The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
ISL95810WIRT8ZR5481 Intersil Corporation ISL95810W PRE-PROGRAMMED TO LOWEST RESISTANCE SETTING, XDCP,
HI5714/8CB-T Intersil Corporation 1-CH 8-BIT RESISTANCE LADDER ADC, PARALLEL ACCESS, PDSO24
HI5714/4CB-T Intersil Corporation 1-CH 8-BIT RESISTANCE LADDER ADC, PARALLEL ACCESS, PDSO24
HI5714/6CB Intersil Corporation 1-CH 8-BIT RESISTANCE LADDER ADC, PARALLEL ACCESS, PDSO24
HI5714/7CB Intersil Corporation 1-CH 8-BIT RESISTANCE LADDER ADC, PARALLEL ACCESS, PDSO24
ISL43L710IUZ-T Intersil Corporation Ultra Low ON-Resistance, Single Supply, Differential SPST Analog Switches; MSOP8; Temp Range: -40° to 85°C

PT100 Platinum Resistance Thermometer Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
Omron E5CJ-R2

Abstract:
Text: 0 -100 -200 Temperature range Built-in switch Pt100 Platinum resistance thermometer , (K/J/T/L/U/N) or platinum resistance thermometer (JPt100/ Pt100 ), selectable 10 VA (at 24 VAC) 6 W , E53-COV04 Temperature Ranges Temperature-resistance thermometer Input ( ) (switch selectable) JPt100 Platinum resistance thermometer Default setting; 2(K) J (IC) Iron vs. constantan T , 9,999!C/!F (in units of 1!C/!F) Platinum resistance thermometer , thermocouple (T/U): -199.9! to


Original
PDF IP66/NEMA4 H062-E1-5A 0299-2M Omron E5CJ-R2 omron e5cj manual omron e5cj-q2 operation manual omron e5cj-r2 manual E5CJ-Q2HB manual E5CJ-Q2HB E5CJ-R2HB E5CJ-R2 PT100 Platinum Resistance Thermometer omron e5cj operation manual
2009 - Not Available

Abstract:
Text: Inputs) Input Type Platinum resistance thermometer Name Pt100 Thermocouple JPt100 K , Inputs) Input Type Platinum resistance thermometer Name Pt100 Thermocouple JPt100 K , / platinum resistance thermometer L: Analog current/voltage input 5. Power Supply Voltage Blank: 100 to , Alarms 2: Two alarms 3. Input Type T: Thermocouple, infrared sensor/ platinum resistance thermometer , less for K sensors Influence of voltage Platinum resistance thermometer inputs: (See note 2.) (Â


Original
PDF 11-segment 847-843-7900/Fax: 6835-3011/Fax: 21-5037-2222/Fax: H209-E1-03
E5CSV

Abstract:
Text: , L Platinum resistance thermometer input type: Pt100 , JPt100 Universal-input (thermocouple/ platinum , / platinum resistance thermometer ) models also available. · Clearly visible digital display with character , alarm 2: 2 alarms 3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/ platinum , : E5CSV-RKJ-W · Relay control output, one alarm output, platinum resistance thermometer input, black case , Platinum Resistance Thermometer , Power Supply Voltage: 100 to 240 VAC Size Type Control modes 1 Alarms


Original
PDF E53-COV17 E5CSV pt100 temperature controller circuit diagram Block diagram of Automatic Water Level Controller digital thermometer e5cs PT100 Platinum Resistance Thermometer digital thermometer using pt100 E53-COV17 temperature controller e5cs thermocouple temperature sensor for 0 to 400 degree JPT100
PT100 Platinum Resistance Thermometer

Abstract:
Text: input type: Pt100 , JPt100 Multi-input (thermocouple/ platinum resistance thermometer ) type: K, J, L, T , K, J OFF Platinum resistance thermometer Pt100 ON JPt100 OFF Multi-input , / Platinum Resistance Thermometer ) Control mode switch 5: OFF 0 2 K Pt100 -99 to 1500 0 to , , double-throw) Voltage Thermocouple (K, J) Platinum resistance thermometer ( Pt100 , JPt100) Blank 1 2 , Thermocouple (K, J) Platinum resistance thermometer ( Pt100 , JPt100) Multi-input (thermocouple/ platinum


Original
PDF H138-E1-01 75-344-7080/Fax: 0805-1M PT100 Platinum Resistance Thermometer temperature controller circuit diagram with relay jPT100 AUTOMATIC ROOM LIGHT CONTROLLER omron e5cs q1kj Omron E5CSV temperature controller e5cs 0-400 E5CSV 2 pole 6 way rotary switch omron pt100
Y92F-45

Abstract:
Text: Platinum resistance P: thermometer ( Pt100 ) 2 Alarm  Relay output: 250 VAC, 1 A 1: (resistive load , , J, T, R, or S) TC:  Platinum resistance P: thermometer ( Pt100 ) 3 Sensor type  Thermocouple (K, J, T, R, or S) TC:  Platinum resistance P: thermometer ( Pt100 ) 3 Specifications , Thermocouple: K, J, T, R, or S Models with platinum resistance thermometer inputs Platinum resistance thermometer : Pt100 Control output Relay output SPST-NO, 250 VAC, 3 A (resistive load), electrical


Original
PDF NL-2132 Y92F-45
2009 - omron e5cs

Abstract:
Text: resistance thermometer : Pt100 , JPt100 Thermistor: E52-THE@@ Universal-input (thermocouple/ platinum , thermometer G: Thermistor T: Thermocouple/ platinum resistance thermometer (universal-input) 4. Power , : E5CS-RKJU-W · Relay control output, one alarm output, platinum resistance thermometer input, plug-in , : Light Gray, Thermocouple or Platinum Resistance Thermometer , Power Supply Voltage: 100 to 240 VAC Size , Model with thermocouple Model with platinum resistance thermometer Relay 1 E5CS-RKJU-W


Original
PDF
E5CSV

Abstract:
Text: KJ P Thermocouple (K, J) Platinum resistance thermometer ( Pt100 , JPt100) Blank 1 2 No , / platinum resistance thermometer ) models Thermocouple (K, J) Platinum resistance thermometer ( Pt100 , monitoring more effective · Multiple temperature sensor input (thermocouple/ platinum resistance thermometer , alarm 1: 1 alarm 2: 2 alarms 3. Input type T: Thermocouple/ platinum resistance thermometer (multi-input) KJ: Thermocouple P: Platinum resistance thermometer 4. Power supply voltage Blank: 100 to


Original
PDF omron247 H138-E3-02 E5CSV Omron E5CSV fire alarm using 555 omron pid example PT100 temper Omron E5CSV-R1KJ-W omron e5csv-r1t-f 3 wire pt100 sensor wiring diagram e5csx Y92F-30
2010 - Omron E5CSV

Abstract:
Text: , J, L Platinum resistance thermometer input type: Pt100 , JPt100 Universal-input (thermocouple/ platinum resistance thermometer ) type: K, J, L, T, U, N, R, Pt100 , JPt100 Control output SPST-NO , (thermocouple/ platinum resistance thermometer ) models also available. · Clearly visible digital display with , : No alarm 1: 1 alarm 2: 2 alarms 3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/ platinum resistance thermometer (universal-input) 4. Power Supply Voltage Blank


Original
PDF
E5CSZ-R1TD

Abstract:
Text: Pt100 Note: The control range for multi-input (thermocouple/ platinum resistance thermometer ) models , P Thermocouple (K, J) Platinum resistance thermometer ( Pt100 , JPt100) Blank 1 No alarms , alarms Blank: No alarm 1: 1 alarm 3. Input type T: Thermocouple/ platinum resistance thermometer , Power consumption 5 VA Sensor input Multi-input (thermocouple/ platinum resistance thermometer , €¢ Switching is performed between a thermocouple and platinum resistance thermometer for multi-input models. â


Original
PDF H141-E1-01 75-344-7080/Fax: E5CSZ-R1TD
2007 - fire alarm using thermistor

Abstract:
Text: applications requiring alarms. · Multi-input (thermocouple/ platinum resistance thermometer ) models also , thermometer G: Thermistor T: Thermocouple/ platinum resistance thermometer (multi-input) 4. Power Supply , : E5CS-RKJU-W · Relay control output, one alarm output, platinum resistance thermometer input, plug-in , , Thermocouple or Platinum Resistance Thermometer , Power Supply Voltage: 100 to 240 VAC Size E5CS-U 48 × 48 , thermocouple Model with platinum resistance thermometer Relay E5CS-RPU-W E5CS-QKJU-W


Original
PDF
E5GN-Q1TC manual

Abstract:
Text: . of alarm points - Output Thermocouple model Platinum resistance thermometer model , E5GN-Q03TC-FLK E5GN-Q03P-FLK E5GN E5GN Input Ranges Platinum Resistance Thermometer Input/Thermocouple Input Platinum resistance thermometer input Input type Platinum resistance thermometer , resistance thermometer : Pt100 , JPt100 Non-contact temperature sensor: 10 to 70_C, 60 to 120_C, 115 , . (see note ) Platinum resistance thermometer : (±0.5% of indicated value or ±1_C, whichever greater) ±1


Original
PDF
PT100 Platinum Resistance Thermometer

Abstract:
Text: , E, L, U, N, R, S, B 4 VA/2.5 W Platinum resistance thermometer : Pt100 , JPt100 , Platinum resistance thermometer model Note: Relay E5GN-R1TC E5GN-R1P E5GN-Q1TC E5GN-Q1P , -485 S 85 Output Thermocouple model Platinum resistance thermometer model 10 , models. E5GN E5GN Input Ranges Platinum Resistance Thermometer Input/Thermocouple Input Platinum resistance thermometer input Input type Platinum resistance thermometer Temperature


Original
PDF RS485 PT100 Platinum Resistance Thermometer E5GN-Q1TC manual ES1A OMRON pt100 jis JPT100 pt100 sensor JIS C1604 range M type A E5GN-Q1TC k115 C1604-1997 C1604-1989
OMRON E5CN-R2MTC-500

Abstract:
Text: 4 VA/3 W Thermocouple: K, J, T, E, L, U, N, R, S, B Platinum resistance thermometer : Pt100 , Various temperature inputs: thermocouple, platinum resistance thermometer , non-contact temperature sensor , Thermometer Input/Thermocouple Input Platinum resistance thermometer input Input type Platinum resistance , indicated value or ±1_C, whichever greater) ±1 digit max. (see note ) Platinum resistance thermometer , 00 o 0 C No. of alarm points - Output Thermocouple model Platinum resistance


Original
PDF E53-CNHB E53-CNH03 OMRON E5CN-R2MTC-500 E5CN-R2MP-500 manual omron E5CN-Q2MTc-500 E5CN-Q2MTC-500 E5CN-Q2MP-500 omron e5cn E5CN-R2MTC-500 E53-COV10 E5CN-RMP-500 E5CN-QMTC-500
E5C2-R20L-D

Abstract:
Text: thermocouple P: Platinum resistance thermometer ( PT100 ) G: Thermistor (THE) 5. Special type Blank , K (CA) Chromel vs. alumel Platinum resistance thermometer Thermistor (see note 2) Pt100 , Thermocouple K (CA) Chromel vs. alumel L (IC) Iron vs. constantan Platinum resistance thermometer , sensor burnout detection circuit), platinum resistance thermometer , or thermistor Control mode ON , serious accident may result. Platinum resistance thermometer input Relay output If the E5C2 is


Original
PDF PT100) H081-E1-02 E5C2-R20L-D PT100 thermistor E5C2-R40L-D 2pt100 e5c2-r20l PT100 Platinum Resistance Thermometer PT100 thermistor sensor E5C2-R20K thermistor M35 E5C2
rtd pt100 sensor JIS C1604

Abstract:
Text: temperature measurements desired. The nominal resistance of a platinum RTD is 100 at 0°C. Though platinum , 3. Resistance /Temperature Table* for 385 Platinum , 100.0 at 0°C °C 0 1 2 3 4 5 , 2 4 5 7 8 9 200 175.84 *RTD PT100 table showing the relation between resistance , relationship between PT100 resistance and temperature, which is not the case. The exercise above shows that , Keywords: temperature sensor, RTD, platinum Feb 21, 2005 APPLICATION NOTE 3450 Positive Analog


Original
PDF PT100 PT100 com/an3450 MAX197: MAX4236: MAX4237: AN3450, APP3450, Appnote3450, rtd pt100 sensor JIS C1604 pt100/RTD PT100 signal conditioning circuit for pt100 MAX4236 pt100 pt100 TRANSFER FUNCTION pt100 jis current source pt100 PT100 table pt100 sensor interface WITH ADC maxim pt100 interface
E5CSV-Q1T-500

Abstract:
Text: Multi-input (thermocouple/ platinum resistance thermometer ) type: K, J, L, T, U, N, R, Pt100 , JPt100 Control , 3. Input type T: Thermocouple/ platinum resistance thermometer (multi-input) 1. Output type R , Thermocouple input 9.1 Thermocouple/ platinum resistance thermometer multi-input Note: 1. The voltage , 7 1. Sensor Type Specification Multi-input (Thermocouple/ Platinum Resistance Thermometer , Platinum resistance thermometer input ON Thermocouple input OFF Temper- ° F ature °C unit


Original
PDF
maxim pt100 interface

Abstract:
Text: temperature measurements desired. The nominal resistance of a platinum RTD is 100 at 0°C. Though platinum , . Resistance /temperature table* for 385 platinum , 100.0 at 0°C °C 0 1 2 3 4 5 6 7 8 9 -100 60.26 , measured PT100 resistance to the corresponding linearized temperature. On the other hand, the previous , relationship between PT100 resistance and temperature, which is not the case. The exercise above shows that , Keywords: temperature sensor, RTD, platinum Feb 21, 2005 APPLICATION NOTE 3450 Positive analog


Original
PDF PT100 MAX4236 MAX4237 com/an3450 AN3450, APP3450, Appnote3450, maxim pt100 interface DIN 17006 pt100 TRANSFER FUNCTION pt100 sensor interface WITH ADC pt100 maxim signal conditioning circuit for pt100 MAX4236 pt100 pt100 sensor interface WITH ADC for max197 PT100 IEC 751 Resolution current source pt100
E54-CT1

Abstract:
Text: of only 78 mm. · Various temperature inputs: thermocouple, platinum resistance thermometer , : Platinum resistance thermometer Temperature Controller 1. Output type R: Relay Q: Voltage (for , Thermocouple: Platinum resistance thermometer : Infrared temperature sensor: Voltage input: 5 VA/4 W K, J , Thermometer Input/Thermocouple Input Platinum resistance thermometer input Input type Platinum resistance , ) Platinum resistance thermometer : (±0.5% of indicated value or ±1°C, whichever greater) ±1 digit max


Original
PDF E54-CT1 E53-COV11 E54-CT3 E54-CT1 E5AN-Q3HMTC-500 E5AN-R3MTC-500 C1602 E5AN-C3MTC-500 UL3121-1 PT100 Platinum Resistance Thermometer omron ct E54-CT1 E5AN E5AN-Q3HMP-500
omron e5cn

Abstract:
Text: : Thermocouple P: Platinum resistance thermometer 4. Plug-in type U: Plug-in type Ordering Information , Output Thermocouple model Platinum resistance thermometer model E5CN-RTCU E5CN-RPU , Thermocouple: Platinum resistance thermometer : Infrared temperature sensor: Voltage input: Control output , Thermometer Input/Thermocouple Input Platinum resistance thermometer input Input type Platinum resistance , note) Platinum resistance thermometer : (±0.5% of indicated value or ±1°C, whichever greater) ±1 digit


Original
PDF 11-pin) H109-E1-02 75-344-7080/Fax: omron e5cn E5CN-R2T E5cN-QTC E5CN-R1TCU PT100 ma output JIS C1604-1989 e5cn circuit diagram with relay E5CN-R2TC E5CN-U j type thermocouple sensor
2011 - CJ1W-PTS52

Abstract:
Text: Configuration CJ1W-PTS52 Four platinum resistance thermometer inputs ( Pt100 (JIS, IEC), JPt100) 20 , Type Platinum Resistance Thermometer Pt100 JPt100 Temperature range -200 to 200°C 200 to 650°C -200 to , a platinum resistance thermometer , thermocouple, and DC signal (current, voltage). All inputs are , (Isolated-type inputs for each input Resistance Thermometer Input Units) Resistance thermometer : Pt100 , JPt100 , inputs inputs Resistance thermometer : Pt100 , JPt100 Conversion speed: 250 ms/ 4 inputs 0.25 -


Original
PDF CJ1W-PTS/PDC/PH41U/AD04U CJ1W-PH41U CJ1W-AD04U CJ1W-PTS52 CJ1W-AD04U CJ1W-PTS51 CJ1W-PDC15 CJ1W-PTS16 pt50 jis W368 omron f300 pt100 sensor JIS C1604 range M type A
E5CN-R2MP-500

Abstract:
Text: , U, N, R, S, B 4 VA/3 W Platinum resistance thermometer : Pt100 , JPt100 Non-contact , Various temperature inputs: thermocouple, platinum resistance thermometer , non-contact temperature sensor , Platinum resistance thermometer model Relay E5CN-RMTC-500 E5CN-RMP-500 Voltage output (for , Platinum Resistance Thermometer Input/Thermocouple Input Platinum resistance thermometer input Input type Platinum resistance thermometer Temperature range Name 1800 1700 1600 1500 1400 1300 1200


Original
PDF E53-CNB E53-CN03 E53-CNH03 E5CN-R2MP-500 E5CN-R2MTC-500 E5CN-c2Mtc-500 E5CN-C2MP-500 E5CN-Q2MP-500 E5CN-RMTC-500 E5CN-Q2MTC-500 E5Cn E53-CNHB
2009 - D20400

Abstract:
Text: Configuration CJ1W-PTS52 Four platinum resistance thermometer inputs ( Pt100 (JIS, IEC), JPt100) 20 , following example. Item Ambient temperature Details 30°C Platinum Resistance Thermometer Pt100 , be set to a platinum resistance thermometer , thermocouple, and DC signal (current, voltage). All , Accuracy: ±0.3% of PV or ±0.8°C, whichever is larger, ±1 digit max. Resistance thermometer : Pt100 , : Platinum resistance thermometer input: ±0.3% of PV or ±0.8°C, whichever is larger) ±1 digit max


Original
PDF CJ1W-PTS/PDC/PH41U/AD04U CJ1W-PH41U CJ1W-AD04U D20400 CJ1W-PTS52 CJ1W-PTS d2059 power supply circuit diagram omron sysmac c200h pt100 jis CJ1W-PTS51 Ni508.4 CJ1W-PA202 manual pro27 OMRON Operation Manual
E5CN-R2MTC-500

Abstract:
Text: , E, L, U, N, R, S, B 4 VA/3 W Platinum resistance thermometer : Pt100 , JPt100 Non-contact , Various temperature inputs: thermocouple, platinum resistance thermometer , non-contact temperature sensor , Platinum resistance thermometer model Relay E5CN-RMTC-500 E5CN-RMP-500 Voltage output (for , Resistance Thermometer Input/Thermocouple Input Platinum resistance thermometer input Input type Platinum resistance thermometer Temperature range Name 1800 1700 1600 1500 1400 1300 1200


Original
PDF E53-CNB E53-CN03 E53-CNH03 E5CN-R2MTC-500 E5CN-R2MP-500 E5CN-Q2MP-500 E5CN-Q2MTC-500 E5CN-C2MTC-500 E53-CNHB E5CN-RMTC-500 E5CN-C2MP-500 E5CN-CMTC-500
2009 - e5c2-r20g

Abstract:
Text: Platinum resistance thermometer Pt100 Thermistor (replaceable element) 1,200 Themistor nominal , E5C2-R20K Resistance Thermometer Platinum -50 to 50 resistance thermom- -20 to 80 eter Pt100 0 to , circuit), platinum resistance thermometer , or thermistor with replaceable element Insulation , a platinum resistance thermometer to terminals 1 (positive) and 2 (negative) on the E5C2 as shown , 3 4 5 3. Input K: K-type thermocouple J: J-type thermocouple P-D: Platinum resistance


Original
PDF Pt100) e5c2-r20g omron P2CF-08-E PT100 thermistor E5C2-R40P-D E5C2R40P-D thermo couple PT100 E5C2-R40K chromel alumel PT100 omron omron pt100
jPT100

Abstract:
Text: Platinum resistance thermometer : Pt100 , JPt100 Non-contact temperature sensor: 10 to 70_C, 60 to 120 , E5GN J INPUT RANGES Input type Platinum resistance thermometer Name 1800 1700 1600 1500 , : ±0.5% of indicated value or ±1_C, whichever greater, ±1 digit max. (See Note) Platinum resistance , , platinum RTD, non-contact temperature sensor, and analog temperature inputs H Auto-tuning and , Size Power supply voltage Alarm points Output Thermocouple input Platinum RTD input


Original
PDF 1-800-55-OMRON GCTC13 jPT100 E5GN-Q1TC manual pt100 jis rtd pt100 sensor JIS C1604 JIS C1604-1989 E5GN-Q1TC AC100-240 7 segment digital display omron pt100 DIN 43710-1985 C1604-1989
Supplyframe Tracking Pixel