The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
ISL97632IRT14Z-TK Intersil Corporation LED Driver with 1-Wire Dimming; DFN8; Temp Range: -40° to 85°C
EP1000 ABB Critical Power Single Phase, Hot-Pluggable, Fan Cooled SPS Rectifier
X9241AMSIZ Intersil Corporation Quad Digital Controlled Potentiometers (XDCP™), Non-Volatile/Low Power/2-Wire/64 Taps; SOIC20, TSSOP20; Temp Range: See Datasheet
X9241AUVIZT1 Intersil Corporation Quad Digital Controlled Potentiometers (XDCP™), Non-Volatile/Low Power/2-Wire/64 Taps; SOIC20, TSSOP20; Temp Range: See Datasheet
X9259UV24IZ-2.7T1 Intersil Corporation Single Supply/Low Power/256-Tap/2-Wire Bus Quad Digitally-Controlled (XDCP™) Potentiometers; TSSOP24; Temp Range: See Datasheet
X9409WV24Z Intersil Corporation Low Noise/Low Power/2-Wire Bus Quad Digitally Controlled Potentiometers (XDCP™); SOIC24, TSSOP24; Temp Range: See Datasheet

PT-1000 RTD 3 wire Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2006 - rtd 2660

Abstract: S5-FB250 pt100 temperature sensor schematic pt100 schematic PT100 temperature sensor resolution pt1000 temperature sensor schematic RTD PT1000 conversion pt100 temperature schematic NI-100 RTD DIN Ni1000 schematic
Text: , Ni 120, Ni 1000 , resistance measuring. Sensor connection 3-wire (factory preset) or 2- wire , Ni 100/ RTD Ni 1000 / RTD Channels 2 2 2 2 2 Measuring range -200 °C . , Module for RTDs 2- or 3-wire connection 2.1.2.1 View 13 14 Function AI 1 Error AI 1 A C B , -Channel Analog Input Module, Pt 1000 Measuring range: -200 °C . +850 °C 750-461/000-006 2 AI PT100/ RTD , °C 750-461/000-005 2 AI Ni 1000 / RTD 2-Channel Analog Input Module, Ni 1000 Measuring range


Original
PDF D-32423 0x0514 0x8001 20kOhm] D-32385 rtd 2660 S5-FB250 pt100 temperature sensor schematic pt100 schematic PT100 temperature sensor resolution pt1000 temperature sensor schematic RTD PT1000 conversion pt100 temperature schematic NI-100 RTD DIN Ni1000 schematic
2001 - 81-110 thermistor

Abstract: Cu50 measurement Cu53 rtd PT-100 385 4wire temperature sensor Landis Ni 1000 CU53 kty PT-100 THERMISTOR kty Cu50 RTD KTY81-110
Text: application. Connection of sensors in 2-, 3 - and 4- wire technology 5755B 1 IB IL TEMP 2 RTD , sensor can only be connected to channel 1 using 4- wire technology. 5755B 3 IB IL TEMP 2 RTD , on the measurement. 24 5755B IB IL TEMP 2 RTD 3-Wire Technology 2- Wire Technology D , Meaning Green Bus diagnostics R T D Pin Assignment for 2- and 3-Wire Termination Terminal , Sensor connections in 2- and 3-wire technology with shield connection Figure 6 Sensor connections


Original
PDF 5755B KTY81 KTY84 16-bterminal 81-110 thermistor Cu50 measurement Cu53 rtd PT-100 385 4wire temperature sensor Landis Ni 1000 CU53 kty PT-100 THERMISTOR kty Cu50 RTD KTY81-110
of rtd sensor

Abstract: balco 500 balco PT1000 RTD Pt1000 RTD Sensor rtd pt100 -50 to 200 rtd sensor PT 10 rtd rtd pt100 sensor PT-1000 RTD 3 wire
Text: °C IEC RTD 100 Ohms = 0.00385 JIS RTD 100 Ohms = 0.00392 Pt 1000 RTD Pt -40 to 160°C Balco 500 RTD , Sampling Rate: 10 samples / sec. Input Impedance: 10K Input Connections: 2 or 3 wire Accuracy: ± , Model ADAM-6015 Multi-Monitor Up to 7 RTD Sensor Types 7-Channel RTD Input Module Overview The ADAM-6015 7-channel RTD input module accepts a wide range of RTD sensor types, including Pt100, Pt1000 , operators when the sensor wire has been broken. It specifically aims at building and factory temperature


Original
PDF ADAM-6015 ADAM-6015 Pt100, Pt1000, Ni508, 100cal: of rtd sensor balco 500 balco PT1000 RTD Pt1000 RTD Sensor rtd pt100 -50 to 200 rtd sensor PT 10 rtd rtd pt100 sensor PT-1000 RTD 3 wire
Not Available

Abstract: No abstract text available
Text: 200°C IEC RTD 100 Ohms = 0.00385 JIS RTD 100 Ohms = 0.00392 Pt 1000 RTD Pt -40 to 160°C Balco , : 2000VDC Sampling Rate: 10 samples / sec. Input Impedance: 10K Input Connections: 2 or 3 wire , ADAM-6015 - 0704 - 1/2 Model ADAM-6015 Multi-Monitor Up to 7 RTD Sensor Types 7-Channel RTD Input Module Overview The ADAM-6015 7-channel RTD input module accepts a wide range of RTD sensor , diagnostic function which warns operators when the sensor wire has been broken. It specifically aims at


Original
PDF ADAM-6015 ADAM-6015 Pt100, Pt1000, Ni508, 100/100ase:
2006 - PT-100 385 4wire

Abstract: PT-100 385 3wire RTD PT100 3wire rtd 1186
Text: (385) Resistance 0.0 Ω to 400.0 Ω 0.1 Ω (4- wire ) 0.15 Ω (2- and 3-wire ) Resolution 0.1 °C J 0.7 °C 401 Ω to 1500 Ω 0.5 Ω (4- wire ) 1 Ω (2- and 3-wire ) K 0.8 °C T 0.8 °C 1500 Ω to 3200 Ω 1 Ω (4- wire ) 1.5 Ω (2- and 3-wire ) E 0.7 °C R , seven RTD types, plus volts and ohms. The 724 even handles high-speed pulsed RTD circuits and provides , - 10.00 mV to 75.00 mV Measure accuracy 0.025 % + 1 count (via TC connector) NI-120 0.2 ºC


Original
PDF ITS-90 PTS-68 36-FLUKE PT-100 385 4wire PT-100 385 3wire RTD PT100 3wire rtd 1186
2003 - 1762-IR4

Abstract: micrologix 1400 error codes 1762-RM001 micrologix 1100 error codes basic plc ladder diagram 1762-ir4 500 platinum Hot wire Micrologix 1400 terminal wiring diagram RSLOGIX 500 RSLOGIX 500 LADDER Micrologix 1400
Text: devices. Each channel is individually configurable via software for 2- or 3-wire RTD or direct resistance , module accepts input from RTDs with up to 3 wires. If your application requires a 4- wire RTD , one of the two lead compensation wires is not used, and the RTD is treated like a 3-wire sensor. The third , four 3-wire inputs for any combination of RTD and resistance input devices. Channels are wired as , · 3-wire RTD , which is composed of a Sense and 2 RTD lead wires ( RTD EXC and RTN) · 4- wire RTD


Original
PDF 1762-IR4) 1762-UM003A-EN-P 1762-IR4 micrologix 1400 error codes 1762-RM001 micrologix 1100 error codes basic plc ladder diagram 1762-ir4 500 platinum Hot wire Micrologix 1400 terminal wiring diagram RSLOGIX 500 RSLOGIX 500 LADDER Micrologix 1400
NTC 20K

Abstract: Pt 100 sensor connection Pt 1000 sensor connection PT-1000 RTD 3 wire pt 250 temperature sensor pt 100 sensor technical data PT-100 RTD PT-100 RTD 3 wire NI-100 RTD DIN Ni 120
Text: for Pt 200, Pt 500, Pt 1000 , Ni 100, Ni 120, Ni 1000 , resistance measuring 3-wire connection , software. Description Item no. Pack. unit 1) 2AI Pt 100/ RTD 2AI Pt 1000 / RTD 2AI Pt 100/ RTD S5 2) 2AI Pt 100/free configurable 2AI Ni 100/ RTD 2AI Ni 1000 TK6180/ RTD 2AI Ni 1000 TK5000/ RT , A C B Function AI 2 Error AI 2 D +R1 +R2 Data contacts 1 3 -conductor +R 1 , Logic Error Function 3 7 -R 1 -R 2 -R 1 -R -R 2 10 nF S 4 Shield


Original
PDF D-32385 D-32423 NTC 20K Pt 100 sensor connection Pt 1000 sensor connection PT-1000 RTD 3 wire pt 250 temperature sensor pt 100 sensor technical data PT-100 RTD PT-100 RTD 3 wire NI-100 RTD DIN Ni 120
2002 - pt100 rtd rosemount

Abstract: pt 100 temperature sensor RTD abb PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd rosemount PT-1000 sensor PT-100 RTD 3 wire sensor - rosemount PT-100 RTD 3 wire sensor rosemount PT100 rosemount PT-100 RTD 4 wire sensor rosemount th102
Text: short-circuit < 5 (for RTD ) Output Sensor break (temperature/resistance measurement 2, 3 , 4 wire , Resistance thermometer (2, 3 , 4 wire circuit) ­ Thermocouples ­ Resistance remote signalling unit (0.5000 , ) 4.20 mA Sensor wire break monitoring in accordance with NAMUR NE 89 Sensor wire break detection 3 , necessary) Maximum line resistance (Rw) per core 2, 3 , 4 wire 7.5 , 10 , 50 Measuring current 300 µA , °C 40 °C ( 65 °F) ( 72 °F) IEC 751; JIS; SAMA1) 2, 3 and 4 wire Resistance thermometer Pt


Original
PDF TH102/TH102-Ex pt100 rtd rosemount pt 100 temperature sensor RTD abb PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd rosemount PT-1000 sensor PT-100 RTD 3 wire sensor - rosemount PT-100 RTD 3 wire sensor rosemount PT100 rosemount PT-100 RTD 4 wire sensor rosemount th102
balco 3K

Abstract: ADAM-4015
Text: , Balco and Ni RTD RTD Types and Temperature Ranges Pt100 RTD : Pt -50° C to 150° C Pt 0° C to 100° C Pt 0° C to 200° C Pt 0° C to 400° C Pt -200° C to 200° C IEC RTD 100 ohms (a = 0.00385) JIS RTD 100 ohms (a = 0.00392) Pt 1000 RTD Pt -40° C to 160° C Balco 500 RTD -30° C to , 2 or 3 wire Accuracy ± 0.05 % or better Zero Drift ± 3 µV/° C Span Drift ± 25 ppm/° C , ADAM-4015 ADAM-4015T ADAM-4016 6-channel RTD Module with Modbus 6-channel Thermistor Module


Original
PDF ADAM-4015 ADAM-4015T ADAM-4016 16-bit Pt100 balco 3K ADAM-4015
2007 - 1746-NR4

Abstract: RC21-4-1966 belden 9533 1746-N2 1747-RM001 3 wire RTD temperature RTD 4 wire scale code example Pt385 1746-A2 Allen-Bradley 1746-NR4
Text: ( RTD and Return) · 3-wire RTD , which is composed of a Sense and 2 RTD lead wires ( RTD and Return) · , Return Belden #9501 Shielded Cable 3-Wire RTD Interconnection Cable Shield Shield RTD RTD , to the RTD module as a 2- wire interconnection or a 3-wire interconnection as shown on the following , . Publication 1746-IN012B-EN-P - May 2001 SLC 500TM RTD /Resistance Input Module 13 3-Wire , 3 Overview The RTD module receives and stores digitally converted analog data from RTDs or


Original
PDF 500TM 1746-NR4) 1747-RM001 1746-IN012B-EN-P 1746-NR4 RC21-4-1966 belden 9533 1746-N2 1747-RM001 3 wire RTD temperature RTD 4 wire scale code example Pt385 1746-A2 Allen-Bradley 1746-NR4
Cu53 rtd

Abstract: MTL5575 Cu50 RTD MTL4575 cu53 PCL45USB thermocouple sensor cu53 NI-100 RTD DIN CU 53 Pt 100 RTD
Text: socket THC or RTD input + Alarm 6 5 4 4- wire 3-wire The MTLx575 converts a low-level dc , 1000 Pt & Ni sensors) Input signal span 3 to 150mV, or 10 to 400 (10 to 1000 Pt & Ni sensors) RTD , , E, R, S, B or N to BS 60584 and XK mV input RTDs 2/ 3 /4- wire platinum to BS 60751 Pt 100, Pt 500 , , or off Safe area socket 6 5 4 4- wire 3-wire mV mV + 3 2 1 Alarm 7 8 , tagging for all thermocouple types and 2-, 3or 4- wire RTDs. (For thermocouple applications the HAZ-CJC


Original
PDF MTL4575 MTL5575 MTLx575 4/20mA PCS45 PCL45USB EPSx575 Cu53 rtd MTL5575 Cu50 RTD MTL4575 cu53 thermocouple sensor cu53 NI-100 RTD DIN CU 53 Pt 100 RTD
2006 - EMERSON PT 100 RESISTANCE THERMOMETER

Abstract: Pt 100 RTD Siemens Siemens PT100 temperature sensor RTD tmt 112 Wiring Diagram pt-100 siemens DXR275 Siemens PT100 temperature sensor din iec 60751 Pt 100 RTD wiring Siemens PT-1000 RTD 3 wire RTD PT-100
Text: Resistance thermometers Pt 100, Pt 500, Pt 1000 and Ni 100, Ni 500, Ni 1000 in 2, 3 or 4- wire technology , Tools required for periodic checks: ­ Amp meter ­ Wire jumper (only for RTD ) Test Steps 1. 2. 3 , with the following default configuration: Pt 100 sensor, measuring range 0°C . +100°C, 3-wire , ) Measuring Range Limits -60°C . +150°C 10 K According to DIN 43760 Connection method: 2, 3 or 4- wire , ) With 3 and 4- wire termination, sensor cable resistance up to a maximum of 11 per cable Sensor


Original
PDF
2000 - 1746-NR8

Abstract: 1747ASB fault codes 1746-UM003 1746-NR8 wiring manual belden 9533 RC21-4-1966 4 tinned copper wire 1747-NM009 NEC 05F specification 1747-ASB
Text: SLC Processor Each individual channel on the RTD module can receive input signals from 2, 3 or 4- wire , : · 2- wire RTD , which is composed of 2 RTD lead wires ( RTD and Return) · 3-wire RTD , which is , #9501 Shielded Cable RTD 0 Sense 0 Return 0 RTD 1 Sense 1 Return 1 RTD 2 Sense 2 Return2 3-Wire , Repeatability . . . . . . . A- 3 RTD Accuracy and Temperature Drift Specifications . . . . . . . . . . . A , temperature-sensing element connected by 2, 3 , or 4 wires that provide input to the RTD module. The module supports


Original
PDF 500TM 1746-NR8) 1746-UM003A-EN-P 1746-UM003A-EN-P 1746-NR8 1747ASB fault codes 1746-UM003 1746-NR8 wiring manual belden 9533 RC21-4-1966 4 tinned copper wire 1747-NM009 NEC 05F specification 1747-ASB
1966 - 1769-IR6

Abstract: 1769-UM005A-EN-P belden 9533 1769-ECR micrologix 1500 manual PT3916 1769-IA16 1769-ADN 1769-ECR 1769-UM005 1769-RTBN18
Text: . Each channel is individually configurable via software for 2or 3-wire RTD or direct resistance input , module accepts input from RTDs with up to 3 wires. If your application requires a 4- wire RTD , one of the two lead compensation wires is not used, and the RTD is treated like a 3-wire sensor. The third wire provides lead wire compensation. See Chapter 3 , Installation and Wiring, for more information. 1 , removable terminal block (spare part number 1769-RTBN18) providing connections for six 3-wire inputs for


Original
PDF 1769-IR6) 1769-UM005A-EN-P 1769-UM005A-EN-P 1769-IR6 belden 9533 1769-ECR micrologix 1500 manual PT3916 1769-IA16 1769-ADN 1769-ECR 1769-UM005 1769-RTBN18
rtd circuit output 10v

Abstract: PT100 RTD IEC 751 pt100 W5 basic model circuit for pt100 NICR-NI thermocouple 0,600 RTD PT-100 W26Re THERMOCOUPLE PT100 J TYPE OR K TYPE rtd frequency response NICR-NI thermocouple
Text: Interface Cable Configuration Software Table 1 Measured Variables RTD : 2, 3 , or 4- wire Pt 100 , =300 (IOUT), RL=4k (VOUT), PT100, 3 - wire , 0-600°C Module DSCP80 Input Range, Thermocouple , -04 (Basic Configuration)( 3 ) User Configurable RTD or Thermocouple, 85 to 230VDC/AC Power 0/2 to 10V , reference conditions. Does not include CJC error. (2) Shipped as PT 100 for 3-wire connection, 0 to 600°C range, 4 to 20mA output, open circuit detect = 21.6mA output. ( 3 ) Shipped as PT 100 for 3-wire


Original
PDF DSCP80 DSCP80 DSCX-887 DSCX-416 DSCX-895 RS-232C. rtd circuit output 10v PT100 RTD IEC 751 pt100 W5 basic model circuit for pt100 NICR-NI thermocouple 0,600 RTD PT-100 W26Re THERMOCOUPLE PT100 J TYPE OR K TYPE rtd frequency response NICR-NI thermocouple
1966 - 1746-NR4

Abstract: belden 9533 1747ASB fault codes RC21-4-1966 1746-IN012 Allen-Bradley 1746-NR4 conveyor motor CONTROLLOGIX DIGITAL OUTPUT CARD 1747-RM001 1747-SG001
Text: roadmap to help you get started using the RTD module. 3 Install and Wire Provides installation , chapter 3 , Install and Wire . Make sure system power is off; then insert the RTD module into your 1746 , wiring an RTD unit to the module, see chapter 3 . Two Wire RTD Interconnection Add jumper. Cable , (3916)(2) (1) The temperature range for the 1000 RTD is dependant on the excitation current , platinum RTD with = 0.00385 / -°C or simply 0.00385 /°C. ( 3 ) Actual value at 0 °C (32 °F) is 9.042


Original
PDF 1746-NR4 1746-UM008B-EN-P 1746-NR4 belden 9533 1747ASB fault codes RC21-4-1966 1746-IN012 Allen-Bradley 1746-NR4 conveyor motor CONTROLLOGIX DIGITAL OUTPUT CARD 1747-RM001 1747-SG001
2007 - PT-100 385 4wire

Abstract: RTD PT-100 ni 9219 RTD pt 100 PT-1000 RTD 3 wire RTD CIRCUITS analog instruments PT-100 385 3wire 72511 calibration certificate of k type thermocouple IEEE 1451.4 RTD
Text: , 1.05 K Thermocouple ±125 mV ±125 mV 4- Wire and 3-Wire RTD Pt 1000 , Pt 100 5.05 K, 505 , -Wire2 Resistance, 1 K ±0.1, ±0.5 ±1200, ±3200 4- Wire and 3-Wire RTD , Pt 1000 ±0.1, ±0.5 ±240, ±640 4- Wire and 3-Wire RTD , Pt 100 ±0.1, ±0.5 ±2400, ±6400 Quarter-Bridge, 350 ±0.1, ±0.5 , Resistance, 1 K ±15 ±30 4- Wire and 3-Wire RTD , Pt 1000 ±15 ±6 4- Wire and 3-Wire RTD , Pt 100 , , Pt 1000 7.6 1.7 1.1 0.4 4- Wire and 3-Wire RTD , Pt 100 10.8 1.9 1.9 0.9


Original
PDF 72252A-01 Mar07 PT-100 385 4wire RTD PT-100 ni 9219 RTD pt 100 PT-1000 RTD 3 wire RTD CIRCUITS analog instruments PT-100 385 3wire 72511 calibration certificate of k type thermocouple IEEE 1451.4 RTD
Not Available

Abstract: No abstract text available
Text: Connections 2 or 3 wire Input Type Pt, Balco and Ni RTD Input Impedance 10 k. NMR @ 50/60 Hz 100 dB , ) JIS RTD 100 ohms.= 0.00392) Pt 1000 RTD : Pt -40 ~ 160° C Balco 500 RTD : -30 ~ 120° C Ni 518: -80 , Module 7-ch RTD Input Module ADAM-6060 ADAM-6066 Specifications Specifications General , Consumption  Watchdog Timer 6 DI Logic level 0: close to GND Logic level 1: open Logic level 0: + 3 , 6 DI Logic level 0: close to GND Logic level 1: open Logic level 0: + 3 V max Logic level 1: 10


Original
PDF ADAM-6060 ADAM-6066 ADAM-6015 GND20Â
2002 - Not Available

Abstract: No abstract text available
Text: ) Model No. CL-474 Price Description $795 High accuracy handheld RTD calibrator Includes 4- wire RTD test leads, 2- wire milliamp test leads, 1 pair alligator clips, 4 spade lug adaptors, 1 pair , OTP-U-F and 3 -pin copper mini-banana plug 2- wire milliamp adaptor with mini-banana plug and two , Laboratory Precision Calibrator Model CL-474 For RTD Model CL-474 $ 795 Basic Unit MADE IN USA Shown Smaller Than Actual Size. ߜ Calibrates and Measures Temperature ( RTD


Original
PDF CL-474 CL-474
2008 - PT10000

Abstract: maxim pt100 interface PT1000 application note pt1000 sensor interface WITH ADC pt100 2 wire sensor interface ADC pt100 interface current source multiplexer PTS1206 pt100 interface WITH ADC PT100 standard IEC 60751 accuracy APP4875
Text: preferred because each wire adds to the system cost and reliability concerns. The 3-wire , of ±0.30°C. This means that a 3 -foot, 2- wire configuration can be used directly with the PT1000 , 0.015 0.013 362.4 108.0 28.4 84.6 3 0.7 0 100.0 1000.0 8200 27000 , RTD 1000 Lin R RTD 1000 Nom R A ADC Code Err (//°C) (°C) () () () (LSB) 3.85E-03 , 0.1463801 409308 0.00 (V) (V) (%) In Table 4 the R RTD 1000 Lin column represents a linear


Original
PDF PT100, PT1000, MAX11200 com/an4875 AN4875, APP4875, Appnote4875, PT10000 maxim pt100 interface PT1000 application note pt1000 sensor interface WITH ADC pt100 2 wire sensor interface ADC pt100 interface current source multiplexer PTS1206 pt100 interface WITH ADC PT100 standard IEC 60751 accuracy APP4875
2008 - PT10000

Abstract: PT100 standard IEC 60751 accuracy pt1000 sensor interface WITH ADC pt1000 voltage to temperature formula PT1000 application note pt100 smd 1206 pts1206 pt100 multiplexer pt100 interface current source multiplexer pt100 sensor interface WITH ADC
Text: which the RTD element is not mounted close to the ADC, fewer wires are preferred because each wire adds to the system cost and reliability concerns. The 3-wire temperature-sensing technique of Figure 1b , of ±0.30°C. This means that a 3 -foot, 2- wire configuration can be used directly with the PT1000 , 0.015 0.013 362.4 108.0 28.4 84.6 3 0.7 0 100.0 1000.0 8200 27000 , RTD 1000 Lin R RTD 1000 Nom R A ADC Code Err (//°C) (°C) () () () (LSB) 3.85E-03


Original
PDF PT100, PT1000, MAX11200 com/an4875 AN4875, APP4875, Appnote4875, PT10000 PT100 standard IEC 60751 accuracy pt1000 sensor interface WITH ADC pt1000 voltage to temperature formula PT1000 application note pt100 smd 1206 pts1206 pt100 multiplexer pt100 interface current source multiplexer pt100 sensor interface WITH ADC
1999 - RTD PT-300

Abstract: kty PT-100 IBS sl 24 BK-T RTD PT-100 CU 53 k 0538 thermocouple k 900 lg PT 2000 temperature sensor ,kty81 application note KTY81
Text: Resistance temperature detectors ( RTD ) Pin Input 2 Input 1 1 Iout+ as 3 - and 4- wire connection Iout+ as 3 - and 4- wire connection 2 Usensor+ Usensor+ 3 Usensor- Usensor- 4 , Temperature Detectors ( RTD ) and Thermocouples (TC) Number 2 Connecting the RTD sensors 2-, 3 -, and 4- wire , 2-, 3 -, and 4- wire sensors A 4- wire RTDs D Thermocouples B 3-wire RTDs E , TC type J 12 TC type L 3 RTD Ni SAMA B TC type K 13 U1: -20 mV to 150 mV 4


Original
PDF 5425B SAC-4P-M12MS/1 SAC-4P-M12MS/3 SAC-4P-M12MS/5 SAC-4P-M12MR/1 SAC-4P-M12MR/3 SAC-4P-M12MR/5 RTD PT-300 kty PT-100 IBS sl 24 BK-T RTD PT-100 CU 53 k 0538 thermocouple k 900 lg PT 2000 temperature sensor ,kty81 application note KTY81
temperature sensor Landis Ni 1000

Abstract: phoenixcontact 5126
Text: 2.1 2.2 2.3 2.4 2.5 2.6 3 an RTD Sensor Usingthe 2- Wire Connection Method an RTD Sensor Usingthe 3-Wire Connection Method an RTD Sensor Usingthe 4- Wire Connection Method a TC Sensor (Thermocouple) a Current Signal , signal values to a temperature. RTD sensors using the 2, 3 or 4 wire connection method, TC sensors , wire R 0.8kQ MG Shield U (-) U(+) 5126A005 2.2 Connection of an RTD Sensor Using the 3-Wire Connection Method PE RTD 3 wire c z i MG Shield AGnd U (-) U (+) fsi?fiAnr>fi 2.3 Connection of


OCR Scan
PDF
IEC 584-1

Abstract: Thermocouple Type t PT100-1000 RTD 600t SMART Differential Pressure Transmitter abb pt 100 temperature sensor RTD abb PT100 IEC 751 BS4937 600t SMART temperature Transmitter abb Thermocouple Type K ABB thermocouple
Text: (not available with code 3 or 4 at position "d") 3 wire RTD class A 4 wire RTD class A (not available with code 3 or 4 at position "d") 2 wire RTD class B (not available with code 3 or 4 at position "d") 3 wire RTD class B 4 wire RTD class B (not available with code 3 or 4 at position "d" , TRANSMITTER RTD INPUT Resistance thermometer Pt100 3 wires (IEC 751/DIN 43760; = 0.00385) Measuring range , (input) 50% of max. value Effect of sensor cable resistance ( 3-wire ) <0.002 / Humidity 0 to 90


Original
PDF SS/652 IEC 584-1 Thermocouple Type t PT100-1000 RTD 600t SMART Differential Pressure Transmitter abb pt 100 temperature sensor RTD abb PT100 IEC 751 BS4937 600t SMART temperature Transmitter abb Thermocouple Type K ABB thermocouple
JUMO PT500

Abstract: bosch NTC PT500 JUMO PT1000 JUMO jumo 90.2004 PT1000 PT100 JUMO "class A" AMP din 72585 PT500 NTC PT1000 RTD probe JUMO 902040
Text: to +270 °C (short-term +300 °C) ( 3 ) Measuring insert 1 x Pt100 in 2- wire circuit 1 x Pt500 in 2- wire , in mm 29 mm x 121 x x 20 46 ( 3 ) Measuring insert 1 x Pt100 in 2- wire circuit 1 x , ) Page 1/6 Screw-in RTD temperature probes with plug connector Temperature range from -50 to +270 °C , ) Screw-in RTD temperature probes in vibration proof design allow temperature measuring under pressure in , with a Pt 100 temperature probe as per DIN EN 60751, Class B in 2- wire circuit; versions with Pt 500


Original
PDF 315-697-JUMO 1-800-554-JUMO JUMO PT500 bosch NTC PT500 JUMO PT1000 JUMO jumo 90.2004 PT1000 PT100 JUMO "class A" AMP din 72585 PT500 NTC PT1000 RTD probe JUMO 902040
Supplyframe Tracking Pixel