The Datasheet Archive

Top Results (3)

Part Manufacturer Description Datasheet Download Buy Part
TC161A4215EOA723 Microchip Technology Inc 0.25 A SWITCHING REGULATOR, 100 kHz SWITCHING FREQ-MAX, PDSO8
TC151B1945EOA723 Microchip Technology Inc 0.25 A SWITCHING REGULATOR, 50 kHz SWITCHING FREQ-MAX, PDSO8
LM4041CIM-ADJ Microchip Technology Inc Two Terminal Voltage Reference, 1 Output, 1.233V, Trim/Adjustable, BIPolar, PDSO8, SOIC-8
SF Impression Pixel

Search Stock (2)

  You can filter table by choosing multiple options from dropdownShowing 2 results of 2
Part Manufacturer Supplier Stock Best Price Price Each Buy Part
POE75U-1UP-R Phihong USA Allied Electronics & Automation 373 $114.14 $102.26
POE75U-1UP(RS) Phihong USA RS Components 24 £81.56 £65.25

No Results Found

POE75U-1UP-R Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
POE61U

Abstract: Phihong psa16u-480 ce 2087 Single Port Midspan Power Injector saa 5020 560DG
Text: 36.30 36.30 34.56 36.30 Fully IEEE802.3at Compliant ( POE75U-1UP-R Only) Broken Wire Detection , . 70124103 70124182 Mfr.'s Type POE60U-560(G)- R POE75U-1UP-R Output Voltage* 56 56 Load (Amps) Min. 0 0 , Separately - See Page 981 - R-Series Interchangeable AC Plugs Ripple P-P mV 150 C UL R US 15.4 Watt , , Over-Current Protection C UL R US INTERCONNECT Stock No. 70124110 Regulation Line ±4% Load ±4% 1-9 15.23 EACH 10-24 14.78 Load (Amps) Min. 0 Max. 0.275 Mfr.'s Type PSA16U-480(POE)- R Output Voltage 48.0


Original
PDF IEEE802 POE80U-560 POE21-120-R POE21-240-R POE61U Phihong psa16u-480 ce 2087 Single Port Midspan Power Injector saa 5020 560DG
Not Available

Abstract: No abstract text available
Text: WWW.PHIHONG.COM 60W Power over Ethernet Splitter POE60 Ultra PoE Gigabit Splitter Designed to work with POE75U- 1UP Single port Features     WiMAX Access Point Last Mile Wireless Gigabit Compatible Non-Vented Case Diagnostic LEDs 1 Year Warranty Computer Workstation Multi Radio Access Points   Applications      ï , POE75U- 1UP 1.1A Phihong is not responsible for any error, and reserves the right to make changes


Original
PDF POE60 POE75U-1UP IEEE802 POE75U 100mm 55-57VDC 50VDC 53Vinput EN61000-4-2. EN61000-4-3.
POE60U

Abstract: No abstract text available
Text: POE75U- 1UP 47-57V DC WWW.PHIHONG.COM Immunity ESD: RS: EN61000-4-2 EN61000-4-3 Level 3


Original
PDF POE45 IEEE802 POE60U POE75U 140mm 120mV
power injector

Abstract: EN61000-4-2 EN61000-4-3 EN61000-4-4
Text: ) Width: 80mm (3.15in) Output Specifications Model DC Output Voltage* POE75U- 1UP (x) +56V


Original
PDF IEEE802 power injector EN61000-4-2 EN61000-4-3 EN61000-4-4
Not Available

Abstract: No abstract text available
Text: POE75U- 1UP 47-57V DC WWW.PHIHONG.COM Immunity ESD: RS: EN61000-4-2 EN61000-4-3 Level 3


Original
PDF POE45 IEEE802 POE60U POE75U 140mm 120mV
12VLOAD

Abstract: POE75U EN61000-4-2 EN61000-4-3
Text: Voltage Range Operates with POE60U-560G or POE75U- 1UP 47-57V DC WWW.PHIHONG.COM Immunity ESD: RS


Original
PDF POE45 IEEE802 POE60U POE75U 05ozs) POE45-120 12ondary: 120mV 12VLOAD EN61000-4-2 EN61000-4-3
Not Available

Abstract: No abstract text available
Text: ‚· Height: 44mm (1.73in) Weight: 0.5Kg Output Specifications Model DC Output Voltage* POE75U- 1UP


Original
PDF 166mm
Not Available

Abstract: No abstract text available
Text: ) Model Output POE61S-4AF- R 15.4W per port on 4 ports Total power-62W Phihong is not , -4-5. Level 2 CS: EN61000-4-6. Level 2 Note: RS and CS tested with POE75U- 1UP Isolation Test Input to


Original
PDF 176mm 300mm 184mm 200meters PGLAND750/PGLAND750-2 IEEE802 POE61S PGLAND750 PGLAND750-2
Not Available

Abstract: No abstract text available
Text: ‚· Height: 44mm (1.73in) Weight: 0.5Kg Output Specifications Model DC Output Voltage* POE75U- 1UP


Original
PDF IEEE802 AP1250 166mm
POE61S-4AF

Abstract: No abstract text available
Text: ) Weight: 2.83Kg (6.25lb) Model Output POE61S-4AF- R 15.4W per port on 4 ports Total power , -4-4. Level 2 Surge: EN61000-4-5. Level 2 CS: EN61000-4-6. Level 2 Note: RS and CS tested with POE75U- 1UP


Original
PDF 176mm 300mm 184mm 200meters PGLAND750/PGLAND750-2 IEEE802 POE61S PGLAND750* PGLAND750-2* POE61S-4AF
POE75D-1UP

Abstract: No abstract text available
Text: (6.53in) Width: 80mm (3.15in) Output Specifications Model DC Output Voltage POE75D- 1UP +56V


Original
PDF 166mm 15inon POE75D-1UP
2012 - Phihong psa16u-480

Abstract: No abstract text available
Text: No POE60U-560(G)†Yes No POE75U- 1UP Yes Yes Yes POE75U-1UPN Yes No POE75D- 1UP Yes No POE80U-560(G) Yes Yes No POE240U-4UP†Yes Yes Yes


Original
PDF
POE60S-4AF

Abstract: No abstract text available
Text: No file text available


Original
PDF 200meters PSC75U-560 174mm 154mm POE60S-4AF EN61000-4-2. EN61000-4-3. EN61000-4-6. POE75U-560 EN55022 POE60S-4AF
Not Available

Abstract: No abstract text available
Text: No file text available


Original
PDF 200meters PSC75U-560 174mm 154mm POE60S-4AF EN61000-4-2. EN61000-4-3. EN61000-4-6. POE75U-560 EN55022
2004 - Not Available

Abstract: No abstract text available
Text: 3.3V 0 = 5V X = 5.2V W= 5.5V V = 5.8V T = 6.5V R = 7.5V M = 10V 1 = 12V P = 13.8V 2 = 15V N = 18.5V 3 = , 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3-up MIL-STD-461C - 1-up MIL-STD-461D - 1-up , minimum for 1-up ComPAC · 8 mA DC minimum for 2-up ComPAC · 12 mA DC minimum for 3-up ComPAC The , Case-to-Air (°C/W) Standard Units 1-up Free Air (Horiz.) 3.6 2-up 1.7 3-up 1.4 With Optional Heat Sink (1) 1-up 2.1 2-up 1.3 3-up 1.0 Forced Convection Through Heat Sink Fins 50 LFM 100 LFM 250 LFM 500


Original
PDF 28Vdc MIL-STD-704A, MIL-STD-1275A/B 270Vdc MIL-STD-704D/E 48Vdc MIL-STD-461C/D/E 270Vdc.
MIL-STD-1275A

Abstract: MIL-STD-704D ce07 MIL-STD-1275 CE01 MIL-STD-461C MC-150 CS116 CE102 270vdc
Text: = 3.3V 0 = 5V X = 5.2V W= 5.5V V = 5.8V T = 6.5V R = 7.5V M = 10V 1 = 12V P = 13.8V 2 = , CS01, CS02, CS06 CS101, CS114, CS116 CS101, CS114, CS116 MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3-up MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3 , Disable Circuit 20 mA Max. Disable + V DIS+ DIS­ Disable Current · 4mA DC minimum for 1-up , ) With Optional Heat Sink (1) Standard Units 1-up 2-up 3-up 1-up 2-up 3-up Free Air


Original
PDF 28Vdc MIL-STD-704A, MIL-STD-1275A 270Vdc MIL-STD-704D/E 48Vdc MIL-STD-461C/D/E MIL-STD-1275A, MIL-STD-1275A MIL-STD-704D ce07 MIL-STD-1275 CE01 MIL-STD-461C MC-150 CS116 CE102
2003 - 270vdc

Abstract: No abstract text available
Text: = 5.5V V = 5.8V T = 6.5V R = 7.5V M = 10V 1 = 12V P = 13.8V 2 = 15V N = 18.5V 3 = 24V L = 28V J = 36V K = , CS01, CS02, CS06 CS101, CS114, CS116 CS101, CS114, CS116 MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3-up MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3 , + DIS­ V Disable Current · 4mA DC minimum for 1-up ComPAC · 8mA DC minimum for 2-up ComPAC · 12mA , Considerations Thermal Impedance - Case-to-Air (°C/W) Standard Units 1-up Free Air (Horiz.) 3.6 2-up 1.7 3


Original
PDF 28Vdc MIL-STD-704A, MIL-STD-1275A 270Vdc MIL-STD-704D/E 48Vdc MIL-STD-461C/D/E 270Vdc.
2001 - Not Available

Abstract: No abstract text available
Text: CS01, CS02, CS06 CS101, CS114, CS116 CS101, CS114, CS116 MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3-up MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3 , + DIS­ V Disable Current · 4mA DC minimum for 1-up ComPAC · 8mA DC minimum for 2-up ComPAC · 12mA , Considerations Thermal Impedance - Case-to-Air (°C/W) Standard Units 1-up Free Air (Horiz.) 3.6 2-up 1.7 3-up 1.4 With Optional Heat Sink (1) 1-up 2.1 2-up 1.3 3-up 1.0 Forced Convection Through Heat Sink


Original
PDF 28Vdc MIL-STD-704A, MIL-STD-1275A 270Vdc MIL-STD-704D/E 95Vdc MIL-STD-461C/D/E 270Vdc.
2011 - Not Available

Abstract: No abstract text available
Text: [c] 3.3 V[c] 5 V[c] 5.2 V 5.5 V 5.8 V T R M 1 P 2 = = = = = = 6.5 V[d] 7.5 V[d] 10 V 12 V , , CS114, CS116 MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3-up MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3-up Notes Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax , THERMAL CONSIDERATIONS Standard Units 2-Up 1.7 1.4 1.3 1.0 0.7 0.5 0.4 With Optional Heat Sink [a] 1-Up 2 , fins 50 LFM 100 LFM 250 LFM 500 LFM 750 LFM 1000 LFM 1-Up 3.6 2.7 2.3 1.6 1.2 0.9 0.8 3-Up 1.4


Original
PDF MIL-STD-704A-F, MIL-STD-1275A/B/D DO-160E, MIL-STD-704D/E/F MIL-STD-461C/D/E
stakpac

Abstract: No abstract text available
Text: D isable U L , C SA , TUV, V D E (in p ro cess to IEC 950) R em ote Sense and C u rren t Lim it B U S O K and A C O K 50m s R id e-T h rou g h Tim e (typical) O V P and T h erm al S h u td o w n , State Continuous Forward Current Forward Voltage Agencies Conducted and Radiated EMI/RFI 1-up Models 2 , only. Strappable input available as standard option, consult factory.) 1-up models 47 to 63Hz (C-grade , (Optically isolated LED input) *All models except Vl-LFX-XX Product Highlights V i c o r 's F la tP A


OCR Scan
PDF
Triac AC INRUSH CURRENT LIMITER

Abstract: VI-J00
Text: modules ( 1-up , 2-up, 3-up), combined in an integrated mechanical assembly. This assembly provides a , -up FlatPAC, a 12 A / 250 V fuse for the 2-up FlatPAC and a 8 A / 250 V fuse for the 1-up FlatPAC. This , power-up by a pair of inverse parallel SCRs on the 3-up FlatPAC (TRIAC for the 1-up and 2-up FlatPAC , AC-OK + BUS-OK ­ BUS-OK + L1 AC Mains 2-Up and 3-Up 1-Up L2/N Earth Ground GND , . r + AC-OK ­ 1.5 mA max. + V ­ r + BUS-OK ­ Figure 18­2 - External


Original
PDF VI-200 VI-J00 VI-26x Triac AC INRUSH CURRENT LIMITER
2007 - ce07

Abstract: MIL-STD-1275 ce07 series CS116 vicor CE01 DO-160E MIL-STD-704D. Input Transient
Text: = 2V 3.3 V 5V 5.2 V 5.5 V 5.8 V T R M 1 P 2 = = = = = = 6.5 V[c] 7.5 V[c , CE01, CE03, CE07 CE101, CE102 MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3-up CS01, CS02, CS06 MIL-STD-461C - 1-up CS101, CS114, CS116 MIL-STD-461D - 1-up CS101, CS114, CS116 Conducted susceptibility MIL-STD-461C - 1-up CE101 Conducted emissions MIL-STD-461E - 2-up & 3-up Vicor , www.vicorpower.com Rev. 1.1 Page 3 of 6 THERMAL CONSIDERATIONS 1-Up 1.7 With Optional Heat Sink [a


Original
PDF MIL-STD-704A-F, MIL-STD-1275A/B/D DO-160E, MIL-STD-704D/E/F MIL-STD-461C/D/E ce07 MIL-STD-1275 ce07 series CS116 vicor CE01 DO-160E MIL-STD-704D. Input Transient
ce07

Abstract: CS114 MIL-STD-704A
Text: CS01, CS02, CS06 CS101, CS114, CS116 CS101, CS114, CS116 MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3-up MIL-STD-461C - 1-up MIL-STD-461D - 1-up MIL-STD-461E - 2-up & 3 , Disable Circuit 20 mA Max. Disable + V DIS+ DIS­ Disable Current · 4mA DC minimum for 1-up , ) With Optional Heat Sink (1) Standard Units 1-up 2-up 3-up 1-up 2-up 3-up Free Air , Thermal impedance, chassis-to-air, is provided for 1-up , 2-up and 3-up MI-ComPAC package configurations


Original
PDF 28Vdc MIL-STD-704A, MIL-STD-1275A 270Vdc MIL-STD-704D/E 95Vdc MIL-STD-461C/D/E 28Vdc 270Vdc. ce07 CS114 MIL-STD-704A
MIL-STD-461C RS03

Abstract: ce07 CE01 CS01 CS02 CS06 VI-J00
Text: 125 ­ 400 ComPACs can be configured in 1-up , 2-up or 3-up packages with total output power limited , Output Power 1-Up 2-Up 3-Up 150 W 300 W 450 W 100 W 200 W 300 W 200 W 400 W 600 W EMC , input line exceeds the brownout voltage specified for the converter input range. Weight. 1-Up : 1.2 , ). · 4 mA DC minimum for 1-up ComPAC · 8 mA DC minimum for 2-up ComPAC · 12 mA DC minimum for 3 , ) 300 V 1-Up 10 A / 32 V 12 A / 32 V 10 A / 250 V 8 A / 60 V 6 A / 100 V 2 A / 250 V 2 A / 250


Original
PDF VI-200 VI-J00 MIL-STD-461C RS03 ce07 CE01 CS01 CS02 CS06
2004 - Not Available

Abstract: No abstract text available
Text: Voltage Z =2V Y = 3.3 V 0 =5V X = 5.2 V W= 5.5 V V = 5.8 V T = 6.5 V N = 18.5 V R = 7.5 V 3 = 24 , Characteristics Efficiency Baseplate to chassis Thermal shut down Mechanical Specifications Weight 1-up 2 , Characteristics Efficiency Baseplate to chassis Mechanical Specifications Weight 1-up 2-up 3-up (1 , ) 4.90 TYP. (124,5) 0.53 TYP. (13,5) SER. NO. Side view (all models) 1-Up L- and , (6,4) TYP. TOP VIEW 3-Up R - and RJ-Series Q-Series N-Series 0.19 N-Series


Original
PDF
Supplyframe Tracking Pixel