The Datasheet Archive

PN9000 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1995 - PN9000

Abstract: Aeroflex PN9000 pn9000 Absolute Phase Noise Measurements PN9712 PN9650 PN9000 PN9000* Microwave detector diodes programmable rf delay line Digitizing pn9000 PN9560 PN9000 additive noise
Text: signal. ADDITIONAL CAPABILITIES Figure 4 The PN9000's modular architecture allows a wide choice , COMSTRON 6 COMSTRON PN9000 BASE TEST SET The PN9000 system comprises the following items: PN9000A , AUTOMATIC PHASE NOISE MEASUREMENT SYSTEM PN9000 Tomorrow's Phase Noise Testing Today , PN9000 The PN9000 Automated Phase Noise Measurement System (Figures 1 or 2) is the first system , and maintenance purposes. Before the advent of the PN9000 system, phase noise measurements were


Original
PDF PN9000 PN9000 PN9255 PN9230 PN9240 PN9100 PN9710 PN9711 PN9712 Aeroflex PN9000 pn9000 Absolute Phase Noise Measurements PN9712 PN9650 PN9000 PN9000* Microwave detector diodes programmable rf delay line Digitizing pn9000 PN9560 PN9000 additive noise
PN9000

Abstract: Aeroflex PN9000 phase detector 500 khz Aeroflex PN9000 Application Note quadrature detector phase detector 10 khz Comstron Comstron pn9000 Aeroflex Application Note phase noise
Text: discussion to this measurement technique. The Aeroflex Comstron PN9000 Phase Noise Measurement System is , method. Power reduction associated with duty cycle is corrected in the PN9000 software. DC offset and transients are accommodated in the PN9000 by an Operational Low Noise Amplifier following the phase detector , expressed in proportion). e.g. D = 0.1, 20 log (0.1) = -20 dB. The PN9000 accounts for this by means of an , when transients and/or offsets are present. The Aeroflex Comstron PN9000 uses a proprietary Very Low


Original
PDF
2003 - PN9000

Abstract: HP8656B HP6624A system DC power supply pn9000 Absolute Phase Noise Measurements SCAA059 MC100EP 11801C SCAU007 HP6624A Aeroflex PN9000
Text: PN9000.4 Test Setup for Phase Jitter Measurements Taken From Tektronix TDS694C and , , conditioned by HP8133A. A 622.08-MHz VCXO served as the clock source for the AeroFlex PN9000. VCXO + H , .6 2.2 PN9000 Phase Noise Plots .7 2.3 PN9000 Results , .7 PN9000 Phase Jitter Measurements


Original
PDF SCAA068 PN9000 HP8656B HP6624A system DC power supply pn9000 Absolute Phase Noise Measurements SCAA059 MC100EP 11801C SCAU007 HP6624A Aeroflex PN9000
PN9000

Abstract: Aeroflex PN9000 Application Note Digitizing pn9000 pn900 93-0001 Aeroflex PN9000
Text: FAX: 516-694-6771 APPLICATION NOTE #2 PN9000 Automated Phase Noise Measurement System 1 INTRODUCTION This Application Note describes the operational characteristics of the Comstron/Aeroflex PN-9000 Automated Phase Noise Measurement System. The PN-9000 is a modular system which is configurable to support , simplified block diagram of the PN-9000 system. The PN-9000 demodulates the phase fluctuations of the source , Revised 3/14/95 calculated by measuring and setting the characterizing parameters of the loop. The PN-9000


Original
PDF PN9000 PN-9000 Aeroflex PN9000 Application Note Digitizing pn9000 pn900 93-0001 Aeroflex PN9000
2003 - PN9000

Abstract: Aeroflex PN9000 HP8656B CDCLVD110 HP6624A OC48 TDS694C Tektronix 464 B694
Text: Phase Jitter Measurements Taken From AeroFlex PN9000.4 Test Setup for Jitter , HP8133A provided the signal. A VCXO served as the clock source for the AeroFlex PN9000. VCXO HP6624A , .6 2.2 PN9000 Results , Test Setups.7 PN9000 Phase Jitter Measurements , DUT CDCLVD110/ Q4 Competitors AB HP8656B Signal Gen OUT - Areoflex PN9000 Phase Noise


Original
PDF SCAA066 PN9000 Aeroflex PN9000 HP8656B CDCLVD110 HP6624A OC48 TDS694C Tektronix 464 B694
2004 - PN9000

Abstract: M1802 M1804 Aeroflex PN9000 pn9000 Absolute Phase Noise Measurements OC48 HP6624A CDCM1804 CDCM1802 TDS694C
Text: Setup for Phase Noise Measurements Taken from the AeroFlex PN9000.2 PN9000 RMS Phase Jitter Measurements of the CDCM1804 and Competitor A .2 PN9000 Peak-to-Peak Phase Jitter Measurements of the , .2 2.1 PN9000 Results , .2 PN9000 Unit Interval (UI) Phase Jitter Measurements of the CDCM1804 and Competitor PN9000 RMS Phase Jitter Measurements of the CDCM1802 and Competitor B .2 PN9000 Peak-to-Peak


Original
PDF SCAA073 CDCM1804 CDCM1802 PN9000 M1802 M1804 Aeroflex PN9000 pn9000 Absolute Phase Noise Measurements OC48 HP6624A TDS694C
2006 - PN9000

Abstract: ICS553 PN9000 additive noise Clock Buffers Digitizing pn9000 IDT74FCT3807 ICS651 ICS524 PN-9000
Text: Diagram of PN-9000 Figure 2 shows a simplified block diagram of the Aeroflex PN-9000 system. The PN-9000 , computer to which the PN9000 system is connected to and the resulting phase noise is displayed on the , for Measuring Phase Noise using Aeroflex PN9000 IDTTM IDT CLOCK BUFFERS OFFER ULTRA LOW ADDITIVE , PN9000 RF Synthesizer is programmed to output a frequency that is equal to the DUT (IDT clock buffer , correctly using the external manual phase shifter. The assumption in this case is that the PN9000 reference


Original
PDF
2003 - SC4105-06 Legend

Abstract: TOM9008
Text: + 25 ºC +85 ºC -55 ºC Notes: 1. Phase Noise is measured using the Aeroflex PN9000. 2 , Aeroflex PN9000. 2. Worst case phase noise @ 100KHz offset across frequency range and temperature , +85 ºC Notes: 1. Phase Noise is measured using the Aeroflex PN9000. 2. Worst case phase noise @ , Aeroflex PN9000. 2. Worst case phase noise @ 100KHz offset across frequency range and temperature , measured using the Aeroflex PN9000. 2. Worst case phase noise @ 100KHz offset across frequency range and


Original
PDF OM9008, ON9008, BXO9008, SC4105-06 Legend TOM9008
2003 - PN9000

Abstract: Aeroflex PN9000 1.8 GHz SAW oscillator PN9273 PN9274
Text: signal with clean fixed frequencies, providing an IF signal in the range of the PN9000 RF base system. Operating Diagram PN9273/74 MW Down-converter MW DUT PN9000 RF Base System RF Phase detector , simple as it is for RF source measurement (see PN9000 base system). AEROFLEX Test Solutions 35 south


Original
PDF PN9273/74 10kHz PN9000 PN9100 Aeroflex PN9000 1.8 GHz SAW oscillator PN9273 PN9274
10 GHz rf delay line

Abstract: PN9000 Aeroflex PN9000 PN9240 PN9712 rf delay line PN9711 phase shifter PN9713 PN9710
Text: is obtained by adjusting the VCO frequency through the V DC control provided by the PN9000. /2=2F , Tommorrow's Phase Noise Testing Today PN9000 AUTOMATED PHASE NOISE MEASUREMENT SYSTEM DELAY LINE OPTIONS DELAY LINE DELAY LINE TO RF 50 =100 INPUT TO LO 50 50 TO DL , , since it requires no reference. Figure 1 shows the principle of operation for the PN9000 delay line , F: F=1/4=2.6 MHz, with =100ns Since the smallest increments of the PN9000 V DC control is 5 mV


Original
PDF PN9000 20/140nS 20dBm PN9710 PN9711 PN9712 PN9713 PN9710-00 10 GHz rf delay line Aeroflex PN9000 PN9240 PN9712 rf delay line PN9711 phase shifter PN9713 PN9710
transistor 2Fn

Abstract: PN9000 marking 2fn B650
Text: Current Temex measurements are performed with PN9000. Two similar oscillators are used as Reference and , Two oscillators + residual noise Test bench: PN9000 Typical phase noise measurement on PN9000 from , curve on PN9000 (2 oscillators at - 174 dBc/Hz + residual noise at ­ 170 dBc/Hz). · Multi-channel


Original
PDF PN9000 transistor 2Fn PN9000 marking 2fn B650
2009 - PN9000

Abstract: dcnts "Crystal Filters TEMEX Aeroflex DCNTS
Text: as shown below with e. g. the PN9000 setup of Aeroflex: noise floor measurement is limited around ­ , floor is measured at ­ 182 dBc/Hz! Typical phase noise Test setup : Aeroflex PN9000 Noise floor limitation PN9000 noise Typical phase noise Test setup : Aeroflex DCNTS No limitation on noise floor


Original
PDF Exter9000 PN9000 dcnts "Crystal Filters TEMEX Aeroflex DCNTS
2003 - oscillator 77 GHZ

Abstract: PN9100 PN9000
Text: signal with clean fixed frequencies, providing an IF signal in the range of the PN9000 RF base system. Operating Diagram PN9273/74 MW Down-converter PN9000 RF Base System RF Phase detector F.C. LNA A , measurement (see PN9000 base system). AEROFLEX Test Solutions 35 South Service Road ­ Plainview NY 11803 ­


Original
PDF PN9273/74 10kHz PN9000 PN9273/74 PN9100 oscillator 77 GHZ
rakon 10MHz

Abstract: rakon C 5074 transistor 10 bit Controlled Oscillator RAKON oscillator dcnts uln 2 Temex PN9000 E5052B
Text: noise and how to measure it Measurement with PN9000 : Current Rakon Temex measurements are performed with PN9000. Two similar oscillators are used as Reference and DUT. Plotted phase noise is the , sensitivity of the test bench. Current Rakon Temex measurement Test set-up: NoiseXT PN9000 Plot: Sum of


Original
PDF 10MHz 10kHz PN9000 rakon 10MHz rakon C 5074 transistor 10 bit Controlled Oscillator RAKON oscillator dcnts uln 2 Temex PN9000 E5052B
MIL-PRF-28800F

Abstract: MIL-PRF-28800-F B650 rakon MIL-PRF-28800F class 4 PN9000 MILPRF-28800F E5052B SR B650 SAW
Text: Measurement with PN9000 : Current Rakon Temex measurements are performed with PN9000. Two similar oscillators , residual noise Test bench: PN9000 Applications · · Instrumentation (test equipment, simulator


Original
PDF 10kHz MIL-PRF-28800F MIL-PRF-28800-F B650 rakon MIL-PRF-28800F class 4 PN9000 MILPRF-28800F E5052B SR B650 SAW
2005 - Not Available

Abstract: No abstract text available
Text: the Aeroflex PN9000 Phase and Amplitude Noise Test Set. A typical Translation block diagram is shown , designed times 18 multiplier circuit. Aeroflex PN9000 Phase and Amplitude Noise Test Set (shown above


Original
PDF PN9000
2005 - WPN9000

Abstract: PN8000 PN9500 PN9000 PN9348-10 Aeroflex PN9000
Text: The PN8000 is a system similar to the PN9000 , designed for customers who do not need the additional performance of the PN9000 or PN9500 options. The PN8000 uses the Reference Phase Locking Method exclusively , port. The PN8000 comes with similar software to the WPN9000, used on the PN9000 test set. PN8000


Original
PDF PN8000 PN8000 PN9000, PN9000 PN9500 WPN9000 PN9500 PN9348-10 Aeroflex PN9000
rakon

Abstract: PN9000 174dBc B632 E5052B MIL-PRF-28800F class 4
Text: PN9000 : Current Rakon Temex measurements are performed with PN9000. Two similar oscillators are used as , noise Test bench: PN9000 Applications · · Instrumentation (test equipment, simulator) Ground


Original
PDF 10kHz rakon PN9000 174dBc B632 E5052B MIL-PRF-28800F class 4
2012 - MIL-PRF-28800F

Abstract: PN9000 Aeroflex PN9000 E5052B MIL-PRF28800F MIL-PRF-28800F class 4
Text: with PN9000 : Current Rakon measurements are performed with PN9000. Two similar oscillators are used as , noise Test bench: PN9000 Noise XT Sum of 2 oscillators + Residual noise Applications · ·


Original
PDF 480MHz PN9000 10kHz MIL-PRF-28800F Aeroflex PN9000 E5052B MIL-PRF28800F MIL-PRF-28800F class 4
PN9000

Abstract: b248 B232 Aeroflex PN9000
Text: PN9000. Two similar oscillators are used as Reference and DUT. Plotted phase noise is the combined noise , pins for DC supply and VControl Typical phase noise Test bench : PN9000 Sum of 2 oscillators + Residual noise Typical phase noise measurement on PN9000 from NoiseXT Environmental conditions


Original
PDF
Rakon

Abstract: MIL-PRF-28800F b248 E5052B PN9000 B-248 MIL-PRF-28800F class 4
Text: : about phase noise and how to measure it Measurement with PN9000 : Current Rakon Temex measurements are performed with PN9000. Two similar oscillators are used as Reference and DUT. Plotted phase noise is the , DC supply and V control shelters, stabilized platforms Typical phase noise Test bench: PN9000


Original
PDF 10kHz Rakon MIL-PRF-28800F b248 E5052B PN9000 B-248 MIL-PRF-28800F class 4
PN9211

Abstract: PN9000 pn9200 PN9100A PN9210 PN9100
Text: oscillators. The PN9100A synthesizer is constructed as a module which can be plugged into a PN9000 mainframe , a PN9200 Microwave Downconverter is installed in a PN9000 mainframe, its PN9210 Time Base can be , controlled from the PN9000 computer through the internal bus. -90 dBc -30 dBc Non-Harmonics 2 MHz to


Original
PDF PN9100A PN9211 PN9000 pn9200 PN9210 PN9100
rakon

Abstract: ULN 232 Mil-PRF-28800F PN9000 B232 RAKON oscillator MIL-PRF-28800F class 4
Text: PN9000. Two similar oscillators are used as Reference and DUT. Plotted phase noise is the combined noise , . Current Rakon Temex measurement Test set-up: NoiseXT PN9000 Plot: Sum of both oscillators + Residual


Original
PDF 320MHz. -170dBc/Hz 10kHz -180dBc/Hz -190dBc/Hz. -181dBc/Hz: rakon ULN 232 Mil-PRF-28800F PN9000 B232 RAKON oscillator MIL-PRF-28800F class 4
PN9000

Abstract: Aeroflex PN9000 X-band low noise X-band low noise amplifiers
Text: PN9000 Phase and Amplitude Noise Test Set. A typical Translation block diagram is shown below. Also , times 18 multiplier circuit. Aeroflex PN9000 Phase and Amplitude Noise Test Set (shown above) is


Original
PDF PN9000 Aeroflex PN9000 X-band low noise X-band low noise amplifiers
2008 - Aeroflex PN9000

Abstract: PN9000
Text: the Frequency Translators the main piece of test equipment used is the Aeroflex PN9000 Phase and , . Aeroflex PN9000 Phase and Amplitude Noise Test Set (shown above) is used to test Aeroflex / Weinschel


Original
PDF RS-422/232 IEEE-488 RS-310 MIL-STD-189. Aeroflex PN9000 PN9000
Previous1 2 3 ... 5 6 7 Next