The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
TRS232NS Texas Instruments Dual RS-232 Driver/Receiver With IEC61000-4-2 Protection 16-SO 0 to 70
TRS232NSR Texas Instruments Dual RS-232 Driver/Receiver With IEC61000-4-2 Protection 16-SO 0 to 70
MAX232ECPWRG4 Texas Instruments Dual RS-232 Driver/Receiver with IEC61000-4-2 Protection 16-TSSOP 0 to 70
MAX232EINE4 Texas Instruments Dual RS-232 Driver/Receiver with IEC61000-4-2 Protection 16-PDIP -40 to 85
TRS232D Texas Instruments Dual RS-232 Driver/Receiver With IEC61000-4-2 Protection 16-SOIC 0 to 70
TRS232ECDWR Texas Instruments Dual RS-232 Driver/Receiver With IEC61000-4-2 Protection 16-SOIC 0 to 70

IEC61000-4-2 datasheet (1)

Part Manufacturer Description Type PDF
IEC61000-4-2 SGS-Thomson Transient Voltage Suppressor Original PDF

IEC61000-4-2 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2005 - 5V TVS SMBJ5.0A

Abstract: SMBJ12AV USBDF02 USBLC6-2SC6 USBLC6-2P6 STPS3100 usblc6-4sc6 SMYT18AM SMBJ12AVCL SM2T3V3A
Text: -666 packages (compliant with IEC61000-4-2 , level 4) No signal distortion Protecting Bus switch VBUS , IEC61000-4-2 KDAT KCLK KBMF 01SC6 MDAT MCLK KBMF 01SC6 (±15kV air and contact discharge , Part number +/-15kV air and +/-8kV contact discharge ESD protection (compliant with IEC61000-4-2 , protection QSOP28 package QSOP28 Benefits Complies with FCC part 15 (EMI) and IEC61000-4-2 (15kV , air and +/-8kV contact discharge ESD protection (compliant with IEC61000-4-2 , level 4) Low


Original
PDF IEEE1284 IEEE1394a/b BRMLDCOMP0605 5V TVS SMBJ5.0A SMBJ12AV USBDF02 USBLC6-2SC6 USBLC6-2P6 STPS3100 usblc6-4sc6 SMYT18AM SMBJ12AVCL SM2T3V3A
2004 - byw50

Abstract: stps10 triac degaussing tv circuit degaussing STTH6002C BYW50-18 VGA portable dvd player PKC136 ESDA6V1L usblc6-4sc6
Text: to IEC61000-4-2 level 4 Wide frequency range rejection Suitable for high data rate exchanges T , capacitance SOT-23 packages ESDA6V1-4BC6 ESDA5V3SC6 Benefits Complies with IEC61000-4-2 level 4 , Complies with FCC part 15 (EMI) and IEC61000-4-2 (15kV ESD protection) Part number Rs () R1 (k , .1 termination Replaces eight discretes Complies with CISPR022 (EMI) and IEC61000-4-2 (15kV ESD protection , /-15kV air discharge ESD protection ( IEC61000-4-2 , level4) Low profile SOT23-6L integrated packages


Original
PDF OT23-6L FLASDCONS/0104 byw50 stps10 triac degaussing tv circuit degaussing STTH6002C BYW50-18 VGA portable dvd player PKC136 ESDA6V1L usblc6-4sc6
2011 - 17L50

Abstract: 567CX-01 WLCSP
Text: Figure 3. ESD Clamping Voltage Screenshot Positive 8 kV Contact per IEC61000-4-2 , CEC line Figure 4. ESD Clamping Voltage Screenshot Negative 8 kV Contact per IEC61000-4-2 , CEC line Figure 5. ESD Clamping Voltage Screenshot Positive 8 kV Contact per IEC61000-4-2 , SCL line Figure 6. ESD Clamping Voltage Screenshot Negative 8 kV Contact per IEC61000-4-2 , SCL line Figure 7. ESD Clamping Voltage Screenshot Positive 8 kV Contact per IEC61000-4-2 , SDA line Figure 8. ESD Clamping Voltage Screenshot


Original
PDF ESD5384 567CX ESD5384/D 17L50 567CX-01 WLCSP
2011 - Not Available

Abstract: No abstract text available
Text: Footprint: 1.6 mm x 1.1 mm Package 0.4 mm Pitch WLCSP Package IEC61000-4-2 Level 4 (At External Pins) ± 15 , ESD IEC61000-4-2 , level 4 ­ air discharge (external pins) ESD IEC61000-4-2 , level 4 ­ contact , Clamping Voltage Screenshot Positive 8 kV Contact per IEC61000-4-2 Figure 6. ESD Clamping Voltage Screenshot Negative 8 kV Contact per IEC61000-4-2 http://onsemi.com 3 ESD7484 IEC61000-4-2 Spec , at 60 ns (A) 2 4 6 8 I @ 60 ns 10% tP = 0.7 ns to 1 ns I @ 30 ns IEC61000-4-2 Waveform Ipeak 100% 90


Original
PDF ESD7484 1394a 1394b/c, WLCSP10 567DE ESD7484/D
2014 - Not Available

Abstract: No abstract text available
Text: clamping voltages. Pinout and Functional Block Diagram Features • ESD, IEC61000-4-2 ,  , Min 0.22 Ω 30.0 A IEC61000-4-2 (Contact Discharge) ±30 kV IEC61000-4-2 (Air , =8/20µs Ω 17 .0 A IEC61000-4-2 (Contact Discharge) ±30 kV IEC61000-4-2 (Air , =8/20µs, Fwd VC VESD Max 0.34 V Ω 12.0 A IEC61000-4-2 (Contact Discharge) ±30 kV IEC61000-4-2 (Air Discharge) ±30 kV Reverse Bias=0V, f=1MHz 100 pF Max


Original
PDF IEC61000-4-5) IEC61000-4-2, OD323
DF2S6.8FS

Abstract: DF6A6.8FU DF2S5.6FS esm 231 DF3A3.3FE SC-81 DF2S16FS DF2S12FU DF2S12FS DF3A8.2FU
Text: 1006 2 1212 3 1616 5 61000-4-2 ±8 k 36.8 IEC61000-4-2 , : ±25 kV : ±30 kV 5.6 6.8 V: ±8 kV 8.2 V: ±6 kV IEC61000-4-2 DF5AxxLF 12 V: ±20 kV 24 , 1 fSC Vz(V) (@Iz = 5 mA) ESD CT(pF) (@VR = 0 V) IEC61000-4-2 USC , IEC61000-4-2 Min Min Typ. Max Typ. 3.3 V 3.1 3.3 3.5 115 3.6 V 3.4 , .2FU DF5A8.2F - - 6 HighSpeed HighSpeed20 pF IEC61000-4-2 ±15 kV 3.3


Original
PDF IEC61000-4-2( DF2S12FU OT-363) SC-88) BEJ0036A 06354C1AE DF2S6.8FS DF6A6.8FU DF2S5.6FS esm 231 DF3A3.3FE SC-81 DF2S16FS DF2S12FU DF2S12FS DF3A8.2FU
2000 - Not Available

Abstract: No abstract text available
Text: per IEC61000-4-2 level 4 QSOP28 SCHEMATIC DIAGRAM Vcc Vcc Rp Rp Rp Rp C C C C 1 2 3 COMPLIES WITH THE FOLLOWING ESD STANDARDS : - IEC61000-4-2 ±15kV (air , protection against ESD. When tested according to IEC61000-4-2 , they withstand ±8kV contact discharges and , 4 of IEC61000-4-2 , without the need for additional ESD protection components. Cells 1 and 2 are , °C) Value Unit ESD discharge IEC61000-4-2 , air discharge ±16 kV ESD discharge IEC61000-4-2


Original
PDF ST1284-xxA8 IEEE1284 IEC61000-4-2 QSOP28
2010 - SPC10501A01

Abstract: iec61000-4-2 IEC-61000-4-2
Text: of High Speed data lines. High ESD Withstand * IEC61000-4-2 8kV Contact Discharge RoHS Directive , Capacitance*1 (pF) 0.1 Max. IEC61000-4-2 8kV Contact Discharge Peak *2 Voltage (V) 500 Max. Clamp *3 , Peak Voltage: *3 Clamp Voltage: Measured at 1MHz, 1V rms. Measured at IEC61000-4-2 8kV Contact Discharge Measured at IEC61000-4-2 8kV Contact Discharge, at 30ns Part Number Description Example SPC , Typical ( IEC61000-4-2 8kV Contact Discharge) 500 400 Capacitance[pF] Voltage[V] 300 200 100 0


Original
PDF HR3TGF10006A01 Jan2010 SPC10 IEC61000-4-2 SPC10 SPC10501A01 IEC-61000-4-2
2012 - Not Available

Abstract: No abstract text available
Text: requirements of IEC61000-4-2 (15KV air, 8KV contact discharge). Feature ■ESD protection for high speed , ) Multilayer Polymer ESD Suppressor IEC61000-4-2 ■Gigabit Ethernet ■USB2.0 and USB3.0 â , Contact discharge voltage Per IEC61000-4-2 - 15KV V Maximum Air discharge voltage Per IEC61000-4-2 - 25KV V Maximum Operating temperature TOPER -40 to +90 ℃ Maximum , VR - - - 12 V Trigger voltage VT IEC61000-4-2 8KV contact discharge


Original
PDF ESDCSA0402V12 ESDCSA0402V12 IEC61000-4-2 Good-Ark2012 000pcs/reel 1-MAY-2012
2011 - SPC10 kamaya

Abstract: IEC61000-4-2 IEC-61000-4-2
Text: IEC61000-4-2 Lv4 8kV Contact Discharge 4. Pb*1, Halogen*2 and Antimony*3 free product *1 Pb 1000ppm *2 Cl , . Note2. Peak voltage : Measured at IEC61000-4-2 8kV Contact Discharge. Note3. Clamp voltage : Measured at IEC61000-4-2 8kV Contact Discharge, at 30ns. Note4. Rated Voltage : The value of voltage that is applicable , solder. Test Methods IEC61000-4-2 8kV, Contact discharge,Peak voltage. IEC61000-4-2 8kV, Contact discharge,After 30ns from the peak voltage. IEC61000-4-2 8kV, Contact discharge,100 pulses After 100 pulses


Original
PDF SPC10 0402inch: IEC61000-4-2 1000ppm 900ppm, 1500ppm 900ppm SPC10 2006Be SPC10 kamaya IEC-61000-4-2
CSA30-141N

Abstract: CSA30-201N surge absorber CSA30-401Q IEC61000-4-2 CSA30-201 CSA30-20 csa30201n IEC-610004-2 IEC-61000-4-2
Text: design, it is easily able to meet the electrostatic protection requirements of IEC61000-4-2. IFeatures IEC61000-4-2 GESD surge absorber in a compact surface mount package GCan be , embossed taping GConforms with IEC61000-4-2 standard Part number system CSA30 - - 201 N , life test DC 50V 10Mmin. DC 100V 1pF max. 150pF-330-25kV 20 times DC 250V IEC61000-4-2 About IEC61000-4-2 150pF-330-28kV 215kV CSA30150pF-330-25kV Electrostatic discharge


Original
PDF CSA30 IEC61000-4-2150pF-330-25kV CSA30 IEC61000-4-2. IEC61000-4-2 CSA30-201N CSA30-401Q CSA30-141N 10Mmin. CSA30-141N CSA30-201N surge absorber CSA30-401Q IEC61000-4-2 CSA30-201 CSA30-20 csa30201n IEC-610004-2 IEC-61000-4-2
2000 - IEEE1284-C

Abstract: IEEE1284-B IEEE-1284-C IEEE1284
Text: control lines and 4 statuts lines In system ESD protection of ±15 kV (air discharge) as per IEC61000-4-2 , . When tested according to IEC61000-4-2 , they withstand ±8kV contact discharges and ±15kV air-discharges, thereby providing to the system the necessary robustness to meet up to level 4 of IEC61000-4-2 , without , figures 1 and 2. COMPLIES WITH THE FOLLOWING ESD STANDARDS : - IEC61000-4-2 ±15kV (air discharge) ± 8kV , 0 to +70 -55 to +150 125 Unit kV kV kV V mW W °C °C °C Parameter ESD discharge IEC61000-4-2 , air


Original
PDF ST1284-xxA8 IEEE1284 IEC61000-4-2 QSOP28 IEEE1284-C IEEE1284-B IEEE-1284-C
2002 - GAL-5

Abstract: QSOP28 IEEE1284-C EMI/RFI filter schematic diagram IEEE1284-B IEEE1284-A IEEE1284 ST1284-xxA8 IEC61000-4-2 ST1284
Text: per IEC61000-4-2 level 4 s SCHEMATIC DIAGRAM s s s s s Vcc 2 3 R1 R1 R2 C 1 Vcc R1 C C C COMPLIES WITH THE FOLLOWING ESD STANDARDS : - IEC61000-4-2 , IEC61000-4-2 , they withstand ±8kV contact discharges and ±15kV air-discharges, thereby providing to the system the necessary robustness to meet up to level 4 of IEC61000-4-2 , without the need for additional , discharge IEC61000-4-2 , air discharge ±16 kV ESD discharge IEC61000-4-2 , contact discharge ±9


Original
PDF ST1284-xxA8 QSOP28 IEEE1284 IEC61000-4-2 GAL-5 QSOP28 IEEE1284-C EMI/RFI filter schematic diagram IEEE1284-B IEEE1284-A ST1284-xxA8 ST1284
2000 - GAL-5

Abstract: IEEE1284-B QSOP-28
Text: control lines and 4 statuts lines In system ESD protection of ±15 kV (air discharge) as per IEC61000-4-2 , 3 COMPLIES WITH THE FOLLOWING ESD STANDARDS : - IEC61000-4-2 ±15kV (air discharge) ± 8kV , . When tested according to IEC61000-4-2 , they withstand ±8kV contact discharges and ±15kV air-discharges, thereby providing to the system the necessary robustness to meet up to level 4 of IEC61000-4-2 , IEC61000-4-2 , air discharge ±16 kV ESD discharge IEC61000-4-2 , contact discharge ±9 kV


Original
PDF ST1284-xxA8 IEEE1284 IEC61000-4-2 QSOP28 GAL-5 IEEE1284-B QSOP-28
2003 - QSOP28

Abstract: IEEE1284 IEEE1284-C QSOP-28 IEEE1284-A IEEE1284-B ST1284
Text: per IEC61000-4-2 level 4 s SCHEMATIC DIAGRAM s s s s s Vcc 2 3 R1 R1 R2 C 1 Vcc R1 C C C COMPLIES WITH THE FOLLOWING ESD STANDARDS : - IEC61000-4-2 , IEC61000-4-2 , they withstand ±8kV contact discharges and ±15kV air-discharges, thereby providing to the system the necessary robustness to meet up to level 4 of IEC61000-4-2 , without the need for additional , discharge IEC61000-4-2 , air discharge ±16 kV ESD discharge IEC61000-4-2 , contact discharge ±9


Original
PDF ST1284-xxA8 QSOP28 IEEE1284 IEC61000-4-2 QSOP28 IEEE1284-C QSOP-28 IEEE1284-A IEEE1284-B ST1284
2014 - Not Available

Abstract: No abstract text available
Text: of the IEC61000-4-2 international standard (Level 4,  ±8kV contact discharge)  without , -4-5, tP=8/20μs) with very low clamping voltages. Features Pinout • ESD, IEC61000-4-2 ,  , VESD CD-GND 0.48 Ω 8.0 IEC61000-4-2 (Contact Discharge) ±30 IEC61000-4-2 (Air , /O-GND Max IPP=1A, tp=8/20µs, Fwd RDYN VESD Typ 0.43 V Ω 5.0 A IEC61000-4-2 (Contact Discharge) ±30 kV IEC61000-4-2 (Air Discharge) ±30 kV Reverse Bias=0V, f


Original
PDF IEC61000-4-2 SPHV12-01ETG-C) IEC61000-4-5, OD882
2014 - Not Available

Abstract: No abstract text available
Text: IEC61000-4-2 international standard (Level 4, ±8kV contact discharge) without performance degradation , ¼s) with very low clamping voltages. Features Pinout • ESD, IEC61000-4-2 , ±30kV contact,  , 0.37 Ω 8.0 A IEC61000-4-2 (Contact Discharge) ±30 kV IEC61000-4-2 (Air Discharge , to GND , Ipp 16.7 tp=8/20µs VESD CI/O-GND V 0.40 Ω 5.0 A IEC61000-4-2 (Contact Discharge) ±30 kV IEC61000-4-2 (Air Discharge) ±30 kV Reverse Bias=0V, f


Original
PDF IEC61000-4-2 SPHV12-01ETG) IEC61000-4-5, OD882
2004 - EMIF02-USB03F2

Abstract: ST MICROELECTRONICS DATE CODE MARKING marking code stmicroelectronics st microelectronics datecode STMicroelectronics marking code date ipad 2 D02u AN1751 STMicroelectronics marking Marking B2
Text: mm High efficiency in ESD suppression ( IEC61000-4-2 level 4) High reliability offered by , . COMPLIES WITH THE FOLLOWING STANDARDS: IEC61000-4-2 Level 4 on external pins 15kV (air discharge) 8kV , test conditions External pins (D1, C1, A2, A3, B3) ESD discharge IEC61000-4-2 , air discharge ESD discharge IEC61000-4-2 , contact discharge Value Unit 15 8 kV 2 2 125 - 40 to + 85 - 55 to + 150 °C °C °C VPP Internal pins (D3, C3, C2, B2, B1) ESD discharge IEC61000-4-2 , air


Original
PDF EMIF02-USB03F2 EMIF02-USB03F2 ST MICROELECTRONICS DATE CODE MARKING marking code stmicroelectronics st microelectronics datecode STMicroelectronics marking code date ipad 2 D02u AN1751 STMicroelectronics marking Marking B2
2009 - MLESD12A-1206A4

Abstract: MDDI EIA-576
Text: speed data lines to IEC61000-4-2 ESD contact discharge typical 8KV, max 15KV IEC61000-4-2 ESD air , - - - 12 V VT IEC61000-4-2 8KV contact discharge - 300 - V Clamping voltage VC IEC61000-4-2 8KV contact discharge - 20 - V Leakage current , - -55 - 150 ESD pulse withstand Pulses IEC61000-4-2 8KV contact discharge , direct discharge method Typical MLESD clamping for +8KV pulse per IEC61000-4-2 Revision: 1


Original
PDF MLESD12A-1206A4 IEC61000-4-2 MLESD12A-1206A4 MDDI EIA-576
2009 - SMF05

Abstract: SMF05T1 SMF05T1G SMF05T2G tvs 88a
Text: Tstg -55 to +150 °C SC-88A (Pb-Free) ESD Discharge IEC61000-4-2 , Air Discharge IEC61000-4-2 , Clamping Voltage (VC) @ IPP (Note 2) 9.5 12 12.5 VC Per IEC61000-4-2 (Note 3) Figures 1 , Positive 8 kV Contact per IEC61000-4-2 Figure 2. ESD Clamping Voltage Screenshot Negative 8 kV Contact per IEC61000-4-2 http://onsemi.com 2 SMF05T1 IEC61000-4-2 Waveform IEC 61000-4-2 Spec , 30 16 8 100% 90% I @ 30 ns I @ 60 ns 10% tP = 0.7 ns to 1 ns Figure 3. IEC61000-4-2


Original
PDF SMF05T1 SC-88A/SOT-323 SMF05T1/D SMF05 SMF05T1 SMF05T1G SMF05T2G tvs 88a
2011 - Not Available

Abstract: No abstract text available
Text: Clamping Voltage Screenshot Positive 8 kV Contact per IEC61000-4-2 Figure 2. ESD Clamping Voltage Screenshot Negative 8 kV Contact per IEC61000-4-2 http://onsemi.com 2 ESD7383 IEC61000-4-2 Spec , at 60 ns (A) 2 4 6 8 I @ 60 ns 10% tP = 0.7 ns to 1 ns I @ 30 ns IEC61000-4-2 Waveform Ipeak 100% 90% Level 1 2 3 4 Figure 3. IEC61000-4-2 Spec ESD Gun TVS Oscilloscope 50 W Cable 50 W , diode during an ESD event per the IEC61000-4-2 waveform. Since the IEC61000-4-2 was written as a pass


Original
PDF ESD7383 ESD7383/D
2012 - HSPC16701B

Abstract: IEC61000-4-2 15KV IEC-61000-4-2
Text: automotive (Tight ESD spec requirement) IEC61000-4-2 Air Discharge: ±15kV Low capacitance 0.1pF Max , 0.5 Ratings ESD Characteristics Part Number Capacitance*1 (pF) 0.2 Max. IEC61000-4-2 15kV Air , . Measured at IEC61000-4-2 15kV Air Discharge Measured at IEC61000-4-2 15kV Air Discharge, at 30ns Part , Typical (1V rms.) 1 ESD Suppression Voltage Waveform Typical ( IEC61000-4-2 15kV Air Discharge) 800


Original
PDF HR3TGF12012A01 Jan2012 HSPC16 IEC61000-4-2 IEEE1394, HSPC16701B 15KV IEC-61000-4-2
2011 - AZD013

Abstract: No abstract text available
Text: ). 2 2 IEC61000-4-2 : ESD Standard for System Level Testing . 3 3 HBM versus IEC61000-4-2 , standard for system level ESD testing. This standard is known as the IEC61000-4-2. While most designers , circuits, the most common misunderstanding occurs between the HBM and IEC61000-4-2 standards. These two , 2 IEC61000-4-2 : ESD Standard for System Level Testing The IEC standard is a system level test


Original
PDF AZD013 IEC61000-4-2: IEC61000-4-2 AZD013
2013 - BZA456A

Abstract: PCMF2DFN1
Text: ESD protection  Greater system-level immunity ( IEC61000-4-2 level 4 standard and beyond) ï , protect the CAN node Selection guide Part Package Size (mm) ESD robustness ( IEC61000-4-2 , Package Size (mm) ESD robustness ( IEC61000-4-2 ) Cd (max) Pppm at tp = 8/20µs VRWM , robustness ( IEC61000-4-2 ) Cd (max) Pppm at tp = 8/20µs VRWM AEC-Q101 PESD1FLEX SOT23 , market. Selection guide Part Package Size (mm) ESD robustness ( IEC61000-4-2 ) Cd (max


Original
PDF
2012 - MIPI csi-2

Abstract: MIPI DSI spec MIPI d-phy spec MIPI csi-2 spec MIPI D-PHY EMI4192 diode MARKING A1 MIPI reference manual HDMI TO MIPI DSI MIPI EMI
Text: Band Attenuation Provides ESD Protection to IEC61000-4-2 Level 4, ±15 kV Contact Discharge Low Channel , ) Parameter Operating Temperature Range Storage Temperature Range ESD Discharge IEC61000-4-2 Contact Discharge , : Contact discharge per IEC61000-4-2 standard TLP Clamping Voltage (See Figure 4) 50 W Source and Load , VRWM VBR V V 1. Standard IEC61000-4-2 with CDischarge = 150 pF, RDischarge = 330, GND grounded. 2 , ESD event. This is illustrated in Figure 4 where an 8 kV IEC61000-4-2 current waveform is compared


Original
PDF EMI4192 WDFN10 EMI4192/D MIPI csi-2 MIPI DSI spec MIPI d-phy spec MIPI csi-2 spec MIPI D-PHY diode MARKING A1 MIPI reference manual HDMI TO MIPI DSI MIPI EMI
Supplyframe Tracking Pixel