The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
STELLARIS-3P-EXPLO-NETX-TCPIP Texas Instruments NetX
STELLARIS-3P-MICDI-SMXFLOG-FS Texas Instruments smxFLog
STELLARIS-3P-UTASK-CANOPENLIB-PGRT Texas Instruments CANopen Library
STELLARIS-3P-GUANG-SMARTPROCH-PGRT Texas Instruments SmartPRO (Chinese)
STELLARIS-3P-MICRI-USUSBOTG-STACK Texas Instruments C/USB-OTG
STELLARIS-3P-SMCSG-EMBOS-RTOS Texas Instruments embOS
SF Impression Pixel

Search Stock

Bel Fuse
FXP6000-48-S AC/DC Power Supply Single-OUT 48V 175A 6KW - Bulk (Alt: FXP6000-48-S) FXP6000-48-S ECAD Model
Distributors Part Package Stock Lead Time Min Order Qty 1 10 100 1,000 10,000 Buy
Avnet FXP6000-48-S Bulk 0 12 Weeks 40 - - - - - Get Quote
Bel Power Solutions
FXP6000-48-S FXP6000-48-S ECAD Model
Distributors Part Package Stock Lead Time Min Order Qty 1 10 100 1,000 10,000 Buy
Onlinecomponents.com FXP6000-48-S 0 - $14228.04 $4847.73 $4847.73 $4847.73 Buy Now

FXP6000-48-S datasheet (1)

Part ECAD Model Manufacturer Description Type PDF
FXP6000-48-S FXP6000-48-S ECAD Model Power-One Distributed Power Front-End Original PDF

FXP6000-48-S Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2005 - Not Available

Abstract: No abstract text available
Text: -32-240 FXP6000-32- S (NOTE 2) FXP6000-48-240 FXP6000-48-S (NOTE 2) 32V 32V 48V 48V 180 to 264 180 to 264 or , ) INPUT VOLTAGE RANGE SELECT MODULE ROTATE 180 DEGREES FOR 240 VAC WHEN USING THE FXP6000-32- S OR FXP6000-48-S , Models: 48V Models: 32V Models: 48V Models: 30.4 45.6 32 48 33.6 50.4 5600 6000 175 125 V , voltage to rise from 10% to 90%. % % p-p % A µs % s ms 0 400 3 3 100 Interface Signals and , and shutdown. Latching shutdown. Latch style overvoltage protection. FXP6000-32: FXP6000- 48


Original
PDF FXP6000 FXP7000) FXC6000 FXC7000) FRV7000 FRV7000)
2004 - FRV7000

Abstract: No abstract text available
Text: LOAD REGULATION (NOTE 1) INITIAL SETTING ACCURACY FXP6000-32-240 FXP6000-32- S (NOTE 2) FXP6000-48-240 FXP6000-48-S (NOTE 2) 32V 32V 48V 48V 180 to 264 180 to 264 or 342 to 528 180 to 264 180 to 264 or , SELECT MODULE ROTATE 180 DEGREES FOR 240 VAC WHEN USING THE FXP6000-32- S OR FXP6000-48-S MODELS LOCK , : 32V Models: 48V Models: 30.4 45.6 32 48 33.6 50.4 5600 6000 175 125 V Watts A % 85 88 , from 10% to 90%. % % p-p % A µs % s ms 0 400 3 3 100 Interface Signals and Protection


Original
PDF FXP6000 FXP7000) FXC6000 FXC7000) FRV7000 FRV7000)
2004 - FXP7000

Abstract: FXP6000-48-240
Text: LOAD REGULATION (NOTE 1) INITIAL SETTING ACCURACY FXP6000-32- S (NOTE 2) 32V FXP6000-48-240 48V FXP6000-48-S (NOTE 2) 48V 180 to 264 or 342 to 528 180 to 264 180 to 264 or 342 to 528 30.5 to 33.5V , DEGREES FOR 240 VAC WHEN USING THE FXP6000-32- S OR FXP6000-48-S MODELS LOCK HANDLE RELEASE 2.437 , Models: 48V Models: 32V Models: 48V Models: 32V Models: 48V Models: 30.4 45.6 32 48 33.6 50.4 , after power-up. Time required for output voltage to rise from 10% to 90%. % % p-p % A µs % s ms


Original
PDF FXP6000 FXP7000) FXC6000 FXC7000) FRV7000 FRV7000) FXP7000 FXP6000-48-240
Not Available

Abstract: No abstract text available
Text: Selections MODEL OUTPUT VOLTAGE FXP6000-32- S (NOTE 2) 32V FXP6000-48-S (NOTE 2) 48V INPUT VOLTAGE , FXP6000-48-S MODELS INPUT VOLTAGE DISPLAY CUTOUT 2.437" (61.90mm) 0.521" (13.24mm) LOCK , : 48V Models: NOM MAX 30.4 45.6 32 48 33.6 50.4 5600 6000 175 125 85 88 88 , µs % s ms 0 Interface Signals and Protection PARAMETER (NOTE 1,2) DESCRIPTION/CONDITIONS , protection. FXP6000-32: FXP6000- 48 : Resistance to logic ground upon insertion of supply. Maximum load


Original
PDF FXP6000 FXP7000) FXC6000 FXC7000) FRV7000 FRV7000) MCD10161
FXC6000-48

Abstract: FXP6000 FXP6000-48
Text: Available · 200 to 480VAC Front-Panel Selectable FXP6000 HOT-PLUGGABLE MODEL MODEL FXP6000- 48 , to 48.10V CHASSIS-MOUNTABLE MODEL MODEL FXC6000- 48 NOTES: 1) With Remote Sense connected , required for output voltage to rise from 10% to 90%. 45.6 48 50.4 V 6000 125 Watts A % , Time 88 91 0.2 0.75 2.0 1 2 0 % % p-p 400 2 2 100 % A µs % s ms , 128 2.2 133 1.0 1.0 134 25 % ms V V A V % ±3 ± 4.8 100 ±4 ±5.0 ±5


Original
PDF FXC/FXP6000 FXC/FXP6000 50-PIN FRV6000 FRV6000) FXC6000-48 FXP6000 FXP6000-48
2005 - 702-32-01107

Abstract: 1648420-1 FXC6000 FXC7000 FXP6000 FXP6000-32-S FXP6000-48-S FXP7000 elcon
Text: . Hot-Pluggable Model Selections MODEL OUTPUT VOLTAGE FXP6000-32- S (NOTE 2) 32V FXP6000-48-S (NOTE 2) 48V , OR FXP6000-48-S MODELS INPUT VOLTAGE DISPLAY CUTOUT 2.437" (61.90mm) 0.521" (13.24mm , : 48V Models: 32V Models: 48V Models: NOM MAX 30.4 45.6 32 48 33.6 50.4 5600 6000 , 400 3 3 100 % A µs % s ms 0 Interface Signals and Protection PARAMETER (NOTE 1,2 , shutdown. Latch style overvoltage protection. FXP6000-32: FXP6000- 48 : Resistance to logic ground upon


Original
PDF FXP6000 FXP7000) FXC6000 FXC7000) FRV7000 FRV7000) 702-32-01107 1648420-1 FXC7000 FXP6000-32-S FXP6000-48-S FXP7000 elcon
2003 - FXP7000

Abstract: No abstract text available
Text: ACCURACY FXP6000- 48 48V 45.6V to 50.4V 125A 0.15% 0.2% 47.90V to 48.10V NOTES: 1 , . Time required for output voltage to rise from 10% to 90%. 45.6 48 50.4 6000 125 V Watts A % 88 91 0.2 0.75 2.0 0.2 1 2 0 % % p-p % A µs % s ms 0 400 3 3 100 Interface Signals and , -315 -250 12.5 0 0 315 500 5 10 0.10 1.0 1.0 134 65 500 129 2.2 21 ±3 ± 4.8 100 55.2 ±4 ±5.0 , 2.5 ASL Ft. °C °C %/°C %RH GPK GPK Grms cfm m3/min lfm m/ s lb kg Weight 29 13 NUCLEAR AND


Original
PDF FXP6000 480VAC FRV7000 FRV7000) FXP7000
2004 - FXP6000-48

Abstract: FXP7000 pl 504 FXP Diode
Text: FXP6000-32 FXP6000- 48 32V 48V 30.5 to 33.5V 45.6V to 50.4V 175A 125A 0.2% 0.15% 0.2% 0.2 , (208Vac). FXP6000-32: FXP6000- 48 : FXP6000-32: FXP6000- 48 : FXP6000-32: FXP6000- 48 : FXP6000-32: FXP6000- 48 : 30.4 45.6 32 48 33.6 50.4 5600 6000 175 125 V Watts A % 85 88 88 91 0.2 0.75 2.0 0.2 1 2 , %. % % p-p % A µs % s ms 0 400 3 3 100 Interface Signals and Protection PARAMETER (NOTE 1,2 , sink). (NOTE 3) Straight line current limit (above approx. 5V Vout). FXP6000-32: FXP6000- 48 : Signal


Original
PDF FXP6000 480VAC FXP7000) FXC6000 FXC7000) FRV7000 FRV7000) FXP6000-48 FXP7000 pl 504 FXP Diode
2010 - rv700

Abstract: No abstract text available
Text: LOAD REGULATION (NOTE 1) INITIAL SETTING ACCURACY FXP6000-32- S (NOTE 2) 32V FXP6000-48-S (NOTE 2 , ) INPUT VOLTAGE RANGE SELECT MODULE ROTATE 180 DEGREES FOR 240 VAC WHEN USING THE FXP6000-32- S OR FXP6000-48-S , Models: 30.4 45.6 32 48 33.6 50.4 5600 6000 175 125 V Watts A % 85 88 88 91 0.2 0.75 , 10% to 90%. % % p-p % A µs % s ms 0 400 3 3 100 Interface Signals and Protection , and shutdown. Latching shutdown. Latch style overvoltage protection. FXP6000-32: FXP6000- 48


Original
PDF FXP6000 FXP7000) FXC6000 FXC7000) FRV7000 FRV7000) MCD10161 rv700
2000 - Not Available

Abstract: No abstract text available
Text: -24 FXP6000-24 FXP1000- 48 FXP6000- 48 24V 24V 48V 48V 22.8V to 25.2V 22.8V to 25.2V 45.6V to 50.4V 45.6V , (NOTE 1) RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY FXC1000-24 FXC6000-24 FXC1000- 48 FXC6000- 48 24V 24V 48V 48V 22.8V to 25.2V 22.8V to 25.2V 45.6V to 50.4V 45.6V to 50.4V 33.6A 200A


Original
PDF FXC/FXP1000 FXC/FXP6000 180kW
NHC3011-5

Abstract: DNA 1005 POWER 12v 28V 3A 60W DC-DC MAP55-1024 SPM5 "power-one" spm5 MPB125 powcom LM1501 MAP110-4004
Text: -1048 48 45.6 to 50.4 125 180 to 528 6000 FXC6000- 48-S 48 45.6 to 50.4 145 180 to 528 7000 FXC7000- 48-S 24 and 28Vout · · · · 80% Typical Efficiency w/PFC Single , compatible control of outputs from 12 to 48 VDC · Chassis or hot-swap rack mount · Up to 525 amps per , K 38 M 39 S 39 P 40 Q 41 www.power-one.com 2 Courtesy of Steven Engineering , Railway and Rugged Products Overview Cassette Products M 42 H 42 35 S 43 S /PFC 43 K


Original
PDF 94080-6370-Main 588-9200-Outside 258-9200-www NHC3011-5 DNA 1005 POWER 12v 28V 3A 60W DC-DC MAP55-1024 SPM5 "power-one" spm5 MPB125 powcom LM1501 MAP110-4004
48 VOLT 20AMP battery charger

Abstract: lm1785 BP1601 ZY2105 qts48t46096 MPB150 HBD060ZGE-A PSR53-7 40IMX35D05D15-8 FXP7000-48-S
Text: DC-DC LOK Series 48 W Series, Includes EN50155 Models 48 X Series with PFC 49 Battery , 58 H 59 M 52 S 53 S 59 S /PFC 59 K 59 P 56 Q 54 K/PFC KP/PFC 59 , 51.2 to 54.2 4.8 HHS05Z55 HHS04 & HHS05 2.40 x 2.28 x 0.42 inch 61.0 x 57.9 x 10.7 mm , SQ24T15033* 18 to 36 5 4 to 5.5 10 SQ24T10050* 18 to 36 6 4.8 to 6.6 8 , 20 SQE48T20050 2.30 x 0.90 x 0.28 inch 58.4 x 22.8 x 7.1 mm 36 to 75 6 4.8 to 6.6


Original
PDF LKP5662-7R LKP5660-7R LKP5661-5R 48 VOLT 20AMP battery charger lm1785 BP1601 ZY2105 qts48t46096 MPB150 HBD060ZGE-A PSR53-7 40IMX35D05D15-8 FXP7000-48-S
2010 - 1648420-1

Abstract: 4468M FRV7000 296-22-01100
Text: SETTING ACCURACY FXP7000- 48-S 48V 180 to 264 or 342 to 528 45.6V to 50.4V 145A 0.15 , 10% to 90%. 45.6 48 50.4 7000 145 V Watts A % 88 91 0.2 0.75 2.0 0.2 1 2 0 % % p-p % A µs % s ms 0 800 3.2 3 100 Interface Signals and Protection PARAMETER (NOTE 1,2 , V A V A % % ms V V 0.5 0.10 0 0.5 5 10 0.10 1.0 1.0 156 90 500 149 2.2 25 ±3 ± 4.8 , /min lfm m/ s lb kg Weight 29 13 MCD10162 Rev. 1.0, 04-Jun-10 Page 3 of 8


Original
PDF FXP7000 MCD10162 04-Jun-10 1648420-1 4468M FRV7000 296-22-01100
Not Available

Abstract: No abstract text available
Text: (up to) 480VAC, delta or wye. Hot-Pluggable Model OUTPUT VOLTAGE MODEL FXP7000- 48-S NOTES , . Continuous duty rating. 45.6 48 50.4 V 7000 145 Watts A % Ripple & Noise Overshoot , %. 88 91 0.2 0.75 2.0 0.2 1 2 0 % % p-p 800 3.2 3 100 % A µs % s ms 0 , 500 1.0 1.0 156 149 2.2 25 90 mA/A mA % ms V V A V A ±3 ± 4.8 100  , imbalance, output good, interlock open, and supply inhibited. The FXP also provides 4 LED’ s indicating


Original
PDF FXP7000 FXP7000 MCD10162 04-Jun-10
2012 - pl 504

Abstract: FXP7000-48
Text: REGULATION LOAD REGULATION (NOTE 1) INITIAL SETTING ACCURACY FXP7000- 48-S NOTES: 48V 180 to , . Time required for output voltage to rise from 10% to 90%. 45.6 48 50.4 7000 145 V Watts A % 88 91 0.2 0.75 2.0 0.2 1 2 0 % Ripple & Noise % p-p % A µs % s ms Overshoot , 2.2 25 ±3 ± 4.8 100 55.2 ±4 ±5.0 ms V V A V A % % ms V V ±5 ±5.2 57.6 1000 60.0 1.0 , 2.8 ASL Ft. °C °C %/°C %RH GPK GPK Grms cfm m3/min lfm m/ s lb kg Weight 29 13 MCD10162 Rev


Original
PDF FXP7000 MCD10162 04-Jun-10 pl 504 FXP7000-48
2004 - 064N

Abstract: 7483 FXC6000 FXC6000-48 FXC6000-48-240 FXC6000-48-S IEC60950-1
Text: well as (up to) 480VAC, D or Y. Chassis-Mountable Model OUTPUT VOLTAGE MODEL FXC6000- 48 48V FXC6000-48-240 48V FXC6000- 48-S (NOTE 2) 48V INPUT VOLTAGE RANGE (VAC) ADJUSTMENT RANGE , VAC WHEN USING THE FXC6000- 48-S MODEL MATING CONNECTOR: CONNECTOR SHELL. AMP PN 748365-1 , from 10% to 90%. 45.6 48 50.4 V 6000 125 Watts A % Ripple & Noise Overshoot , 0.2 1 2 0 % % p-p 400 3 3 100 % A µs % s ms 0 Interface Signals and


Original
PDF FXC6000 FXC6000 127mm) 26-PIN FXC6000-48-S 480VAC FXC6000-48 FXC6000-48-240 064N 7483 FXC6000-48 FXC6000-48-240 IEC60950-1
2006 - Not Available

Abstract: No abstract text available
Text: FXC7000- 48-S INPUT VOLTAGE RANGE 3-PHASE (VAC) ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT LINE , 48 50.4 V 7000 145 Watts A % Ripple & Noise Overshoot / Undershoot Minimum , % % p-p 800 3.2 3 100 % A µs % s ms 0 Interface Signals and Internal , V A ±3 ± 4.8 100 ±4 ±5.0 ±5 ±5.2 % % ms 55.2 57.6 1000 60.0 V , , output good, interlock open, and supply inhibited. The FXP also provides 4 LED’ s indicating output


Original
PDF FXC7000 FXC7000 127mm) 26-PIN 480VAC
2004 - 7483

Abstract: EN61000-4-2 FXC6000 FXC6000-48-S IEC60950-1
Text: Y. Chassis-Mountable Model OUTPUT VOLTAGE MODEL FXC6000- 48-S (NOTE 2) 48V INPUT , voltage to rise from 10% to 90%. 45.6 48 50.4 V 6000 125 Watts A % Ripple & Noise , 0.75 2.0 0.2 1 2 0 % % p-p 400 3 3 100 % A µs % s ms 0 Interface Signals , 0.10 500 1.0 1.0 134 129 2.2 21 65 mA µA/A µA/A % ms V V A V A ±3 ± 4.8 , m/ s lb kg NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for


Original
PDF FXC6000 FXC6000 127mm) 26-PIN 480VAC 7483 EN61000-4-2 FXC6000-48-S IEC60950-1
2006 - 7483

Abstract: EN61000-4-2 FXC7000 FXC7000-48-S 892m
Text: , delta or wye. Chassis-Mountable Model OUTPUT VOLTAGE MODEL FXC7000- 48-S INPUT VOLTAGE , power-up. Time required for output voltage to rise from 10% to 90%. 45.6 48 50.4 V 7000 , 100 % A µs % s ms 0 Interface Signals and Internal Protection PARAMETER (NOTE 1,2 , 0.10 500 1.0 1.0 156 149 2.2 25 90 mA/A mA % ms V V A V A ±3 ± 4.8 100 , lfm m/ s lb kg NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended


Original
PDF FXC7000 FXC7000 127mm) 26-PIN 480VAC 7483 EN61000-4-2 FXC7000-48-S 892m
2004 - Not Available

Abstract: No abstract text available
Text: voltages as well as (up to) 480VAC, D or Y. Chassis-Mountable Model OUTPUT VOLTAGE MODEL FXC6000- 48-S , required for output voltage to rise from 10% to 90%. 45.6 48 50.4 V 6000 125 Watts A % , Time 88 91 0.2 0.75 2.0 0.2 1 2 0 % % p-p 400 3 3 100 % A µs % s ms , V A ±3 ± 4.8 100 ±4 ±5.0 ±5 ±5.2 % % ms 55.2 57.6 1000 60.0 V , , output good, interlock open, and supply inhibited. The FXP also provides 4 LED’ s indicating output


Original
PDF FXC6000 FXC6000 127mm) 26-PIN 480VAC
2004 - 7483

Abstract: EN61000-4-2 FXC6000 FXC6000-48-S IEC60950-1
Text: Y. Chassis-Mountable Model OUTPUT VOLTAGE MODEL FXC6000- 48-S (NOTE 2) 48V INPUT , voltage to rise from 10% to 90%. 45.6 48 50.4 V 6000 125 Watts A % Ripple & Noise , 0.75 2.0 0.2 1 2 0 % % p-p 400 3 3 100 % A µs % s ms 0 Interface Signals , 0.10 500 1.0 1.0 134 129 2.2 21 65 mA µA/A µA/A % ms V V A V A ±3 ± 4.8 , cfm m3/min lfm m/ s lb kg NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not


Original
PDF FXC6000 FXC6000 64N/M) 127mm) 26-PIN 480VAC 7483 EN61000-4-2 FXC6000-48-S IEC60950-1
"power-one" spm5

Abstract: NET1 MAP55-1024 NET1-4230 PFC375-1028 HPM5 MWE30-11 MAP110-4004 NHS3000 CP323-A
Text: . . . . . . . . . . . . . . . . . .44 S Series, 100 Watts, 1 or 2 Outputs . . . . . . . . . . . . . , . . . . . . . . . . . . . 48 NUCLEAR AND MEDICAL APPLICATIONS- Power-One products are not , , 1 to 3 Outputs . . . . . . . . . . . . . . . . . . . . . . . . . .75 S Series, 100 Watts, 1 and 2 , manufactures complete telecom power plant systems which provide 24 and 48 volt outputs. Please contact your , outputs from 1 to 48 volts. Features include a comprehensive array of interface signals, extensive input


Original
PDF 12Vout 15Vout 48Vout "power-one" spm5 NET1 MAP55-1024 NET1-4230 PFC375-1028 HPM5 MWE30-11 MAP110-4004 NHS3000 CP323-A
LWN2880-6

Abstract: No abstract text available
Text: AC-DC Cassettes K 47 M 50 H 50 M 44 S 45 S 51 S /PFC 51 K 51 P 48 Q , . Z-One® Digital Power TM No-Bus POL Converters Power-One’ s No-Bus™ POL converters provide , Programmable POL Solutions Power-One’ s bus-programmable POL solutions combine many innovative operating , 52.5 50 to 53 3.8 HHS04Z52 36 to 75 53.7 51.2 to 54.2 4.8 HHS04 & HHS05 2.40 x , 4 to 5.5 10 SQ24T10050 18 to 36 6 4.8 to 6.6 8 SQ24T08060 18 to 36 12


Original
PDF
MOV surge protection circuit diagram

Abstract: 500 watt inverter 12v dc to 220 ac inverter 500w project report Amp. mosfet 1000 watt 12 volt dc to 220 volt ac inverter inverter 12v 36v high power 2000w dc to ac inverter Circuit diagram 500w inverter circuit diagram 1000 watts power amp circuit diagram 1000 watts ups circuit diagram pictures
Text: extensive transient protection. from 1.0 to 48 VDC. and EN60555-2. · Vibration tested at 6 GRMS, 3 , /FILTER & SYNC CIRCUITS #2, #3, #4 OMITTED FOR CLARITY S Y S T E M P O W E R DC OUTPUT , CLARITY DC OUTPUT MODULE #7 RECTIFIER & FILTER MOSFET POWER SWITCH B U S RECTIFIER , damage is differential voltage events (between the lines), not common mode (between line( s ) and ground). , . Results The data on the following pages present the resulting field reliability of 48 modules. This data


Original
PDF 48VDC. reliabi31 230/480VAC FXP6000 FXC7000 FXP7000 FXP6000 FXC7000 MOV surge protection circuit diagram 500 watt inverter 12v dc to 220 ac inverter 500w project report Amp. mosfet 1000 watt 12 volt dc to 220 volt ac inverter inverter 12v 36v high power 2000w dc to ac inverter Circuit diagram 500w inverter circuit diagram 1000 watts power amp circuit diagram 1000 watts ups circuit diagram pictures
2004 - Not Available

Abstract: No abstract text available
Text: code E1 E2 E3a E3 D1 D2 D3 D4 D5 B Z X Y V U T S L 4.8 4.8 4.8 4.8 6.0 6.0 6.0 6.0 6.0 6.0 7.1 7.7 7.1 , dielectric with simple mold-less construction s Features · Small in size · Applicable for reflow soldering s Recommended Applications · Coupling · By-pass · General purpose s Explanation of Part , 250VDC J ±5% K ±10% 9 V Z 12mm 16mm 24mm s Specifications Category temp.range (Including , 240°C max. and 60 s max.at more than 220°C (Temp.at cap.surface) Design, Specifications are subject


Original
PDF 16VDC 50VDC 100VDC 250VDC 16VDC, 50VDC 100VDC 50VDC1
Supplyframe Tracking Pixel