The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LTC4416IMS#TR Linear Technology IC 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, PLASTIC, MSOP-10, Power Management Circuit
LTC2990IMS#TR Linear Technology IC 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, PLASTIC, MSOP-10, Power Management Circuit

POWER TRANSFORMER E154515 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
e154515

Abstract: lei-4 e154515 E58127 E58127 lei-4
Text: “I i" m i r n i n m splitbobbinm m SECONDARY SIZE P A R T NO. E58127 E154515 S E R IE S PARALLEL Ul-l 0 -0 5 0 2 10.0V C.T. @ 50m A 5.0V @ 100mA Ul-l 0 -2 5 0 2 10.0VC.T. @ 250m A 5.0V @ 500m A 6 10.0VC.T. @ 600m A 5.0V @ 1200mA LOW PROFILE FOR PRINTED CIRCUIT APPLICATIONS Ul-l 0 -6 0 0 Ul-l 2 -2 0 0 LO W PROFILE , winding. The UI SERIES of transformers is ideal for low height, critical PC' board power applications in


OCR Scan
PDF E58127 E154515 100mA 1200mA e154515 lei-4 e154515 E58127 E58127 lei-4
2003 - BU63155

Abstract: BTTC B-3067 BTTC B-3300 mlp-2005 32-PAD JESD-51-5 TST-9017 bu-63155 B-3067 B-3227
Text: Operation · 0.28 x 0.28" (7 X 7 mm) Body and Footprint Size · Requires Only +5.0V Power Supply · Low Power , . Features include: +5.0V power supply voltage, Harris interface type, and an ultra low profile, small , recommended transformers, the transmitter typically produces 21.5Vp-p for transformer coupled outputs and , disables the transmitter when activated with a logic "1". The ultra small size, +5.0V power supply voltage , II data SHORT OR LONG STUB COUPLING ISOLATION TRANSFORMER 2 BU-63155L3 B-04/05-0


Original
PDF BU-63155L3 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, BU63155 Plas2482 BTTC B-3067 BTTC B-3300 mlp-2005 JESD-51-5 TST-9017 B-3067 B-3227
1998 - LM2574 CALCULATIONS

Abstract: LM2952 200 AMP 24 VDC power supply transformer calculation lm2577 lm2596 sub-50W UPL1V331MPH transformer LM2576 switching transformer winding 2W flyback transformer
Text: voltage. The line transformer is the only portion of the power supply which needs to meet UL1950 , transformer (see Figure 2) can be easily designed using National Semiconductor's Power ICs. Standard data , size of the transformer is a function of a number of items: output power , load regulation, efficiency , transformer only www.national.com needs to provide 11W. By reducing the required power , line , from the transformer . This is very close to UNDERVOLTAGE LOCKOUT Although the power supply is


Original
PDF su959 LM2574 CALCULATIONS LM2952 200 AMP 24 VDC power supply transformer calculation lm2577 lm2596 sub-50W UPL1V331MPH transformer LM2576 switching transformer winding 2W flyback transformer
high frequency step up transformer

Abstract: step down transformer 10 pin flyback transformer step down high frequency transformer step down transformer 12 flyback transformer pin power transformer samwha transformer 18 pin flyback transformer Samwha Electric
Text: . > Multi-Output DC-DC Converter Transformer for low-Input Power supplies. > Available on tape and reel for , . > Surface Mounting type. > Multi-Output DC-DC Converter Transformer for low-Input Power supplies , . > Multi-Output DC-DC Converter Transformer for low-Input Power supplies. > Available on tape and reel for , . > Multi-Output DC-DC Converter Transformer for low-Input Power supplies. > Available on tape and reel for , Converter Transformer for low-Input Power supplies. > Available on tape and reel for automatic insertion


OCR Scan
PDF 500kHz. SD08AU5820-220 SD10AS1249 SD10AS1254 SD10AS1262 500kHz high frequency step up transformer step down transformer 10 pin flyback transformer step down high frequency transformer step down transformer 12 flyback transformer pin power transformer samwha transformer 18 pin flyback transformer Samwha Electric
1996 - VARISTOR k275

Abstract: 07 k275 varistor k275 varistor U2008B equivalent 05 k275 capacitor k275 zener k275 k275 07 K275 T2D19
Text: ) is far below the mains voltage, therefore a transformer or power supply unit is necessary when , power transistors and the transformer . Starter Circuit During every half-wave of the mains, the , the power transistors. These imbalances may produce a dc portion at the main transformer , Tr2. This leads to electromagnetic losses in the transformer . Storage time differences between the power , protected against overload because the power semiconductors and transformer Tr2 can only be loaded up to a


Original
PDF ANT011 U2008B VARISTOR k275 07 k275 varistor k275 varistor U2008B equivalent 05 k275 capacitor k275 zener k275 k275 07 K275 T2D19
1999 - b-3067

Abstract: BUS-25679 BU-65620 ddc b-3067 HLP-6002 datasheet center tapped transformer BU-61590 BTTC B-3067 B-3067 TRANSFORMER 12v center tap transformer
Text: Instantaneous power dissipation (when transmitting) is approximately 0.5 W (typ), 0.8 W (max). (4) Transformer , the subsystem to the data bus." By definition, the terminal includes the isolation transformer as , , therefore, includes selection and interconnection of the isolation transformer . In order to ensure proper , transformers, and the system connector. Other matters discussed involve power distribution, layout strategy , series hybrids to a 1553 data bus. Connections for both direct (short stub) and transformer (long stub


Original
PDF AN/B-27 MIL-STD-1553B 1-800-DDC-5757 A5976 b-3067 BUS-25679 BU-65620 ddc b-3067 HLP-6002 datasheet center tapped transformer BU-61590 BTTC B-3067 B-3067 TRANSFORMER 12v center tap transformer
2013 - transformer 330 MVA

Abstract: merlin gerin switchgear schneider transformer 100mva transformer distribution transformers
Text: Electric has a large network of transformer manufacturing plants around the world, producing medium power , , measurement and power transformers. Overview Transformer Solutions We are proud to present to you , 9001 Standards. Transformer Selection Tables 1 Power Transformers Page 3 Distribution , . Overview The Minera oil-immersed medium voltage power transformer is dedicated to all applications up to , standards. 2 Minera Ex Transformer Technical Characteristics Rated power : up to 60MVA. Rated


Original
PDF 150195C; PGE210184; EC008813; C2356 SEAU26703 SAUENGPRODUCT13 transformer 330 MVA merlin gerin switchgear schneider transformer 100mva transformer distribution transformers
2003 - Not Available

Abstract: No abstract text available
Text: specifications are preliminary and subject to change. Power dissipation specifications assume a transformer , +125°C Operation • 0.28 x 0.28" (7 X 7 mm) Body and Footprint Size • Requires Only +5.0V Power Supply • Low Power Consumption • 32-Pad LPCC Package • 0.040" (1 mm) Maximum Height • Single , provides full dual redundancy. Features include: +5.0V power supply voltage, Harris interface type, and an , -p for transformer coupled outputs and 7.5Vp-p at the bus. An external input, TX INHIBIT, takes priority


Original
PDF BU-63155L3 MIL-STD-1553 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, BU63155 1-800-DDC-5757 A5976
Allen-Bradley starter 709

Abstract: Allen-Bradley 709 starter Allen-Bradley bulletin 712 Bulletin 709 Motor Starter Coil Allen-Bradley 800T Bulletin 509 contactor coils Allen-Bradley bulletin 509 starter Allen-Bradley 709 Allen-Bradley reduced voltage starter Allen-Bradley contactor 100
Text: where the load's power factor Transformer curve intersects the impedance load line is needed to deter , , must intersect the 75VA transformer regulation curve at the calculated power factor of 80.3 percent and , TRANSFORMER SELECTION Purpose Introduction Description Considerations for Selecting the Transformer The , The control circuit transformer is a device designed to provide a reduced control voltage for , devices make up the majority of the loads supplied by the control circuit transformer . The proper size, or


OCR Scan
PDF
2011 - 12v transformer winding formula

Abstract: HALO Electronics tgmr multiple winding Transformer 8 pin 24v transformer center tapped transformer 12v 3A RS 7915 400 v isolation transformer MAX13256 bridge rectifier 24V AC to 24v dc TGMR
Text: 19-5847; Rev 1; 8/11 EVALUATION KIT AVAILABLE MAX13256 36V H-Bridge Transformer Driver for Isolated Supplies General Description The MAX13256 H-bridge transformer driver provides a simple solution for making isolated power supplies up to 10W. The device drives a transformer 's primary coil with , temperatures when delivering maximum output power . Component Selection Transformer Selection , addition to the constraint on ET product, choose a transformer with a low DC-winding resistance. Power


Original
PDF MAX13256 MAX13256 300mA 12v transformer winding formula HALO Electronics tgmr multiple winding Transformer 8 pin 24v transformer center tapped transformer 12v 3A RS 7915 400 v isolation transformer bridge rectifier 24V AC to 24v dc TGMR
1994 - 24v dc power supply with uc3842

Abstract: ST204A switching power supply transformer construction smps with uc3842 and tl431 UC3842 smps design with TL431 3842 PWM power supply application note nec2501 3842 smps IC "Power Semiconductor Applications" Philips TOPSWITCH AN-17
Text: TOPSwitch. For a more detailed treatment of flyback power supply and transformer design refer to , same transformer , rectifier, and output filter. The resulting design is shown in Figure 3. The power , power supply having a fan or transformer connected directly across the AC input, as these components , effect of DMAX and VOR on power supply and transformer design is discussed in application notes AN , inductance, and low winding capacitance. DC Losses The only significant DC losses in a power transformer


Original
PDF AN-19 24v dc power supply with uc3842 ST204A switching power supply transformer construction smps with uc3842 and tl431 UC3842 smps design with TL431 3842 PWM power supply application note nec2501 3842 smps IC "Power Semiconductor Applications" Philips TOPSWITCH AN-17
2003 - BU-63155L3

Abstract: TSM-2205 DSS-1005 B-3227 bu-63155 1553* driver BU63155L3 BU63155 Q9100
Text: subject to change. Power dissipation specifications assume a transformer coupled configuration with , +125°C Operation · 0.28 x 0.28" (7 X 7 mm) Body and Footprint Size · Requires Only +5.0V Power Supply · Low Power Consumption · 32-Pad LPCC Package · 0.040" (1 mm) Maximum Height · Single Transceiver Allows , dual redundancy. Features include: +5.0V power supply voltage, Harris interface type, and an ultra low , used with the recommended transformers, the transmitter typically produces 21.5Vp-p for transformer


Original
PDF BU-63155L3 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, AS9100C BU-63155L3 TSM-2205 DSS-1005 B-3227 1553* driver BU63155L3 BU63155 Q9100
1994 - EF25 transformer

Abstract: etd39 core type smps full bridge transformer design Nyleze AN-16 topswitch EF20 TRANSFORMER TDK EF25 epoxylite 203 EE19 TDK Ferrite Core PC40 EPOXYLITE 814 EFD20 TDK Ferrite Core PC40
Text: core types for various power levels and transformer construction types can be found in Appendix A , international safety regulations, a transformer for use in an off-line power supply must have adequate , /2 to 2/3 of the size of a transformer of the same power capability using a magnet wire design , layers in the transformer . A 7/96 5 AN-18 For power supplies using a primary regulation scheme , secondary windings, the highest power secondary should be the closest to the primary of the transformer


Original
PDF AN-18 AN-16. EF25 transformer etd39 core type smps full bridge transformer design Nyleze AN-16 topswitch EF20 TRANSFORMER TDK EF25 epoxylite 203 EE19 TDK Ferrite Core PC40 EPOXYLITE 814 EFD20 TDK Ferrite Core PC40
2003 - BTTC B-3300

Abstract: BTTC b-3226 B-3818 LPB-5015 MMT-3005 BU63155 3205 decoder TST-9007 MLP-2205
Text: Operation · 0.28 x 0.28" (7 X 7 mm) Body and Footprint Size · Requires Only +5.0V Power Supply · Low Power , . Features include: +5.0V power supply voltage, Harris interface type, and an ultra low profile, small , recommended transformers, the transmitter typically produces 21.5Vp-p for transformer coupled outputs and , disables the transmitter when activated with a logic "1". The ultra small size, +5.0V power supply voltage , II data SHORT OR LONG STUB COUPLING ISOLATION TRANSFORMER 2 BU-63155L3 C-10/05-0


Original
PDF BU-63155L3 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, BU63155 Plas2482 BTTC B-3300 BTTC b-3226 B-3818 LPB-5015 MMT-3005 3205 decoder TST-9007 MLP-2205
transformer calculation ret 521

Abstract: automatic phase changer file 0-12 1a transformer step down transformer winding ratio automatic phase changer tap transformer mva BO-02 3 phase automatic phase changer neutral and earth calculation ABB tripping curves
Text: power transformer rating and instrument transformer ratios to allow protection settings · , ), of the power transformer rating, thus facilitating the protection settings to an optimum. The RET , -winding applications 2-winding power transformer 2-winding power transformer with unconnected delta tertiary winding 2-winding power transformer with 2 circuit breakers on one side 2-winding power transformer with , transformer with all three windings connected 3-winding power transformer with 2 circuit breakers and 2


Original
PDF 012-BEN SE960158) 010-BEN 001-BEN 015-BEN 057-BEN S-721 transformer calculation ret 521 automatic phase changer file 0-12 1a transformer step down transformer winding ratio automatic phase changer tap transformer mva BO-02 3 phase automatic phase changer neutral and earth calculation ABB tripping curves
SM51108

Abstract: PT6102x impulse generator 2035-09-SM coupling transformer ethernet SM511 CDSOT23-SRV05-4 TVS diode Application ethernet PT44216M4 2036-09-SM
Text: protection solutions for Ethernet applications Protecting the secondary-side of the transformer Protecting the primary-side of the transformer 6 7 8 Extended impulse withstand capability Protecting a GDT under AC 9 12 RJ45 Ethernet socket integration 13 PoE ( Power over Ethernet , relied on the robustness of the transformer to provide the protection. Transformers provide a high level , where the transformer saturates (a minimum of 8 mA DC for Ethernet transformers) and this occurs when


Original
PDF GR-1089-CORE CDNBS04-B08200 CD2320-B1200 CD214C-T54ALF SM51108 PT6102x impulse generator 2035-09-SM coupling transformer ethernet SM511 CDSOT23-SRV05-4 TVS diode Application ethernet PT44216M4 2036-09-SM
2012 - step down transformer 30v schematic

Abstract: Halogen transformer schematic SMPS 24V 50w
Text: Lightech LET-75. Bench Circuit IIN LINE LINE 120VAC Power Supply VIN +12V Transformer , . The electronic transformer used was the Lightech LET-75. Bench Circuit I1 LINE 120VAC Power , the transformer is not “on” during the full power cycle, power supplied to the LED driver is not , transformer . LET-75 Specs VIN IIN PIN (1) VOUT (1) ILED (2) POUT Efficiency Power Factor , . 16 Reference Design Transformer Compatibility


Original
PDF LM3401 step down transformer 30v schematic Halogen transformer schematic SMPS 24V 50w
2011 - diode st1

Abstract: Current transformer switching transformer 24v
Text: transformer with a low DC-winding resistance. Power dissipation of the transformer due to the copper loss is , Transformer Driver for Isolated Supplies General Description The MAX13256 H-bridge transformer driver provides a simple solution for making isolated power supplies up to 10W. The device drives a transformerâ , guarantees a fixed 50% duty cycle to prevent DC current flow through the transformer , regardless of which , Transformer  Undervoltage Lockout  2.5V to 5V Compatible Logic Interface  Internal or External


Original
PDF MAX13256 MAX13256 300mA diode st1 Current transformer switching transformer 24v
2002 - LM2952

Abstract: National Semiconductor Power Supply Design with SIMPLESWITCHER LM2574 CALCULATIONS lm2577 boost buck multiple winding Transformer transformer calculation "Linear Voltage Regulator" 132 v 100 kHz flyback transformer AN-1061 LM2675
Text: line voltage. The line transformer is the only portion of the power supply which needs to meet UL1950 , transformer (see Figure 2) can be easily designed using National Semiconductor's Power ICs. Standard data , 01289602 FIGURE 2. Power Supply Solution Using Isolation Transformer and Low-Voltage DC/DC Converters , %. The size of the transformer is a function of a number of items: output power , load regulation , calculations for power loss in the linear regula- tors will be performed at 132 VAC input to the transformer


Original
PDF AN-1061 LM2952 National Semiconductor Power Supply Design with SIMPLESWITCHER LM2574 CALCULATIONS lm2577 boost buck multiple winding Transformer transformer calculation "Linear Voltage Regulator" 132 v 100 kHz flyback transformer AN-1061 LM2675
Not Available

Abstract: No abstract text available
Text: ), the space is restricted and the accuracy of the current transformer must be sufficient for the power , data 3-phase voltage transformer IP20 400V AC, 0.013A Frequency Fuse Rated power Connection , Netzqualitäts-Lösungen Software & Zubehör Power Quality Monitoring Power Management Power Quality Solutions , Current transformers – the link between power currents and digital technology Obviously currents of , whether these are moulded case type current transformer , summation current transformer or cable split core


Original
PDF EN/IEC60900 D-35633
transformer calculation formula

Abstract: N55B mil-std-1553b SPECIFICATION transformer calculation ATAN TECHNOLOGY hp4192a analyzer MIL-STD-1553B HP4192A ACT4487 ACT4454
Text: , or has power removed, shall be a minimum of 1000 ohms ( transformer coupled stub) or 2000 ohms , to find the transceiver input impedance when it has power removed or when it has power on but is in , transmitting (inhibited) and expect the end user to figure out if that means power on or off and at what , impedance of which the transceiver is only one component. The other component is the "Isolation Transformer " that connects the transceiver to the bus, either directly or through a transformer coupled stub. The


Original
PDF
2003 - DSA00312587

Abstract: B-3067 BTTC B-3067 TST-9117 BU-63155L3 BU63155 LPB-5015 B-3310 TLP1005 SLP-8107
Text: Operation · 0.28 x 0.28" (7 X 7 mm) Body and Footprint Size · Requires Only +5.0V Power Supply · Low Power , . Features include: +5.0V power supply voltage, Harris interface type, and an ultra low profile, small , recommended transformers, the transmitter typically produces 21.5Vp-p for transformer coupled outputs and , disables the transmitter when activated with a logic "1". The ultra small size, +5.0V power supply voltage , II data SHORT OR LONG STUB COUPLING ISOLATION TRANSFORMER 2 BU-63155L3 Rev E-04/08-0


Original
PDF BU-63155L3 MIL-STD-1553 32-Pad BU-63155 MIL-STD-1553A, 1553B, BU63155 1-800-DDC-5757 DSA00312587 B-3067 BTTC B-3067 TST-9117 BU-63155L3 LPB-5015 B-3310 TLP1005 SLP-8107
2009 - ts audio transformer

Abstract: TPA3123D2 SLOA133 step down transformer function audio output transformer C2RMS
Text: Application Report SLOA133 ­ March 2009 Audio Power Amplifier Operation with Transformer Load , Power Amplifier Operation with Transformer Load 1 Introduction www.ti.com C2: TPA3123D2 , . Transformer Primary and Load Voltages and Saturation Current Without APA Shutdown 2 Audio Power , 2009 Submit Documentation Feedback Audio Power Amplifier Operation with Transformer Load 3 , Audio and Imaging Products ABSTRACT A Class-D audio power amplifier (APA) driving an output


Original
PDF SLOA133 ts audio transformer TPA3123D2 SLOA133 step down transformer function audio output transformer C2RMS
2014 - dimmer LED

Abstract: lutron light dimmer halogen dimmer
Text: transformer . Power consumed is simply related to the amount of applied RMS voltage, independent of waveform , constant amount of power to the transformer . System-based or panel-mounted dimmers do not usually use , research, evaluate, publicize, and properly match LED loads with the optimal control, transformer or power , device is required to convert line-voltage (120, 230, or 277 V) power into low-voltage needed for the lighting load. This device is either a magnetic low-voltage (MLV) transformer or an electronic low-voltage


Original
PDF
1999 - Pulse Transformer VAC

Abstract: pulse transformer driver ic chopper transformer winding floating gate pulse transformer floating gate drive pulse transformer VAC PULSE TRANSFORMER 1606a mosfet chopper transformer gate drive pulse transformer 1606A
Text: transformer The power MOSFET switches are supplied by pulses from the transformer . No floating auxiliary , operating, the Power MOSFET input capacitor is discharged through the pulse transformer , causing an alarm , transformer . 6. CONCLUSION This Power MOSFET drive is perfectly suited to drive floating and/or isolated , long as suitably rated power switches are used. Its transformer windings are laid on a double-sided , ® APPLICATION NOTE AN ISOLATED GATE DRIVE FOR POWER MOSFETs AND IGBTs by J.M. Bourgeois


Original
PDF
Supplyframe Tracking Pixel