The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1332CNW Linear Technology Wide Supply RangeLow Power RS232 Transceiver with 12V VPP Output for Flash Memory
LT1332CNW#PBF Linear Technology Wide Supply RangeLow Power RS232 Transceiver with 12V VPP Output for Flash Memory
LTC4416IMS-1#TR Linear Technology IC 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, PLASTIC, MSOP-10, Power Management Circuit
LTC2913CMS-2#TR Linear Technology IC 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, PLASTIC, MSOP-10, Power Management Circuit
LTC2913HMS-2#TR Linear Technology IC 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, PLASTIC, MSOP-10, Power Management Circuit
LTC2900-1CMS#TRPFB Linear Technology IC 4-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, PLASTIC, MSOP-10, Power Management Circuit

Nemic-Lambda power supply unit Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
Nemic-Lambda power supply unit

Abstract: Nemic-Lambda
Text: carefully, before using the power supply unit . =NOTES= *1. At 100/200VAC, Ta=25°C and maximum output power , using the power supply unit . =NOTES= *1. At 100/200VAC, Ta=25°C and maximum output power . *2. For , Maximum Output Power W 67 75 76 77 79 79 Efficiency (Typ) (*1) % 85 ~ 265VAC (47 ~ 63Hz) or 120 , Power Factor (100/200VAC)(Typ) (*1) 10.8~13.2 13.5~16.5 21.6~26.4 43.2~52.8 Output Voltage Range V , (%) is percent of maximum output power or maximum output current, whichever is greater. - As for


Original
PDF A159-01-01A JWS100 265VAC 330VDC 100/200VAC) Nemic-Lambda power supply unit Nemic-Lambda
zup series

Abstract: GP485A Nemic-Lambda GmbH 800w inverter ZUP6-66 ZUP6-33 ZUP10-80 ZUP10-40 Nemic-Lambda users LAMBDA zup
Text: Line Up Power Supply Identification / Accessories Output Voltage Output Current (A) (W , 1 ZUP Configurations BENCHTOP POWER SUPPLY Single Parallel ( Master / Slave ) PARALLEL , _ +1 Note 1 External Control Connector 30.0 21.5 19.0 +V POWER SUPPLY -V , -M-PE Plug PHOENIX: PSC 1,5/3-3-F Plastic cable housing Included with the power supply . Rubber Bumpers , pins AMP, 87523-6. Included with the power supply . IEC320 AC Inlet 22.0 DIMENSIONS


Original
PDF 1-800-LAMBDA-4 00W/400W/800W AD0807-B zup series GP485A Nemic-Lambda GmbH 800w inverter ZUP6-66 ZUP6-33 ZUP10-80 ZUP10-40 Nemic-Lambda users LAMBDA zup
JWS120P-24

Abstract: JWS120P-48 A181-01-01A
Text: , before using the power supply unit . =NOTES= *1. Operating time at peak output is less than 10sec.(Duty<=0.5) *2. At 100/200VAC, Ta=25°C and average output power . *3. For cases where conformance to various , (at 60Hz). *11. Power Supply will recover in case of lower the temperature. *12. Ratings - Derating , Average Output Current Peak Output Current (*1) Average Output Power Peak Output Power (*1 , ) PFHC Power Factor (100/200VAC)(Typ) (*2) Output Voltage Range Maximum Ripple & Noise 0 ~ +60°C (*4


Original
PDF A181-01-01A 100/200VAC) A181-01-02_ 100VAC. A1810101 A181-01-02 A1810102Pdf JWS120P-24 JWS120P-48 A181-01-01A
800w power inverter circuit diagram

Abstract: Lambda-GP485 neptune digital Energy Meter M8 NC405 Nemic-Lambda power supply unit zup20-40 user manual coutant power supply NEMIC LAMBDA supply Circuit diagram coutant power supply 5V NEMIC-LAMBDA ZUP10-80 Nemic-Lambda power supply unit
Text: rear panel of the power supply , using two self tapping screws supplied with the unit . Refer to Fig , programming of the power supply , is located on the rear panel of the unit ,(Fig. 4-2, item 4). The pin , an electrical ground. The instrument must be connected to the AC power supply mains through a three , power outlet. For instruments designed to be hard - wired to the supply mains, the protective earth , indicators show the complete operating status of the power supply . The front panel controls allow the user


Original
PDF 00W/400W/800W RS232 RS485 ZC-20101, ZUP6-33 ZUP10-20 ZUP20-10 ZUP36-6 ZUP60-3 ZUP6-66 800w power inverter circuit diagram Lambda-GP485 neptune digital Energy Meter M8 NC405 Nemic-Lambda power supply unit zup20-40 user manual coutant power supply NEMIC LAMBDA supply Circuit diagram coutant power supply 5V NEMIC-LAMBDA ZUP10-80 Nemic-Lambda power supply unit
transistor SR60

Abstract: diode SR60 Nemic-Lambda power supply unit Nemic-Lambda SR manual Nemic-Lambda SR 330 manual Nemic-Lambda users Nemic-Lambda ed Nemic-Lambda tog cnt Nemic-Lambda 5v SR20-110
Text: SUPPLY UNIT Pay attention to all warnings and cautions before using the unit . Incorrect usage could lead , . CAUTION # This power supply is primarily designed and manufactured to be used and enclosed in other , power supply terminals and the load terminals. + Output Terminal — Output Terminal PJ1 Pin , when the power supply 's output is in normal operating condition. Î) Connector PJ1-1 :T0G1 -r -2 :TOG2 , to turn the power supply output on and off using an external signal PF Signal Output Terminal In the


OCR Scan
PDF SR110 SR230 SR330 SR660 transistor SR60 diode SR60 Nemic-Lambda power supply unit Nemic-Lambda SR manual Nemic-Lambda SR 330 manual Nemic-Lambda users Nemic-Lambda ed Nemic-Lambda tog cnt Nemic-Lambda 5v SR20-110
Nemic-Lambda sr660-5

Abstract: SR660-12 SR660-28 SR660-24 Nemic-Lambda SR manual 336W Nemic-Lambda sr FAN BLOWER SR660-5 SR660
Text: the power supply unit . DERATING CURVE (5V TYPE) MOUNTING A LOAD (%) =NOTES= *1. At 100V/200VAC and maximum output power . *2. For cases where conformance to various safety specs (UL, CSA, etc , Maximum Output Current (*9) A 132 132 110 74 56 45 37.5 33 28 24 14 3 Maximum Output Power W , dewdrop) 23 Cooling - Forced air by blower fan (Blower fan is mounted within supply ) 24 Temperature , load, constant input voltage. 60 *6. Constant current limiting with automatic recovery. (The unit


Original
PDF SR660 A088-01-01B SR660 Nemic-Lambda sr660-5 SR660-12 SR660-28 SR660-24 Nemic-Lambda SR manual 336W Nemic-Lambda sr FAN BLOWER SR660-5
Nemic-Lambda power supply unit

Abstract: Nemic-Lambda SWS50-5 SWS50 SWS75-5
Text: FG terminal of SWS series to earth terminal of equipment system where power supply unit is mounted , Power Supply Input voltage range is single phase 85 ~ 265VAC ( 47 ~ 63Hz ) or 120 ~ 330VDC. Input , excessively. Method ( B ) Load Power Supply 3-3. Inrush Current Power Thermistor is built in to , increase the Output Current is not possible. Power Supply Output Terminal 3-6. Output Ripple & , NEMIC-LAMBDA SWS 5075100150 Series INSTRUCTION MANUAL (B) Operation as a Backup Power Supply is possible as


Original
PDF SWS50, SWS75 SWS150 SWS100 SWS75, Nemic-Lambda power supply unit Nemic-Lambda SWS50-5 SWS50 SWS75-5
Nemic-Lambda power supply unit

Abstract: 150B VS150B
Text: carefully, before using the power supply unit . =NOTES= *1. Operating time at peak output current is less than 10sec with average output power . ( Duty : 0.35 ) *2. At 100VAC and average output power , Ta , Average Output Power W 118.8 180 180 180 184 181.44 181.44 184.32 6 Peak Output Power (*1) W 72 , ( average power ), constant input voltage. *7. From -10 - +50°C, constant input voltage and load. *8


Original
PDF PA523-01-01B VS150B VS150B 132VAC Nemic-Lambda power supply unit 150B
CSA950

Abstract: No abstract text available
Text: Drawing ) 30 Size (WxHxD) *Read instruction manual carefully, before using the power supply unit . =NOTES= *1. At 100VAC and maximum output power , Ta=25°C. *2. For cases where conformance to various , Current Maximum Output Power Efficiency (Typ) Input Voltage Range Input Current (Typ) Inrush Current , . At 100VAC or 200VAC & maximum output power . *4. Typical value on cold start, Ta=25°C. *5. From 85


Original
PDF PA761-01-01C CSA950
Nemic-Lambda tog cnt

Abstract: Nemic-Lambda sws600 Nemic-Lambda tog Nemic-Lambda power supply unit viore Nemic-Lambda users nemic lambda tog cnt Nemic-Lambda 5v SWS600-24 SWS600
Text: circuit is in the secondary (output) side of the power supply unit . Do not connect in the primary (input , , connect the FG terminal of SWS series to earth terminal of equipment system where power supply unit is , NEMIC-LAMBDA INSTRUCTION MANUAL SWS 600 _Instruction Manual_ BEFORE USING THE POWER SUPPLY , from it; you may get injured by an accident. • This power supply is primarily designed and , must not be user accessible. • This power supply has a possibility that hazardous voltage may occur


OCR Scan
PDF
Nemic-Lambda power supply unit

Abstract: Nemic-Lambda CN RWS15A 110-330VDC RWS15A-5 RWS15A-48 RWS15A-24 RWS15A-15 RWS15A-12 JHTR5904
Text: MANUFACTURER : MOLEX 2 of 4 NEMIN - LAMBDA INSTALLATION 1 TO MEET SAFETY REQUIREMENTS, THE POWER SUPPLY , penetrate into the power supply more than 6mm from the external surface of the chassis. 3.2 : Whichever , in-between is required for sufficient ventilation. 3.5 : The power supply must be installed where equipment , the output voltage. POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY Fig B Hg. C , 1.3 1.0 0.7 0.3 3 Maximum Output Power W 15.0 15.6 15.0 16.8 14.4 4 Efficiency (Typ) (*1) % 71 75 77


OCR Scan
PDF RWS15A RWS15A-5 RWS15A-12 RWS15A-15 RWS15A-24 RWS15A-48 85-265VAC 440Hz) 110-330VDC Nemic-Lambda power supply unit Nemic-Lambda CN 110-330VDC RWS15A-48 JHTR5904
CSA234

Abstract: KS10-12 KS10-5 pA758
Text: Outline Drawing) * Read Instruction manual carefully, before using the power supply unit . = NOTES = *1. At 100VAC and Maximum Output Power , Ta=25C. Measurement point for Vo, load / line reguration , A 0 0 3 Maximum Output Current A 2.0 0.9 4 Maximum Output Power W 10.0 , . From Min load - Full load (Maximum power ), constant input Voltage. *6. From 0~50°C, constant input


Original
PDF PA758-01-01A KS10-5 KS10-12 100VAC 100VAC, 132VAC 440Hz 175VDC 100MHz CSA234 KS10-12 KS10-5 pA758
GP485

Abstract: zup series nc302 SPS 600 Nemic-Lambda power supply unit 19" rack, 3U height coutant power supply NL100 Nemic-Lambda SPS9600 GP-485
Text: connector pinout 3.10 Connecting GP485 to Zup power supply . pg. 9 , Zup Power Supply 4.13.5 GP485 initialize for using SRQ* 4.14 Parallel poll , an electrical ground. The instrument must be connected to the AC power supply mains through a three , power outlet. For instruments designed to be hard - wired to the supply mains, the protective earth , describing the problem and specifying the owner, model number and serial number of the unit . 3.6 POWER


Original
PDF GP485 GP485 73/23/EEC 89/336/EEC zup series nc302 SPS 600 Nemic-Lambda power supply unit 19" rack, 3U height coutant power supply NL100 Nemic-Lambda SPS9600 GP-485
Nemic-Lambda power supply unit

Abstract: ppd10-24-1212 drawing RC-9002A pa5130 PPD10-5-1515 PPD10-5-1212 Nemic-Lambda power supply unit 5vdc PPD10-12-1212 PA513-01-01A pa513
Text: ) *Read instruction manual carefully, before using the power supply unit . Load (%) =NOTES= 1. At , power supply unit . Load (%) =NOTES= 1. At 12VDC and Maximum total output power . 2. EIAJ RC , carefully, before using the power supply unit . Load (%) =NOTES= 1. At 24VDC and Maximum total output , instruction manual carefully, before using the power supply unit . Load (%) =NOTES= 1. At 48VDC and , +15 -15 2 Maximum Output Current A 0.35 0.35 0.30 0.30 3 Nominal Output Power W 8.4 9.0 4


Original
PDF PPD10-5 PA512-01-01 PPD10-5-1212 PPD10-5-1515 48VDC RC-9002A 100MHz 63VDC, Nemic-Lambda power supply unit ppd10-24-1212 drawing pa5130 PPD10-5-1515 PPD10-5-1212 Nemic-Lambda power supply unit 5vdc PPD10-12-1212 PA513-01-01A pa513
EWS-150

Abstract: Nemic-Lambda ews150 Nemic-Lambda Nemic-Lambda ews EWS150 Nemic-Lambda power supply unit
Text: ) *Read instruction manual carefully, before using the power supply unit . ITEMS Nominal Output Voltage Average Output Current Average Output Power Efficiency Input Voltage Range =NOTES= *1. At 100VAC/200VAC and average output power . *2. For cases where conformance to various safety specs (UL, CSA, etc , ) is percent of average output power or average current, whichever is greater. Refer to instruction


Original
PDF A121-01-01C EWS150 EWS150 EWS-150 Nemic-Lambda ews150 Nemic-Lambda Nemic-Lambda ews Nemic-Lambda power supply unit
T8A250V

Abstract: 800w power inverter circuit diagram NEMIC LAMBDA supply Circuit diagram transistor Arm 3055 equivalent coutant remote control zener diode for 240v ac voltage nc302 coutant power supply 5V Nemic-Lambda CN
Text: the power supply , using two self tapping screws supplied with the unit . Refer to Fig. 1-1 for details , programming of the power supply , is located on the rear panel of the unit ,(Fig. 4-2, item 4). The pin , Values of Toxic and Hazardous Substances/Elements (wt%) ZUP200W/400W/800W POWER SUPPLY SERIES Product , Information Products ". 2.9Kg ZUP200W/400W/800W POWER SUPPLY SERIES Product Weight ZUP200 Part Name As , an electrical ground. The instrument must be connected to the AC power supply mains through a three


Original
PDF 1-800-LAMBDA-4 RS232 RS485 RS232) T8A250V 800w power inverter circuit diagram NEMIC LAMBDA supply Circuit diagram transistor Arm 3055 equivalent coutant remote control zener diode for 240v ac voltage nc302 coutant power supply 5V Nemic-Lambda CN
Nemic-Lambda power supply unit

Abstract: Nemic-Lambda DSR30
Text: Drawing ) 31 Size (WxHxD) *Read instruction manual carefully, before using the power supply unit , Drawing ) 31 Size (WxHxD) *Read instruction manual carefully, before using the power supply unit , : Greater than 2V or open : shutdown, 0V ~ 0.8V : power on. Supply voltage to CNT must not exceed 7V. *7 , : Greater than 2V or open : shutdown, 0V ~ 0.8V : power on. Supply voltage to CNT must not exceed 7V. *7 , Output Voltage Maximum Output Current Maximum Output Power Efficiency (Typ) (*1) Input Voltage Range


Original
PDF DSR30 A072-01-01A Nemic-Lambda power supply unit Nemic-Lambda
EWS1500-5

Abstract: EWS1500 Nemic-Lambda EWS1500 EWS-1500 Nemic-Lambda power supply unit Nemic-Lambda ews Nemic-Lambda users ws150 WS1500 Nemic-Lambda tog cnt
Text: THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit . Incorrect , * When the unit is used as a fixed voltage power supply , the REF and PV terminals should be shorted , connected. * When the unit is used as a fixed voltage power supply , the REF and PV terminals should be , by an accident. CAUTION # This power supply is primarily designed and manufactured to be used and , (Green LED) This indicator turns on when the power supply 's output is in normal operating condition, (fl


OCR Scan
PDF EWS1500 110kg EWS1500-5 Nemic-Lambda EWS1500 EWS-1500 Nemic-Lambda power supply unit Nemic-Lambda ews Nemic-Lambda users ws150 WS1500 Nemic-Lambda tog cnt
RC9002A

Abstract: Nemic-Lambda KWD15 KWD15-1212 KWD15-1515 RC-9002A
Text: , before using the power supply unit . = NOTES = *1. At 100VAC and Maximum Output Power , Ta , 0.65 0.52 0.52 4 Maximum Output Power (24V) CH1 +15V (30V) W 15.6 15.6 5 , . -V COM C=0.1uF Film Cap. *5. From Min load - Full load (Maximum power ), constant input


Original
PDF KWD15 PA775-01-01 KWD15-1212 KWD15-1515 265VAC 440Hz 340VDC 100VAC 100VAC, 200VAC RC9002A Nemic-Lambda KWD15-1212 KWD15-1515 RC-9002A
j 6806 Cross Reference

Abstract: RP1000 - 3AH -Z RP1000 12V-4A RP0550-4DH-Z Nemic-Lambda power supply unit coutant power supply 5V RP0750-4AH-Z coutant MARKING CODE 150A
Text: outputs may be added. By facilitating total system power solutions in a single unit , the RP series , . CE-EMC Compliance The RP Series represents the first power supply which complies with both the LVD and , by significantly reducing power supply emissions and ensures worldwide acceptance of the final system , power supply which is capable of handling increased power requirements for logic, memory, card power and , ) MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN .25 (6.3) 3. DIMENSIONS ARE IN INCHES EXCEPT


OCR Scan
PDF TEL82-2-556-1171 1-800-LAMBDA-4 TEL52-83-652020 TEL52-5-575-9929 j 6806 Cross Reference RP1000 - 3AH -Z RP1000 12V-4A RP0550-4DH-Z Nemic-Lambda power supply unit coutant power supply 5V RP0750-4AH-Z coutant MARKING CODE 150A
Not Available

Abstract: No abstract text available
Text: 99 67 *Read instruction manual carefully, before using the power supply unit . =NOTES= *1. At 100/200VAC, Ta=25°C and maximum output power . *2. For cases where conformance to various safety specs , Output Power W Efficiency (Typ) (*1) % Input Voltage Range (*2) Input Current (100/200VAC)(Typ) (*1) A Inrush Current(Typ) PFHC Power Factor (100/200VAC)(Typ) (*1) Output Voltage Range V Maximum , Derating at standard mounting. - Load (%) is percent of maximum output power or maximum output current


Original
PDF A160-01-01A JWS150 265VAC 330VDC 100VAC, 200VAC,
ZWS300

Abstract: No abstract text available
Text: 50 x 255 ( Refer to Outline Drawing ) Read instruction manual carefully, before using the power supply unit . =NOTES= *1 Duration under peak application is limited less than 30seconds.(Average output , Current (*1) Maximum Output Power (Convection) Maximum Output Power (Forced air) Maximum Peak Output Power (*1) Efficiency (100/200VAC) (Typ.) (*2) Input Voltage Range (*3) Input Current (100/200VAC , maximum output power . *3 100 ~ 120/200 ~ 240VAC indicated on the name plate in accordance with safety


Original
PDF ZWS300 A177-01-01-C 100/200VAC) A177-01-02_ A177-01-03_ A177-01-02 ZWS300
Nemic-Lambda power supply unit

Abstract: Fuse t8a 250v T8A marking din rail en 50022 - 35x7.5 EN50022 en50022 DIN Mounting Rail 0403a VDE0160 NES240 RAIL en50022
Text: . Installation using mounting screws (NES240-_/A) Use M4 screws to fix the Power Supply to the mounting surface.Refer to outline drawing for mounting holes location. Screws must not protrude into the Power Supply , current of the end use equipment should not exceed 3.5mA. 3. DO NOT OPEN POWER SUPPLY . Hazardous voltages , 1. MOUNTING SCREWS MUST NOT PROTRUDE INTO THE POWER SUPPLY MORE THAN 6 mm. 2. INPUT AND LOAD WIRES , 5.0 B 3 Maximum Output Power W 4 Efficiency (Typ) % 5 Input Voltage Range


Original
PDF NES240 265VAC 100Vac, 200Vac Nemic-Lambda power supply unit Fuse t8a 250v T8A marking din rail en 50022 - 35x7.5 EN50022 en50022 DIN Mounting Rail 0403a VDE0160 RAIL en50022
Nemic-Lambda users

Abstract: din rail en 50022 - 35x7.5 T8A marking EN50022 EN50022-35X7 Nemic-Lambda power supply unit NES240 L508 EN55022-B RAIL en50022
Text: using mounting screws (NES24Q-_/A) Use M4 screws to fix the Power Supply to the mounting surface. Refer to outline drawing for mounting botes location. Screws must not protrude into the Power Supply , current of the end use equipment should not exceed 3.5mA. 3. DO NOT OPEN POWER SUPPLY Hazardous voltages , ■•<•.<1 c_ ] i- . O NOTES 1 MOUNTING SCREWS MUST NOT PROTRUDE INTO THE POWER SUPPLY MORE , Output Power W 240 4 Efficiency (Typ) % 82 at 100Vac, 84 at 200Vac .rated output power A 5 Input


OCR Scan
PDF NES240 NES240- 100Vac, 200Vac 265VAC Nemic-Lambda users din rail en 50022 - 35x7.5 T8A marking EN50022 EN50022-35X7 Nemic-Lambda power supply unit L508 EN55022-B RAIL en50022
JWS240P-24

Abstract: JWS240P-48
Text: Outline Drawing ) *Read instruction manual carefully, before using the power supply unit . =NOTES= *1 , Output Current Peak Output Current (*1) Average Output Power Peak Output Power (*1) Efficiency (Typ , ) PFHC Power Factor (100/200VAC)(Typ) (*2) Output Voltage Range Maximum Ripple & Noise 0 ~ +65°C , power . *3. For cases where conformance to various safety specifications (UL, CSA, EN) are required , standard mounting. - Load (%) is percent of average output power or averge output current, whichever is


Original
PDF A182-01-01 100/200VAC) A182-01-02_ 100VAC. A1820101 A182-01-02 A1820102 JWS240P-24 JWS240P-48
Supplyframe Tracking Pixel