The Datasheet Archive

Top Results (2)

Part Manufacturer Description Datasheet Download Buy Part
SC63CB-101 Signal Transformer Inc FIXED IND 100UH 860MA 496 MOHM
VDRS20W680BSE Vishay BCcomponents RESISTOR, VOLTAGE DEPENDENT, 895 V, 496 J, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT

Ignitron BK 496 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
Ignitron

Abstract: Ignitron 496 NL-496 Ignitors ignitron tube mercury 1025Y
Text: /\JL y f i? /¿y\/ NATIONAL IGNITRON NL- 496 The NL- 496 is a Size "E" Bath Cooled Ignitron intended primarily for use as a switch in capacitor discharge circuits. GENERAL: Mercury Pool Electronic Tube, Water Cooled Number of Electrodes: Main Anode . 1 Auxiliary Anode . 1 Ignitors . 2 MAXIMUM RATING: Main Anode: Peak Forward or Inverse , Electronics, Ltd. LaFox, IL 60147 • (312)208-2300 NL- 496 IGNITRON


OCR Scan
PDF NL-496 10-25y/sec. Ignitron Ignitron 496 Ignitors ignitron tube mercury 1025Y
arc welder circuit

Abstract: ARC WELDER Ignitron NL1039LP hi-pot pps 30 magnetic pickup dc welder ignitron tube mercury NL103 National Electronics ignitrons
Text: NL1039LP NATIONAL IGNITRON GENERAL CHARACTERISTICS The NL1039LP is a size A, 50,000 volt Ignitron . The data given are specifically for d-c short circuiting service with assumed service condition , °C °C NL1039LP Ignitron PICKUP VOLTAGE An ignitron can begin conduction at voltages as low , of current should be kept below 10kA/µsec if possible. An ignitron does not deteriorate with time , current is normally limited by the circuit parameters and not be the ignitron which has an inductance of


Original
PDF NL1039LP NL1039LP arc welder circuit ARC WELDER Ignitron hi-pot pps 30 magnetic pickup dc welder ignitron tube mercury NL103 National Electronics ignitrons
2008 - Ignitron

Abstract: ignitron tube mercury 1K958-Series 50kV NL-7703 National Electronics ignitrons IG5F2-10 1M2602 ignitron trigger circuit NL7703 National Electronics ignitrons
Text: NL7703EHVNP IGNITRON The NL7703EHVNP ignitron is suitable for use as a switch for either , DETERIORATE IGNITRON LIFE! Notes: 1) To prevent mercury condensation on the anode and anode seals, the anode , from the top portion of the ignitron . 2) Rate of rise depends upon the external circuitry. 3) The , oil. Tube Life Considerations The method used to determine the life expectancy of an ignitron varies , life, the ignitron must be operated at lower levels. Typically, life may be increased 10X if either


Original
PDF NL7703EHVNP NL7703EHVNP 1K1703 Ignitron ignitron tube mercury 1K958-Series 50kV NL-7703 National Electronics ignitrons IG5F2-10 1M2602 ignitron trigger circuit NL7703 National Electronics ignitrons
NL7703

Abstract: Ignitron nl 7171 ignitron 7171 L1039 nl1039 Ignitron NL-7703 Ignitron 7703 NL-1037 National Electronics ignitrons
Text: MOUNTING The performance and life of the ignitron is greatly improved if it is operated in a field free , The ignitron is in high voltage operating can be reduced by using avsriable ac voltage source connected directly condition before leaving the factory. Shipping tends to across the ignitron lignitor not connected). Slowly increase the voltage, redistribute mercury throughout the ignitron making , ignitron (anode than that of the cathode. This is also true during any positive and ignitor not connected


Original
PDF NL-1036 AuAAJ25 4001A NL-1037 L-1039 NL-7703, NL7703H NL-1038 1040tL NL7703 Ignitron nl 7171 ignitron 7171 L1039 nl1039 Ignitron NL-7703 Ignitron 7703 NL-1037 National Electronics ignitrons
2008 - Ignitron

Abstract: 1K958-Series National Electronics ignitrons NL7703 NL7703LP ignitron trigger circuit IG5F2-10 ignitron tube 1K1508P NL-7703
Text: NL7703LP IGNITRON The 7703LP ignitron is suitable for use as a switch for either capacitor , DETERIORATE IGNITRON LIFE! Notes: 1) To prevent mercury condensation on the anode and anode seals, the anode , from the top portion of the ignitron . 2) Rate of rise depends upon the external circuitry. Tube Life Considerations The method used to determine the life expectancy of an ignitron varies according to the , , voltage fluctuation, and load variation. A general rule of thumb: To obtain longer life, the ignitron


Original
PDF NL7703LP 7703LP 1K1703 Ignitron 1K958-Series National Electronics ignitrons NL7703 NL7703LP ignitron trigger circuit IG5F2-10 ignitron tube 1K1508P NL-7703
2008 - Ignitron

Abstract: NL7703EHV ignitron tube NL7703 1K1703 7703EHV 7703E National Electronics ignitrons 1K958-Series ignitron tube mercury
Text: NL7703EHV IGNITRON The 7703EHV ignitron is suitable for use as a switch for either capacitor , DETERIORATE IGNITRON LIFE! Notes: 1) To prevent mercury condensation on the anode and anode seals, the anode , from the top portion of the ignitron . 2) Rate of rise depends upon the external circuitry. Tube Life Considerations The method used to determine the life expectancy of an ignitron varies according to the , , voltage fluctuation, and load variation. A general rule of thumb: To obtain longer life, the ignitron


Original
PDF NL7703EHV 7703EHV 1K1703 Ignitron NL7703EHV ignitron tube NL7703 7703E National Electronics ignitrons 1K958-Series ignitron tube mercury
2008 - Ignitron

Abstract: NL7703 Ignitron* 7703 National Electronics ignitrons NL-7703 Richardson Electronics NL7703 ignitron 7703 ignitron tube mercury ignitor mercury vapor ignitor
Text: NL7703 IGNITRON The 7703 ignitron is suitable for use as a switch for either capacitor , -WARNING! USING SIMULTANEOUS MAXIMUM RATINGS WILL SEVERELY DETERIORATE IGNITRON LIFE! Notes: 1) To prevent , , with respect to the cathode, long enough to remove any mercury from the top portion of the ignitron , determine the life expectancy of an ignitron varies according to the application and it is necessary to , variation. A general rule of thumb: To obtain longer life, the ignitron must be operated at lower levels


Original
PDF NL7703 1K1703 Ignitron NL7703 Ignitron* 7703 National Electronics ignitrons NL-7703 Richardson Electronics NL7703 ignitron 7703 ignitron tube mercury ignitor mercury vapor ignitor
Ignitron

Abstract: welding transformer ignitron trigger circuit 630 kva transformer ignitron tube National Electronics ignitrons welder circuit welder 100 kva transformer welder transformer
Text: NATIONAL SSRI-51 Solid-State Replacement Ignitron The SSRI-51 is a water-cooled silicon , bar and cable to provide a direct ignitron plug in replacement for 2 "B"- size ignitrons. Maximum , (630) 208-2300 General Installation Instructions* (Solid-State Replacement Ignitron ) Remove power to welder. Remove both ignitron tubes and install SSRI unit directly into the tube socket of one of the ignitrons, which we will refer to as original ignitron . Connect ignitor wires (ignitor tulip


Original
PDF SSRI-51 SSRI-51 Ignitron welding transformer ignitron trigger circuit 630 kva transformer ignitron tube National Electronics ignitrons welder circuit welder 100 kva transformer welder transformer
2008 - Ignitron

Abstract: ignitron tube ignitron tube mercury National Electronics ignitrons mercury vapor ignitor anode clip 1K958-Series NL7703 1m2602 ignitron trigger circuit
Text: NL7703LP2 IGNITRON The 7703LP2 ignitron is suitable for use as a switch for either capacitor , DETERIORATE IGNITRON LIFE! Notes: 1) To prevent mercury condensation on the anode and anode seals, the anode , from the top portion of the ignitron . 2) Rate of rise depends upon the external circuitry. Tube Life Considerations The method used to determine the life expectancy of an ignitron varies according to the , , voltage fluctuation, and load variation. A general rule of thumb: To obtain longer life, the ignitron


Original
PDF NL7703LP2 7703LP2 1K1703 Ignitron ignitron tube ignitron tube mercury National Electronics ignitrons mercury vapor ignitor anode clip 1K958-Series NL7703 1m2602 ignitron trigger circuit
2008 - Ignitron

Abstract: NL7703H 1m2602 National Electronics ignitrons ignitor 7703H 1K958-Series ignitron trigger circuit NL-7703 NL7703
Text: NL7703H IGNITRON The 7703H ignitron is suitable for use as a switch for either capacitor , -WARNING! USING SIMULTANEOUS MAXIMUM RATINGS WILL SEVERELY DETERIORATE IGNITRON LIFE! Notes: 1) To prevent , , with respect to the cathode, long enough to remove any mercury from the top portion of the ignitron , determine the life expectancy of an ignitron varies according to the application and it is necessary to , variation. A general rule of thumb: To obtain longer life, the ignitron must be operated at lower levels


Original
PDF NL7703H 7703H 7703H 1K1703 Ignitron NL7703H 1m2602 National Electronics ignitrons ignitor 1K958-Series ignitron trigger circuit NL-7703 NL7703
arc welder circuit

Abstract: Ignitron IGNITOR Z 400 M temp control of water welder circuit IGNITOR Z 400 M k General electric water ignitor welder K903
Text: install IGNITRON Copper terminals Flexible anode lead Mercury-pool cathode allows extremely high , . Arc losses are low. Phase control of the ignitron impulses permits voltage control of the rectified , ANODE FIRING IGNITRON 40 FIG. 3 K-9033528 12-16-44 IGNITOR CURRENT IN AMPERES K-9033529 FIG. 2 , -259-B IGNITRON ; DEMAND CURRENT VS PERCENTAGE DUTY AT 2400 VOLTS RMS, MAX OUTLET WATER TEMP 30 C, K-8074661 MIN , OUTLINE FG-259-B IGNITRON K-5344767 8-10-44 Electronics Department GENERAL % ELECTRIC Schenectady, N


OCR Scan
PDF FG-259-B FG-238-B, 900-volt FG-259-B 2400-volt K-8074661 K-5344767 arc welder circuit Ignitron IGNITOR Z 400 M temp control of water welder circuit IGNITOR Z 400 M k General electric water ignitor welder K903
Ignitron

Abstract: 630 kva transformer welding transformer welder circuit welding rectifier welder transformer welding power transformer welder welding rectifier circuit trigger resistance welding
Text: NATIONAL SSRI-81 Solid-State Replacement Ignitron The SSRI-81 is a water-cooled silicon , mounting buss bar and cable to provide a direct ignitron plug-in replacement for 2 "Jumbo C" size ignitrons , ) 208-2300 kVA General Installation Instructions* (Solid State Replacement Ignitron ) Remove power to welder. Remove both ignitron tubes and install SSRI unit directly into the tube socket of one of the ignitrons, which we will refer to as original ignitron . Connect ignitor wires (ignitor tulip connector


Original
PDF SSRI-81 SSRI-81 Ignitron 630 kva transformer welding transformer welder circuit welding rectifier welder transformer welding power transformer welder welding rectifier circuit trigger resistance welding
arc welder circuit

Abstract: Ignitron control circuit for Welder with ignitron thyratron tube Welder ignitor circuit 400 6 VOLT CD IGNITION welder circuit thyratron IGNITOR Z 400 M
Text: cooling 3. Strong, compact design 4. Easy to install IGNITRON Copper terminals Flexible anode lead , . Arc losses are low. Phase control of the ignitron impulses permits voltage control of the rectified , . 1 FG-238-B ELEMENTARY CIRCUIT FOR ANODE FIRING FUSE RESISTOR THYRATRON IGNITRON T 40 K , -238-B IGNITRON ; DEMAND CURRENT VS PERCENTAGE DUTY AT 2400 VOLTS RMS, MAX. OUTLET WATER TEMP 30 C, MIN WATER RATE 3 GAL/MIN, WELDER CONTROL SERVICE K-8074661 FIG. 5 9-26-44 CUT-AWAY VIEW OF FG-238-B IGNITRON j


OCR Scan
PDF 900-volt FG-238-B 2400-volt 238-B K-8074661 arc welder circuit Ignitron control circuit for Welder with ignitron thyratron tube Welder ignitor circuit 400 6 VOLT CD IGNITION welder circuit thyratron IGNITOR Z 400 M
Ignitron 5551

Abstract: ignitor Ignitron ignitron 5550 Ignitron 5551-A Welder Ignitor 5551
Text:  IGNITRON SIZE B Peak Voltage Drop.12 volte Cooling: ■type.Water Minimum Flow.1 gallon/minute Maximum Outlet Water Temperature.¿0°C minimum Inlet Water Temperature.10°C Pressure Drop per tube, at Min. Flow . . . 1.6 lb./sq.in , TUBE DIVISION TENTAT ! VE. DATA ■ADIO CORPORATION Of AMERICA, HARRISON, NEW JERSEY 5551 IGNITRON , AMEtICA, HAIKiSON, NEW JERSEY TENTATIVE DATA 5551 IGNITRON Fife? -J_ ì PIPE IGNITOR TERMINAL 0.250


OCR Scan
PDF 250-volt 92CS-67I2 CE-6712 Ignitron 5551 ignitor Ignitron ignitron 5550 Ignitron 5551-A Welder Ignitor 5551
Ignitron

Abstract: 630 kva transformer ignitron trigger circuit SSRI-53 welding rectifier welder power ignitron tube ignitron solid state replacement ignitor firing circuit D welding transformer
Text: NATIONAL SSRI-53 Solid-State Replacement Ignitron NATIONAL ELECTRONICS A Division of , State Replacement Ignitron ) Remove power to welder. Remove both ignitron tubes and install SSRI unit directly into the tube socket of one of the ignitrons, which we will refer to as original ignitron , that the original Ignitron Anode Cable was connected to. Turn on water-cooling system. Switch on , from or in connection with the above instructions. SSRI-53 Solid State Replacement Ignitron The


Original
PDF SSRI-53 Ignitron 630 kva transformer ignitron trigger circuit SSRI-53 welding rectifier welder power ignitron tube ignitron solid state replacement ignitor firing circuit D welding transformer
Ignitron

Abstract: arc welder circuit 2A00 thyratron 92CS-6T23
Text: 5554 IGNITRON Cathode.Pool Type Number of Igni tors*. 2 , JERSEY 5554 IGNITRON AC WELDER-CONTROL SERVICE Ratings for à iOO^olts^ms^ 25_to 60_C£Cles Maximum , OF AMERICA, HARRISON, NEW JERSEY 5554 IGNITRON «ADIO COtKNATION Of AMEtKA. HAKtSON. NEW jEKSCY 5554 IGNITRON ELEMENTARY CIRCUIT FOR CAPACITOR FIRING "i _j¡ M ELEMENTARY CIRCUIT FOR ANODE , JEISEV 5554 IGNITRON RADIO CORPORATION OF AMERICA. HA* ti SON, NEW JERSEY


OCR Scan
PDF 10-second 92CS-67 CE-6722-6723 Ignitron arc welder circuit 2A00 thyratron 92CS-6T23
Ignitron

Abstract: NL-5550 ignitron tube mercury ignitron 5550 ignitron tube ignitor Ignitron welding
Text:  IGNITRON TUBE NL-5550 IGNITRON TUBE 22.4 Amperes de NL-5550 is a mercury pool tube designed especially for resistance welding control. Its rating is approximately equivalent to a 150-ampere magnetic contactor. NL-5550 can be used to control 25-60 cycle AC at voltages of 250 to 600 volts. It can also be used to control stored electrostatic energy for resistance welding. NATIONAL ELECTRONICS, Inc. GENEVA, ILLINOIS, U. S. A. NL-5550 IGNITRON TUBE TECHNICAL INFORMATION AC CONTROL APPLICATIONS — ratings are


OCR Scan
PDF NL-5550 150-ampere 80IOO Ignitron ignitron tube mercury ignitron 5550 ignitron tube ignitor Ignitron welding
Ignitron

Abstract: ignitron tube capacitor discharge welder ignitron tube mercury ignitor NL-1001 National Electronics ignitrons ARC WELDER
Text:  IGNITRON TUBE NL-1001 IGNITRON TUBE 9 Amperes de m 111 ■■i NATIONAL IGNITRON NL-1001 is a sturdy, glass, air-cooled mercury pool tube designed especially for welder control and similar AC control applications. It is also useful for demonstrating the operating principles of ignitors and ignitrons. NL-1001 is designed for forced air cooling but may be used with free air cooling at reduced ratings. NATIONAL ELECTRONICS, Inc. GENEVA, ILLINOIS, U. S. A. NL-1001 IGNITRON TUBE TECHNICAL


OCR Scan
PDF NL-1001 Ignitron ignitron tube capacitor discharge welder ignitron tube mercury ignitor National Electronics ignitrons ARC WELDER
Ignitron

Abstract: ,ignitron philips ignitron philips 5822 ignitron 346C T-795 58221 scans-0018001
Text: PHILIPS PL 5822 Water cooled IGNITRON IGNITRON à refroidissement par l'eau Wassergelciihltes IGNITRON Application: Control of frequency-changer resistance welders Application: Réglage des soudeurs à resistance avec transformation de fréquence Anwendung : Regelung von Widerstandsschvveisser mit Fre-quenzumformung Frequency range Gamme de frequences 50 - 60 c/s Frequenzbereich Mounting , provisoires PHILIPS Water cooled IGNITRON IGNITRON à refroidissement par l'eau Wassergeiciihltes IGNITRON


OCR Scan
PDF PL5822 Ignitron ,ignitron philips ignitron philips 5822 ignitron 346C T-795 58221 scans-0018001
ignitron tube

Abstract: Ignitron Welder ignitron tube mercury lighter ignitor ignitor ARC WELDER NL1005
Text:  IGNITRON TUBE NL-1005 IGNITRON TUBE 56 Amperes de NATIONAL IGNITRON NL-1005 is a sturdy, metal, air-cooled mercury pool tube designed especially for welder control and similar AC control applications. It is also useful in some rectifier applications. NL-1005 is designed for forced air cooling but may be used with free air cooling at reduced ratings. NATIONAL ELECTRONICS, Inc. GENEVA, ILLINOIS, U. S. A. NL-1005 IGNITRON TUBE TECHNICAL INFORMATION AC CONTROL APPLICATIONS — Ratings are based on


OCR Scan
PDF NL-1005 ignitron tube Ignitron Welder ignitron tube mercury lighter ignitor ignitor ARC WELDER NL1005
ignitor light

Abstract: ignitor 501 Ignitron NL-1022 ignitor 1022 JEC ELECTRONICS
Text: NL-1022 IGNITRON Size C 70 Amperes dc National Ignitron NL-1022 is a metal, water cooled, mercury pool tube designed especially for frequency-changer resistance welders. NL-1022 baffle reduces the deionization time so that it will operate satisfactorily in applications involving severe conditions of commutation. ÄteJiiiF NL-1022 utilizes an all-copper cooling coil construction with thermostat mount that , NATIONAL ELECTRONICS, Inc. GENEVA, ILLINOIS, U. S. A. NL-1022 IGNITRON 3000 2000 co U te ni & ?


OCR Scan
PDF NL-1022 ignitor light ignitor 501 Ignitron ignitor 1022 JEC ELECTRONICS
Ignitron 5555

Abstract: Ignitron 1200 igniter arc welder circuit ignitron tube
Text: 5555 IGNITRON General: Cathode. Pool type Number of Ignitors •. 2 Number of Main Anodes. 1 Number of Auxiliary Anodes. 1 Peak , , HARRISON, NEW JERSEY 5555 IGNITRON AC WELDER -CONTROL SERVICE Ratings for 2/l00_volts_rms_L _2¿ to , DIVISION TENTATIVE DATA ■AOIO CORPORATION Of AMCRICA, HAHKON. NEW JEISEY 5555 IGNITRON MAX VARIATION , . HARRISON. NEW JERSEY CE-€726 5555 IGNITRON ABC DROP, OUTLET WATER TEMPERATURE—40 °C TO 60 °C


OCR Scan
PDF 92CS-8726 CE-6724 Ignitron 5555 Ignitron 1200 igniter arc welder circuit ignitron tube
PH ON 4006

Abstract: Ignitron pl5555 7Z00 arc welder circuit ignitron 55551 ,ignitron philips 25V1 Ignitron 5555 fp alternatif TW Convertisseur Tension Frequence
Text: Water cooled IGNITRON IGNITRON à refroidissement par l'eau Wassergekühltes IGNITRON , Tentative data.Vorläufige Daten 1. 12.12.1954 Caractéristiques provisoires Water cooled IGNITRON ISNITRON à refroidissement par l'eau Wassergekühltes IGNITRON Application: A.C. control;two tubes in , recommandée 10 °C Empfohlener Wert 10 °0 939 0626 4.4.1956 PHILIPS PL 5555 Water cooled IGNITRON IGNITRON à refroidissement par l'eau Wassergekühltes IGNITRON Application: Power rectification


OCR Scan
PDF S00-900 PL5555 PH ON 4006 Ignitron pl5555 7Z00 arc welder circuit ignitron 55551 ,ignitron philips 25V1 Ignitron 5555 fp alternatif TW Convertisseur Tension Frequence
5551a

Abstract: Ignitron 5551 LA 5530 NE 7555 NL 5551A philips ignitron 5551 Ignitron 5551a thermostat CS- 7 1200 igniter LA 7555
Text: Water cooled IGNITRON with provisions for mounting a thermostatic control unit IGNITRON à , IGNITRON mit Anordnung zur Montierung einer thermostatischen Regelvorrichtung Application: Single and , data.Vorläufige Daten 3. 12.12.1955 Caractéristiques provisoires PHILIPS Water cooled IGNITRON with provisions for mounting a thermostatic control unit IGNITRON à refroidissement par eau avec possibilité de monter un dispositif à commande thermostatique Wassergekühltes IGNITRON mit Anordnung zur liontierung


OCR Scan
PDF RL5551Ã 5551a Ignitron 5551 LA 5530 NE 7555 NL 5551A philips ignitron 5551 Ignitron 5551a thermostat CS- 7 1200 igniter LA 7555
Ignitron

Abstract: ignitron 5550 Ignitron 5552 a SJ 5550
Text: 5550 IGNITRON SIZE A PATA General: Peak Voltage Drop (Approx.).12 volts Cooling : type .Air, or Water-Cooled Clamp Clamp Width (Approx.).1-3/4" Clamp Location.See Outline Drawing Mounting Position.Vertical, Flexible Lead Up llax. Rigid Length (Approx , TENTATIVE DATA RADIO COtPOIATION OF AMI It ICA, HAMIJON, NEW JCtSEY 5550 IGNITRON MAY 1, 1946 TUBE DIVISION RADIO CORPORATION OF AMERICA, HARRISON. NEW JERSEY CE-6713 5550 IGNITRON 1 1 1 1 1 1 1 1


OCR Scan
PDF 92CS-67I6 CE-6716-6715 CE-6714 Ignitron ignitron 5550 Ignitron 5552 a SJ 5550