The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC4257CS8#TR Linear Technology LTC4257 - IEEE 802.3af PD Power over Ethernet Interface Controller; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LTC4257CS8#PBF Linear Technology LTC4257 - IEEE 802.3af PD Power over Ethernet Interface Controller; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LTC4257CS8#TRPBF Linear Technology LTC4257 - IEEE 802.3af PD Power over Ethernet Interface Controller; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LTC4257IDD Linear Technology LTC4257 - IEEE 802.3af PD Power over Ethernet Interface Controller; Package: DFN; Pins: 8; Temperature Range: -40°C to 85°C
LTC4257CDD Linear Technology LTC4257 - IEEE 802.3af PD Power over Ethernet Interface Controller; Package: DFN; Pins: 8; Temperature Range: 0°C to 70°C
LTC4257IS8 Linear Technology LTC4257 - IEEE 802.3af PD Power over Ethernet Interface Controller; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C

IEEE-837 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
EIA-700 AAAB

Abstract: 1-5146896-1 5120521-1 IEEE1386 2-5120527-2 1-5146894-1 EIA-700 IEEE-1386 5120532-1 5146898-1
Text: 8.37 .330 10.37 .408 5.37 .211 7.37 .290 8.37 .330 10.37 .408 Receptacle Part Number 30µ , 8.37 .330 10.37 .408 5.37 .211 7.37 .290 8.37 .330 10.37 .408 Receptacle Part Number 30µ


Original
PDF 64-position 84-position EIA-700 EIA-700 AAAB 1-5146896-1 5120521-1 IEEE1386 2-5120527-2 1-5146894-1 IEEE-1386 5120532-1 5146898-1
2002 - Not Available

Abstract: No abstract text available
Text: 403030.05BB 3/11/02 3:42 PM Page 200 EZ Ground™ Compression Connectors MEETS ® IEEE 837 REQUIREMENTS Pigtail Connectors When connecting cable to ground rod for direct burial or in concrete, the connector shall be wrought copper with min. conductivity of 99% I.A.C.S., such as Thomas & Betts series GR12-306. Hex compression with die code embossing shall be used. • Figure-8 connectors • Hex compression intimately bonds cable directly to ground rod. • Conforms to IEEE std. 837


Original
PDF GR12-306. TBM14M, 3100A TBM15I GR12-306 GR58-406 GR34-4010
2005 - CTP25020

Abstract: 15501a BC4040 CTP202 TBGS-38 TBGS-34 CTP500500 HBKC BC24 B58CS
Text: Blackburn MEETS ® EZ GroundTM Compression Connectors C-Taps Cat. No. A Cable range B Cable range IEEE H ® ® 837 REQUIREMENTS L CTP500500 300 - 500 KCMIL CTP500250 300 - 500 KCMIL CTP50020 300 - 500 KCMIL CTP250250 3/0 STR. - 250 KCMIL CTP25020 3/0 STR. - 250 KCMIL CTP2020 1 STR. - 2/0 , Hex compression intimately bonds cable directly to ground rod. · Conforms to IEEE std. 837 · U.L. 467 MEETS IEEE Cat. No. Cable Range Ground Rod ® ® 837 REQUIREMENTS Die Code for 14- & 15


Original
PDF CTP500500 CTP500250 CTP50020 CTP250250 CTP25020 CTP2020 CTP202 CTP22 15-Ton TBGS-14 15501a BC4040 TBGS-38 TBGS-34 HBKC BC24 B58CS
2002 - Not Available

Abstract: No abstract text available
Text: 403030.05BB 3/11/02 3:42 PM Page 198 EZ Ground™ Compression Connectors Element A g" L D ® Element B MEETS IEEE f" 837 REQUIREMENTS L Figure 6 to 8 Compression Ground Rod to Grid Connectors Dies for TBM14M, 13100A or TBM15I Dimensions (In.) Cat. No. A Ground Rod B Cable Range D L Element A Element B 54855LR12* d" 2 AWG , f" L 837 REQUIREMENTS Figure 6 to 6 Compression Ground Grid Connectors Cat. No. Element A


Original
PDF TBM14M, 3100A TBM15I 54855LR12* AWG-250 15G86R 15G121R 54885LR12* kcmil-500 15G126R
2005 - u1011

Abstract: burndy high ground CTP25020 burndy Y35 manual 54875LR34 15G126R burndy Y46 15500KD34 U997 burndy Y750
Text: IEEE 837 REQUIREMENTS MAIN H TAP T Material : high conductivity copper. Acceptable , Connectors Figure 8 Compression for Copper Ground Rod Tap Connectors MEETS ® IEEE 837 REQUIREMENTS , Connectors Figure 6 to 6 Compression Ground Grid Connectors ELEMENT A MEETS IEEE 837 REQUIREMENTS , 8 Compression Ground Rod to Grid Connectors IEEE 837 REQUIREMENTS ELEMENT A 7/8" L D , Cable range IEEE H 837 REQUIREMENTS L CTP500500 CTP500250 CTP50020 CTP250250 CTP25020


Original
PDF 54865CK IEE837 u1011 burndy high ground CTP25020 burndy Y35 manual 54875LR34 15G126R burndy Y46 15500KD34 U997 burndy Y750
2009 - Not Available

Abstract: No abstract text available
Text: 8.37 .330 10.37 .408 5.37 .211 7.37 .290 8.37 .330 10.37 .408 Receptacle Part Number


Original
PDF EIA-700
2002 - Not Available

Abstract: No abstract text available
Text: described in IEEE 837 standard for qualifying permanent connections used in substation grounding. The connectors conform to the following IEEE Standard 837 requirements: • 350°C current cycling â


Original
PDF IEEE837, UL467,
2009 - 5120523-2

Abstract: No abstract text available
Text: 7.37 .290 8.37 .330 10.37 .408 5.37 .211 7.37 .290 8.37 .330 10.37 .408 Receptacle Part


Original
PDF EIA-700 5120523-2
2005 - burndy Y35 crimping tool manual

Abstract: burndy Y35 operation manual burndy Y35 user manual burndy compression die index csa 26 burndy Y46 operation manual TBM14 TB cable lug catalogue FBC21-1 IEEE-837 Burndy Y35 service manual
Text: IEEE 837 standard for qualifying permanent connections used in substation grounding. The connectors conform to the following IEEE Standard 837 requirements: · 350°C current cycling · Freeze-thaw test · , # 837 , UL #467, CSA 22.2). Connectors are pre-filled with oxide inhibitors and sealed. 1 2 3 4 5 6 7 , * ITEM 1 MEETS H IEEE L 837 REQUIREMENTS Material : high conductivity copper. Acceptable , ITEM 2 MEETS IEEE 7/8" T 837 REQUIREMENTS Cat No. GR1-300500 GR34-300500 GR58-300500 GR1


Original
PDF GG500-350 GG500-40250 GG500-500 GP2250-2 GP2250-4 GP250500-2 GP250500-4 GR1-202 GR12-202 GR12-202TP burndy Y35 crimping tool manual burndy Y35 operation manual burndy Y35 user manual burndy compression die index csa 26 burndy Y46 operation manual TBM14 TB cable lug catalogue FBC21-1 IEEE-837 Burndy Y35 service manual
EIA-700 AAAB

Abstract: 5120521-1 5120532-1
Text: 34.4 1.354 44.4 1.748 H 5.37 .211 7.37 .290 8.37 .330 10.37 .408 5.37 .211 7.37 .290 8.37 .330 10.37 .408 Receptacle Part Number 30µ" Au Plating 50µ" Au Plating w/o pickup , 1.347 44.22 1.741 H 35.9 1.413 45.9 1.807 5.37 .211 7.37 .290 8.37 .330 10.37 .408 5.37 .211 7.37 .290 8.37 .330 10.37 .408 Receptacle Part Number 30µ" Au Plating 50µ


Original
PDF EIA-700 EIA-700 AAAB 5120521-1 5120532-1
2002 - Not Available

Abstract: No abstract text available
Text: 403030.05BB 3/11/02 3:42 PM Page 197 EZ Ground™ Compression Connectors H Main ® MEETS Tap IEEE 837 REQUIREMENTS T Figure 6 Compression Ground Tap Connector Cable to Rebar Application A Ground Rod B Cable Range Application Cat. No. Main Tap 54855 1/0 STR. - .250 kcmil or 1/2" - 5/8" ROD 1/0 STR. - .250 kcmil or 1/2" - 5/8" ROD 1/0 STR. - 250 , ground rods. Add suffix -TP B ® MEETS IEEE 837 REQUIREMENTS T Figure 8 Compression


Original
PDF 54865-CK 15G121R GR1-202 GR12-40250 AWG-250 GR58-40250
AMP 120521-1

Abstract: No abstract text available
Text: 8.37 .330 120603-1 120523-1 10.37 .408 5.37 ?11 41.0 1.614 44.22 1.741 45.9 1.607 44.4 1.748 120524-1 120521-2 7.37 ,290 8.37 .330 10.37 .408 120603-2 1


OCR Scan
PDF 000050J EIA-700 S23-2 AMP 120521-1
AAAB

Abstract: EIA-700 AAAB
Text: 34.22 '1.347 35.9 1.413 7.37 .290 8.37 .330 10.37 .408 5.37 .211 84 41.0 1.614 44.22 '1.741 45.9 1.807 7.37 .290 8.37 .330 10.37 .408 Notes: 1. Shorter solder lands may be used per


OCR Scan
PDF EIA-700 AAAB EIA-700 AAAB
120521-1

Abstract: No abstract text available
Text: 120524-2 64 31.0 1.220 34.22 1.347 35.9 1.413 34.4 1.354 7.37 .290 8.37 .330 10.37 .408 5.37 .211 84 41.0 1.614 44.22 1.741 45.9 1.807 44.4 1.748 7.37 .290 8.37 .330 10.37


OCR Scan
PDF EIA-700 120521-1
TIA-329

Abstract: No abstract text available
Text: applications. Models are also available for Trunking 837 MHz and ISM 915 MHz modems. A single band model is , -925/1800 CVS-925/1900 CVS- 837 /1900 CVS-900/1800 Band(s) US GSM/GPRS/EV-DO, 850/1900 EU GSM 900


Original
PDF RG-174 EN61373, MIL-810G TIA-329 3900-B
Penetrox A Electric Joint Compound

Abstract: Penetrox E Electric Joint Compound u1011 Burndy Y35 hypress burndy YGIB Bus Bar torque for metric bolts UL467 YGHC29C29 U997 PIBEAMKIT
Text: requirements of Standard IEEE 837 latest revision. Meets tough industry performance requirements , . CATALOG NUMBER YGL2C2 YGL29C2 YGL29C29 YGL34C2 YGL34C29 YGL34C34 MEETS ALL IEEE 467 837 , embossed with appropriate PRECRIMPTM die. For connections that must meet IEEE 837 requirements UPRECRIMPTM , 498.8 kcmil (.810 Dia.) MEETS ALL IEEE 837 REQUIREMENTS GROUND ROD DIA. ELEMENT "B" B , . For connections that must meet IEEE 837 requirements UPRECRIMPTM - type PRE crimp dies must be used


Original
PDF GP654CG1 GP64526G1 GP1526G1 GP1726RT Penetrox A Electric Joint Compound Penetrox E Electric Joint Compound u1011 Burndy Y35 hypress burndy YGIB Bus Bar torque for metric bolts UL467 YGHC29C29 U997 PIBEAMKIT
2002 - Not Available

Abstract: No abstract text available
Text: 403030.05BB 3/11/02 3:42 PM Page 203 EZ Ground™ Compression Connectors MEETS ® IEEE 837 REQUIREMENTS Ground Plates Cat. No. Cable Range H Dies 1 2-250 kcmil 3e" 15G86R GP2250-4 2 2-250 kcmil 4r" 15G126R GP250500-2 1 250-500 kcmil 3e" 15G86R GP250500-4 1f Figure GP2250-2 2 250-500 kcmil 4r" 15G126R 2X d-13 UNC 3b 2 1f 4X d-13 UNC 5A 1 3/4 c-16 UNC c-16 UNC H H Cable Range


Original
PDF 15G86R GP2250-4 15G126R GP250500-2 GP250500-4 GP2250-2
2002 - amerductor

Abstract: amerductor wire UL 467 tables for grounding UL467 IEEE837 UL 467 96 GP114 blackburn cast bronze conduit hub NEC250 TBM15I IEEE-837
Text: described in IEEE 837 standard for qualifying permanent connections used in substation grounding. The connectors conform to the following IEEE Standard 837 requirements: · 350°C current cycling · Freeze-thaw , Grounding EZ GroundTM Compression Connectors H Main ® MEETS Tap IEEE 837 REQUIREMENTS , . Add suffix -TP B H ® A MEETS IEEE 837 REQUIREMENTS T Figure 8 Compression , f" 837 REQUIREMENTS L Blackburn ® F Figure 6 to 8 Compression Ground Rod to Grid


Original
PDF F87-F93, F95-F99 F101-F102, F103-F105 F108-F114 amerductor amerductor wire UL 467 tables for grounding UL467 IEEE837 UL 467 96 GP114 blackburn cast bronze conduit hub NEC250 TBM15I IEEE-837
1995 - round robin bus arbitration

Abstract: arbitration scheme FUTUREBUS 1 am6 ab-7 national DS3884A DS3886A PAL16L8 PAL20L8 C1995
Text: National Semiconductor Application Note 837 Shilpa Parikh July 1992 IEEE 896 1 Futurebus a Standard specifies two arbitration protocols Distributed Arbitration and Central Arbitration Each arbitration scheme has its merits and drawbacks First a brief summary of both arbitration methodologies is , RR GA4 GA3 GA2 GA1 GA0 Two Pass Arbitration Number AN- 837 C1995 National , APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION As used herein AN- 837 1 Life support


Original
PDF
2011 - BC4040

Abstract: No abstract text available
Text: Notes Does not meet IEEE 837 Requirements. For further technical assistance, please contact us. T&B


Original
PDF BC4040 TBM14M, 3100A, TBM15I 3B-50 BC4040
2011 - BC48

Abstract: No abstract text available
Text: IEEE 837 Requirements. For further technical assistance, please contact us. T&B Technical Support MS


Original
PDF TBM14M, 3100A, TBM15I P13100A, 3B-50 BC48
2002 - Not Available

Abstract: No abstract text available
Text: 403030.05BB 3/11/02 3:42 PM Page 202 EZ Ground™ Compression Connectors MEETS ® IEEE 837 REQUIREMENTS I Beam Ground Clamp I-beam ground clamp for connecting ground cable to I-beam, or any 1" max. structural steel member without welding or drilling. Breakaway bolt head shears at predetermined torque to assure tight connection. Heavy duty compression lug provides excellent current carrying capabilities. Surface of steel must be cleaned in accordance with the installation


Original
PDF TBM15I IBG2-10 NEC250-81
2011 - ground rod

Abstract: No abstract text available
Text: T&B Catalog Number: UPC Number: Description: 54865L 78621017987 E-Z-Ground Figure 6-6 Copper Compression Ground Grid Connector for Cable Range #1 Str.-250 kcmil, Ground Rod 1/2 - 5/8 Active Status: Features - E-Z-Ground connectors are designed for direct burial and offer a Figure 6-6 Copper #1 Str.-250 kcmil #1 Str.-250 kcmil #6 Sol.-#2 Str. 1/2 - 5/8 3/8 - 1/2 #3-#4 Rebar 7/8 3/4 Available on Website TBM14M, 13100A, TBM15I 1 25 Each 47 lbs. per 100 msds-0085-tb2 Available on Website Meets IEEE 837


Original
PDF 54865L TBM14M, 3100A, TBM15I msds-0085-tb2 3B-50 ground rod
2011 - Not Available

Abstract: No abstract text available
Text: Notes Does not meet IEEE 837 Requirements. For further technical assistance, please contact us. T&B


Original
PDF BC2020-BB TBM14M, 3100A, TBM15I S13100A, 3B-50
2011 - CTP2020

Abstract: No abstract text available
Text: T&B Catalog Number: UPC Number: Description: CTP2020 78621033108 E-Z-Ground C-Taps Copper Compression Connector for Cable Range #1 Str. - 2/0 Str., Tap #1 Str. - 2/0 Str. Active Status: Features - E-Z-Ground connectors are designed for direct burial and offer a C-Taps Copper #1 Str. - 2/0 Str. #1 Str. - 2/0 Str. #1 Str. - 2/0 Str. 1 1.54 .75 Available on Website TBM14M, 13100A, TBM15I 1 25 Each 20 lbs. per 100 Available on Website Meets IEEE 837 Requirements. (R) General -Style


Original
PDF CTP2020 TBM14M, 3100A, TBM15I 155XX 3B-50 CTP2020