The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
PCJ-103D3M,301 (1721081-1) TE Connectivity (1721081-1) PCJ-103D3M,301
PCJ-103D3MH,301 (1721081-8) TE Connectivity (1721081-8) PCJ-103D3MH,301
PCJ-109D3M,301 (1721081-4) TE Connectivity (1721081-4) PCJ-109D3M,301
PCJ-118D3M,301 (1721081-6) TE Connectivity (1721081-6) PCJ-118D3M,301
PCJ-106D3M,301 (1721081-3) TE Connectivity (1721081-3) PCJ-106D3M,301
PCJ-124D3M,301 (1721081-7) TE Connectivity (1721081-7) PCJ-124D3M,301
SF Impression Pixel

Search Stock (3)

  You can filter table by choosing multiple options from dropdownShowing 3 results of 3
Part Manufacturer Supplier Stock Best Price Price Each Buy Part
G9SA-301-P DC24 OMRON Corporation Avnet - $281.09 $227.29
G9SA-301-P DC24 OMRON Industrial Automation Heilind Electronics - - -
G9SA-301-PDC24 OMRON Industrial Automation Sager - $260.34 $235.54

No Results Found

G9SA-301-P Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
G9SA-301

Abstract: G9SA-321-T30 G9SA-321-T075 G9SA-321-T15 G9SA-501 G9SA-EX031-T15 T075 ex03 G9SA-321 G9SA-EX031-T075
Text: possible ibl 24 VAC/VDC 4 G9SA- 301 5PST-NO SPST-NC 1 channel or 2 channels possible , J EXPANSION UNIT The Expansion Unit connects to a G9SA- 301 , G9SA-501, or G9SA-321. Main contacts , EXPANSION UNITS WITH OFF-DELAY OUTPUTS The Expansion Unit connects to a G9SA- 301 , G9SA-501, or G9SA , 3: 3PST-NO 5: 5PST-NO 5. Input Configuration (for G9SA- 301 /501/321) None: 1-channel or 2 , G9SA- 301 /501/321-Tj/EX301/EX031-Tj Resistive load (cos =1) Rated load 250 VAC, 5 A Rated


Original
PDF 45-mm 15-step G9SA-30 G9SA-321-Tj G9SA-EX301 G9SA-EX031-TV G9SA-EX031-Tj G9SA-EX031-Tj G9SA-301 G9SA-321-T30 G9SA-321-T075 G9SA-321-T15 G9SA-501 G9SA-EX031-T15 T075 ex03 G9SA-321 G9SA-EX031-T075
magnetic Contactor wiring diagrams

Abstract: omron G9SA-301 nc OMRON Operation Manual G9SA-501 G9SA-321-T30 G9SA-321-T15 G9SA-321-T075 G9SA-321 G9SA-301 T075
Text: G9SA- 301 4 100 to 240 VAC 5PST-NO 24 VAC/VDC G9SA-501 100 to 240 VAC Emergency-stop , Controllers 100 to 240 VAC Expansion Unit The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA , connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main contact form 3PST-NO Auxiliary contact , (for G9SA- 301 /501/321) None: 1-channel or 2-channel input possible 6. OFF-delay Time (Max. setting , G9SA- 301 /TH301 G9SA-501 Power supply voltage Operating voltage range 85% to 110% of rated


Original
PDF 45-mm 15-step magnetic Contactor wiring diagrams omron G9SA-301 nc OMRON Operation Manual G9SA-501 G9SA-321-T30 G9SA-321-T15 G9SA-321-T075 G9SA-321 G9SA-301 T075
magnetic Contactor

Abstract: magnetic Contactor wiring diagrams G9SA-TH301 EX03 G9SA-301 omron G9SA-301 G9SA-321-T30 G9SA-501 A165E G9SA-321-T15
Text: -NO SPST-NC 1 channel or 2 channels possible ibl 24 VAC/VDC Model G9SA- 301 Category 4 100 , G9SA-TH301 Category 4 100 to 240 VAC Expansion Unit The Expansion Unit connects to a G9SA- 301 , connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main contact form Auxiliary contact 3PST , : None 1: SPST-NC 5. Input Configuration (for G9SA- 301 /501/321) None: 1-channel or 2 , G9SA Specifications Ratings Power Input Item G9SA- 301 /TH301 G9SA-501 G9SA-321-Tj 24


Original
PDF 45-mm 15-step G9SA-TH301 J121-E1-2 75-344-7119/Fax: 0900-1M magnetic Contactor magnetic Contactor wiring diagrams EX03 G9SA-301 omron G9SA-301 G9SA-321-T30 G9SA-501 A165E G9SA-321-T15
2011 - magnetic Contactor

Abstract: G9SA-321 ISO13849-2 G9SA-301
Text: to 240 VAC Model G9SA- 301 G9SA-501 Emergency-stop OFF-delay Units Main contacts OFF-delay , 240 VAC Model G9SA-TH301 Expansion Unit The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA , with OFF-delay Outputs The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301 , G9SA-EX031-T15 G9SA-EX031-T30 2 G9SA Specifications Ratings Power Input Item Model G9SA- 301 /TH301 , connected, the power consumption is increased by 2 VA/2 W max. Inputs Item Input current * Model G9SA- 301


Original
PDF 45-mm 15-step ISO13849-1 magnetic Contactor G9SA-321 ISO13849-2 G9SA-301
F3S-TGR-NLPC-20-05

Abstract: F3S-TGR-NLPC-20-M1J8 OMRON F3S-TGR-NMPC-20-05 F3S-TGR-NLPC-21-02 F3S-TGR-NSMC-21-02 F3S-TGR-NLPC-21-05 F3S-TGR-NSMC-21-05 omron optocoupler F3S-TGR-NMPC-20-10 F3S-TGR-NSMC-20-M1J8
Text: NLPC and NSMC Miniature Sensor 2. Housing Material P : Plastic Housing M: Stainless Steel , 2008 10:56 10 Accessories G9SA G9SA- 301 G9SA-501 G9SA-321-T075 G9SA-321-T15 G9SA-321-T30 G9SB G9SB-2002-C G9SB-2002-A G9SB-200-B G9SB-200-D G9SB-3012-A G9SB- 301 -B G9SB-3012-C G9SB- 301 , Single Sensor Application with G9SA- 301 (up to Safety Category 4 acc. EN954-1) +24V GND Start , brown orange KM1 Feedbackloop G9SA- 301 T11 T12 T22 T21 KM2 T32 NO contact KM1


Original
PDF E14E-EN-02 EN60947-5-3. E14E-EN-02 F3S-TGR-NLPC-20-05 F3S-TGR-NLPC-20-M1J8 OMRON F3S-TGR-NMPC-20-05 F3S-TGR-NLPC-21-02 F3S-TGR-NSMC-21-02 F3S-TGR-NLPC-21-05 F3S-TGR-NSMC-21-05 omron optocoupler F3S-TGR-NMPC-20-10 F3S-TGR-NSMC-20-M1J8
magnetic Contactor wiring diagrams

Abstract: magnetic Contactor magnetic Contactor 24VDC G9SA-301 G9SA-321-T30 omron G9SA-301 T075 G9SA-501 G9SA-321-T15 G9SA-321-T075
Text: VAC/VDC 100 to 240 VAC 24 VAC/VDC 100 to 240 VAC Model Category G9SA- 301 4 G9SA , 4 (IIIc, EN574) 321, or G9SA-TH301. The Expansion Unit connects to a G9SA- 301 , G9SA , Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main contact form Auxiliary , (for G9SA- 301 /501/321) None: 1-channel or 2-channel input possible 6. OFF-delay Time (Max. setting , .) G9SA- 301 /TH301 G9SA-501 24 VAC/VDC:24 VAC, 50/60 Hz, or 24 VDC 100 to 240 VAC:100 to 240 VAC, 50/60


Original
PDF F502-EN2-04 45-mm 15-step G9SA-501, G9SA321# G9SA-TH301) G-121 J121-E2-03A-X G-122 magnetic Contactor wiring diagrams magnetic Contactor magnetic Contactor 24VDC G9SA-301 G9SA-321-T30 omron G9SA-301 T075 G9SA-501 G9SA-321-T15 G9SA-321-T075
2011 - G9SA-301 performance level

Abstract: G9SA-301 OMRON G9SA-321-T075 EX03 ISO13849-2 omron G9SA-301 g9sa magnetic contactor EN6094 1NC1
Text: to 240 VAC Model G9SA- 301 G9SA-501 Emergency-stop OFF-delay Units Main contacts OFF-delay , 240 VAC Model G9SA-TH301 Expansion Unit The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA , with OFF-delay Outputs The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301 , G9SA-EX031-T15 G9SA-EX031-T30 2 G9SA Specifications Ratings Power Input Item Model G9SA- 301 /TH301 , connected, the power consumption is increased by 2 VA/2 W max. Inputs Item Input current * Model G9SA- 301


Original
PDF 45-mm 15-step ISO13849-1 G9SA-301 performance level G9SA-301 OMRON G9SA-321-T075 EX03 ISO13849-2 omron G9SA-301 g9sa magnetic contactor EN6094 1NC1
magnetic Contactor wiring diagrams

Abstract: magnetic Contactor magnetic Contactor 24VDC G9SA-321-T30 G9SA-EX031-T G9SA-301 T075 EN574 omron G9SA-301 G9SA-321-T075
Text: G9SA- 301 4 G9SA-501 Emergency-stop OFF-delay Units Main contacts OFF-delay contacts , Category G9SA-TH301 4 (IIIc, EN574) Expansion Unit The Expansion Unit connects to a G9SA- 301 , Outputs The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main contact form , Configuration (for G9SA- 301 /501/321) None: 1-channel or 2-channel input possible 6. OFF-delay Time (Max , (See note.) G9SA- 301 /TH301 G9SA-501 24 VAC/VDC:24 VAC, 50/60 Hz, or 24 VDC 100 to 240 VAC:100 to


Original
PDF 45-mm 15-step G9SA-301, G9SA-501, G9SA321# G9SA-TH301) magnetic Contactor wiring diagrams magnetic Contactor magnetic Contactor 24VDC G9SA-321-T30 G9SA-EX031-T G9SA-301 T075 EN574 omron G9SA-301 G9SA-321-T075
G9SA-321-T30

Abstract: G9SA-301 MA-16DP11C3 G9SA-321 MA-13DP11C3 G9SA-EX031-T075
Text: G9SA-EX301 G9SA-321 G9SA-501 RoHS INTERCONNECT G9SA- 301 G9SA-EX031 G9SA- 301 Dual-Channel Power Requirements: The G9SA- 301 will accept 24 VAC/VDC or 100 to 230 VAC. Inputs: The G9SA- 301 will accept single or dual NC inputs or dual inputs from a light curtain (see G9SA- 301 for application wiring for a light curtain). Outputs: The G9SA- 301 has 3 NO outputs to route power to the coils of power contacts, plus 1 NC , between T31 and T32 on the G9SA301. Reset Mode: Automatic or manual reset modes are available on the G9SA- 301


Original
PDF G9SA-EX301 G9SA-321 G9SA-501 G9SA-301 G9SA-EX031 G9SA-301 G9SA-321-T30 MA-16DP11C3 MA-13DP11C3 G9SA-EX031-T075
EN 60947-5-1 OMRON

Abstract: G9SA-TH301 G9SA-301 omron G9SA-301 KM26 OMRON G9SA-321-T075 th301 EN574 G9SA-501 EN954
Text: Eingangskanäle 1 Kanal oder 2 Kanäle möglich Nennspannung Modell Kategorie 4 G9SA- 301 24 VAC/VDC , Erweiterungsmodul Das Erweiterungsmodul ist an ein G9SA- 301 , G9SA-501, G9SA-321 oder G9SA-TH301 angeschlossen , Erweiterungsmodul mit Ausschaltverzögerungsausgängen Das Erweiterungsmodul ist an ein G9SA- 301 , G9SA-501, G9SA , : 3 Schließer Spezifikationen Nenndaten Leistungseingang Angabe G9SA- 301 /TH301 G9SA , Eingangsstrom (siehe Hinweis.) Hinweis: G9SA-501 G9SA- 301 /321-Tj/TH301 max. 40 mA max. 60 mA Wenn


Original
PDF EN954 G9SA-501, G9SA-321j G9SA-TH301) EN 60947-5-1 OMRON G9SA-TH301 G9SA-301 omron G9SA-301 KM26 OMRON G9SA-321-T075 th301 EN574 G9SA-501
2009 - G9SA-301

Abstract: relay 24vac omron EX031 t12t2 T075 G9SA-501 G9SA-321-T30 G9SA-321-T15 G9SA-321-T075 G9SA-321
Text: Model G9SA- 301 G9SA-501 Emergency-stop OFF-delay Units Main contacts OFF-delay contacts , G9SA-TH301 Expansion Unit The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301 , OFF-delay Outputs The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main , Power Input Item Model G9SA- 301 /TH301 G9SA-501 Power supply voltage Operating voltage , consumption is increased by 2 VA/2 W max. Inputs Item Model G9SA- 301 /321-T@/TH301 G9SA-501 40


Original
PDF 45-mm 15-step G9SA-301 relay 24vac omron EX031 t12t2 T075 G9SA-501 G9SA-321-T30 G9SA-321-T15 G9SA-321-T075 G9SA-321
2009 - G9SA-321-T30

Abstract: G9SA-301 OMRON G9SA-321-T075 G9SA-501 omron g9sa-301 magnetic Contactor G9SA-321-T15 EN574 G9SA-321-T075 T075
Text: Model G9SA- 301 G9SA-501 Emergency-stop OFF-delay Units Main contacts OFF-delay contacts , G9SA-TH301 Expansion Unit The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301 , OFF-delay Outputs The Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main , Power Input Item Model G9SA- 301 /TH301 G9SA-501 Power supply voltage Operating voltage , consumption is increased by 2 VA/2 W max. Inputs Item Model G9SA- 301 /321-T@/TH301 G9SA-501 40


Original
PDF 45-mm 15-step G9SA-321-T30 G9SA-301 OMRON G9SA-321-T075 G9SA-501 omron g9sa-301 magnetic Contactor G9SA-321-T15 EN574 G9SA-321-T075 T075
magnetic Contactor wiring diagrams

Abstract: magnetic Contactor EN574 G9SA-301 lc1d contactor G9SA-501 G9SA-321-T30 G9SA-321-T15 G9SA-321-T075 VAC K4
Text: 5PST-NO Rated voltage Model 24 VAC/VDC 4 G9SA- 301 24 VAC/VDC Category G9SA , G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main contacts 3PST-NO Auxiliary contact SPST-NC , Expansion Unit connects to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main contact form Auxiliary , Item G9SA- 301 /TH301 G9SA-501 G9SA-321-Tj 24 VAC/VDC: 2.8 VA/2.6 W max. 24 VAC/VDC: 3.5 , 2 VA/2 W max. Inputs Item G9SA- 301 /321-Tj/TH301 Input current (See note.) Note: G9SA


Original
PDF 45-mm 15-step G9SA-301, G9SA-501, G9SA-321j, G9SA-TH301) J121-E1-1 6-6949-6025/Fax: 0200-2M magnetic Contactor wiring diagrams magnetic Contactor EN574 G9SA-301 lc1d contactor G9SA-501 G9SA-321-T30 G9SA-321-T15 G9SA-321-T075 VAC K4
2007 - G9SA-EX-031

Abstract: JIS A 5354
Text: Number of input channels Rated voltage 24 VAC/VDC 100 to 240 VAC 24 VAC/VDC 100 to 240 VAC Model G9SA- 301 , to a G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main contacts 3PST-NO Auxiliary contact SPST-NC Model G9SA-EX301 Expansion Units with OFF-delay Outputs The Expansion Unit connects to a G9SA- 301 , Reserved. 2 G9SA Specifications Ratings Power Input Item Model G9SA- 301 /TH301 G9SA-501 24 VAC , power consumption is increased by 2 VA/2 W max. Inputs Item Input current * Model G9SA- 301 /321


Original
PDF 45-mm 15-step G9SA-EX-031 JIS A 5354
F39-TGR-CVL-B-10-R

Abstract: F39-TGR-SB4-CVLB F3S-TGR-NSMR-21-05 F39-TGR-NT OMRON G9SA-321-T075 F3S-TGR-NMPR-21-02 F3S-TGR-NMPR-20-02 F3S-TGR-NLPR-21-05 NE1A-SCPU01L F39-TGR-CVL-B-2-R
Text: Miniature Sensor RS 549-580 RS 549-586 RS 549-621 2. Housing Material P : Plastic Housing M , . Please contact your Omron distributor 2 Safety Sensors / Components Accessories G9SA G9SA- 301 , -200-B G9SB-200-D G9SB-3012-A G9SB- 301 -B G9SB-3012-C G9SB- 301 -D G9SX G9SX-BC202-R_ G9SX-AD322-T15-R , examples (Single head connection up to category 4 acc. EN954-1) G9SA Single Sensor Application with G9SA- 301 , indication (option) F3S-TGR-NxxR Sensor A1 GND Start A2 T31 KM1 Feedbackloop G9SA- 301


Original
PDF EN60947-5-3 E18E-EN-02 F39-TGR-CVL-B-10-R F39-TGR-SB4-CVLB F3S-TGR-NSMR-21-05 F39-TGR-NT OMRON G9SA-321-T075 F3S-TGR-NMPR-21-02 F3S-TGR-NMPR-20-02 F3S-TGR-NLPR-21-05 NE1A-SCPU01L F39-TGR-CVL-B-2-R
F39-TGR-NT

Abstract: F39-TGR-CVL-B-10-R OMRON G9SA-321-T075 F39-TGR-SB4-CVLB F3S-TGR-NMPR-21-02 F39-TGR-CVL-N-10 F3S-TGR-NMPR-20-02 F39-TGR-CVL-B-5-R F3S-TGR-NSMR-20-05 F3S-TGR-NLPR-20-10
Text: Miniature Sensor 2. Housing Material P : Plastic Housing M: Stainless Steel Housing 3: Contact , Safety Sensors / Components Accessories G9SA G9SA- 301 G9SA-501 G9SA-321-T075 G9SA-321-T15 G9SA-321-T30 G9SB G9SB-2002-C G9SB-2002-A G9SB-200-B G9SB-200-D G9SB-3012-A G9SB- 301 -B G9SB-3012-C G9SB- 301 -D G9SX G9SX-BC202-R_ G9SX-AD322-T15-R_ G9SX-AD322-T150-R_ G9SX-ADA222-T15-R , acc. EN954-1) G9SA Single Sensor Application with G9SA- 301 (up to Safety Category 4 acc. EN954


Original
PDF EN60947-5-3 E18E-EN-02 F39-TGR-NT F39-TGR-CVL-B-10-R OMRON G9SA-321-T075 F39-TGR-SB4-CVLB F3S-TGR-NMPR-21-02 F39-TGR-CVL-N-10 F3S-TGR-NMPR-20-02 F39-TGR-CVL-B-5-R F3S-TGR-NSMR-20-05 F3S-TGR-NLPR-20-10
2007 - RELAY OMRON G9 SA

Abstract: RELAY OMRON G8 RELAY OMRON G6 diode T31 Marking PLC control automatic welding machine ca10 reverse switch ca3 contactor max RS485 dc welding machine circuit diagram
Text: 100 to 240 VAC G9SA-501 Model G9SA- 301 4 Category Emergency-stop OFF-delay Units Main contacts , G9SA- 301 , G9SA-501, G9SA-321, or G9SA-TH301. Main contacts 3PST-NO Auxiliary contact SPST-NC G9SA-EX301 , . 1 G9SA Expansion Units with OFF-delay Outputs The Expansion Unit connects to a G9SA- 301 , G9SA , : 3PST-NO 4. Contact Configuration (Auxiliary Output) 0: None 1: SPST-NC 5. Input Configuration (for G9SA- 301 , Power supply voltage Operating voltage range Power consumption (See note.) G9SA- 301 /TH301 24 VAC/VDC:24


Original
PDF 45-mm 15-step J121-E1-06 RELAY OMRON G9 SA RELAY OMRON G8 RELAY OMRON G6 diode T31 Marking PLC control automatic welding machine ca10 reverse switch ca3 contactor max RS485 dc welding machine circuit diagram
circuit diagram of door lock system

Abstract: emergency stop relay y1 y2 circuit diagram of door interlock system T32 fuse G9SA-501 g9sx-BC202 G9SA-301 two door controller circuit diagrams dc welding machine circuit diagram magnetic contactors
Text: A22E/A165E G9SA- 301 /G9SA-501, S82K 76 2 Emergency Stop Switches (Set of two) 2 4 0 A22E/A165E G9SA- 301 /G9SA-501, S82K 77 3 Safety Limit Switches (Set of two) 2 4 0 D4B-N/D4N/D4F G9SA- 301 /G9SA-501, S82K 78 4 Safety Door Switches 2 4 0 D4GS-N/D4NS/D4BS G9SA- 301 /G9SA-501, S82K 79 5 Safety Door Switches (Set of two) 2 3 0 D4GS-N/D4NS/D4BS G9SA- 301 /G9SA-501, S82K 80 6 Safety Door Switches (Set of two) 1 2 0


Original
PDF A22E/A165E G9SA-301/G9SA-501, G9SA-30sor circuit diagram of door lock system emergency stop relay y1 y2 circuit diagram of door interlock system T32 fuse G9SA-501 g9sx-BC202 G9SA-301 two door controller circuit diagrams dc welding machine circuit diagram magnetic contactors
F3S-TGR-NLPC-21-05

Abstract: F3S-TGR-NLPC-20-05 F39-TGR-SB4-CVLB5R F3S-TGR-NSMC-21-05 F3S-TGR-NLPC-21-02 F39-TGR-SB4-CVLB10R magnetic head wiring 7 pin G9SX-ADA222-T150-RT F39-TGR-SB4-CVLB T3114
Text: 2. Housing Material P : Plastic Housing M: Stainless Steel Housing 3: Contact configuration 20 , G9SA- 301 G9SA-501 G9SA-321-T075 G9SA-321-T15 G9SA-321-T30 G9SB G9SB-2002-C G9SB-2002-A G9SB-200-B G9SB-200-D G9SB-3012-A G9SB- 301 -B G9SB-3012-C G9SB- 301 -D G9SX G9SX-BC202-RC G9SX-BC202-RT , . EN954-1) G9SA Single Sensor Application with G9SA- 301 (up to Safety Category 4 acc. EN954-1) +24V , yellow green brown orange KM1 Feedbackloop G9SA- 301 T11 T12 T22 T21 KM2 T32 NO


Original
PDF E14E-EN-01A EN60947-5-3. E14E-EN-01A F3S-TGR-NLPC-21-05 F3S-TGR-NLPC-20-05 F39-TGR-SB4-CVLB5R F3S-TGR-NSMC-21-05 F3S-TGR-NLPC-21-02 F39-TGR-SB4-CVLB10R magnetic head wiring 7 pin G9SX-ADA222-T150-RT F39-TGR-SB4-CVLB T3114
2008 - F39-JC7C

Abstract: F39-JC1C omron 24V 5A RELAY F39-JC F39-JC15C F39-JC7 3M Touch Systems G9SA300-SC F39-JC3 F39-JC3C
Text: ,000 operations min. (at approx. 1,800 operations/h, rated load) Failure rate ( P level) (reference


Original
PDF G9SA-300-SC G9SA-300-SC F39-JC7C F39-JC1C omron 24V 5A RELAY F39-JC F39-JC15C F39-JC7 3M Touch Systems G9SA300-SC F39-JC3 F39-JC3C
2008 - omron G9SA-301

Abstract: F3SS-AT60P-D magnetic contactors IEC61496-1 F39-LLK
Text: : DC-driven high-sensitivity contactors (e.g., J7AN) 3 F3SS Connection with OMRON G9SA- 301 Safety , M Note: When connecting the F3SS to the G9SA- 301 , disable the F3SS's start/restart interlock function and use the interlock function in the G9SA- 301 instead. Refer to the Instruction Manual


Original
PDF IEC61496-1, omron G9SA-301 F3SS-AT60P-D magnetic contactors IEC61496-1 F39-LLK
J7KNA-AR-31

Abstract: J7KNA-AR-40 omron contactor J7KNA-AR-22 CONTACTOR EN 60947-4-1 EN60947-5-1 J7KNA-AR VDE 0660 EN60947-5-1 VDE 0660 - 107 J73KN-A-40
Text: G9SA- 301 (24-V AC/DC) (two limit switch input channels with manual reset) Feedback Circuit


Original
PDF AC-15, DC-13) J7KNA-AR-31 J7KNA-AR-40 omron contactor J7KNA-AR-22 CONTACTOR EN 60947-4-1 EN60947-5-1 J7KNA-AR VDE 0660 EN60947-5-1 VDE 0660 - 107 J73KN-A-40
2007 - relay 24v omron

Abstract: hot air gun fan controller circuit carbon brush motor F3SN dc welding machine circuit diagram relay omron diagram phase failure relay magnetic contactors key interlock solenoid IEC61496-1
Text: . (at approx. 1,800 operations/h, rated load) Failure rate ( P level) (reference value) Ambient


Original
PDF G9SA-300-SC relay 24v omron hot air gun fan controller circuit carbon brush motor F3SN dc welding machine circuit diagram relay omron diagram phase failure relay magnetic contactors key interlock solenoid IEC61496-1
2011 - F3SP-B1P

Abstract: F39-MLG F39-ST1 F39-JCR5A F3SN-A0937P70 omron Communication cables pin diagram F39-JC3B-D F3SH-A09P03 F3SH-A09P03-01 F3SN-A1237P70
Text: type Setting tool connection Safety category Detection capability Beam gap ( P ) Number of beams (n , mm PH = n × P Opaque objects: 25 mm in diameter 15 mm 13 to 120 217 to 1822 mm PH = (n ­ 1) × P + 37 Opaque objects: 40 mm in diameter 30 mm 7 to 60 217 to 1807 mm PH = (n ­ 1) × P + 37 -Opaque objects: 70 mm in diameter 60 mm 5 to 30 277 to 1777 mm PH = (n ­ 1) × P + 37 900 mm 300 mm 4 -F3SN-A@@@@P25 , capability Beam gap ( P ) Number of beams (n) Protective height (PH) Lens diameter Operating range Response


Original
PDF
2007 - transistor A1046

Abstract: A1046 k a1046 a1746 A1046 transistor F39-MLG2134 transistor c 6073 circuit diagram F39-MLG F39-MLG1626 F39-MLG0406
Text: F3SLA1570 P30 F3SLA1746 P30 F3SLA1920 P30 F3SLA2095P 30 0.3 to 20 m Beam gap ( P , F3SL Connection with OMRON G9SA- 301 Safety Relay Unit (Category 4) When connecting the F3SL to the G9SA- 301 , disable the F3SL's start/restart interlock and the external relay (MPCE) monitoring functions, and use the equivalent functions in the G9SA- 301 instead. Receiver Timing Chart Emitter


Original
PDF
Supplyframe Tracking Pixel