The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1394CMS8#PBF Linear Technology LT1394 - 7ns, Low Power, Single Supply, Ground-Sensing Comparator; Package: MSOP; Pins: 8; Temperature Range: 0°C to 70°C
LT1671CMS8#TRPBF Linear Technology LT1671 - 60ns, Low Power,Single Supply, Ground-Sensing Comparator; Package: MSOP; Pins: 8; Temperature Range: 0°C to 70°C
LT1394IS8 Linear Technology LT1394 - 7ns, Low Power, Single Supply, Ground-Sensing Comparator; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C
LT1671IS8#TR Linear Technology LT1671 - 60ns, Low Power,Single Supply, Ground-Sensing Comparator; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C
LT1394CMS8#TR Linear Technology LT1394 - 7ns, Low Power, Single Supply, Ground-Sensing Comparator; Package: MSOP; Pins: 8; Temperature Range: 0°C to 70°C
LT1671IS8 Linear Technology LT1671 - 60ns, Low Power,Single Supply, Ground-Sensing Comparator; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C

Neutral grounding resistor Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2015 - NGRM-ENC-200-01

Abstract: NGRM-ENC-000-01
Text: Protection Relays & Controls Neutral Grounding Resistor Monitoring NGRM-ENC SERIES NGRM-ENC , -B-030515 Protection Relays & Controls Neutral Grounding Resistor Monitoring NGRM-ENC SERIES NGRM-ENC Ordering , generator neutral-to-ground connection and continuity of the neutral-grounding resistor . SE-330 Neutral-Grounding-Resistor Monitor Advanced ground-fault and neutral-grounding resistor monitoring relay that measures neutral current, neutral-to-ground voltage, and neutral-toground resistance. Simplified Circuit


Original
PDF SE-325 SE-330 480/600-V EL3100 SE-330HV NGRM-ENC-200-01 NGRM-ENC-000-01
2012 - Not Available

Abstract: No abstract text available
Text: 1A NOTE 1 NEUTRAL GROUNDING RESISTOR AL AH BL BH CL CH L 120 V LAMP , 1A NEUTRAL GROUNDING RESISTOR 1A 1A PT’S NOTES 1&2 L NOTES: 1. 120/√3 OR 240


Original
PDF SE-EPI-06 SE-EPI-06 1-800-TEC-FUSE SE-EPI-06-M S95-EPI0-00000 MIL-1-46058 SE-EPI-06-M,
2010 - Not Available

Abstract: No abstract text available
Text: Token’s Oval Edge-Wound DOE, and Power-Wound DST resistor elements. Neutral Grounding Resistor A suitably rated power resistor that is connected between the neutral of a transformer (or generator) and , leading technology for power resistor needs. The most critical drawback with this technology is that it is inherently inductive. This is logical given that a wirewound inductor and a wirewound resistor , method greatly reduces the inductance of any given resistor size and value combination, however it does


Original
PDF
2010 - types of resistors

Abstract: Neutral grounding resistor Light-sensitive Alarm Project resistor carbon composition applications of Light-sensitive Alarm nichrome thin film heater "Silicon Controlled Rectifier" Variable Resistors carbon film photoresistors token carbon film resistor
Text: will damage electrical circuit system and components. By installing a neutral grounding resistor , the , TCR's and the ability to give a long drift free service. Neutral Grounding Resistors Neutral grounding resistors are incorporated into electrical circuits to protect the system and devices. Neutral , TOKEN What is a Resistor What is a Resistor Preview Resistor is electrical or electronic components which resist the flow of current across the resistor


Original
PDF
Neutral grounding resistor

Abstract: RXPE 40 RK511 directional static overcurrent relay Boveri voltage regulator HB relay asea directional relay RXPE ASEA brown boveri protection relay ABB/Neutral grounding resistor BROWN BOVERI protection relay
Text: with a neutral grounding resistor or reactor, directional protection for active or reactive power in


OCR Scan
PDF B03-3010 B03-9301E B03-3003E B03-3020E B03-9312E B03-9382E RK511-300E Neutral grounding resistor RXPE 40 RK511 directional static overcurrent relay Boveri voltage regulator HB relay asea directional relay RXPE ASEA brown boveri protection relay ABB/Neutral grounding resistor BROWN BOVERI protection relay
2009 - Lodtrak III

Abstract: Lodtrak IV PGC5000 MANUAL multilin 169 multilin 369 WESTINGHOUSE motor life line multilin 269 Neutral grounding resistor delta plc cable pin diagram RS-232 DC UNGROUNDED EARTH FAULT detector circuit using
Text: monitoring, and resistor monitoring. GROund Fault PROtectiOn ReSiStance GROundinG MP MOtOR , Continuity Monitor 21 PGM-8325 Neutral Grounding Monitor 22 PGM-8600 (GFR4001-IM) Insulation , of your electrical system. Ground Fault Relays Resistance Grounding Systems Motor Protection , GROUNdING RESISTORS Failed resistors due to corrosion or loose connections RG SM GFP RG , moisture, vibration, chemicals and dust without the nuisance trips. RG Resistance Grounding


Original
PDF
1992 - grounding transformer

Abstract: IEEE Std 242-1986 Broken Conductor Detection for Overhead Line Distribution System westinghouse transformer 480 transformer SURGE ARRESTER abstract online ups service manual delta westinghouse surge arrester NEC 2505 nj Neutral grounding resistor WESTINGHOUSE motor life line TYPE A frame 184
Text: Institute Abstract: The problems of system grounding , that is, connection to ground of neutral , of the , the system should be grounded, and how to select equipment for the grounding of the neutral circuits , . 3 1.4 Methods of System Neutral Grounding . 4 1.5 Grounding at Points Other than System Neutral , Figure 1- Grounding Systems 1.4 Methods of System Neutral Grounding 1.4.1 Introduction Most grounded


Original
PDF
2012 - Westinghouse dc motor type sk

Abstract: Lodtrak IV M4200 Westinghouse SCR handbook M2000-200 SCR generators winding circuit diagrams t7900 Lodtrak III westinghouse mip 836 ic
Text: T2200 T2300 T2400 T2500 T2700 T2900 T3000 T3100 T3300 3 Resistance grounding /Ngr , . High-resistance grounding eliminates the Arc-Flash hazard associated with the first ground fault, transient , Insulation breakdown due to vibration and corrosion Ground Fault (pg 18) Resistance Grounding (pg 34) Arc-Flash (pg 56) TRANSFORMERS Overloading and overvoltage Resistance Grounding (pg 34) Feeder (pg , (pg 41) Feeder (pg 52) Resistance Grounding (pg 34) Arc-Flash (pg 56) Switchboards &


Original
PDF PF130N Westinghouse dc motor type sk Lodtrak IV M4200 Westinghouse SCR handbook M2000-200 SCR generators winding circuit diagrams t7900 Lodtrak III westinghouse mip 836 ic
2015 - Neutral grounding resistor

Abstract: No abstract text available
Text: . High-impedance grounded neutral systems in which a grounding impedance, usually a resistor , limits the , is a neutral grounding device. The Sleuth limits ground fault current to non-destructive levels , high-impedance grounding neutral systems up to 1000 V AC where the ground fault current is limited to 5 amperes , neutral systems shall comply with provisions (a) through (f): a) Grounding Impedance Location: The grounding impedance shall be installed between the grounding electrode conductor and the system neutral


Original
PDF C-408EM Neutral grounding resistor
2011 - ammeter

Abstract: No abstract text available
Text: add high resistance grounding to an ungrounded delta-connected system, a neutral point must be , provide such a neutral point. The transformers and grounding resistors are chosen to limit the ground , charging level will flow. As all ground current must flow through the grounding resistor / grounding , 37 41 1 Pulsing Resistor 4 59 C AM Pulsing Resistor 3 5A Grounding , Tap 4 3A 1 Secondary Circuit Breaker Grounding Resistor 32 B CT 10/10 A


Original
PDF CA08104001E 6451A 16451B ammeter
2014 - Not Available

Abstract: No abstract text available
Text: resistor @ 5% tolerance across the Neutral Plug and Ground Plug. The PASS LED should remain , Neutral Plug and Ground Plug. The FAIL LED should remain illuminated until the resistor is removed , Strap Tester to fulfill the S6.1 Section 6.3.1 requirement. “The hot, neutral , and equipment grounding conductor shall be verified to be in the proper wiring orientation in accordance with the National Electric Code (ANS/NFPA-70).” ( Grounding ANSI/ESD S6.1 section 6.3.1 Equipment Grounding


Original
PDF TB-2099 ANS/NFPA-70) TB-2099
2011 - Not Available

Abstract: No abstract text available
Text: . “The hot, neutral and equipment grounding conductor shall be verified to be in the proper wiring , Connect a 12.5 kilohm resistor @ 5% tolerance across the Neutral Plug and Ground Plug. The FAIL LED , Maintenance Made in America more than just a few volts between ground and neutral , this indicates , alarm and display a red FAIL indication and should not be used for an ESD grounding point until , Calibration Features and Components Neutral Figure 2. Desco 19224 Ground Hub Continuous Monitor Load


Original
PDF TB-3049â TB-3049
2014 - Not Available

Abstract: No abstract text available
Text: Grounding Resistors (NGR), High-Current Grid Resistors KEY BENEFITS • Neutral ground resistors offer , Reliable Neutral Grounding Resistors, • Custom design on demand www.vishay.com • Material , www.vishay.com/doc?99912 Reliable Neutral Grounding Resistors, High Current Grid Resistors APPLICATIONS OF NEUTRAL GROUNDING ( NEUTRAL EARTHING) FEATURES C Vishay Milwaukee offers a complete line of custom and standard • Tied live design resistors there are no known as neutral grounding so that (NGRs), also


Original
PDF IP23-rated 02-Oct-14 VMN-PT0441-1412
5 MVA generator

Abstract: 1 MVA generator 50 mva transformer 20 MVA generator ASEA ragea protection relay 10 MVA generator 2.5 MVA transformer ragea Neutral grounding resistor transformer 2 mva
Text: €¢ Monitors integrity of the neutral grounding and associated wiring • As little as 1 % generator third-harmonic voltage used to provide full protection • Filtered fundamental frequency neutral voltage used to , most generators and large transformer-connected motors which have a neutral connection available and are not solidly grounded. The RAGEA also detects short or open circuits in the grounding or in the neutral voltage circuits. The relay is applied to provide the conventional ground-fault protection for


OCR Scan
PDF B03-4012 B03-4012E B03-1003E B03-1215E B03-2032E B03-2034E B03-2534E B03-1613E B03-9301E S-721 5 MVA generator 1 MVA generator 50 mva transformer 20 MVA generator ASEA ragea protection relay 10 MVA generator 2.5 MVA transformer ragea Neutral grounding resistor transformer 2 mva
2012 - Neutral grounding resistor

Abstract: SE-CS30-70 SE-CS30 EFCT-26
Text: Protection Relays Neutral Grounding NGR Series Neutral-Grounding-Resistor System Description Neutral-Grounding Resistors (NGRs) are used to ground power systems by inserting a resistor between the system neutral and ground. This lowers the prospective ground-fault current to a predetermined , current can flow, allowing it to be detected and measured. Also, because a resistor is used to ground the , ability to quickly locate or isolate the fault. Applications Resistance grounding is typically applied


Original
PDF CT200 EFCT-26 SE-CS30-26 SE-CS30-70 SE-325, SE-330, SE-701 Neutral grounding resistor SE-CS30-70 SE-CS30
2013 - Not Available

Abstract: No abstract text available
Text: Protection Relays & Controls Neutral Grounding NGR Series Neutral-Grounding-Resistor System Description Neutral-Grounding Resistors (NGRs) are used to ground power systems by inserting a resistor between the system neutral and ground. This lowers the prospective ground-fault current to a , groundfault current can flow, allowing it to be detected and measured. Also, because a resistor is used to , coordination and the ability to quickly locate or isolate the fault. Applications Resistance grounding is


Original
PDF EFCT-26 CT200 SE-CS30-26 SE-CS30-70 SE-325, SE-330, SE-701
2013 - Not Available

Abstract: No abstract text available
Text: Protection Relays & Controls Neutral Grounding NGR Series Neutral-Grounding-Resistor System Description Neutral-Grounding Resistors (NGRs) are used to ground power systems by inserting a resistor between the system neutral and ground. This lowers the prospective ground-fault current to a , groundfault current can flow, allowing it to be detected and measured. Also, because a resistor is used to , coordination and the ability to quickly locate or isolate the fault. Applications Resistance grounding is


Original
PDF EFCT-26 CT200 SE-CS30-26 SE-CS30-70 SE-325, SE-330, SE-701
2015 - mrc412

Abstract: NGR8
Text: OF NEUTRAL GROUNDING ( NEUTRAL EARTHING) Vishay Milwaukee resistor offers a complete line of custom and standard neutral grounding resistors (NGRs), also known as neutral earthing resistors (NERs). Milwaukee resistor neutral grounding resistors are designed to absorb a large amount of energy without exceeding temperature limitations defined in IEEE-32. These resistors are used for grounding of generators , NGR www.vishay.com Vishay Milwaukee Reliable Neutral Grounding Resistors, High Current Grid


Original
PDF 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12 mrc412 NGR8
2013 - IRDH275

Abstract: TBP103005 IRDH575
Text: ) Terminating resistor Device address, BMS bus 22 internal/external ≤ 10 m 400 μA (≤ 12.5 kΩ) 20 , Connection Cable length Cable (twisted in pairs, one end of shield connected to PE) Terminating resistor , shield connected to PE) Terminating resistor Switching elements Switching components Operating


Original
PDF ZT1590 ZT1590RS ZT1591 ZT1591RS ZT1594RS NAE4003010 IRDH275 TBP103005 IRDH575
2001 - Leakage Current

Abstract: No abstract text available
Text: the absence of a grounding connection, it is the current that could flow from any conductive part or , IMPORTANT? Electrical equipment commonly includes a grounding system to provide protection against a shock hazard if there is an insulation failure. The grounding system usually consists of a grounding conductor , hazard. Obviously, a possible shock hazard exists if the grounding connection is interrupted, either , flowing in the ground conductor is measured by connecting the meter in series with the grounding


Original
PDF AN-113 IEC601-1, UL2601-1 Leakage Current
2010 - Not Available

Abstract: No abstract text available
Text: , pulp and paper, petroleum, and water-treatment facilities. RESISTANCE GROUNDING RELAY Resistor , advanced ground-fault and groundingresistor-monitoring relay. It measures neutral current, neutral-toground , path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance , determine that the NGR is intact. It is able to detect a resistor failure with or without a ground fault , adjustable-speed drives do not occur. Should the resistor open and a ground fault subsequently occur, the PGR


Original
PDF PGR-5330 PGA-0500 10-event RS-232
ac voltage regulator using SCR circuit diagram

Abstract: 220v AC voltage regulator schematic diagram schematic diagram ac 220v voltage regulator 220v AC to 120v AC circuit diagram scr gate driver ic rv4144n scr Power Supply Schematic Diagram rv4143n RV4143 ac circuit breaker using SCR
Text: neutral fault detection Meets U.L. 943 standards Connection Information 8-Lead Dual In-Line Package , controllers for ac outlet ground fault interrupters. These devices detect hazardous grounding conditions, such , relay the 4143 or 4144 will detect and protect against both hot wire to ground and neutral wire to , the value of an internal resistor . When the output of the op amp swings above 3/4Vs or below 1/4Vs the SCR trigger output will go high and fire an external SCR. Grounded neutral fault detection is accom


OCR Scan
PDF RV4143 RV4143, RV4144 820pF 300juA. ac voltage regulator using SCR circuit diagram 220v AC voltage regulator schematic diagram schematic diagram ac 220v voltage regulator 220v AC to 120v AC circuit diagram scr gate driver ic rv4144n scr Power Supply Schematic Diagram rv4143n ac circuit breaker using SCR
2004 - ac voltage regulator using SCR circuit diagram

Abstract: schematic diagram ac 220v voltage regulator 3 pin SCR PIN CONFIGURATION 220v AC voltage regulator schematic diagram SCR PIN CONFIGURATION SCHEMATIC circuit scr regulator scr gate driver ic scr Power Supply Schematic Diagram scr firing circuit ac regulator pin diagram of SCR
Text: hazardous grounding conditions, such as equipment (connected to opposite phases of the AC line )in contact , detect and protect against both hot wire to ground and neutral wire to ground faults.Ease of application , interface to SCR *Supply voltage derived from AC line-26V shunt *Adjustable sensitivity *Grounded neutral , pin7 relative to pin 3, RSENSE is the value of the feedback resistor connected from pin 7 to pin 1 , neutral fault detection is accomplished when a short or fault closes a magnetic path between the sense


Original
PDF RV4145A RV4145A QW-R122-006 ac voltage regulator using SCR circuit diagram schematic diagram ac 220v voltage regulator 3 pin SCR PIN CONFIGURATION 220v AC voltage regulator schematic diagram SCR PIN CONFIGURATION SCHEMATIC circuit scr regulator scr gate driver ic scr Power Supply Schematic Diagram scr firing circuit ac regulator pin diagram of SCR
2012 - GROUND Fault MONITORING CIRCUIT

Abstract: Neutral grounding resistor
Text: systems by inserting a resistor between system neutral and ground to lower the ground-fault current to a predetermined value. Properly sized Resistance Grounding Systems solve two problems of ungrounded , Protection Relays Pulsing High-Resistance Grounding PGN series Pulsing , Grounding Systems include all necessary components to convert to a resistance grounded system. Options , . Applications High-resistance grounding is typically applied on transformers and generators where safety and


Original
PDF SE-330 GROUND Fault MONITORING CIRCUIT Neutral grounding resistor
2013 - Not Available

Abstract: No abstract text available
Text: systems by inserting a resistor between system neutral and ground to lower the ground-fault current to a predetermined value. Properly sized Resistance Grounding Systems solve two problems of ungrounded , Protection Relays & Controls Pulsing High-Resistance Grounding PGN series Pulsing , Grounding Systems include all necessary components to convert to a resistance grounded system. Options , . Applications High-resistance grounding is typically applied on transformers and generators where safety and