The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LM134H-6 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN
LM134H-3 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN
LTC2997HDCB#PBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 125°C
LTC2997IDCB#TRMPBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: Industrial
LTC2997CDCB#TRMPBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C
LTC2997IDCB#TRPBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: Industrial

PT100 2 wire temperature sensor -200 to 650 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2002 - Not Available

Abstract:
Text: %RH, -30 to 140°C; 4-20mA RH outputs HX48A with 4-20mA RH and 3 wire PT100 RTD Temperature output , HX48A-PT100 outputs a 4-20 mA signal for RH and a 3- wire PT100 RTD signal for temperature . All models in , the environment to be controlled. (Low and high temperature ) Remote Sensor Model: For measurement , ±0.2°C for temperature Probe Dimensions: 72 x 22 mm ( 2 L x 7⁄8" dia.) Power Supply: 9 to 33 Vdc , Tolerance: 30 bar max. Sensor Material: DELRIN Storage Temperature : -40 to 70°C (-40 to 158°F) ABS


Original
PDF HX46A HX46A HX47A/B HX48A HX46A, HX47A/Band HX48A HX48A-PT100 PT100
2007 - PT100 surface temperature sensor

Abstract:
Text: tanks and open channels. Incorporated within the system is a 3- wire Pt100 temperature probe together , design ­ minimizes operational costs Low maintenance, long-life sensor ­ easy to maintain Complete , test. These materials tend to become attached to the sensor and sensor holder giving rise to , assembly is mounted into a support tube which also houses a temperature sensor for automatic temperature , spherical flotation collar is secured around the support tube to provide buoyancy, allowing the sensor to


Original
PDF SS/9408 SS/9408 PT100 surface temperature sensor 0233-828 PT100 ABB datasheet dissolved oxygen sensor ABB Pt100 Probe temperature sensor using arm PT100 temperature sensor ABB water level SENSOR WITH PT100 liquid solvent cement ABB Pt100 3 wire
2014 - PT100 temperature sensor

Abstract:
Text: , D21.09 Resistance, ceramic terminal Analogue, built in transmitter Pt100 signal, 2 , 3 or 4 wire , temperature sensor Electrical connections Electrical connections M12, 5 fils M12, 5- wire M12, 8 , CombiTemp TFR5 TM Room or outdoor temperature sensor Main features „„ Sensor in , steel, AISI 316L (1.4404) High flexible silicone, grey Sensor element, Pt100 - DIN/EN/IEC 60751 , 2-wire or 4- wire Measuring range -200.850°C Accuracy ±0.3°C Power supply 1 Ã


Original
PDF Pt100 Pt100 PT100 temperature sensor PT100 temperature sensor data sheet PT100 class A pt100 temperature sensor transmitter 4-20 ma
2007 - PT100 temperature sensor data sheet

Abstract:
Text: FlexTemp 2301 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2 -, 3- or 4- wire , Electrical Installation RTD Pt100 Pt100 Pt100 3 7 3 7 3 7 4 8 2-wire sensor 4 , compensation ( 2-wire ) Sensor error detection 2 -way configuration (Windows) Configurable damping and status , loop-powered transmitter for Pt100 sensors. Either 2 -, 3- or 4- wire sensors can be used. For 2-wire sensors , °C: < 0.25°C { 2 } 0.25% of span Storage temperature -55.90°C Humidity < 90% RH (IEC 68-2-38


Original
PDF Pt100 Pt100 UK/2007-03-14 PT100 temperature sensor data sheet PT100 temperature sensor
1998 - PT100 4 wire temperature sensor

Abstract:
Text: fibre-optic bus Connections Plug-in for PT100 sensor ( 2-wire , 4- wire ) Data port II/O system , 2 byte, ( x 10) Converter range temperature -50 to +150 degrees C 0 to +512 degrees C in , Date : 12 March 97 PT100 4-fold temperature measurement @ Ã 9 @ G Ã 2 Ã 9 , Constant-current source for PT100 sensor (1mA) A bridge has to be inserted at the input for all of the unused , PT100 4-fold temperature measurement Beckhoff II/O System PT100 4-fold temperature


Original
PDF PT100 D-33415 PT100 4 wire temperature sensor PT100 connected diagram PT100 2 wire temperature sensor PT100 SENSOR PT100 3 wire temperature sensor PT100 bridge example PT100 temperature sensor resolution PT100 3 wire connected diagram PT100 bridge 3 wire pt100 sensor wiring diagram
2008 - PT100 temperature sensor data sheet

Abstract:
Text: Cable Sensor , Pt100 /Pt1000 Sensors with 4- wire silicone cable for pockets or tubes 4- wire air , Application 230 Vac Pt100 /Pt1000 sensor 5 3 7 3 4 5 1 2 1 2 4 3 6 2 - + 1 , temperature sensor . Changes in temperature are reflected by changes in the electrical resistance, so that measuring the value of the resistance gives an analogue expression for the actual temperature . The Pt100 , the nominal working range. The Pt100 sensor fits as an insert in sensor tubes with an internal


Original
PDF Pt100/Pt1000 Pt100 UK/2008-06-02 PT100 temperature sensor data sheet PT100 temperature sensor 811A tube PT100 temperature sensor 3 wires pt1000 class B, DIN EN 60751 PT1000 Sensor Data PT1000 temperature sensor
gefran pt100

Abstract:
Text: : 0 . 100 %rh, -20 .+80 °C · Accuracy: ± 2 %rh, ± 0, 2 °C · Output signal: 0 . 1V (3 wire ), Pt100 1/3 DIN · Supply voltage: 5.32VDC · Housing protection: IP65 · Interchangeable sensor module , connections 3 wire Hysteresis / non-linearity included ± 2 %rh (5 . 95 %rh) ± 2 ,5 %rh (< 5 %rh, > 95 %rh) 0 . 100 %rh (90% of scale for a step change from 11% to 75 %rh) < 10 sec 0 . 1V Pt100 , Pt100 1/3 DIN (3 wire ) 5.32 VDC > 10K Output voltage: > 10K 2mA humidity only version with


Original
PDF Pt100 32VDC S6000 S6000, S6000: S6000 6A03130 gefran pt100 PT100 2 wire temperature sensor PT100 4 wire temperature sensor PT100 PT100 3 wire temperature sensor pt100 measurement PT100 temperature sensor water sensor PT100 pt100 datasheet Pt100 3 wire
RH 11 C1

Abstract:
Text: °C Measuring range Sensor response time Temperature 4- wire 4- wire Hysteresis and non-linearity included ± 2 %RH (5.95%RH) ± 2 ,5%RH (< 5%RH, > 95%RH) 0.100%RH (90% of the range from 11% to 75%RH) Pt100 1/3DIN direct: ±0, 2 °C Current output: ±0,4°C Voltage output: ±0,3°C -30.+85°C , 2 Range -30.+70°C with C1 closed 1 Range 0.100°C Voltage output 0 Pt100 , humidity (0.100%RH) and Pt100 direct for temperature , 24Vac/dc power supply, 2m connecting cable, 123mm


Original
PDF 10Vdc; 10Vdc 20Vdc; Pt100 24Vac/dc S6000 S6000: S6000 RH 11 C1 pin configuration PT100 temperature sensor gefran pt100 6A03130 PT100 S2 temperature transmitter pt100 4-20ma PT100 temperature sensor data sheet humidity sensor data TRASMITTER SENSOR
2004 - PT100 omron SENSOR

Abstract:
Text: . Default (ex-factory) setting is all switches ON, i.e. all 6 inputs are active and set to Pt100 sensor , Sensor error, broken wire or short circuit Measured value out of range (over max. Temperature ) Measured , the leadwire impedances will be the same. 2-wire connection can be used by shorting B-B’, but the , the PLC. In case of shielded sensor wiring, connect the shields to the same grounding point as the , specifications. See Operation Manual W393. ■Characteristics Temperature Sensor Number of inputs


Original
PDF CJ1W-TS562 CJ1W-TS562 Pt100 Pt1000 NL-2132 634292-5A PT100 omron SENSOR
2013 - Not Available

Abstract:
Text: FlexTop 2202 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2 -, 3- or 4- wire , compensation ( 2-wire ) Sensor error detection 2 -way configuration Configurable damping and status indication , . Either 2 -, 3- or 4- wire sensors can be used. For 2-wire sensors an automatic balancing of the sensor , °C: Span > 250°C: < 0.25°C { 2 } 0.1% of span Storage temperature -55.90°C Humidity < 98 , 0.3 mA, continuously Sensor type 2 -, 3- or 4-wires {1} Sensor short detection < -225°C


Original
PDF Pt100
gefran T220

Abstract:
Text: range: 0 . 98 %rh, -30 . +70 °C · Accuracy: ± 2 %rh, ± 0, 2 °C · Output signal: 4 . 20mA ( 2 wire ), 0 . 1V, 0 . 5V, 0 . 10V, 0 . 20mA (3 wire ), Pt100 1/3 DIN · Supply voltage: 8.33VDC · Interchangeable sensor module S6000 · Linearised and temperature compensated humidity measurement · Capacitive , Connections Accuracy @ 23 °C Temperature gradient Measuring range Sensor response time Temperature 2 or 3 wire 2 or 3 wire Hysteresis non-linearity included ± 2 %rh (5.95 %rh) ± 2 ,5 %rh


Original
PDF Pt100 33VDC S6000 S6000, 1A04640, 4/20mA, 4/20mA gefran T220 PT100 4 wire temperature sensor transmicor T220 T2202 T2201 gefran pt100 pt100 temperature 3 wire Pt100 transmitter 4...20 mA sensor PT100 PT100 2 wire temperature sensor
Not Available

Abstract:
Text: FlexTop 2202 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2 -, 3- or 4- wire , compensation ( 2-wire ) Sensor error detection 2 -way configuration Configurable damping and status , transmitter for Pt100 sensors. The Flex-Program has a datalogging facility enabling the user to monitor measuring results or calibrate the measuring setup. Either 2 -, 3- or 4- wire sensors can be used. For 2-wire , temperature -40.85°C Span < 250°C: Span > 250°C: < 0.25°C { 2 } 0.1% of span Storage


Original
PDF Pt100
gefran pt100

Abstract:
Text: Sensor response time Temperature 4- wire 4- wire Hysteresis and non-linearity included ± 2 %RH (5.95%RH) ± 2 ,5%RH (< 5%RH, > 95%RH) 0.100%RH (90% of the range from 11% to 75%RH) Pt100 , temperature 0 Pt100 direct (Standard) 1 Voltage output Range 0.100°C 2 with C1 closed , Linearised and temperature compensated humidity measurement · Capacity thin film humidity sensor · , Pt100 direct 1/3DIN (3- wire ) 132 Consumption Operating range Probe Housing Storage Housing


Original
PDF 10Vdc; 10Vdc Pt100 24Vac/dc S6000 10Vdc, 10Vdc 24Vac/dc gefran pt100 pin configuration PT100 temperature sensor PT100 2 wire temperature sensor PT100 connected principle temperature transmitter pt100 4-20ma PT100 S2 pt100 LR pt10 Humidity and Temperature Probe
t251

Abstract:
Text: Electrical connections Temperature 4- wire 4- wire Hysteresis and non-linearity included ± 2 %RH (5.95%RH) ± 2 ,5%RH (< 5%RH, > 95%RH) 0.100%RH (90% of scale for a step change from 11% to 75%RH) Pt100 1/3DIN Direct: ±0, 2 °C Current output: ±0,4°C Voltage output: ±0,3°C < 10 sec 4.20mA, 0.10Vdc, 2.10Vdc, 0.1Vdc -30.+70°C / Pt100 direct 1/3DIN (3- wire ) / -30.+70°C , and temperature compensated humidity measurement · Capacity thin film humidity sensor · Response


Original
PDF 10Vdc; 10Vdc Pt100 24Vac/dc S6000 S6000 6A03130 t251 pin configuration PT100 temperature sensor 0-10VDC Gefran 40 gefran pt100 10VDC pt100 4 wire measurement pt100 sensor thin film PT100 temperature sensor data sheet
gefran 230

Abstract:
Text: 32 Temperature range Power supply: E Impedence: R Pt100 1/3 DIN direct: ± 0, 2 °C Current , range Sensor response time 4 wire ø 22 Accuracy @ 23 °C Temperature 4 wire ø22 , : 4 . 20mA, 0 . 20mA, 2 . 10V, 0 . 10V (selectable with jumper), Pt100 1/3 DIN · Power , and temperature compensated humidity measurement · Capacitive thin film humidity sensor · Sensor , . TECHNICAL DATA DIMENSIONS 50 Pt100 direct 1/3 DIN (3 wire ) 0/4.20mA, 0/2.10V / -30.+70


Original
PDF Pt100 230VAC S6000 S6000, 6A03130 S6000 6A08840 gefran 230 din pn10 PT100 temperature gefran pt100 PT-100 temperature sensor gefran 500 gefran 40 gefran 230-sw 4 wire pt100 temperature sensor 2-10v temperature transmitter pt100 4-20ma
2001 - PT100 IEC 751

Abstract:
Text: temperature measuring transducers convert the measured values of the PT100 sensor (IEC rigid751/EN 60751 , increase the process safety, the modules are equipped with 3-way isolation. 2 -, 3-, and 4- wire PT100 , internal buttons. DIP switches can be used to set: · The connection method ( 2 -, 3-, and 4- wire sensors). , Temperature Measuring Transducer for PT100 ­ MCR-SL-PT100-.-DC-24 2 . Technical Data OUT 1 2 D , MCR-SL-PT100-U-DC-24 MCR-SL-PT100-I-DC-24 Input Temperature range span PT100 (IEC 751/EN 60 751): 2 -, 3


Original
PDF PT100 MCR-SL-PT100-. -DC-24 MCR-SL-PT100 PT100 rigid751/EN PT100 IEC 751 MCR-SL-PT100-I-DC-24 phoenix DIP switch settings MCR-SL-PT100 DC 24 MCR-SL-PT100-U-DC-24 pt 100 sensor PT-100 sensor pt100 temperature transducers PT100 type B iec 60751
temperature PT100

Abstract:
Text: HTY7033 Ceiling Mounted Sensor uses a Pt100 platinum film temperature sensing element and a polymer , Z 1 0 0 P P P 00 00 01 Humidity (1-5 V) + Temperature ( Pt100 ) Lead wire output Temperature ( Pt100 ) Lead wire output Temperature ( Pt100 ) Modular jack output 1 Specifications Item , TY7033Z0P00 White Pt100 White Black wire of power supply and humidity output is wired inside sensor , to . 1 (A) 2 (B) 3 (A) 4 (B) 5 NC Pt100 6 (B) 7 NC 8 (B) TY7033Z0P01 Wiring and color


Original
PDF AB-5965 HTY7033/ TY7033 HTY7033 Pt100 TY7033 AB-5965 temperature PT100 Yamatake pt100 PT100 double PT100 temperature sensor long sensing element TY7033Z0P00 Pt100 3 wire yamatake HTY7033T1P00 fp3 matsushita sensor PT100 PT100 temperature sensor data sheet
2007 - V10681

Abstract:
Text: Sheath in Stainless Steel 2 x Pt100 , 2-wire Sensor with Sheath in Stainless Steel 2 x Pt100 , 3- wire , Sheath in Stainless Steel 2 x Pt100 , 2-wire Sensor with Sheath in Stainless Steel 2 x Pt100 , 3- wire , Industry Temperature Sensor for Arduous Environments ­ Ex certified including Ex d according to ATEX , Temperature Sensor for Arduous Environments ­ Ex certified including Ex d according to ATEX SS/HDA , , U B, C, D, E, J, ,K L, N, R, S, T ,U Input ( Sensor Type) RTD type ( 2 -, 3- and 4- wire )/ min


Original
PDF
gefran 230

Abstract:
Text: · Output signal: 4 . 20mA, 0 . 20mA, 2 . 10V 0 . 10V (selectable with jumper), Pt100 1/3 , downtime is minimised. TECHNICAL DATA DIMENSIONS Humidity Temperature 4 wire 4 wire , ) Measuring range Sensor response time 0 . 100 %rh (90% of scale for a step change from 11% to 75 %rh) Pt100 1/3 DIN direct: ± 0, 2 °C Current output: ±0,4 °C Voltage output: ± 0,3 °C -30 . , degree Electrical connections Pt100 direct 1/3 DIN (3 wire ) 0/4.20mA, 0/2.10V / -30.+70


Original
PDF Pt100 230VAC S6000 S6000, 1A04640, 133XA Pt100 24VAC, gefran 230 gefran pt100 pt100 datasheet temperature transmitter pt100 2-10v PT100 temperature sensor PT100 pt 100 sensor technical data PT100 4 wire temperature sensor Pt100 transmitter 4...20 mA pt100 sensor thin film
gefran 230

Abstract:
Text: /10V, 2 /10V (0/100 %rh), temperature output Pt100 direct, power supply 24 VAC, slotted cap in white , · Output signal: 4 . 20mA, 0 . 20mA, 2 . 10V 0 . 10V (selectable with jumper), Pt100 1/3 , downtime is minimised. TECHNICAL DATA DIMENSIONS Humidity Temperature 4 wire 4 wire , ) Measuring range Sensor response time 0 . 100 %rh (90% of scale for a step change from 11% to 75 %rh) Pt100 1/3 DIN direct: ± 0, 2 °C Current output: ±0,4 °C Voltage output: ± 0,3 °C -30 .


Original
PDF Pt100 230VAC S6000 S6000, 1A04640, 11EXE 4/20mA, 0/20mA, 0/10V, 2/10V gefran 230 gefran pt100 PT100 temperature "Humidity Sensor" Pt100 transmitter 4...20 mA pt100 thin film PT100 temperature sensor data sheet pt100 sensor thin film pt100 measurement PT-100 temperature sensor
gefran 230

Abstract:
Text: , 0 . 20mA, 0 . 10V, 2 . 10V (selectable with jumper), Pt100 1/3 DIN · Power supply: 24, 115, 230VAC · Protection degree: IP65 · Interchangeable sensor module S6000 · Linearised and temperature , . TECHNICAL DATA DIMENSIONS Humidity Temperature 4 wire 4 wire Accuracy @ 23 °C Hysteresis non-linearity included ± 2 %rh (5.95 %rh) ± 2 ,5 %rh (< 5 %rh, > 95 %rh) Measuring range Sensor response time 0 . 100 %rh (90% of scale for a step change from 11% to 75 %rh) Pt100 1/3 DIN direct


Original
PDF Pt100 230VAC S6000 S6000, 1A04640, 31XXA 4/20mA, 0/20mA, 0/10V, 2/10V gefran 230 T241 gefran pt100 PT100 temperature sensor PT100 temperature gefran 250 pt100 0-10V transmicor PT100 SENSOR pt100 sensor thin film
2013 - Not Available

Abstract:
Text: Temperature sensor Pt100 , 2-wire (DIN/EN/IEC 60751) Battery: Energizer Lithium FR6 L91 AA , Pt100 sensor Measuring range -200.850°C Ambient temperature -10.70°C Accuracy 0.3°C Battery , connection Pt100 sensor www.baumerprocess.com Design and specifications subject to change without notice , status Battery clip Terminals for Pt100 sensor + Control buttons Note: A Lithium battery , Battery operated digital thermometer 3A/DN38 hygienic, Pt100 sensor 1/6 DIN B Sensor , fast response, 3A


Original
PDF Pt100 EN/2013-03-03
TR800

Abstract:
Text: process signals, including J, K, and Pt100 inputs. Each transmitter offers 2 to 3- wire compensation and , SPAN RTD: 20°C (36°F) min, 500°C (900°F) max TC: 10mV min span * 0+50 INPUT RTD: Pt-100 , 2 , 2 3 4 5 2 3 4 5 +V -V - + - Connect the negative supply lead to terminal two. For Pt-100 RTD Inputs, connect the Pt-100 leads to input terminals 4, 5, and 6 according to , SENSOR RANGE (MV or Temperature ) F ex. 0 - 300 Indicates Span Range (Limited Available


Original
PDF TR800 Pt-100 TR800 4-20mA) 4-20mA RTD PT100 3wire rtd pt100 4-20ma wiring diagram RTD PT-100 PT-100 RTD 3 wire rtd pt100 sensor 3 wire pt100 sensor wiring diagram PT-100 wiring diagram PT100 temperature sensor 0-400 PT-100 RTD 3 wire transmitter
"Air Flow Sensor"

Abstract:
Text: temperature Superwide operating temperature range (up to + 650 °C) Minimum size ( 2 mm x 3 mm) and quick , temperature indicated at °C that is not related to marking ± (absolute value of a temperature ). (* 2 ) T.C.R , STRUCTURE 1 2 3 4 5 6 Protective coating Lead weld reinforcing coating Lead wire Welding point , products are available to meet the customers request Ideal for use as air flow sensor for automobile ( Pt100 level, 1 k, JIS B class) in temperature control units, or as temperature compensation/detection


Original
PDF SDT310 SDT310LT) D-25578 "Air Flow Sensor" 310A tube 310N PT100 2 wire temperature sensor -200 to 650
gefran

Abstract:
Text: : analogue and digital - Temperature : Pt100 1/3 DIN · Capacitive thin film humidity sensor · Sensor , range Sensor response time 3 wire Hysteresis and non-linearity included Pt100 1/3 DIN ± 1,5 , temperature 0 Pt100 direct (standard) 1 GEFRAN spa reserves the right to make any kind of design , S6000 INTERCHANGEABLE SENSOR MODULE FOR RELATIVE HUMIDITY Main characteristics · Interchangeable without recalibration · Linearised and temperature compensated humidity measurement · Operating


Original
PDF S6000 Pt100 S6000 1A01210 6A06350 6A05130 Pt100 gefran gefran pt100 PT100 temperature 6A06350 PPO NORYL "Humidity Sensor" pt100 datasheet pt100 thin film PT100 temperature sensor data sheet PT100 in head