Catalog Datasheet MFG & Type PDF Document Tags
2002 - Relay M302 Reliability

Abstract: Leach relay M302 M302 PCB Leach relay M83536
Text: M302 ENGINEERING DATA SHEET RELAY - LATCH 2 PDT, 10 AMP Polarized, latching hermetically sealed relay 2 PDT Contact arrangement Meets the requirements of Coil supply MIL-R-83536/12 and /13 Direct , M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A , SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , . Intrinsically safe relay . CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000


Original
PDF MIL-R-83536/12 SC400 SC401-1 SC401-2 SC402 Relay M302 Reliability Leach relay M302 M302 PCB Leach relay M83536
2002 - Relay M302 Reliability

Abstract: Leach relay M302 Leach relay M83536 3 PDT M302 leach M302 PCB relay m300 Leach relay M83536 Relay leach all zener diode colour code silicone R140
Text: M302 ENGINEERING DATA SHEET RELAY - LATCH 2 PDT, 10 AMP Polarized, latching hermetically sealed relay 2 PDT Contact arrangement Meets the requirements of Coil supply MIL-R-83536/12 and /13 Direct , RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 , SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , . Intrinsically safe relay . CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000


Original
PDF MIL-R-83536/12 SC400 SC401-1 SC401-2 SC402 Relay M302 Reliability Leach relay M302 Leach relay M83536 3 PDT M302 leach M302 PCB relay m300 Leach relay M83536 Relay leach all zener diode colour code silicone R140
2002 - M300 relay

Abstract: S301-B1A2 M300 leach MIL-S-12883 Leach relay socket S300-A1B3 S300A1A2 M300-D4A FLR300 S30-1
Text: 1 X1 Y1 X1 Y2 POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 MM 2 X2 1 DETAIL 0.9 , S300, S301, S302 ENGINEERING DATA SHEET RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC Coil), FD300, FLS300, FLR300 GENERAL CHARACTERISTICS , Po, N.T. Hong Kong Tel: (852) 2 191 3830 Fax: (852) 2 389 5803 Featuring LEACH © power and control


Original
PDF FD300, FLS300, FLR300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 M300 relay S301-B1A2 M300 leach MIL-S-12883 Leach relay socket S300-A1B3 S300A1A2 FLR300 S30-1
all zener diode colour code

Abstract: S300-A1A2 MIL-S-12883 S300-A6B3 M300 relay Leach Relay S300-A9B9 S300-A8B9 CECC16101-018 FD300 diode
Text: M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A , -Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , M400, M401 , M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , or 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL


Original
PDF PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 all zener diode colour code S300-A1A2 MIL-S-12883 S300-A6B3 M300 relay Leach Relay S300-A9B9 S300-A8B9 FD300 diode
2002 - CECC16303-801

Abstract: Leach relay M83536 CECC16101-018 all zener diode colour code M300 relay M300 leach m2xx m300A silicone R140 M83536/S300-A6B3
Text: POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , -Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , M400, M401 , M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , or 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL


Original
PDF PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 CECC16303-801 Leach relay M83536 all zener diode colour code M300 relay M300 leach m2xx m300A silicone R140 M83536/S300-A6B3
2002 - s300a

Abstract: FD300 diode relay m300
Text: POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , -Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , M400, M401 , M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL


Original
PDF PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 s300a FD300 diode relay m300
2002 - all zener diode colour code

Abstract: Leach relay M83536 CECC16101-018 CECC16303-801 relay studs m300d LEACH switch FD300 diode leach relay series E M400 relay
Text: RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 , SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , M301 ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, 10 AMP Non latching hermetically sealed relay , 400 Hz 40 grams max 26 x 28.6 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL , Leach International prior to choosing a component. Date of issue: 3/06 - 105 - Page 1 of 4


Original
PDF MIL-R-83536/11 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 all zener diode colour code Leach relay M83536 CECC16303-801 relay studs m300d LEACH switch FD300 diode leach relay series E M400 relay
2002 - Leach relay M83536 3 PDT

Abstract: leach relay 250
Text: B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 MM 2 X2 1 DETAIL 0.9 , -Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , M400, M401 , M301 ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, 10 AMP Non latching hermetically sealed relay , Vac 400 Hz 40 grams max 26 x 28.6 x 13.3 Intrinsically safe relay . CONTACT ELECTRICAL , Vac, 400 Hz 10 8 4 2 60 @115/200 Vac, 400 Hz, 3Ø 10 8 4 2 Featuring LEACH © power and control


Original
PDF MIL-R-83536/11 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 Leach relay M83536 3 PDT leach relay 250
2002 - FLS300

Abstract: relay studs m300d relay socket studs M300 relay Leach relay M302 leach relay
Text: RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 , FLS300 ENGINEERING DATA SHEET TIME DELAY RELAY 1PST (SSO) Time delay relay (on operate, on , and comparison. Contact Leach International prior to choosing a component. Date of issue: 3/06 - , DATA SHEET S300, S301, S302 RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC Coil), FD300, FLS300, FLR300 2.35 ± 2.8 ± SEE MOUNTING


Original
PDF FLS300 25mAmps FLS300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 relay studs m300d relay socket studs M300 relay Leach relay M302 leach relay
2002 - M300 relay

Abstract: S301-C8A8
Text: POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , FLS300 ENGINEERING DATA SHEET TIME DELAY RELAY 1PST (SSO) Time delay relay (on operate, on , ) _| | 6-Accuracy (1,2,3) | Featuring LEACH , SHEET RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC Coil), FD300, FLS300, FLR300 GENERAL CHARACTERISTICS Crimp tool contact #22 Insertion and


Original
PDF FLS300 25mAmps FLS300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 M300 relay S301-C8A8
2002 - M400D

Abstract: Leach Relay 0.5 amp 2 pdt LRE M300 MS27709 m400 leach T412 RELAY M402D MIL-C-39029 complete standard Leach relay M400 silicone R140
Text: T402 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay on operate or on , Leach International prior to choosing a component. Date of issue: 3/06 - 61 - Page 1 of 4 , Leach International prior to choosing a component. Date of issue: 3/06 - 24 - 0.1 MS N° FOR , , TOLERANCE SEE CODE B FOR M400 RELAY FOR M402 RELAY CODE B S401 15.24 10.16 5.08 3 D 15.24 C 5.08 B A X1 , 10.16 X1 26.3 15.9 28.2 ± 0.3 FOR M401 RELAY , FOR K COIL FOR M401 RELAY , FOR J COIL


Original
PDF /30mV 28VdC 115Vac/60-400Hz SC400 SC401-1 SC401-2 SC402 M400D Leach Relay 0.5 amp 2 pdt LRE M300 MS27709 m400 leach T412 RELAY M402D MIL-C-39029 complete standard Leach relay M400 silicone R140
2002 - M300 relay

Abstract: Leach relay high temperature M300 leach Leach International M300
Text: POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , power switching and high reliability are required over a wide temperature range. Featuring LEACH , standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay , contact gap, maximum voltage capabilities of the relay contact system, and the , : A designer is working with a 55 volt DC system and has a relay rated at 10 amps resistive at 28


Original
PDF TDH-6070/6071 MIL-STD-883, 1x10-8 MIL-T-10727 TDH-6070/71 MIL-R-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B M300 relay Leach relay high temperature M300 leach Leach International M300
2002 - S301-B1A2

Abstract: m302 relay Leach Relay
Text: POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , initial product selection and comparison. Contact Leach International prior to choosing a component , CONTRASTING BEAD .200 TYPICAL CONTRASTING BEAD TIME DELAY RELAY DE-ENERGIZED OUTPUT ENERGIZED , CONTACTS FOR DC VOLTAGES ABOVE NOMINAL RATING N°101 To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay , contact gap


Original
PDF TDH-6060/6061 MIL-STD-883, MIL-T-10727 TDH-6060/61 MIL-PRF-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S301-B1A2 m302 relay Leach Relay
2002 - TDH-6050

Abstract: m302 relay S300-A1A2
Text: POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , and comparison. Contact Leach International prior to choosing a component. Date of issue: 3/06 - , CONTRASTING BEAD TIME DELAY RELAY DE-ENERGIZED OUTPUT DETAIL VIEW A ENERGIZED DETAIL VIEW B ALL , of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay , contact gap, maximum voltage capabilities of the relay contact system, and the contact material. The most


Original
PDF TDH-6050/6051 MIL-STD-883, 1x10-8 MIL-T-10727 TDH-6050/51 MIL-PRF-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B TDH-6050 m302 relay S300-A1A2
2002 - Leach Relay Reliability

Abstract: TDH-6050 TDH-6051 Leach relay M302
Text: POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , Kok, Tai Po, N.T. Hong Kong Tel: (852) 2 191 3830 Fax: (852) 2 389 5803 Featuring LEACH © power and , TIME DELAY RELAY DE-ENERGIZED OUTPUT DETAIL VIEW A ENERGIZED DETAIL VIEW B ALL DIMENSIONS , CONTACTS FOR DC VOLTAGES ABOVE NOMINAL RATING N°101 To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay , contact gap


Original
PDF TDH-6050/6051 MIL-STD-883, 1x10-8 MIL-T-10727 TDH-6050/51 MIL-PRF-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B Leach Relay Reliability TDH-6050 TDH-6051 Leach relay M302
2002 - FLR300

Abstract: m302 relay M300 relay AWG16-18-20 S300-A1B3
Text: B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 MM 2 X2 1 DETAIL 0.9 , FLR300 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay (on operate, on , and comparison. Contact Leach International prior to choosing a component. Date of issue: 3/06 - , . Date of issue: 3/06 - 60 - Page 4 of 4 ENGINEERING DATA SHEET S300, S301, S302 RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC


Original
PDF FLR300 /30mV 28VdC 115Vac/60-400Hz M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 FLR300 m302 relay M300 relay AWG16-18-20 S300-A1B3
2002 - T412 RELAY

Abstract: T412 Leach relay M83536 M400 relay M402 leach Rx 2b relay silicone R140 relay studs a/T412 RELAY Leach relay M400
Text: T412 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 10 AMP Time delay relay on operate or on , Leach International prior to choosing a component. Date of issue: 3/06 - 53 - Page 1 of 4 , and comparison. Contact Leach International prior to choosing a component. Date of issue: 3/06 - , SEE CODE B POSITION, TOLERANCE SEE CODE B FOR M400 RELAY FOR M402 RELAY CODE B S401 15.24 10.16 , 2 X2 1 ± 0,3 ± 0,1 10.16 X1 26.3 15.9 28.2 ± 0.3 FOR M401 RELAY , FOR K COIL


Original
PDF 28Vdc SC400 SC401-1 SC401-2 SC402 T412 RELAY T412 Leach relay M83536 M400 relay M402 leach Rx 2b relay silicone R140 relay studs a/T412 RELAY Leach relay M400
2002 - FLS300

Abstract: Tai Shing relay date code marking Tai Shing date code marking
Text: POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , temperature range. Featuring LEACH © power and control solutions www.esterline.com AMERICAS 6900 , CONTRASTING BEAD .200 TYPICAL CONTRASTING BEAD TIME DELAY RELAY DE-ENERGIZED OUTPUT ENERGIZED , CONTACTS FOR DC VOLTAGES ABOVE NOMINAL RATING N°101 To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay , contact gap


Original
PDF TDH-6060/6061 MIL-STD-883, MIL-T-10727 TDH-6060/61 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 FLS300 Tai Shing relay date code marking Tai Shing date code marking
2002 - Leach relay M83536

Abstract: T412 RELAY m400 leach MIL-PRF-12883 SC402 Leach relay M400 MS27709 silicone R140 M400 relay 2SC4012
Text: SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , DESIGNATION FOR: SERIES M300, M301, M302 , M400, M401, M402, T402, T412 DESIGNED TO THE STANDARDS AND , ±.025mm unless otherwise noted. Featuring LEACH © power and control solutions www.esterline.com , . Date of issue: 3/06 - 35 - Page 1 of 4 SOCKET DIMENSIONS RELAY GASKET SUPPLIED WITH RELAY , of issue: 3/06 - 36 - Page 2 of 4 SOCKET DIMENSIONS GASKET SUPPLIED WITH RELAY RELAY MTG


Original
PDF MIL-PRF-12883/41 M83536, M83726 MS27709 MIL-PRF-12883/40 M83536 MIL-P-46184 ZZ-R-765 MIL-G-45204 SC400 Leach relay M83536 T412 RELAY m400 leach MIL-PRF-12883 SC402 Leach relay M400 silicone R140 M400 relay 2SC4012
2002 - Leach relay M400 d4a

Abstract: M400 relay Leach relay M400 S400-A1B3 T412 relay silicone R140 MS27709
Text: SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , T412 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 10 AMP Time delay relay on operate or on , with J mounting style_| Featuring LEACH © power and control , LEACH © power and control solutions www.esterline.com Data sheets are for initial product selection , FOR M400 RELAY FOR M402 RELAY CODE B S401 15.24 10.16 5.08 3 D 15.24 C 5.08 B A X1 2 X2 1 CODE


Original
PDF 28Vdc SC400 SC401-1 SC401-2 SC402 Leach relay M400 d4a M400 relay Leach relay M400 S400-A1B3 T412 relay silicone R140 MS27709
2002 - F300 relay

Abstract: LEACH RELAY M300 relay F300 Leach VFD300 Leach relay FD370 m302 relay s300 leach leach relay series E M300 leach
Text: B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 MM 2 X2 1 DETAIL 0.9 , FD300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 1 PDT/10 AMP/56VDC Polarized, non latching hermetically sealed relay 1 PDT NC - NO (DB - DM) Contact arrangement Coil supply Direct current PRINCIPLE , . Hermetically sealed, corrosion protected metal can. Intrinsically safe relay . 10 Amps / 56 Vdc 40 grams max. 26 , % rated resistive load Load Current in Amps @56Vdc 10 6 40 Featuring LEACH © power and control solutions


Original
PDF FD300 PDT/10 AMP/56VDC SF300CE40E F300 relay LEACH RELAY M300 relay F300 Leach VFD300 Leach relay FD370 m302 relay s300 leach leach relay series E M300 leach
2002 - Leach relay M83536

Abstract: m400 leach Leach relay M83536 3 PDT M400 relay Leach relay M400 Leach relay M402 M402 relay Leach relay M400 d4a M400-D4A T412 RELAY
Text: SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , T402 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay on operate or on , -Mounting style and terminal types (A,B,C,D)_| Featuring LEACH © power and control , Kok, Tai Po, N.T. Hong Kong Tel: (852) 2 191 3830 Fax: (852) 2 389 5803 Featuring LEACH © power and , S402 3 2 X2 Y1 1 POSITION, TOLERANCE SEE CODE B POSITION, TOLERANCE SEE CODE B FOR M400 RELAY FOR


Original
PDF /30mV 28VdC 115Vac/60-400Hz SC400 SC401-1 SC401-2 SC402 Leach relay M83536 m400 leach Leach relay M83536 3 PDT M400 relay Leach relay M400 Leach relay M402 M402 relay Leach relay M400 d4a M400-D4A T412 RELAY
2002 - TDH-6070

Abstract: m300d fd300 M300 relay S30-1
Text: POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , comparison. Contact Leach International prior to choosing a component. Date of issue: 3/06 - 76 - , NOMINAL RATING N°101 To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay , contact gap, maximum voltage capabilities of the relay contact system, and the contact material. The most common method is to derate the


Original
PDF TDH-6070/6071 MIL-STD-883, 1x10-8 MIL-T-10727 TDH-6070/71 MIL-R-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B TDH-6070 m300d fd300 M300 relay S30-1
2002 - FLR300

Abstract: No abstract text available
Text: M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A , FLR300 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay (on operate, on , ) _| | 6-Accuracy (1,2,3) | Featuring LEACH , /06 - 60 - Page 4 of 4 S300, S301, S302 ENGINEERING DATA SHEET RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC Coil), FD300, FLS300


Original
PDF FLR300 /30mV 28VdC 115Vac/60-400Hz M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 FLR300
2002 - relay m402

Abstract: Leach relay M402 M400 relay Leach relay M83536 3 PDT
Text: _| | | 2-Mating relay (M300, M301, M302 , M400, M401_| | 2-Hardware (0=less hardware, 1 , M402 ENGINEERING DATA SHEET RELAY - LATCH 4 PDT, 10 AMP Polarized, latching hermetically sealed relay Contact arrangement 4 PDT Coil supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS , 115 Vdc - 400 Hz 80 grams max 26 x 25.7 x 26 Intrinsically safe relay CONTACT ELECTRICAL , Vac, 400 Hz 10 8 4 2 60 @115/200 Vac, 400 Hz, 3Ø 10 8 4 2 Featuring LEACH © power and control


Original
PDF SC400 SC401-1 SC401-2 SC402 relay m402 Leach relay M402 M400 relay Leach relay M83536 3 PDT