Ni1000 Resistance thermometer mw PT500 SENSOR PT500 thermocouple
Text: default configuration: PT100 sensor , 0.100°C (32.212ºF) measuring range, 3-wire termination. 4 , 500 K 50 K 50 K · Cold junction: internal ( Pt100 ) · Cold junction accuracy: ±1 K Voltage sensor , supplied with the following default configuration: PT100 sensor , 0.100°C (32.212ºF) measuring range , resistance can be compensated. Failure information in the event of sensor breaks or sensor short circuit , MCR-FL-HT-TS-I-Ex 1.1. Input Signals Designation Measuring Range Limits Minimum Measuring Span Pt100


Original
PDF
temperature transmitter pt100 4-20ma atex

Abstract: rtd sensor pt100 PT100 SENSOR Resistance characteristic Ni1000 Resistance characteristic Pt1000 PT500 IEC 751 PT1000 thermocouple Thermocouple type PT100 thermocouple cable PT1000 application note
Text: . The devices are supplied with the following default configuration: PT100 sensor , 0.100 , . 7. Configuration The devices are supplied with the following default configuration: PT100 sensor , event of sensor breaks or sensor short circuit can be set according to NE 43. This measuring , Signals Designation Measuring Range Limits Minimum Measuring Span Pt100 Pt500 Pt1000 , +302°F) 10 K 10 K 10 K · · · · Resistance sensor Connection type: 2, 3 or 4


Original
PDF
sensor TCJ

Abstract: PT100 connected diagram pt100 TRANSFER FUNCTION PT100 3 wire connected diagram PT100 temperature sensor water IC 555 as temperature controller PT100 WIRING standard pt100 model Invensys 230v 12V power supply ic
Text: connection of the 3rd wire ( Pt100 sensor ) in "AL" folder it will appear the label "Pt3". For few seconds , / / / / / / / / / / / / / / / VALUE* U.M. (1) PARAMETER VISIBLE ONLY INTcJ/TcK MODELS. Pt100 Model works only with Pt100 sensor (3 wires) while TcJ and TcK Models work also with Pt100 sensor selectable by this parameter , with the protection of a delayed 250 mA fuse. Probe cable ( Pt100 model), power supply cables and the TTL serial cables should be distant from power cables. ( Pt100 model) Probe can be extended using a


Original
PDF Pt100-TC 9IS22093 Pt100/TcJ/TcK sensor TCJ PT100 connected diagram pt100 TRANSFER FUNCTION PT100 3 wire connected diagram PT100 temperature sensor water IC 555 as temperature controller PT100 WIRING standard pt100 model Invensys 230v 12V power supply ic
2001 - PT100 IEC 751

Abstract: MCR-SL-PT100-I-DC-24 MCR-SL-PT100 phoenix DIP switch settings MCR-SL-PT100 DC 24 MCR-SL-PT100-U-DC-24 pt 100 sensor pt100 temperature transducers PT100 type B iec 60751 PT-100 sensor
Text: Temperature Measuring Transducer for PT100 MCR-SL-PT100-.-DC-24 1. Description MCR-SL-PT100 temperature measuring transducers convert the measured values of the PT100 sensor (IEC rigid751/EN 60751) into electrically standardized analog signals. The sensor is supplied from the module with a low , increase the process safety, the modules are equipped with 3-way isolation. 2-, 3-, and 4-wire PT100 , Temperature Measuring Transducer for PT100 ­ MCR-SL-PT100-.-DC-24 2. Technical Data OUT 1 2 D


Original
PDF PT100 MCR-SL-PT100-. -DC-24 MCR-SL-PT100 PT100 rigid751/EN PT100 IEC 751 MCR-SL-PT100-I-DC-24 phoenix DIP switch settings MCR-SL-PT100 DC 24 MCR-SL-PT100-U-DC-24 pt 100 sensor pt100 temperature transducers PT100 type B iec 60751 PT-100 sensor
2008 - PT100 temperature sensor data sheet

Abstract: PT100 temperature sensor PT100 temperature sensor 3 wires PT1000 temperature sensor PT1000 Sensor Data 811A tube pt1000 class B, DIN EN 60751
Text: Cable Sensor , Pt100 /Pt1000 Sensors with 4-wire silicone cable for pockets or tubes 4-wire air , the nominal working range. The Pt100 sensor fits as an insert in sensor tubes with an internal , Application 230 Vac Pt100 /Pt1000 sensor 5 3 7 3 4 5 1 2 1 2 4 3 6 2 - + 1 , temperature sensor . Changes in temperature are reflected by changes in the electrical resistance, so that measuring the value of the resistance gives an analogue expression for the actual temperature. The Pt100


Original
PDF Pt100/Pt1000 Pt100 UK/2008-06-02 PT100 temperature sensor data sheet PT100 temperature sensor PT100 temperature sensor 3 wires PT1000 temperature sensor PT1000 Sensor Data 811A tube pt1000 class B, DIN EN 60751
Supplyframe Tracking Pixel