The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1399CS Linear Technology LT1399 - Low Cost Dual and Triple 300MHz Current Feedback Amplifiers with Shutdown; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C
LT1399CGN#TRPBF Linear Technology LT1399 - Low Cost Dual and Triple 300MHz Current Feedback Amplifiers with Shutdown; Package: SSOP; Pins: 16; Temperature Range: 0°C to 70°C
LT1399CS#PBF Linear Technology LT1399 - Low Cost Dual and Triple 300MHz Current Feedback Amplifiers with Shutdown; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C
LT1399CGN Linear Technology LT1399 - Low Cost Dual and Triple 300MHz Current Feedback Amplifiers with Shutdown; Package: SSOP; Pins: 16; Temperature Range: 0°C to 70°C
LT1399CS#TR Linear Technology LT1399 - Low Cost Dual and Triple 300MHz Current Feedback Amplifiers with Shutdown; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C
LT1399HVCS Linear Technology LT1399 - Low Cost Dual and Triple 300MHz Current Feedback Amplifiers with Shutdown; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C

MIL-STD-1399 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
TS1000A

Abstract: DOD-STD-1399 powercube a 100G 80ASP
Text: TS1000A TransnubberTM Features: · Suppresses the 2500 Volt Line Transients as Described in DOD-STD- 1399 . · Provides Attenuation of Conducted Line Interference in the Frequency Range as Specified in , 1 (DO D-STD- 1399 /300, up to 50 microseconds pulse width) are attenuated by 20dB minimum , TRANSIENT) WAVE SHAPE PER DOD-STD- 1399 /300 & /103 Figure 1 TransnubberTM ¡s a trademark of Powercube , -S1 &-S2 AC-DC PREREGULATOR SET TO 80G270W40A AND ISOLATED OUTPUT MODULE Shock: NOTE: 1. DOD-STD- 1399


OCR Scan
PDF TS1000A DOD-STD-1399. MIL-STD-461. MIL-STD-704A-D. D-STD-1399/300, Method-107D MIL-STD-810 IL-STD-202 47-63Hz DOD-STD-1399 powercube a 100G 80ASP
MIL-STD-2036

Abstract: 1.5ke series MIL-STD-1399 SEN-5425 0.4kw SEN-5439 sensitron 15kp SEN-5282 LSP11B-320 ABD 0007
Text: Clamping Voltage @ IPP Vc (Volts) Maximum Peak Pulse Current IPP (Amps) 49 120 MIL-STD-1399 Single Phase System Application Sensitron Part Number: SEN-5425 MIL-STD-1399 Compliant Features , 's Transient Voltage Suppressors: Exceed MIL-STD-1275 Exceed MIL-STD-1399 MIL-STD-2036 Exceed MIL-STD704/A and DOD-STD- 1399 requirements Meet UL-94V0 Flammability Classification http://www.sensitron.com , Protection Level: · +200VDC operating; Tailored for 115VAC · Exceed MIL-STD704A and DOD-STD- 1399


Original
PDF MIL-STD-1275 MIL-STD-1399 MIL-STD-2036 MIL-STD704/A DOD-STD-1399 UL-94V0 MIL-STD-2036 1.5ke series MIL-STD-1399 SEN-5425 0.4kw SEN-5439 sensitron 15kp SEN-5282 LSP11B-320 ABD 0007
Not Available

Abstract: No abstract text available
Text: 60KS200C and 90KS200C BIDIRECTIONAL TRANSIENT VOLTAGE SUPPRESSORS Microkemi Corp. f The üioüb exp erts : SANTA ANA, CA SCOTTSDALE, A Z For more information calh <602)94^300 FEATURES TRANSIENT ABSORPTION ZENER • 200 VOLT BIDIRECTIONAL • EXCEEDS MIL-STD-1399 , consistent with MIL-E-16400. Designed with MIL-STD-1399 Section 300A (Interface standard for shipboard , MIL-STD-1399 , Section 300A the source impedance is assumed to be 5 ohms at 100 to 200 kHz of shipboard


OCR Scan
PDF 60KS200C 90KS200C MIL-STD-1399 MIL-S-19500 MIL-E-16400. MIL-STD-1399, 60KS200C 80KS200C Q3722
2003 - PerkinElmer transformer

Abstract: A-0703 ce01 MIL-STD-1399 MIL-STD-461 ms3102E MIL-STD-167-1 DOD-STD-1399 470VAC
Text: Magnetic Interference: MIL-STD-461, Class A4 Line Harmonics: MIL-STD-1399 , Section 300 Cooling , 's), satisfy the 3% and 1/n limits of DoD-STD- 1399 , Section 300 as well as the CE01 limits of MIL-STD , /n limits of DoD-STD- 1399 , Section 300 · Complies with CE01 limits of MIL-STD-461 · With EMI


Original
PDF DoD-STD-1399, MIL-STD-461. MIL-STD-167-1 MIL-STD-461, MIL-STD-1399, DS336-Rev PerkinElmer transformer A-0703 ce01 MIL-STD-1399 MIL-STD-461 ms3102E MIL-STD-167-1 DOD-STD-1399 470VAC
80ASP12-S2

Abstract: cirkitblock powercube Powercube dc dc converter cirkitblock Powercube D1399 300 Type 80ASP12
Text: 140ADDC30 300 Watt 3(b AC-DC - Converter Features: · 140 VDC Output (Nominai) · 30,60 Hz input, 115VAC (line-to-line) ( MIL-STD-1399 See. 300 Type 1*) · High power - 300 watt output · Accepts positive transients equivalent to MIL-STD-704A/B. ADDC Series 300 Watt 3c AC-DC Converter p The ADDC Series , 1399 Sec 300 Type 1)* and converts it to a 110-160 VDC, non-isolated, filtered output. The output is , IL-STD - 1399 Sec 300 Type 1* equivalent to M IL-STD -704A/B plus positive transients * (except fo r 2500V


OCR Scan
PDF 140ADDC30 115VAC MIL-STD-1399 MIL-STD-704A/B. 80ASP12-S2 -704A/B 12Vpp IL-A-8025-II, 34fl3 cirkitblock powercube Powercube dc dc converter cirkitblock Powercube D1399 300 Type 80ASP12
Not Available

Abstract: No abstract text available
Text: ELECTRICAL SPECIFICATIONS Input PS2446 Total Power Input Voltages Outputs 9000 Watts 352-528 VAC Line to Line 270V @ 33A Max 28V @ 2A Max SPECIAL FEATURES • • • • • • • • • • Power factor >0.98 352-528 VAC Line to Line per MIL-STD-1399 , Section 300A , . Input………440 VAC per MIL-STD-1399 , section 300A, Type I 58.2 – 61.8Hz; Power Factor 0.98 Inrush , , RS101, RS103 DOD-STD- 1399 , section 70 for DC Magnetics Efficiency………………> 80% typical at


Original
PDF PS2446 MIL-STD-1399, 400Vdc 100ms
2001 - Not Available

Abstract: No abstract text available
Text: 60KS200C 90,000 WATTS DESCRIPTION This series of devices were designed in accordance with DOD-STD- 1399 , section 300 (formally MIL-STD-1399 ) interface standard and MIL-STD-704A for shipboard systems , Bidirectional Military Processing Available per MIL-PRF-19500 Exceeds DOD-STD- 1399 & MIL-STD-704A Requirements


Original
PDF 60KS200C 90KS200C MIL-PRF-19500 DOD-STD-1399 MIL-STD-704A DOD-STD-1399,
MIL-STD-1399

Abstract: 60KS200C 90KS200C
Text: Micro/semi Corp. The diode expert? SANTA ANA, CA SCOTTSDALE, AZ For mort- information call: (602) 941-6300 60KS200C and 90KS200C BIDIRECTIONAL TRANSIENT VOLTAGE SUPPRESSORS FEATURES • 200 VOLT BIDIRECTIONAL • EXCEEDS MIL-STD-1399 REQUIREMENTS • CAN BE SUPPLIED WITH JAN/JANTX PARTS , environmental requirements of MIL-S-19500 and is consistent with MIL-E-16400. Designed with MIL-STD-1399 Section , Curve FIGURE 2 NOTE: In MIL-STD-1399 , Section 300A1he source impedance is assumed to be 5 ohms at 100


OCR Scan
PDF 60KS200C 90KS200C MIL-STD-1399 MIL-S-19500 MIL-E-16400. MIL-STD-1399, 300A1he
MIL-STD-1399

Abstract: CS116 CE102 CS114 MIL-STD-461E RE102 CS101 RE101 FP494
Text: FP494 / FP496 ­ Rack Mount Power Source · Single and multiple output configurations · Ruggedized construction · Tailored MIL-STD-1399 Features · Power Good LEDs for both input and output voltages · Remote / local activate via IEEE, 802.3, 100 base FX · Elapsed time meter FP494 FP496 640 Watt Ruggedized 19" Rack Mount Dual Output Supply 575 Watt Ruggedized 19" Rack Mount Triple , Watt isolated output Input Power · 115 Vac, 1PH ( MIL-STD-1399 ) Environmental · 10 ms Hold-up


Original
PDF FP494 FP496 MIL-STD-1399 FP494 MIL-STD-1399) TemperatuFP494 MIL-STD-461E MIL-STD-1399 CS116 CE102 CS114 RE102 CS101 RE101
1999 - MIL-STD-704A

Abstract: DOD-STD-1399 1900-0020 MIL-STD-1399 60KS200C 90KS200C 90kW
Text: 60KS200C 90,000 WATTS DESCRIPTION This series of devices were designed in accordance with DOD-STD- 1399 , section 300 (formally MIL-STD-1399 ) interface standard and MIL-STD-704A for shipboard systems , Bidirectional Military Processing Available per MIL-PRF-19500 Exceeds DOD-STD- 1399 & MIL-STD-704A Requirements


Original
PDF 60KS200C 90KS200C MIL-PRF-19500 DOD-STD-1399 MIL-STD-704A DOD-STD-1399, DOD-STD-1399 1900-0020 MIL-STD-1399 60KS200C 90KS200C 90kW
60KS200C-90KS200C

Abstract: No abstract text available
Text: General ^ ^ Semiconductor ^ « Industries, Inc. FEATURES 60.000 watts Peak Pulse Power & 90.000 watts Peak Pulse Power 200 volts BIDIRECTIONAL Exceeds MIL-STD-1399 requirements Each Device 100% Tested APPLICATION . . .a Bidirectional Silicon Transient Suppressor for use in shipboard equip ment and other power , device was designed with DODSTD- 1399 , Section 300 (formerly MIL-STD-1399 ), Interface Standard for , the spike voltage wave in M IL STD 1399 Sec 103 Fig. 1 on Page 10 = 2500 volts - spike voltage am


OCR Scan
PDF MIL-STD-1399 DODSTD-1399, MIL-STD-1399) 60KS200C 60KS200C-90KS200C
abbott

Abstract: MIL-STD-1399 MIL-S-901 AR60C MTBF BATTERY CHARGER
Text: AR 60 60 Hz 3 Phase AC to Bulk DC Converter (Inherent Harmonic Suppression) · MIL-STD-1399 compliant · Passive power factor correction · Low parts count for high MTBF up to 500,000 hours (naval sheltered environment) · Rugged construction, MIL-STD-810 and MIL-S-901 compliant · MIL-STD , . 818-768-0395 POWER RATING Harmonic current limits in MIL-STD-1399 are based upon a percentage of , converter operating too far below its rating may draw harmonic currents in excess of MIL-STD-1399 limits


Original
PDF MIL-STD-1399 MIL-STD-810 MIL-S-901 MIL-STD-167 abbott AR60C MTBF BATTERY CHARGER
cirkitblock powercube

Abstract: cirkitblock Powercube Powercube dc dc converter TS1000A 80ASP12-S2 80ASP12
Text: 140ADDC10 100 Watt 3 AC-DC -Converter Features: · 3, 60 Hz input, 115 VAC (line-to-line) ( MIL-STD-1399 Sec. 300 Type 1*) · High power - 100 watt output · Accepts positive transients equivalent to MIL-STD-704A thru D. r- \ ADDC Series 100 Watt 3 AC-DC , , 115 VAC input (per D O D -S T D 1399 Sec 300 Type 1)* and converts it to a 120-185 VDC*, non-isolated , IL-STD- 1399 Sec 300 Type 1* equivalent to M IL-STD-704A/B plus positive transients Input Voltage


OCR Scan
PDF 140ADDC10 MIL-STD-1399 MIL-STD-704A 80ASP12-S2 IL-A-8625-II, MIL-T-10727 TS1000A. T34B373 cirkitblock powercube cirkitblock Powercube Powercube dc dc converter TS1000A 80ASP12
2002 - MIL-STD-1399

Abstract: 60KS200C 90KS200C IEC-61000-4-5
Text: -16400. Designed with MIL-STD-1399 Section 300A (Interface standard for shipboard systems, Electrical power , Exceeds MIL-STD-1399 requirements Can be supplied with JANTX subassemblies Module subassemblies are , ) Peak Pulse Power (PPP) or Current o (IPP) in percent of 25 C rating NOTE: In MIL-STD-1399 , Section


Original
PDF 60KS200C 90KS200C MIL-S-19500 MIL-E-16400. MIL-STD-1399 200kHz MIL-STD-1399 60KS200C 90KS200C IEC-61000-4-5
CE102

Abstract: CM500 MIL-S-901 MIL-STD-1399 CE101 MIL-S901
Text: 500 Watt Enclosed AC-DC Switchers for Extreme Environments FEATURES · Power Factor Correction · Fully compliant with MIL-STD 461D, CE101, CE102 · Meets MIL-S-901 (high-impact shock) · Meets MIL-STD-810F · FCC 20780 class A EMI compliance · Fully sealed to meet IP65 · Meets MIL-STD-1399 (spike voltage test) SPECIFICATIONS AC INPUT: 95-260 VAC 47-880 Hz single phase. Power factor corrected. Meets MIL-STD-1399 , Section 300, type I requirements (spike voltage test). EFFICIENCY: 80% minimum or greater


Original
PDF CE101, CE102 MIL-S-901 MIL-STD-810F MIL-STD-1399 MIL-STD-1399, CE102 CM500 MIL-S-901 MIL-STD-1399 CE101 MIL-S901
100MS

Abstract: bidirectional transient suppressor
Text: -16400. Designed with MIL-STD-1399 Section 300 (Interface standard for shipboard systems, Elec trical power , Microsemi Corp. y The ó tete experts SANTA ANA, CA SCOTTSDALE, ÂZ (602) 941-6300 For more information call: 60KS200C BIDIRECTIONAL TRANSIENT VOLTAGE SUPPRESSOR TRANSIENT ABSORPTION ZENER FEA TU RES · 200 VOLT BIDIREC TIONAL · EX C EED S M IL-STD- 1399 R EQ U IR EM EN TS · CAN BE SU P P LIED WITH J A N / J A N T X PARTS This device is a bidirectional Transient Suppressor for


OCR Scan
PDF 60KS200C IL-STD-1399 MIL-S-19500 MIL-E-16400. MIL-STD-1399 100MS bidirectional transient suppressor
Not Available

Abstract: No abstract text available
Text: .399 1.099 24 .300 .399 1.199 .300 .399 1.399 28 32 .300 .399 1.599 22 .400 .499 1.099 .499 24 .400 1.199 24 .600 .699 1.199 28 .600 .699 1.399 32 .600 .699 1.599 40 .600


OCR Scan
PDF 0000Sb3 MIL-STD-1344 MIL-STD-202
2011 - Not Available

Abstract: No abstract text available
Text: : UL, cTÜVus MIL-STD-810G for vibration and shock MIL-STD 704 and 1399 for overvoltage and , vibration, MIL-STD-704 and 1399 for transients and overvoltage, and have optional -40°C operational temp


Original
PDF EN61000-3-2 MIL-STD-810G EN61000-6-1 EN610003-3 VI-200 VI-J00
12cmef21a

Abstract: 120ALDF6 powercube EF50A MIL-E-4158 120ALDF MIL-STD-217E MIL-STD-461B
Text: configurations per MIL-STD-704 and DOD-STD- 1399 when used together with our 120ALDF6 and other A C-D C conversion , -704D, DOD-STD(Continuous) 1399 /300 and MIL-E-4158 when used in conjunction with the 120ALDF6 or other similar


OCR Scan
PDF MIL-STD-704A MIL-HDBK-217E P-3641, P4855-1A MIL-STD-461/462 MIL-STD-810C GB/25 MIL-STD-217E, 12cmef21a 120ALDF6 powercube EF50A MIL-E-4158 120ALDF MIL-STD-217E MIL-STD-461B
2004 - MIL-STD-461 CS101

Abstract: MIL-STD-704A CS02 CS-116
Text: MI-A22-xx MI-ComPAC 28 V MIL-STD-1275A MIL-STD-1275B MIL-STD-1399 : Interface Standard for Shipboard Systems Module MI-J5x-xx MI-25x-xx MI-MegaMod 155 V MIL-STD-1399A MIL-STD-1399B MIL-STD-1399C


Original
PDF MIL-STD-704: MI-22x-xx MI-26x-xx MI-A22-xx MI-A66-xx MIL-STD-704A MIL-STD-704D MIL-STD-704E MIL-STD-1275: MIL-STD-461 CS101 MIL-STD-704A CS02 CS-116
2003 - CE102

Abstract: CE101 MIL-STD-704A MIL-STD-704E MIL-STD-1399A CS02
Text: MI-A22-xx MI-ComPAC 28V MIL-STD-1275A MIL-STD-1275B MIL-STD-1399 : Interface Standard for Shipboard Systems Module MI-J5x-xx MI-25x-xx MI-MegaMod 155V MIL-STD-1399A MIL-STD-1399B MIL-STD-1399C


Original
PDF MIL-STD-704: MI-22x-xx MI-26x-xx MI-A22-xx MI-A66-xx 24Vin 300Vin MIL-STD-704A MIL-STD-704D MIL-STD-704E CE102 CE101 MIL-STD-704A MIL-STD-704E MIL-STD-1399A CS02
2015 - CGE2E18H5FWB-16

Abstract: No abstract text available
Text: CHARACTERISTICS Total Output Power Continuous 4000W 15s Transient 5250W MIL-STD-1399 115V L-L MIL-STD-1399 200V L-L Table II Steady-state Table II Steady-state Table III Transient 120s 50 , 31.5 Continuous Operation Region 31.0 3000 MIL-STD-1399 3Φ Voltage Ranges Shown 2000 , MIL-STD-1399-300B - Interface Shipboard ♦ Full power operation: -40°C to +55°C ♦ MIL-STD


Original
PDF MPS-4000-1U 80-265VrmsL-L 47-800Hz 4V-48V CGE2E18H5FWB-16
2015 - Not Available

Abstract: No abstract text available
Text: EMI filters, this supply is designed to comply with MILSTD-704, and MIL-STD-1399. The complete , standards: PENDING MIL-STD-1399 MIL-STD-704-2, -704-4, & -704-6* (see 704 app section) Contents Page , output P2: 2 output PENDING AC115: MIL-STD-704 (A-F) MIL-STD-1399 1: Single Phase 6 Digit


Original
PDF MTQ-Px-AC115-1 MILSTD-704, MIL-STD-1399.
MIL-STD-1399A

Abstract: MIL-STD-1275 MIL-STD-461 MIL-STD-1399C MIL-STD-704D CS02 MIL-STD-1399 MIL-STD-704A
Text: MIL-STD-1275A © © MIL-STD-1275B © © Mi-ComPAC 28V MIL-STD-1399 : Interface Standard for Shipboard Systems Module MI-J5x-xx Ml-25x-xx M I-M egaM od 155V MIL-STD-1399A © © © MIL-STD-1399B © MIL-STD-1399C © © © © © MIL-STD-461 : Electromagnetic Emissions and Susceptibility Requirements


OCR Scan
PDF MIL-STD-704: Ml-22x-xx MIL-STD-704A MIL-STD-704D MIL-STD-704E 24Vin 300Vin MIL-STD-1275: 28Vdc MIL-STD-1275A MIL-STD-1399A MIL-STD-1275 MIL-STD-461 MIL-STD-1399C MIL-STD-704D CS02 MIL-STD-1399 MIL-STD-704A
What is a TRANSZORB

Abstract: TRANSZORB 90A-1974 3 Volt transzorb c37.90a C37-90 5 Volt transzorb 28 volt transzorb rural electrification administration
Text: 5ps, 600volts; 50ms, 80volts; ac 10ms, 180volts. MIL-STD-1399 (DOD-STD- 1399 ) (Interface Standard for


OCR Scan
PDF 10/1000us) 8/20us) What is a TRANSZORB TRANSZORB 90A-1974 3 Volt transzorb c37.90a C37-90 5 Volt transzorb 28 volt transzorb rural electrification administration
Supplyframe Tracking Pixel