The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
J2007001L006Z GE Critical Power IEC-320 SHELF / CONTROLLER
J2007001L006 GE Critical Power IEC-320 SHELF / CONTROLLER
TD1000V3025RMDC GE Critical Power SPD DIN RAIL 1000 PV 25KA IEC
TPD1E05U06DPYT Texas Instruments 1-Channel Ultra-Low-Capacitance IEC ESD Protection Diode 2-X1SON -40 to 125
TPD6E05U06RVZR Texas Instruments 6-Channel Ultra-Low-Capacitance IEC ESD Protection Diodes 14-USON -40 to 125
TPD1E05U06DPYR Texas Instruments 1-Channel Ultra-Low-Capacitance IEC ESD Protection Diode 2-X1SON -40 to 125

IEC 439-1 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2010 - IEC 439-1

Abstract: UMC100-FBP CS31-Bus 3AFE64504215 abb acs800 profibus module CI801 3ADW000191 ABB INSUM mcu ACS550 Single and Dual Input Analyzers ph abb AX400
Text: IP 30 ­ Approvals CE, IEC 439-1 , PTB CE, IEC 439-1 , PTB CE, IEC 439-1 ­ ­ ­ , current information to DCS. -5 . 70 °C IP 30 ­ -5 . 70 °C IP 30 ­ CE, IEC 439-1 CE, IEC 439-1 ­ Yes via INSUM® - Gateway EIA 485 (RS 485) PROFIBUS DP 1.5 Mbit/s fix 067E


Original
PDF 47-EN M00596 M00605 FXE4000 FXM2000 D184S075U02 D184B093U10 D184S007U02 D184B093U05 IEC 439-1 UMC100-FBP CS31-Bus 3AFE64504215 abb acs800 profibus module CI801 3ADW000191 ABB INSUM mcu ACS550 Single and Dual Input Analyzers ph abb AX400
LA9LB920

Abstract: SCHNEIDER MOTOR PROTECTION circuit breaker IEC 439-1 LA9-LB920 GV3-ME40 GK3EF40 GV3-A03 GV3A01 schneider GV2ME GV3-A01
Text: 60947-1 V 690 Conventional rated thermal current (Ith) Conforming to IEC 439-1 A 63 , ) Conforming to IEC 439-1 63 Degree of protection Conforming to IEC 529 Cabling Solid cable , Degree of protection conforming to IEC 529 Basic unit In enclosure GV2-P GV3-ME GV7-R NF , terminal shields ­ Shock resistance to IEC 68-2-27 22 gn - 20 ms 30 gn -11 ms Vibration resistance to IEC 68-2-6 Ambient air temperature Storage °C Operation Open mtd. °C In enclosure °C 5


Original
PDF C22-2 GV2-M/01: LA9-LB920 LA9LB920 SCHNEIDER MOTOR PROTECTION circuit breaker IEC 439-1 LA9-LB920 GV3-ME40 GK3EF40 GV3-A03 GV3A01 schneider GV2ME GV3-A01
2002 - 3TK2842

Abstract: siemens ELCB ia86 IEC 439-1 3tk28 3TK2842-1 3TK2842-2 sensores siemens ELCB 5S pulsador
Text: SIRIUS Sicherheitsschaltgerät 3TK2842 IEC 60 439-1 (1999) Betriebsanleitung Bestell-Nr , berührungslos wirkenden Schutzeinrichtungen nach IEC 61496-1 (06.98), elektrischen Ausrüstungen von , äußerer Beschaltung ist Sicherheitskategorie 4 nach DIN EN 954-1 bzw. SIL 3 nach IEC 61508 zu erreichen , . Verwenden Sie als Stromversorgung ein Netzteil nach IEC 60536 Schutzklasse III (SELV oder PELV)! , < 1 ms Puls (min. 200ms / max. 5s) 5,358x10­11 / 99,35 % 8 h / 10 Jahre nach IEC 60947-5-1


Original
PDF 3TK2842 3ZX1012-0TK28-1DA1 3TK2842 siemens ELCB ia86 IEC 439-1 3tk28 3TK2842-1 3TK2842-2 sensores siemens ELCB 5S pulsador
2002 - 3TK2841

Abstract: IEC 439-1 3ZX1012-0TK28-1JA1 pulsador DC-13 "Y35" siemens led
Text: Sicherheitskombination 3TK2841 IEC 60 439-1 (1999) Betriebsanleitung Warnung: Gefährliche , nach IEC 60536 Schutzklasse III (SELV oder PELV)! Sensoren Eingang Ausgänge Leitungslängen , Verdeckungen und Schutztüren bzw. bei berührungslos wirkenden Schutzeinrichtungen nach IEC 61496-1 (06.98 , . SIL 3 nach IEC 61508 zu erreichen. Klemmen- Betriebsbelegung spannung Deutsch Bestell-Nr , keine Absicherung erforderlich < 1 ms Puls (min. 200ms / max. 5s) Gebrauchskategorie nach IEC


Original
PDF 3TK2841 3ZX1012-0TK28-1JA1 3TK2841 IEC 439-1 3ZX1012-0TK28-1JA1 pulsador DC-13 "Y35" siemens led
2001 - IEC 439-1

Abstract: 3ZX1012-0TK28-4BA1 3tk2840 siemens IEC 60947-5-1 y1112 3TK2840-1 siemens 3tk2840 Y33-Y34 DC-13 en 954-1
Text: Sicherheitsschaltgerät 3TK2840 IEC 60 439-1 (1999) Betriebsanleitung Deutsch , Arbeitsbereich 0,9 . 1,15 x Us Schockfestigkeit Halbsinus nach IEC 60068 8 g/10 ms Gewicht 150 g Wiederbereitschaftszeit bei NOT-AUS Verwenden Sie als Stromversorgung ein Netzteil nach IEC 60536 Schutzklasse III , Beschaltung ist Sicherheitskategorie 3 nach DIN EN 954-1 bzw. SIL2 nach IEC 61508 zu erreichen. Netz , keine Absicherung erforderlich! Gebrauchskategorie nach IEC 60947-5-1 (02.00


Original
PDF 3TK2840 3ZX1012-0TK28-4BA1 IEC 439-1 3ZX1012-0TK28-4BA1 3tk2840 siemens IEC 60947-5-1 y1112 3TK2840-1 siemens 3tk2840 Y33-Y34 DC-13 en 954-1
2002 - 3TK2842

Abstract: siemens IEC 60947-5-1 siemens ELCB 3TK2842-1 3TK2841 3zx1012-0tk28 K163A IEC 439-1 *K2842 3TK2842 english
Text: Sicherheitskombination 3TK2842 IEC 60 439-1 (1999) Betriebsanleitung Bestell-Nr , beweglichen Verdeckungen und Schutztüren bzw. bei berührungslos wirkenden Schutzeinrichtungen nach IEC 61496-1 , DIN EN 954-1 bzw. SIL 3 nach IEC 61508 zu erreichen. Blinkt bei Inbetriebnahme Selbsttest ca. 7 , IEC 60536 Schutzklasse III (SELV oder PELV)! L+ Kanal 1 NOT-AUS bzw. Positionsschalter Kanal 2 , < 1 ms Puls (min. 200ms / max. 5s) nach IEC 60947-5-1 Bemessungsbetriebsspannung


Original
PDF 3TK2842 3ZX1012-0TK28-1DA1 3TK2842 siemens IEC 60947-5-1 siemens ELCB 3TK2842-1 3TK2841 3zx1012-0tk28 K163A IEC 439-1 *K2842 3TK2842 english
2002 - DIN EN 60999-1

Abstract: EN 175 301-801 DIN IEC 600 68-2-2 IEC 439-3 din iec 512 61529 IEC 439-1 IEC 600 68-2-2 iec 60 204-1 VDE 0660 part 500
Text: clearances DIN VDE 0110-1/VDE 0110 part 1: 04.97 ( IEC 60 664-1: 1992, modified) HD 625.1 S1: 1996 ­ Basic principles, requirements and tests DIN EN 60 204 1/VDE 0113 part 1: 11.98 ( IEC 60 204-1: 1992, modified , : 09.00 ( IEC 60 529: 1989, +A: 1999) Protection categories by housing (IP code) DIN VDE 0606: 02.76 and , 0609 part 1: 12.00 ( IEC 60 999: 1999) Connecting devices, safety requirements for screw terminal , part 1: 05.00 ( IEC 60 947-7-1: 1989) Low-voltage switching devices Part 7: Auxiliary equipment Main


Original
PDF 110-1/VDE 0106-100/VDE 0106-101/VDE 011/VDE 255/DIN 89/336/EEC) DIN EN 60999-1 EN 175 301-801 DIN IEC 600 68-2-2 IEC 439-3 din iec 512 61529 IEC 439-1 IEC 600 68-2-2 iec 60 204-1 VDE 0660 part 500
IEC 60249-2-4

Abstract: IEC 439-1 iso 7811-4 4303S 4304S M3583 4306S 4323S
Text: Flame retardancy complying with UL 94: V-0 V-0 complying with IEC 60 707: BH 2-30 Number of , enable high tightening torques high-voltage test complying with IEC 60 439-1 Printed circuit board , ,0 mm IEC 60 664-1 IEC 60 664-1 IEC 60 664-1 IEC 60 664-1 IP 40 IEC 60 529 IP 20 IEC 60 , : Other options: )LWWHG SULQWHG FLUFXLW ERDUG IEC /EN 60 715 More information see brochure G23 , thickness = 1,5): - soldering side max. 0,5 - component side max. 14,1 1) Tolerance to IEC 60249-2-4


Original
PDF 4300S 4303S 4304S 4305S 4303S; 4304S; 4305S: 4323S; 4324S; 4325S: IEC 60249-2-4 IEC 439-1 iso 7811-4 4303S 4304S M3583 4306S 4323S
IEC 60249-2

Abstract: IEC 439-1 IEC 60249-2-4 4304S DIN 228-1
Text: with IEC 60 439-1 Printed circuit board density t = 1,5 mm and 1 mm possible More option possible , Flame retardancy complying with UL 94: V-0 V-0 complying with IEC 60 707: BH 2-30 Number of , protection Enclosure: Terminal strip: IEC /EN 60 715 CTI 175 = insulating material III a CTI 250 - 400 = insulating material III a outside: 6,3 mm inside: 4,0 mm IEC 60 664-1 IEC 60 664-1 IEC 60 664-1 IEC 60 664-1 IP 40 IEC 60 529 IP 20 IEC 60 529 contact protection complies with VBG


Original
PDF 4300S 4303S 4304S 4305S 4306S D-78114 IEC 60249-2 IEC 439-1 IEC 60249-2-4 4304S DIN 228-1
PT100 temperature sensor

Abstract: PT100 temperature sensor JUMO sensor PT100 PT100 JUMO water level SENSOR WITH PT100 temperature sensor pt100 PT100 surface temperature sensor pt100 temperature IEC 439-1 PT100 temperature sensor data sheet
Text: ) Technical data Reference conditions to DIN 16 086 and IEC 770/5.3 Ranges see Order details Overload


Original
PDF 1-800-554-JUMO PT100 temperature sensor PT100 temperature sensor JUMO sensor PT100 PT100 JUMO water level SENSOR WITH PT100 temperature sensor pt100 PT100 surface temperature sensor pt100 temperature IEC 439-1 PT100 temperature sensor data sheet
AC500 plc

Abstract: 07KT97 codesys 2.3 Manual PM581 abb PM571 PM571 error code AI523 AX522 PDR11-FBP TA521
Text: an external project database from the programming system) IEC operators and additional , internal CPU firmware. Short description of the software Programming in conformity with IEC 61131-3 , : Single step, Single cycle, Breakpoint Offline simulation IEC 61131-3 commands can be simulated


Original
PDF AC500 AC500/S500-FBP AC500 DC505-FBP) DC505-FBP QB124 M0201 AC500 plc 07KT97 codesys 2.3 Manual PM581 abb PM571 PM571 error code AI523 AX522 PDR11-FBP TA521
Not Available

Abstract: No abstract text available
Text: - °A = B 00" * 1B la - B 7 < " B6 " A6 CD CA *5 2 2 3 3 - 6 7 IEEE/ IEC b


OCR Scan
PDF 54F/74F521 20-pin TL/F/9545-7
1-800-LAMBDA-4

Abstract: 500LFM 7G0011A A 8152
Text: must be reinforced or double insulated to the AC input in accordance with IEC /EN 60950-1 to achieve


Original
PDF PXE30 1-800-LAMBDA-4 1-800-LAMBDA-4 500LFM 7G0011A A 8152
R1202

Abstract: L0939 IEC 60947-5-1 limit switch 5252 F 1104 L1237 M74 marking 5252 f 1101 LS32M13B11 LS32M41B11 entrelec diode
Text: captive cable clamp) Markings conform with IEC 60947-1, IEC 60947-5-1, EN 50005 and EN 50013 standards , terminals: M3.5 (+,­) pozidriv 2 screw (Screw head with captive cable clamp) Markings conform with IEC 60947-1, IEC 60947-5-1, EN 50005 and EN 50013 standards B 1 1 P Limit Switch , General Technical Data Plastic Casing Metal Casing IEC 60947-1, IEC 60947-5-1, EN 60947-1, EN , Shock withstand (according to IEC 68-2-27 and EN 60068-2-27) g Resistance to vibrations (acc. to IEC


Original
PDF LS32M. LS33M. LS35M. LS72M. LS73M. LS75M. LS72P. LS73P. LS75P. R1320 R1202 L0939 IEC 60947-5-1 limit switch 5252 F 1104 L1237 M74 marking 5252 f 1101 LS32M13B11 LS32M41B11 entrelec diode
1-800-LAMBDA-4

Abstract: 500LFM
Text: must be reinforced or double insulated to the AC input in accordance with IEC /EN 60950-1 to achieve


Original
PDF PXF40 1-800-LAMBDA-4 1-800-LAMBDA-4 500LFM
2010 - Not Available

Abstract: No abstract text available
Text: accordance with the Absolute Maximum Rating System ( IEC 60134). Conditions Tj 25 °C; Tj 175 °C RGS = 20 k , 2.54 Lp 2.90 2.10 HD 15.80 14.80 Q 2.60 2.20 OUTLINE VERSION SOT404 REFERENCES IEC JEDEC JEITA , defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the device


Original
PDF BUK763R6-40C
2010 - BUK763R6-40C

Abstract: No abstract text available
Text: . Limiting values Table 4. Limiting values In accordance with the Absolute Maximum Rating System ( IEC , OUTLINE VERSION REFERENCES IEC JEDEC JEITA EUROPEAN PROJECTION ISSUE DATE 05-02-11 , Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134


Original
PDF BUK763R6-40C BUK763R6-40C
2010 - Not Available

Abstract: No abstract text available
Text: with the Absolute Maximum Rating System ( IEC 60134). Symbol Parameter Conditions Min Max , . Dimension includes excess dambar. OUTLINE VERSION SOT78 REFERENCES IEC JEDEC JEITA 3-lead TO , Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134


Original
PDF BUK754R0-40C
2003 - wiring diagram dol motor starter

Abstract: star delta starter single line drawing star delta wiring diagram motor start y dol motor starter wiring diagram Bradley smc-3 dol starter WAGO 281 C60N 140M-D8N-C10 BUSBAR calculation datasheet
Text: capability to design electrical control systems according to either IEC or UL/CSA requirements including: · , · IEC coordination types and UL/CSA starter approvals · Metric or Imperial Measurement Units · Report formats to assemble the entire bill of material into a structured order format · View/print IEC , future changes / enhancements / upgrades. · The starters are designed for the world market with IEC , -CMN · IEC 60 439-1 dispenses from verification for Ipk < 17 kA. 140M and 140-CMN limit s-c currents


Original
PDF A114-CA001A 150-SG006A D-74834 41A-SG001B-EN-P wiring diagram dol motor starter star delta starter single line drawing star delta wiring diagram motor start y dol motor starter wiring diagram Bradley smc-3 dol starter WAGO 281 C60N 140M-D8N-C10 BUSBAR calculation datasheet
2007 - Socomec ISOM DLD 3204

Abstract: iec 62053-21 CE 44 remote code IEC 439-1 Socomec DLD 3065 socomec IEC 60947-3 socomec changeover switch limit switch VDE 0660 t60 DIRIS A20 SCV200U ATDR10
Text: . 69 -70 C SIRCOVER Manually operated changeover switches from 125 to 3150 A - IEC 947-3 · , changeover switches from 125 to 1600 A - IEC 947-3 · Product presentation . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . · IEC 947-1 & IEC 947-3 standards , A complete range of IEC products . . . . . . . . . . p. 124 LBS from 16 to 125 A , are integral to the switch body and recessed to insure a "finger safe" environment according to IEC


Original
PDF UL508/CSA UL98/CSA BR-SOC-001 Socomec ISOM DLD 3204 iec 62053-21 CE 44 remote code IEC 439-1 Socomec DLD 3065 socomec IEC 60947-3 socomec changeover switch limit switch VDE 0660 t60 DIRIS A20 SCV200U ATDR10
2010 - Not Available

Abstract: No abstract text available
Text: . Limiting values In accordance with the Absolute Maximum Rating System ( IEC 60134). Symbol Parameter , 2.10 15.80 14.80 2.60 2.20 OUTLINE VERSION REFERENCES IEC JEDEC JEITA EUROPEAN , or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause


Original
PDF BUK763R6-40C
2010 - Not Available

Abstract: No abstract text available
Text: Rating System ( IEC 60134). Symbol Parameter Conditions Min Max Unit VDS , excess dambar. OUTLINE VERSION SOT78 REFERENCES IEC JEDEC JEITA 3-lead TO-220AB SC , of IEC 60134) will cause permanent damage to the device. Limiting values are stress ratings only and


Original
PDF BUK754R0-40C
fuse f5A 250V

Abstract: 1-800-LAMBDA-4 500LFM IEC 439-1
Text: to this product must be reinforced or double insulated to the AC input in accordance with IEC /EN


Original
PDF PXD20 1-800-LAMBDA-4 fuse f5A 250V 1-800-LAMBDA-4 500LFM IEC 439-1
2013 - ACRICH DT3001B

Abstract: DT3001B LED 5630
Text: protection specification. Combination Wave IEC 6100-4-5 Line to Line Rise time Duration Open , . Combination wave, Open Surge Voltage ( IEC 61000-4-5) Copyright ⓒ Seoul Semiconductor Co., Ltd


Original
PDF 50kHz) ACRICH DT3001B DT3001B LED 5630
2004 - PLC PS4-341-MM1

Abstract: york chillers PS4-341-MM1 MOELLER PS4-201-MM1 Moeller IZM 32 wiring diagram DOL starter PLC old york chillers ps4-341-mm1 danfoss compressor JS84E
Text: used worldwide. This applies both to the IEC and to the CSA/UL world. Motor starters also include , IEC 60439. The system module, available in versions from Form 1 to Form 4, is designed to meet the , : Switching and protective devices: IEC /EN 60 439-1 Type-tested system modules 690V / 50 - 60Hz bis 4000 , web servers, as well as CANopen for communication. Programming in compliance with IEC 61131-3 also , also implemented using the SymARTI interface with the widely used IEC 61131-3-compliant programming


Original
PDF D-53115 PLC PS4-341-MM1 york chillers PS4-341-MM1 MOELLER PS4-201-MM1 Moeller IZM 32 wiring diagram DOL starter PLC old york chillers ps4-341-mm1 danfoss compressor JS84E
Supplyframe Tracking Pixel