The Datasheet Archive

IEC61558 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
IEC61558-1

Abstract: IEC61558 enclosure RAL7035 EN61558-1 IEC61558-2-13 RAL7032 transformer 400V EN61558
Text: transformers - Conforms to EN61558-1 / IEC61558-1 , and EN61558-2-13 / IEC61558-2-13 mm mm mm mm


Original
PDF TRD14 RAL7035) RAL7032) IEC61558-1 IEC61558 enclosure RAL7035 EN61558-1 IEC61558-2-13 RAL7032 transformer 400V EN61558
2013 - wurth max inverter 160

Abstract: 100 kHz flyback transformer tda4863 equivalent Non - Isolated Buck, triac dimmable WURTH CATALOG TPS92070 NCL30082
Text: : Reinforced insulation ■Standards detail: IEC61558-2-17 ■Operating temperature , voltage: 4500VAC ■Safety: Reinforced insulation ■Standards detail: IEC61558-2-17 , – Standards detail: IEC61558-2-17 ■Operating temperature: -40°C to +125°C , Agencies: ❏ IEC61558 Insulation Requirements: ❏ Functional ❏ Basic ❏ Supplementary â


Original
PDF
74090

Abstract: transformer for TNY253 IC 74090 tny253 myrra E16 transformer transformer e16 E16 10 pin transformers data sheet of 12v transformer IEC61558
Text: TRANSFORMER FOR TINYSWITCH · · · · · SIZE E16 · SINGLE OUTPUT : 5 or 12v Primary / Secondary Insulation 4000V Creepage distance Primary / Secondary 6mm Ambient temperature < 85°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation Exclusively uses UL94-V0 listed materials 0V DRAIN +E +S1 Pin 3 Removed PCB Drilling Diameter = 1.1mm Bottom View (Pin side) Windings MYRRA P/N Output Power maximum 74090 1.5 w Pri S1 5­2 16 3.3 ­ 6 Vdc


Original
PDF IEC950, IEC335, IEC61558 UL94-V0 TNY253 265Vrms 44kHz 74090 transformer for TNY253 IC 74090 tny253 myrra E16 transformer transformer e16 E16 10 pin transformers data sheet of 12v transformer
VDE0570

Abstract: IEC61558 insulated copper wire 0.5mm
Text: the requirements of: EN61558 Class II, Non-inherently Short-Circuit Proof VDE0570 Class II IEC61558


Original
PDF 20-Aug-2009 105VA 50/60Hz 81605-P1S1 EN61558 VDE0570 IEC61558 UL506 insulated copper wire 0.5mm
2012 - IEC61558-2-17

Abstract: WE-MIDCOM 750-81
Text: including temp rise. Designed to comply with the following requirements as defined by IEC61558-2-17 : -


Original
PDF 375VDC 170kHz 12VDC, 13VDC, 20mADC 200mADC 4500VAC, 4500VAC 100kHz, 100mVAC, IEC61558-2-17 WE-MIDCOM 750-81
TNY266

Abstract: myrra tny266 transformer 74014 TNY266 application E16 10 pin transformers TNY266 Power Integrations IEC335 12 pin flyback transformer myrra E16
Text: FLYBACK TRANSFORMER SIZE E16 · 2 OUTPUTS : 2 x 24v · · · · · · Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation Exclusively uses UL94-V0 listed materials +E +S2 0V +S1 0V DRAIN +AUX 0V 74014 PIN 3 Removed PCB Drilling Diameter = 1.1mm Bottom View (Pin side) Windings MYRRA P/N Output Power


Original
PDF IEC950, IEC335, IEC61558 UL94-V0 TNY266 265Vrms OP242P TNY266 myrra tny266 transformer 74014 TNY266 application E16 10 pin transformers TNY266 Power Integrations IEC335 12 pin flyback transformer myrra E16
el19 transformer

Abstract: TOP243P myrra el19 74023 10 pin flyback transformer Diodes S4 flyback transformer construction 12 pin flyback transformer Integrations
Text: FLYBACK TRANSFORMER · · · · · · SIZE EL19 · 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 60°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation Exclusively uses UL94-V0 listed materials 1 0v +S1 6 7 +S2 5 +Aux 8 +S3 4 DRAIN 9 +S4 3 10 +S5 2 E 0V 74023 Bottom View (Pin side) PCB


Original
PDF IEC950, IEC335, IEC61558 UL94-V0 OP243P 265Vrms 132kHz el19 transformer TOP243P myrra el19 74023 10 pin flyback transformer Diodes S4 flyback transformer construction 12 pin flyback transformer Integrations
IEC61558-2-17

Abstract: WE-MIDCOM 4000VAC IEC61558 5000VAC 450uH
Text: ), ( 10.8 ):( 1 ), ±2%. Designed to comply with the following requirements as defined by IEC61558-2-17


Original
PDF 20-375V 66kHz 300mA 4000VAC, 5000VAC 500VAC, 625VAC 10kHz, IEC61558-2-17 WE-MIDCOM 4000VAC IEC61558 450uH
50va transformer

Abstract: 81604-P1S1 IEC61558 VDE0570 insulated copper wire 0.5mm
Text: the requirements of: EN61558 Class II, Non-inherently Short-Circuit Proof VDE0570 Class II IEC61558


Original
PDF 20-Aug-2009 50/60Hz 81604-P1S1 EN61558 VDE0570 IEC61558 UL506 150mm 50va transformer 81604-P1S1 insulated copper wire 0.5mm
WE-MIDCOM

Abstract: WE MIDCOM IEC61558-2-17 WE-MIDCOM transformer IEC61558
Text: requirements as defined by IEC61558-2-17 : - Reinforced insulation for a primary circuit at a working voltage


Original
PDF 20-375V 100kHz 360mA 4500VAC, 4500VAC 500VAC, 625VAC 10kHz, 100mVAC, 400mA WE-MIDCOM WE MIDCOM IEC61558-2-17 WE-MIDCOM transformer IEC61558
TNY266

Abstract: 74015 12 pin flyback transformer POWER INTEGRATIONS tny266 transformer IC 74015 myrra TNY266 Power Integrations TNY266 application TOP242P
Text: FLYBACK TRANSFORMER · · · · · · SIZE E16 · 3 OUTPUTS : 5 / 15 / 24v Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation Exclusively uses UL94-V0 listed materials +E +S3 +S2 +S1 0V DRAIN +AUX 0V 74015 PIN 3 Removed PCB Drilling Diameter = 1.1mm Bottom View (Pin side) Windings MYRRA P/N


Original
PDF IEC950, IEC335, IEC61558 UL94-V0 TNY266 265Vrms OP242P TNY266 74015 12 pin flyback transformer POWER INTEGRATIONS tny266 transformer IC 74015 myrra TNY266 Power Integrations TNY266 application TOP242P
WE-MIDCOM

Abstract: IEC61558-2-17
Text: IEC61558-2-17 : - Reinforced insulation for a primary circuit at a working voltage of 400VDC. OPERATING


Original
PDF 20-375V 132kHz 330mA 4500VAC, 4500VAC 500VAC, 625VAC 10kHz, WE-MIDCOM IEC61558-2-17
WE-MIDCOM

Abstract: WE MIDCOM IEC61558-2-17 Midcom IEC61558 WE-MIDCOM transformer WE-MIDCOM transformer 750871035
Text: temp rise. C C Designed to comply with the following requirements as defined by IEC61558-2-17 : -


Original
PDF 390VDC 100kHz 12VDC, 45ADC 15VDC, 30mADC 4500VAC, 4500VAC 10kHz, 100mVAC, WE-MIDCOM WE MIDCOM IEC61558-2-17 Midcom IEC61558 WE-MIDCOM transformer WE-MIDCOM transformer 750871035
2011 - WE-MIDCOM

Abstract: IEC61558-2-17
Text: including temp rise. Designed to comply with the following requirements as defined by IEC61558-2-17 : -


Original
PDF 375VDC 132kHz 12VDC, 13VDC, 20mADC 200mADC 4500VAC, 4500VAC 100kHz, 100mVAC, WE-MIDCOM IEC61558-2-17
IEC61558-2-17

Abstract: WE-MIDCOM
Text: Designed to comply with the following requirements as defined by IEC61558-2-17 : - Reinforced insulation


Original
PDF 20-375V 300kHz 300mA 4500VAC, 4500VAC 1000VAC, 1250VAC 10kHz, 100mVAC, 650mA IEC61558-2-17 WE-MIDCOM
2012 - IEC61558-2-16

Abstract: WE-MIDCOM
Text: requirements as defined by IEC61558-2-16 : - Reinforced insulation for a primary circuit at a working voltage of


Original
PDF 375VDC 70kHz 40VDC, 14VDC, 20mADC 4500VAC, 4500VAC 70kHz, 100mVAC, 100kHz, IEC61558-2-16 WE-MIDCOM
toroidal transformer p1s2

Abstract: IEC61558 VDE0570 81548-P1S2
Text: , Non-Short-Circuit Proof VDE0570 Class II IEC61558 Class II UL506 Physical Data Approximation Dimension


Original
PDF 30-Dec-2009 120VA 50/60Hz 81546-P1S2 81547-P1S2 81548-P1S2 81549-P1S2 81550-P1S2 EN61558 VDE0570 toroidal transformer p1s2 IEC61558 81548-P1S2
winding wire

Abstract: 81541 40VA 80VA IEC61558 VDE0570 toroidal transformer toroidal transformer p1s2
Text: II IEC61558 Class II UL506 Physical Data Approximation Dimension Approximate weight


Original
PDF 30-Dec-2009 50/60Hz 81540-P1S2 81541-P1S2 81542-P1S2 81543-P1S2 81544-P1S2 EN61558 VDE0570 IEC61558 winding wire 81541 40VA 80VA toroidal transformer toroidal transformer p1s2
40VA

Abstract: 80VA IEC61558 VDE0570 Toroidal transformer P2S2
Text: Class II, Non-Short-Circuit Proof VDE0570 Class II IEC61558 Class II UL506 Physical Data


Original
PDF 30-Dec-2009 2x115V 2x115V 50/60Hz 81581-P2S2 81582-P2S2 81583-P2S2 81584-P2S2 671-d EN61558 40VA 80VA IEC61558 VDE0570 Toroidal transformer P2S2
8 pin e25 transformer

Abstract: 74032 TOP244Y TOP244P IC 74032 flyback transformer 74030 VIPER50 application note TOP244Y application TOP244P IC myrra
Text: FLYBACK TRANSFORMER SIZE E25 · 3 or 1 OUTPUTS : 5+12/12v or 24v · · · · · · Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation Exclusively uses UL94-V0 listed materials +E +S2 +S1 0V +S3 0V DRAIN +AUX 0V 74030 +E +S1 DRAIN +AUX 0V 0V 74032 Bottom View (Pin side) PIN 4 Removed PCB


Original
PDF 12/12v IEC950, IEC335, IEC61558 UL94-V0 OP244P 265Vrms 132kHz OP244Y 8 pin e25 transformer 74032 TOP244Y TOP244P IC 74032 flyback transformer 74030 VIPER50 application note TOP244Y application TOP244P IC myrra
81566-P2S2

Abstract: transformer EN61558 IEC61558 VDE0570 P2S2 81564-P2S2
Text: requirements of: EN61558 Class II, Non-Short-Circuit Proof VDE0570 Class II IEC61558 Class II UL506


Original
PDF 30-Dec-2009 2x115V 2x115V 50/60Hz 81563-P2S2 81564-P2S2 81565-P2S2 81566-P2S2 671-d EN61558 81566-P2S2 transformer EN61558 IEC61558 VDE0570 P2S2 81564-P2S2
EF20 TRANSFORMER

Abstract: TNY268 APPLICATION NOTE TOP243P TNY268 74081 POWER INTEGRATIONS tny268 Transformer myrra 74082 EF20 6 8
Text: FLYBACK TRANSFORMER SIZE EF20 · 2 or 3 OUTPUTS : 5/5v or 12/12v or 3.3+5/12v · · · · · Primary / Secondary Insulation 4000V · Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 8mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation Exclusively uses UL94-V0 listed materials +E +S1 0V DRAIN +AUX 0V +S2 0V 74080 - 74082 +S2 +S1 0V +S3 0V +E DRAIN +AUX 0V 74081 Bottom View (Pin side) PIN 3 Removed


Original
PDF 12/12v 5/12v IEC950, IEC335, IEC61558 UL94-V0 OP243P 265Vrms 132kHz EF20 TRANSFORMER TNY268 APPLICATION NOTE TOP243P TNY268 74081 POWER INTEGRATIONS tny268 Transformer myrra 74082 EF20 6 8
IEC61558

Abstract: VDE0570 winding wire 671-8924 toroidal transformer p1s2
Text: Proof VDE0570 Class II IEC61558 Class II UL506 Physical Data Approximation Dimension


Original
PDF 30-Dec-2009 50/60Hz 81523-P1S2 81524-P1S2 81525-P1S2 81526-P1S2 81527-P1S2 EN61558 VDE0570 IEC61558 winding wire 671-8924 toroidal transformer p1s2
74003

Abstract: 74001 74000 adc datasheets E16 74000 74002 7400-1 IEC335 IEC61558
Text: Size 44 E16 · 2 Outputs: 5 & 12V, Single Output: 5 or 12V · Primary / Secondary Insulation > 4000V · Primary / Auxiliary Insulation > 1500V · Creepage distance Primary / Secondary > 6mm · Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation · Exclusively uses UL94-V0 listed materials 2 Outputs Dual Output 74000 74003 Single Output PIN 3 Removed PCB Drilling Diameter = 1.1mm 74001, 74002 Part No. 74000 5w Windings Output Power Maximum 74002


Original
PDF IEC950, IEC335, IEC61558 UL94-V0 74003 74001 74000 adc datasheets E16 74000 74002 7400-1 IEC335
TNY254

Abstract: TNY254 equivalent myrra 74093 transformer e16 data sheet of 12v transformer IEC335 IEC950 E16 10 pin transformers Power Integrations
Text: TRANSFORMER FOR TINYSWITCH SIZE E16 · SINGLE OUTPUT : 5 or 12v · · · · · Primary / Secondary Insulation 4000V Creepage distance Primary / Secondary 6mm Ambient temperature < 70°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation Exclusively uses UL94-V0 listed materials 0V DRAIN +E +S1 Bottom View (Pin side) Pin 3 Removed PCB Drilling Diameter = 1.1mm Windings MYRRA P/N Output Power maximum 74092 3.1 w Pri S1 5­2 13 3.3


Original
PDF IEC950, IEC335, IEC61558 UL94-V0 TNY254 265Vrms 44kHz TNY254 TNY254 equivalent myrra 74093 transformer e16 data sheet of 12v transformer IEC335 IEC950 E16 10 pin transformers Power Integrations
Supplyframe Tracking Pixel