The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1025CS8#PBF Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LT1025CN8#PBF Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: PDIP; Pins: 8; Temperature Range: 0°C to 70°C
LT1025CS8#TRPBF Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LT1025ACN8 Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: PDIP; Pins: 8; Temperature Range: 0°C to 70°C
LT1025CS8 Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LT1025CN8 Linear Technology LT1025 - Micropower Thermocouple Cold Junction Compensator; Package: PDIP; Pins: 8; Temperature Range: 0°C to 70°C

Omega k type thermocouple range Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1999 - TAC80B

Abstract: TAC80
Text: °F 0.000 mV 14.862 mV Figure 1-2. Potentiometer Locations K TYPE THERMOCOUPLE LEADS COM , TRP REFERENCE PROBES K TYPE THERMOCOUPLE CONNECTOR Figure 1-3. Calibration Set-up TRC III , ® TAC80B-J, K , T TAC80B-K Thermocouple-to-Analog Converter Thermocouple to Analog , ® TAC80B-J, K , T Thermocouple to Analog Converter can turn any chart recorder, analog or digital voltmeter , amplifier and linearizer which provides a precision 1mV/°C or °F signal for type J, K or T thermocouples


Original
PDF TAC80B-J, TAC80B-K M1710/0394 TAC80B-AC) TAC80B TAC80
2001 - HHM290

Abstract: No abstract text available
Text: Emissivity: 1. Set the Function switch to T/C. 2. Plug in a K type surface thermocouple probe to the meter , multimeter can accept up to two K type thermocouple inputs. 3. Plug in the thermocouple probe(s) to the , Rubber Boot, a pair of test leads, 6 AA size Batteries, One Spare fuse, Type K Beaded wire thermocouple , Input ( K type T/C) Battery Replacement Power is supplied by 6 pcs 1.5V (AA size) battery (UM-3 R6). , ") Temperature Scale: Celsius or Fahrenheit user-selectable Measurement Range : Thermocouple Range K-TYPE


Original
PDF 631111ed EN61010-1 30minutes 12Vmax. 202mm 100mm HHM290
2001 - Not Available

Abstract: No abstract text available
Text: chart below Thermocouple Accuracy Chart (°C) Temperature Range Point Thermocouple Type J K T E , to 95% relative humidity OM-SP1700 SERIES THERMOCOUPLE LOGGER Input Type : thermocouple , type J, K , readily-available thermocouple probes in J, K , T, E, R and S types. Each logger is calibrated during manufacture , accessory current probes Resolution: see thermocouple resolution chart below Input Impedance: >500 K , Repeatability: 0.5% over 0 to 75% RH Thermocouple Resolution Chart (°C) Thermocouple Type Resolution


Original
PDF OM-SP4000 12-bit OM-SP1700-200 OM-SP1700-200 OM-SP2000
2001 - SUPER MCJ

Abstract: No abstract text available
Text: DESCRIPTION This is a Thermocouple to Analog Connector. It converts a thermocouple input signal ( Type J, K , Temperature Range : Type J: -100 to +750°C (-148 to +1382°F) Type K : -100 to +1250°C (-148 to +2282°F) Type T: -100 to +350°C (-148 to +662°F) Accuracy @ 75°F ambient temperature across the range : Type J: ± 1.4°C (± 2.5°F) Type K : ± 3°C (± 5°F) Type T: ± 2°C (± 3°F) Input Connection , Thermocouple Input Super MCJ Analog Output, 1 mV per degree (SMP or OST Connector


Original
PDF M-2813 SUPER MCJ
1999 - Not Available

Abstract: No abstract text available
Text: Type J Thermocouple Input, Range : -105 to 750°C (-157 to 1382°F) Type K Thermocouple Input, Range : -20 to 1200°C (-40 to 2192°F) Type T Thermocouple Input, Range : -86 to 350°C (-123 to 662 , -386-TC, Thermocouple-to-analog converter in °C, type T, $131. K -19 Omega Engineering , OMEGA WHITE BOX® PRODUCT Specifications Ranges: J: -105 to 750°C (-157 to 1382°F) K : -20 to , /°C Input Connection: Miniature thermocouple connector type , SMP Output Connection: standard


Original
PDF TAC-386 TAC-386 TAC-386-J( TAC-386-K( TAC-386-T( MN1604 TAC-386-TC,
2002 - Not Available

Abstract: No abstract text available
Text: Pressure: 150% of rated range , no damage ELECTRICAL CHARACTERISTICS Sensor Type : Bonded strain gage, 4 , 125 = $995. 10 FT. (3m) LONG THERMOCOUPLE CABLE OMEGA MATING CONNECTOR WK6-21C-1/4 , CX340-10K 3.05 m (10') TYPE K Armored Cable-Mating Connector/Spade Lugs CX340A-10 3.05 m (10') NONE CX340A-10J 3.05 m (10') TYPE J CX340A-10K 3.05 m (10') TYPE K WK6-21C-1/4 Mating Connector , . (Also available to be Dynisco compatible) Insulation Resistance: 100 MΩ @ 50 Vdc Thermocouple


Original
PDF CX340-10 CX340-10J CX340-10K CX340A-10 CX340A-10J CX340A-10K WK6-21C-1/4 B-218 WK6-21C-1â
2002 - Not Available

Abstract: No abstract text available
Text: assembly can be quickly assembled for fast delivery. Popular Type K Thermocouple Elements Shown Above , length required. Temperature limitation is by type of thermocouple material selected. A-18 Omega , °C (2200°F) ߜ Available In Type K , E and J Calibrations OMEGA® Nextel Ceramic Insulated Thermocouples , . Consult sales for additional information. Type J Thermocouple Element Shown in Thermowell , lengths available) AWG Wire Size Type K Price Price Add'I Type E Price Price Add'l Type J


Original
PDF XC-14-K-12 XC-14-E-12 XC-14-J-12 XC-20-K-12 XC-20-E-12 XC-20-J-12 XC-24-K-12 XC-24-E-12 XC-24-J-12
2002 - Thermocouple Type L

Abstract: No abstract text available
Text: °C to 1000°C Scaling charge *Insert J, K ,T,E,R or S for thermocouple type . Each unit supplied with , transmitters feature dip switch selection of input type and range . The following models are available: TX901 , -2 251 TX-SCALED 45 J, K , T, E, R, S thermocouple input, non-isolated J, K , T, E, R, S thermocouple input, isolated 100 Ω Pt RTD input (a = 0.00385), non-isolated Range : -150°C to 500°C (-238 , input simulation required to scale output for a particular range . To order unit scaled by OMEGA specify


Original
PDF TX900 225mm 345mm TX903 TX901 TX903 TX901, TX901 Thermocouple Type L
2002 - Not Available

Abstract: No abstract text available
Text: Standard Style 1 2 3 Thermocouple Type Length mm (inches) K E T K E T J K E T , of Error" grade thermocouple materials in " K ", "E" and "T" calibrations and yield accurate , error thermocouple wire. It should be used where extremely fast response is not essential. OMEGA , application instruction sheet accompanies each packaged Cement-On type thermocouples. STYLE 2 OMEGA , ") Foil and 0.25 mm (0.010") Diameter Thermocouple Wire ߜ Very Low Thermal Inertia ߜ Four


Original
PDF
1999 - Not Available

Abstract: No abstract text available
Text: Excitation: 1 mA Thermocouple Input Types and Ranges Type Input Range Low, °F (°C) K J T E R , manual. *Specify thermocouple type J, K ,T,E,R,S, or B. Ordering Example: DRA-TCI-2-J DIN rail 2-wire J , low ripple current. Model DRA-TCI-2 is available for thermocouple types J, K , T, E, R, S or B and , g Model DRA-TCI-2 Input: Thermocouple types J, K , T, E,R,S,B (see thermocouple input types and , change (±3°C for types R and S) Accuracy (Including Linearity): ±0.08% of span for type K , Â


Original
PDF wir32 DRN-PS-1000 DRN-PS-1000
2002 - Not Available

Abstract: No abstract text available
Text: )-(4) T/C 3.4 mm (0.135") 8.50 5 N/C 2 5 7 N/A (1) Thermocouple Type : J, K , for RSCM 4.2 mm (.165") Dia for RSC ߜ J, K , T and E Thermocouple Calibrations and 3 , Insulation: TPE (Thermoplastic Elastomer) Calibrations: ANSI type J, K , T, E and 3-wire copper for RTD’s , Type Available Terminations Style 0 1 inch Trimmed Ends Standard 6 Style 7 OMEGA OTP-M , Example: RSC-K-2-1-2 calls for a 2 foot long, Type K retractable sensor cable with spade lugs on one end


Original
PDF
2002 - Not Available

Abstract: No abstract text available
Text: Intervals from 1000°F to 2440°F (538°C to 1338°C) Limits of Error for Type K & N Thermocouple Wire T/C Temperature Range Limit of Error* Type °C (°F) Standard Special K N 0 to 1250 (32 to , ELIMINATES HIGH TEMPERATURE DRIFT A il bl i T K T N C Typical OMEGACLAD® XL Type K , SIZES IN STOCK FOR FAST DELIVERY! [*] Insert Wire Calibration TYPE K or TYPE Sheath , [*] Insert " K " for Type K Cable or "N" for Type N Cable, [*] Insert Length in Feet for Imperial Models or in


Original
PDF XL-K-MO-125-250, 50/ft 250ft 0mm-100,
1999 - Not Available

Abstract: No abstract text available
Text: ; thermocouples attach directly to on-board screw-terminals Thermocouple Types: J, K , S, T, E, B, R, N Type Range (°C) J K T E N28 N14 S R B -200 to 760 -200 to 1260 -200 to 400 -270 to 1000 , On-Board ColdJunction and Offset-Drift Compensation ߜ Supports type J, K , S, T, E, B, R and N , maximize A/D resolution based on the type of thermocouple attached to the channel being measured , OMB-DBK19 MADE IN USA 14-Channel High-Accuracy Thermocouple Expansion Card for Use with


Original
PDF OMB-DBK19 14-Channel OMB-DBK19 16-bit
2002 - Not Available

Abstract: No abstract text available
Text: (0.065"). The HYP-0, HYP-1 and HYP-2 have type T (CopperConstantan) thermocouple elements, while the , result in an extremely small type T (CopperConstantan) thermocouple being implanted in a 33 gage, 25 mm , ® coated, 36 AWG leads with an SMP type subminiature connector. Thermocouple Probe Model HYP-1 OMEGA , range is cryogenic to 200°C (400°F). This is a type “T” 38 (1.5) 22 (0.87) 22 (0.87 , Hypodermic and Mini Hypodermic Probes Thermocouple and RTD Elements All probes were designed


Original
PDF HYP4-16-11â 2-100-EU-48-RP HYP1-30-1â 2-T-G-60-SMP-M,
1999 - alpha POTENTIOMETERS

Abstract: No abstract text available
Text: ) Accuracy (Including Linearity): ±0.08% of span for type K , ±0.1% to ±0.2% for other thermocouple , resistance Sensor Excitation: 1 mA Thermocouple Input Types and Ranges Type Input Range Low °F (°C) Input Range High °F (°C) Min Span °F (°C) K J T E R S B 32 (0) 32 (0) 32 (0) 32 , thermocouple type J, K ,T,E,R,S, or B. Ordering Example: DRA-TCI-2D-J DIN rail 2-wire J thermocouple input , Back-Lit Loop Powered Display Model DRA-TCI-2D is available for thermocouple types J, K , T, E, R, S


Original
PDF Pt-100 DRN-PS-1000 DRN-PS-1000 alpha POTENTIOMETERS
2002 - Not Available

Abstract: No abstract text available
Text: Section A CL20 Series Temperature Measurement and Calibration Range Input Type K J T E N B R , Input Devices Beaded Wire Probe Belt Clip TA4F RTD Adaptor Type J, K , T, E Thermocouple , adaptor. CL23A does not include type E thermocouple , adaptor or cable. Ordering Examples: CL24 J/ K /T/E , limits. There is also a manual ramp function. No matter what thermocouple type is used, one of these , ', retractable, expands to 10', SMP to spade lug * Insert type (J, K , T, E, R/S, N or mV) * Insert type (J, K


Original
PDF CL23A
2002 - Not Available

Abstract: No abstract text available
Text: : screw terminal Cold Junction Compensation: automatic Thermocouple Types: factory set for type K * Thermocouple Range : Type K :-260°C to 1370°C; J:-200°C to 1190°C; T:-260°C to 390°C; E:-260°C to 990 , OM-CP-RFC101 $249 199 OM-CP-BAT101 12 Wireless temperature transmitter, K * type TC Windows , battery * Contact Omega for other thermocouple types. Operator's manual, RS-232 cable and receiving , OM-CP-RFTC4000 Wireless Thermocouple Temperature Transmitter Part of the NOMAD Family Â


Original
PDF OM-CP-RFTC4000 OM-CP-RFTC4000 meCP-RFTC4000 OM-CP-RFC101 OM-CP-BAT101 RS-232 OM-CP-RFC101 OM-CP-RFTC4000-CERT
2001 - Not Available

Abstract: No abstract text available
Text: -0-800C transmitter calibrated for type K thermocouple with range of 0 to 800°C, TX-SCALED, scaling charge, $109 + , ) TX250 Thermocouple Input Specifications Input: TX251: thermocouple type K , T, J TX252: thermocouple type E TX253: thermocouple type R, S Calibration: Two “Zero” DIP switches, three “Span” DIP , Thermocouple Heads Shown in Section B. $109 109 109 109 45 Transmitter for J, K , T type , by OMEGA order as follows: TX251-(1)-(2)-(3) where (1) is input type , (2) is low end of range , (3


Original
PDF TX250 TX251- TX251-K-0-800C
1999 - Not Available

Abstract: No abstract text available
Text: œ Provides Fourteen Thermocouple-Inputs Via Convenient Thermocouple Connectors ߜ Supports Type J, K , S , thermocouple jacks. To ensure precise measurements over a wide range of operating temperatures, two of the , thermocouple couplings Power: 20 mA Thermocouple Types: J, K , S, T, E, B, R and N Inputs: 14 differential , Range (°C) J K T E N28 N14 S R B -200 to 760 -200 to 1260 -200 to 400 -270 to 1000 , OMB-LOGBOOK, OMB-DAQBOOK and DAQBOARD MADE IN USA OMEGA SM CARE Extended Warranty Program


Original
PDF OMB-DBK52 14-Channel OMB-DBK52 16-bit
2002 - Not Available

Abstract: No abstract text available
Text: thermocouple for stationary surface measurements. Type K thermocouple , 25 to 80°C (80 to 180°F ) range , between -17 to 650°C (0 to 1200°F). The probe is available in a type K thermocouple output, with an , Number) Model Number OS-88000- K -1200 Price $199 Description Infrared thermocouple , Type K , Type K Thermometer ߜ Fast 80 msec Response Time ߜ Hermetically Sealed Optics APPLICATIONS â , on a typical thermocouple meter is provided for the full temperature range . In addition, a


Original
PDF OS-88000-K-1200 OS-88001-K-140F, C/440Â C/340Â C/280Â C/240Â C/180Â C/140Â
2002 - Not Available

Abstract: No abstract text available
Text: Range ® OMEGA 400 -140 to 217°F Thermistor -250 to 103°C K T General Purpose Meter , -(*)-30-36, $15 * lnsert thermocouple type , J, K ,T,E Accessories Model No. SC-450S SC-450L Price , IN STOCK FOR FAST DELIVERY Model 450-AJT Input Type J Range 179.4 to 398.3°F - 318 to 1858°F -117.4 to 203.5°C -194 to 1014°C IronConstantan Model 450-AKT Input Type Range -219.7 , -AET Input Type Range -215.0 to 398.4°F -351 to 1844°F ® CHROMEGA -137.2 to 203.5°C Constantan 212


Original
PDF 450-AJT 450-AKT 450-AET 450-ATT 450-ATH 450-APT 450-AJT, SC-450S
2003 - Not Available

Abstract: No abstract text available
Text: communications. 9 Thermocouple Types The DP41-B handles NINE (9) thermocouple types: K , J, T, E, R, S, B, N , (2) 3 A relays Form-C, SPDT Input Type Sensor Type J Iron Constantan K * Chromel Alumel T , °C 0.3°F 0.2 K 0.6°C 1.0°F 0.6 K Range Accuracy* -200 to 200°C -328 to 392°F 73.2 to , ±) Maximum Linearization Error * For Type K : Temperatures over 1250°C, accuracy will be 0.4°C/0.8 , Thermocouple Input Types: J, K , T, E, R, S, B, N, J DIN RTD Input: any 6 ohm to 6 kohm NIST or DIN platinum


Original
PDF DP41-B RS-232/RS-485 DP41-B. DP40B-R) DP40B-A) RS-232
2002 - Not Available

Abstract: No abstract text available
Text: that accepts J, K and T thermocouple types. From the front panel, the user can select the thermocouple , thermocouple type , resolution, and temperature units are stored in non-volatile memory so you don’t have to , K Inputs ߜ 0.1 Resolution in °F and °C Over Full Range ߜ High 0.1% Reading Accuracy ß , , beaded wire type K probe (for each input), integral tilt stand/handle, wrist strap, rubber holster , indicators for thermocouple type °C/°F units, hold and low battery; HH-22 and HH-23 have additional


Original
PDF HH-20 HH-21 HH-21 HH20-R) HH-22, SC-450L HH22-AC MN1604 HH20CAL
2002 - Not Available

Abstract: No abstract text available
Text: Section I for additional probe calibration information. Ordering Example: KQIN-14-G-12-CL5, type K quick , ) OMEGA 's hot pointTM Thermocouple and RTD Calibrator Calibrates All Temperature Sensors to Within  , calibration points as shown in the reference chart below by thermocouple type . Ordering Information , OMEGA standard size low noise thermocouple , type-K calibration, 1⁄4" O.D. stainless steel sheath , °C (787°F) Melting Point of Zinc 420°C (787°F) Types J, K , E and N A-29 P.S.! OMEGA


Original
PDF
1998 - Not Available

Abstract: No abstract text available
Text: ® Temperature Recorder will work with any type J or K thermocouple probe. For more information on , max. Thermocouple Inputs: ANSI type J and K Thermocouple Source Impedance: 1000 Ω max Cold , Thermocouple Inputs J and K Electronic Linearization Temperature Accuracy 1.5% F.S. Millivolt Inputs 1 mV to , measurement of temperature and process signals. Modules are available for J or K type thermocouples. A , representative for full details when placing an order. 1-Channel ICSS-316G-12, Type J, Thermocouple Quick


Original
PDF 640-2-MV-MV, E-313 E-314 SL-301 SL-302 SL-303 50/cm/s