The Datasheet Archive

Top Results (6)

Part ECAD Model Manufacturer Description Datasheet Download Buy Part
COM1553A/B COM1553A/B ECAD Model Rochester Electronics LLC COM1553A/B - Mil-Std-1553B Smart Controller Visit Rochester Electronics LLC
1206USB-172MBC 1206USB-172MBC ECAD Model Coilcraft Inc Data Line Filter, 2 Function(s), EIA STD PACKAGE SIZE 1206 Visit Coilcraft Inc Buy
1206USB-672MBC 1206USB-672MBC ECAD Model Coilcraft Inc Data Line Filter, 2 Function(s), EIA STD PACKAGE SIZE 1206 Visit Coilcraft Inc Buy
1206USB-371MBC 1206USB-371MBC ECAD Model Coilcraft Inc Data Line Filter, 2 Function(s), EIA STD PACKAGE SIZE 1206 Visit Coilcraft Inc Buy
1206USB-172MBB 1206USB-172MBB ECAD Model Coilcraft Inc Data Line Filter, 2 Function(s), EIA STD PACKAGE SIZE 1206 Visit Coilcraft Inc Buy
1206USB-672MBB 1206USB-672MBB ECAD Model Coilcraft Inc Data Line Filter, 2 Function(s), EIA STD PACKAGE SIZE 1206 Visit Coilcraft Inc Buy

MIL-STD-202 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2009 - QQ-S365

Abstract: TEFLON MIL-P-19468 MIL-P-19468 mil-std-202 mil-std-202 METHOD 106 QQC-530 QQ-B-626
Text: 253/124 [2.8/1.4] 500 25 [2.8] -55 to +85 -65 to +165 MIL-STD-202 Method 201A -65 to +1651 -55 to +852 MIL-STD-202 MIL-STD-202 Method 204 Method 204 Cond. B Cond. B MIL-STD-202 MIL-STD-202 Method 213 Method 213 Cond. G, 50 G’s Cond. G, 50 G’s -65 to +85 — -65 to +165 -65 to +165 -55 to +85 -55 to +85 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G MIL-STD-1344 Method


Original
PDF ohm/75 P-24519. QQ-S365 TEFLON MIL-P-19468 MIL-P-19468 mil-std-202 mil-std-202 METHOD 106 QQC-530 QQ-B-626
2002 - L44PCW

Abstract: MIL-STD-202 METHOD 101 MIL-STD-202 METHOD 213 Andrew L44PCW connector mil-std-202, method 107 27591-109 LDF4RN-50A-S3 mil-std-202 METHOD 106 mil-std-202, method 204,cONDITION A mil-std-202, method 204
Text: Operating Temperature Range, °C Storage Temperature Range, °C MIL-STD-202 , Method 106 MIL-STD-202 , Method 213, Condition I MIL-STD-202 , Method 101, Condition B MIL-STD-202 , Method 107, Cond A-1, Low Temp -55°C MIL-STD-202 , Method 204, Condition B -55 to 150 -70 to 150 0.05 frequency(GHz) Solder on Self , Operating Temperature Range, °C Storage Temperature Range, °C MIL-STD-202 , Method 106 MIL-STD-202 , Method 213, Condition I MIL-STD-202 , Method 101, Condition B MIL-STD-202 , Method 107, Cond A-1, Low Temp


Original
PDF L44PCW LDF4-50A, MIL-STD-202, L44PCW MIL-STD-202 METHOD 101 MIL-STD-202 METHOD 213 Andrew L44PCW connector mil-std-202, method 107 27591-109 LDF4RN-50A-S3 mil-std-202 METHOD 106 mil-std-202, method 204,cONDITION A mil-std-202, method 204
mil-std-202, method 107

Abstract: qq-c-576
Text: [2.8] 6/6 [26.7/26.7] 60 [2669] 601266.9] RG58C/U 500 25 [2.8] -65 to+85 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G (50 G , ’s) MIL-STD-202 Method 107 -65 to +165' -55 to +852 MIL-STD-202 Method 204 Cond B MIL-STD-202 Method 213 Cond. I, (100 G’s) MIL-STD-202 Method 107 Cond. B MIL-STD-202 Method 106 MIL-STD-202 Method 101 Cond. B 108-12001 , [266.9] 500 25 [2.8] 2 [.023] 100 [4448] 40 [178 0] 500 25 [2.8] -65 to +165 MIL-STD-202


OCR Scan
PDF Q-N-290 QQ-N-290 MIL-G-45204 MIL-P-24519. mil-std-202, method 107 qq-c-576
2011 - 2455R

Abstract: 2455RM 2455RVB MIL-STD-202 METHOD 302 MIL-STD-202 METHOD 301 2450RC mil-std-202 method 112 2450CM 2450H MIL-PRF-24236
Text: strength MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case Insulation resistance MIL-STD-202 , Method 302; 50 MOhm min. Terminal to Case Contact resistance MIL-STD-202 , Method 307; 0.050 Ohm Hermetic seal MIL-STD-202 , Method 112; Cond. A, 1x10-5 atm cc/s Moisture resistance MIL-STD-202 , ] Dielectric strength MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case


Original
PDF 009031-2-EN 2455R 2455RM 2455RVB MIL-STD-202 METHOD 302 MIL-STD-202 METHOD 301 2450RC mil-std-202 method 112 2450CM 2450H MIL-PRF-24236
MIL-P-19468

Abstract: No abstract text available
Text: MIL-STD-202 Method 204 Cond B MIL-STD-202 Method 213 Cond G MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G MIL-STD-1344 Method 2005 Cond. Ill MIL-STD-1344 Method 2004 Cond , -1344 Method 1001 Cond. B 108-12044 108-12047 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 , , Operating (C°) Vibration Physical Shock -65 to +165’ -55 to +85" MIL-STD-202 MIL-STD-202 Method 204 Method 204 Cond.B Cond. B MIL-STD-202 MIL-STD-202 Method 213 Method 213 Cond. G, 50 G


OCR Scan
PDF WIIL-C-39012 QQ-S-365 QQ-S-365 MIL-B-45204 MIL-G-45204 MIL-G-45204 QQ-N-290 MIL-P-19468
2008 - 2455R

Abstract: 2455rm 2455Rc 2455rbv 2450rc gold metal detectors 2455 Sealed Thermostat thermostat cap thermostats
Text: strength MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case Insulation resistance MIL-STD-202 , Method 302; 50 MOhm min. Terminal to Case Contact resistance MIL-STD-202 , Method 307; 0.050 Ohm Hermetic seal MIL-STD-202 , Method 112; Cond. A, 1x10-5 atm cc/s Moisture resistance MIL-STD-202 , ] Dielectric strength MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case


Original
PDF 009031-1-EN 2455R 2455rm 2455Rc 2455rbv 2450rc gold metal detectors 2455 Sealed Thermostat thermostat cap thermostats
TR62P

Abstract: TR62Y502 TR62Y mil-r-22097 94v0 schematic TR06P103 mil-std-202 method 107d TR04G205 Potentiometers 25k TR03G102T
Text: 250ppm/_C on all other resistance values), MIL-STD-202 , method 304. INSULATION RESISTANCE: 100 megohms min. @ 500 V DC, MIL-STD-202 , method 302, condition B. DIELECTRIC STRENGTH: 500 V AC min., MIL-STD-202 , minutes each, 5 cycles MIL-STD-202 , method 107D, TRS ± 2% max., setting stability (voltage ratio) ± 1% max. MOISTURE RESISTANCE: Humidity cycle, MIL-STD-202 , method 106D, TRS ± 3% max. HUMIDITY: 40°C, 90 to 95% RH, MIL-STD-202 , method 103B, condition C, TRS ± 3% max., setting stability (voltage ratio


Original
PDF TR03G500T TR03J500T TR03G101T TR03G201T TR03G501T TR03G102T TR03G202T TR03G502T TR03G103T TR62P TR62Y502 TR62Y mil-r-22097 94v0 schematic TR06P103 mil-std-202 method 107d TR04G205 Potentiometers 25k TR03G102T
MOX-750

Abstract: MOX400 Meg-90 MIL-R-49462A MEG40
Text: Power Conditioning Solderability Test Method MIL-STD-202 , Method 103B, Condition B MIL-STD-202 , Method 301, 750V MIL-STD-202 , Method 302, Condition A or B MIL-STD-202 , Method 107G, Condition B, B-1, or F MIL-STD-202 , Method 108A, Condition D MIL-STD-202 , Method 215G MIL-STD-202 , Method 211A, Condition A or B MIL-STD-202 , Method 213B, Condition I MIL-STD-202 , Method 204D, Condition D MIL-R-49462A, Par 4.8 MIL-STD-202 , Conditioning Solderability Test Method MIL-STD-202 , Method 103B, Condition B MIL-STD-202 , Method 301, 750V


Original
PDF 25K-6 Meg-100 Meg-200 Meg-300 Meg-400 Meg-500 MOX-750 MOX400 Meg-90 MIL-R-49462A MEG40
EIA-198

Abstract: RPE MuRata RPE 113 EIA-198 method 103 EIA-RS-483 RPE-114 eia 198 RPE 114 x7r MIL-C-14409 RPE114
Text: not listed here. Barometric Pressure (Reduced): EIA-198 Method 207 or MIL-STD-202 Method 105 , (Dissipation Factor): EIA-198 Method 101 or MIL-STD-202 Method 305. Capable of MHz (10KHz to 10MHz) or KHz (100Hz to 100Khz). DWV (Dielectric Withstanding Voltage): EIA-198 Method 103 or MIL-STD-202 Method 301 , -198 Method 202 Cond. "B" or MIL-STD-202 Method 103, 40°C @ 90 to 95 % R.H. (with no voltage) test duration usually 504 hours. IR (Insulation Resistance): EIA-198 Method 104 or MIL-STD-202 Method 302. Resistance


Original
PDF spa60g MIL-PRF-55681 MIL-C-14409 CG01-I EIA-198 MIL-STD-202 10KHz 10MHz) 100Hz 100Khz) RPE MuRata RPE 113 EIA-198 method 103 EIA-RS-483 RPE-114 eia 198 RPE 114 x7r RPE114
2010 - Not Available

Abstract: No abstract text available
Text: Conditions Mechanical Shock MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202


Original
PDF CCSO-914-1090 CCSO-914-1090 CCSO-014-1090 090GHz -138dBc/Hz 10kHz -40dBc 02-Feb-10 MIL-STD-202,
mil-std-202

Abstract: mil-std-202 method 213 method c 1090mhz oscillator SAW oscillator 1090
Text: Mechanical Shock MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202 , Method 112, Procedure III


Original
PDF CCSO-014-1090 CCSO-014-1090 090GHz -138dBc/Hz 10kHz -35dBc 23-Feb-11 cry-STD-202, MIL-STD-202, mil-std-202 mil-std-202 method 213 method c 1090mhz oscillator SAW oscillator 1090
MIL-R-39007

Abstract: Steatite Group lb 1260 49R9
Text: -watt size and larger. Solderability: Meets requirements of MIL-STD-202 Solvent resistance: Meets requirements of MIL-STD-202 MIL-R-39007: This is the military specification covering axial lead established , . resistance MIL-STD-202 , method 303 Within tolerance Visual & mechanical Visual inspection Temperature cycle Method 102, MIL-STD-202 .2% + .05 Short time overload 5 seconds at 10 or 5 times , Dielectric strength 500V or 1000V .1% + .05 Insulation Resistance Method 302, MIL-STD-202 1000


Original
PDF MIL-R-39007 MIL-STD-202 MIL-R-39007: MIL-R-39007 Steatite Group lb 1260 49R9
MF-200

Abstract: Precision Resistive Products MIL-STD-202 METHOD 301 MF-100 MF-12 MF-25 MF-50 T100 TC25 TC50
Text: conditioning periods.) MIL-STD-202 Method 303 Within specified tolerance. As buyer requested ±25PPM/°C ±100PPM/°C ±50PPM/°C ±200PPM/°C DC RESISTANCE TEMPERATURE COEFFICIENT MIL-STD-202 Method 304 MIL-STD-202 Method 301 1/8W 300V 1 minute 1/4W 500V 1 minute 1/2W 700V 1 minute 1, 2W 750V 1 minute MIL-STD-202 Method 302 100V 1 minute DIELECTRIC STRENGTH No flashover or damage INSULATION , 0.05) RESISTANCE TO SOLVENT MIL-STD-202 Method 201 10~ Hz X.Y.Z. 3 directions 2 hours each


Original
PDF 100PPM/ MF-12 MF-25 MF-50 MF-100 MF-200 MIL-STD-202 MIL-R-10509 MF-200 Precision Resistive Products MIL-STD-202 METHOD 301 MF-100 MF-12 MF-25 MF-50 T100 TC25 TC50
Not Available

Abstract: No abstract text available
Text: MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202 , Method 112, Procedure III, Condition


Original
PDF CCSO-014-1090 CCSO-014-1090 10kHz -35dBc 15-May-12 MIL-STD-202,
2010 - Not Available

Abstract: No abstract text available
Text: Conditions Mechanical Shock MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202


Original
PDF CCSO-014-1090 CCSO-014-1090 090GHz -138dBc/Hz 10kHz -40dBc 18-Mar-10 MIL-STD-202,
29862

Abstract: 0434002 R451.750 0434003
Text: CSA. Approved by MITI from 1 through 5 amperes. Operating Temperature: –55°C to 125°C. Shock: MIL-STD-202 , Method 213, Test Condition 1 (100 Gs peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (10-55 Hz, 0.06 in. total excursion). Salt Spray: MIL-STD-202 , Method 101, Test Conditions B (48 hours). , .) Resistance to Soldering Heat: MIL-STD-202 , Method 210, Test Conditions F (20 sec. at 260°C). Thermal Shock: MIL-STC- 202 , Method 107, Test Condition B (–65° to 125°C). Moisture Resistance: MIL-STD-202 , Method 106


Original
PDF
0451001.mrl

Abstract: 32vdc12a 001T 0451001mrl 0452500 0452001.MRL
Text: . Ambient Temperature: ­ 55°C to +125°C. Shock: MIL-STD-202 , Method 213, Test Condition I (100 G's peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (10­ 55 Hz). Thermal Shock: MIL-STD-202 , . Solderability: MIL-STD-202 , Method 208. For iron soldering, Solder Iron Temp: 350° C ­ 360° C, heating time 3 ­ , : MIL-STD-202 , Method 213, Test Condition I Refer to pg. 374 for SMF Omni-Blok® Holder, Series 154 000 , milliseconds). Vibration: MIL-STD-202 , Method 201 (10­55 Hz). Salt Spray: MIL-STD-202 , Method 101, Test


Original
PDF
1998 - R451.750

Abstract: No abstract text available
Text: /VDC (12A - 15A) ENVIRONMENTAL SPECIFICATIONS: Operating Temperature: - 55°C to 125°C. Shock: MIL-STD-202 , Method 213, Test Condition I (100 G's peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (lo-55 Hz, .06 in. total excursion). Salt Spray: MIL-STD-202 , Method 101, Test Condition B (48 hrs.). Insulation Resistance (After Opening) MIL-STD-202 , Method 302, Test Condition A, (10,000 ohms minimum). Resistance to Soldering Heat: MIL-STD-202 , Method 210, Test Condition F (20 sec. at 260°C). Thermal Shock


Original
PDF l/16-15 l/16-10 20seconds E10480, 125VAC/VDC 125VACYVDC 65VAC/VDC R452005 R451.750
1998 - R460.002

Abstract: No abstract text available
Text: SPECIFICATIONS: Operating Temperature: - 55°C to 125°C. Shock: MIL-STD-202 , Method 213, Test Condition I (100 G's peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (lo-55 Hz, .06 inches total excursion). Salt Spray: MIL-STD-202 , Method 101, Test Condition B (48 hrs.). Insulation Resistance (After Opening) MIL-STD-202 , Method 302 (10,000 ohms minimum at 100 volts). Resistance to Soldering Heat: MIL-STD-202 , Method 210, Test Condition F (10 sec. at 260°C). Thermal Shock: MIL-STD-202 , Method 107, Test Condition B


Original
PDF E10480, 125VAC. 125VDC. MIL-STD-202, R460001 R460.002
fuse base IEC 269

Abstract: No abstract text available
Text: at 65 VAC/VDC ENVIRONMENTAL SPECIFICATIONS: Operating Temperature: ­55°C to 125°C. Shock: MIL-STD-202 , Method 213, Test Condition I (100 G's peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (10­55 Hz, .06 in. total excursion). Salt Spray: MIL-STD-202 Method 101, Test Condition B (48 hrs.). Insulation Resistance (After Opening): MIL-STD-202 , Method 302, Test Condition A, (10,000 ohms minimum). Resistance to Soldering Heat: MIL-STD-202 , Method 210, Test Condition F (20 sec. at 260°C). Thermal Shock


Original
PDF E10480, SPECIFI54 fuse base IEC 269
MF-200

Abstract: mil-std-202 method 304 MF-100 MF25 1K E192 Series mil-std-202 method 108 MIL-STD-202 METHOD 301 E192 MF-12 MF-25
Text: should be performed after stabilization or conditioning periods.) MIL-STD-202 Method 303 MIL-STD-202 , INSULATION RESISTANCE At least 1000M CURRENT NOISE TEST MIL-STD-202 Method 301 1/8W 300V 1 minute 1/4W 500V 1 minute 1/2W 700V 1 minute 1, 2W 750V 1 minute MIL-STD-202 Method 302 100V 1 minute MIL-STD-202 Method 308 5.11 to 9.99 less than 0.05µV/V 10 to 9.99K less then 0.1µV/V 10K to , R within ±(0.5% + 0.05) LOAD LIFE R within ±(1% + 0.05) RESISTANCE TO SOLVENT MIL-STD-202


Original
PDF MF-25 MF-50 MF-12 MF-100 472ections MIL-STD-202 MIL-R-10509 MF-200 mil-std-202 method 304 MF-100 MF25 1K E192 Series mil-std-202 method 108 MIL-STD-202 METHOD 301 E192 MF-12 MF-25
mil-std-202

Abstract: mil-std-202 method 213 method c mil-std-202 method 112 mil-std-202, method 210 1090mhz oscillator mil-std-202 method 108 method 208 mil-std-202 213 mil-std-202 method 215 MIL-STD-202 METHOD 208
Text: % Temperature Testing 100% Start-Up Testing Conditions MIL-STD-202 , Method 213, Condition A MIL-STD-202 , Method 204, Condition A MIL-STD-202 , Method 208 MIL-STD-202 , Method 215 MIL-STD-202 , Method 210, Condition C MIL-STD-202 , Method 107, Condition A MIL-STD-202 , Method 106, 90 to 98% RH 10 Days MIL-STD-202 , Method 211, Condition A MIL-STD-202 , Method 112, Procedure III, Condition C MIL-STD-202 , Method 103 MIL-STD-202 , Method 108, Condition D, 1,000 hrs at +70°C MIL-STD-202 , Method 212, Condition A 10°C Steps


Original
PDF CCSO-014-1090 1090MHz CCSO-014-1090 090GHz -138dBc/Hz 10kHz -40dBc MIL-STD-202, mil-std-202 mil-std-202 method 213 method c mil-std-202 method 112 mil-std-202, method 210 1090mhz oscillator mil-std-202 method 108 method 208 mil-std-202 213 mil-std-202 method 215 MIL-STD-202 METHOD 208
2001 - Not Available

Abstract: No abstract text available
Text: 207 or MIL-STD-202 Method 105. Capable of 0 to 600 VDC, usually performed up to100K feet at hot or , capacitor breaks. 0 to 50 lb. Maximum. Capacitance: EIA-198 Method 101 or MIL-STD-202 Method 305. Capable , MIL-STD-202 Method 305. Capable of MHz (10KHz to 10MHz) or KHz (100Hz to 100Khz). DWV (Dielectric Withstanding Voltage): EIA-198 Method 103 or MIL-STD-202 Method 301, usually 2.5 X rated voltage. Capable of , Test: EIA-198 Method 210 Cond.”C” or MIL-STD-202 Method 108, usually 1,000 or 2,000 hours @ rated


Original
PDF ISO-9001
Not Available

Abstract: No abstract text available
Text: - MIL-STD202 202 202 202 1344 MIL-STD- MIL-STD- MIL-STDMethod Method Method Method Method 202 Method 202 Method 202 Method 204 Cond. 204 Cond. 204 Cond. 204 Cond. 2005 Cond. 204 Cond. B 201A 204 Cond. B B B B B III MIL-STD- MIL-STD- MIL-STD- MIL-STD- MIL-STDMIL-STD- MIL-STD- MIL-STD1344 202 202 202 202 202 Method 202 Method 202 Method Method Method Method Method Physical Shock Method , - MIL-STDMIL-STD- MIL-STD- MIL-STD1344 202 202 202 202 202 Method 202 Method 202 Method Method Thermal Shock


Original
PDF MIL-STD1344 MIL-STD202
Not Available

Abstract: No abstract text available
Text: MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202 , Method 112, Procedure III, Condition


Original
PDF CCSO-014-1090 CCSO-014-1090 10kHz -35dBc 27-May-2014 239-561-1025-STD-202, MIL-STD-202,
Supplyframe Tracking Pixel