The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
CAT-NTC0031 TE Connectivity (CAT-NTC0031) MBD9-PROBE
CAT-NTC0037 TE Connectivity (CAT-NTC0037) MBD9-PROBE
CAT-NTC0038 TE Connectivity (CAT-NTC0038) MBD9-PROBE
CAT-NTC0030 TE Connectivity (CAT-NTC0030) MBD9-PROBE
CAT-NTC0035 TE Connectivity (CAT-NTC0035) MBD9-PROBE
CAT-NTC0029 TE Connectivity (CAT-NTC0029) MCD PROBE

FLUKE 80k-40 probe Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
uln20004a

Abstract: schematic diagram dc inverter 1000W SCHEMATIC 1000w inverter FLUKE 80k-40 probe uln20004 67F085 hv 1000 inverter schematic diagram 1000W switching mode inverter schematic diagram SCHEMATIC 1000w power amp 80K-40
Text: when the power supply is holding voltage on a capacitor, any HV probe and DVM combination can be used. The Fluke 80K-40 probe with any 10M input resistance DVM is adequate up to 40kV. Building a simple , resistors, including the one in the Fluke probe , exhibit a negative voltage coefficient, changing by up to , this problem. Making a pulsed measurement with an oscilloscope requires a compensated HV probe having a wide bandwidth. Simply connecting a DC probe , through the proper resistance, into a scope yields


Original
PDF CD40106BE ULN20004A MC7815UC LM339N LM324N MC1458P1 1N914 MUR3060PT 2N2907 IRFD113 uln20004a schematic diagram dc inverter 1000W SCHEMATIC 1000w inverter FLUKE 80k-40 probe uln20004 67F085 hv 1000 inverter schematic diagram 1000W switching mode inverter schematic diagram SCHEMATIC 1000w power amp 80K-40
1978 - 939335

Abstract: fluke 73 Repair manual AC voltmeter applications Fluke 111 Multimeter repair AC digital voltmeter diagram resistor kit 939335 AC voltmeter connection diagram 80K-40 Fluke 111 Multimeter AC voltmeter diagram free
Text: Maintenance ® Performance Test Verify the probe accuracy by measuring a 25 kV dc ±0.25% voltage source. When used with a compatible dc voltmeter, the probe should measure the source with ±1% accuracy. No calibration adjustments are provided. 80K-40 High Voltage Probe Cleaning Use a soft , sure the 80K-40 is dry before reuse. LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product , warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke


Original
PDF 80K-40 80K-40. 80K-40 80K-40: 939335 fluke 73 Repair manual AC voltmeter applications Fluke 111 Multimeter repair AC digital voltmeter diagram resistor kit 939335 AC voltmeter connection diagram Fluke 111 Multimeter AC voltmeter diagram free
2002 - schematic diagram dc inverter 1000W

Abstract: SCHEMATIC 1000w inverter power supply hv laser co2 Design 1000W inverter using 2 parallel transformer schematic diagram welding inverter control VD60-8 DIODE MSDS HV transformer 5kv 80K-40 FLUKE 80k-40 probe
Text: when the power supply is holding voltage on a capacitor, any HV probe and DVM combination can be used. The Fluke 80K-40 probe with any 10M input resistance DVM is adequate up to 40kV. Building a simple , resistors, including the one in the Fluke probe , exhibit a negative voltage coefficient, changing by up to , an oscilloscope requires a compensated HV probe having a wide bandwidth. Simply connecting a DC probe , through the proper resistance, into a scope yields a slow response only adequate for low rep


Original
PDF 00A/102A/152A/202A 2011629XUS 01000680revD schematic diagram dc inverter 1000W SCHEMATIC 1000w inverter power supply hv laser co2 Design 1000W inverter using 2 parallel transformer schematic diagram welding inverter control VD60-8 DIODE MSDS HV transformer 5kv 80K-40 FLUKE 80k-40 probe
computer schematic power supply circuit diagram

Abstract: Digital ohm meter by using IL 7107 N FLUKE 79 manual Fuse RH A4 2A 250V SCHEMA DC INVERTER 12 VOLT TO 220 dwa 108 a IC LM339N FLUKE 83 Regulated Power Supply Schematic Diagram FLUKE 77 series II service manual Dow Corning DC-4
Text: on a capacitor, any HV probe and DMM combination can be used. The Fluke 80K-40 probe with any lOMil , resistors is also very straightforward. Keep in mind that all HV resistors, including the one in the Fluke probe , exhibit a negative voltage coefficient, changing by up to 4% from zero to max voltage. Derating , with an oscilloscope requires a compensated HV probe having a wide bandwidth. Simply connecting a DC probe , through the proper resistance, into a 'scope yields a slow-response adequate• for only low rep


OCR Scan
PDF 89/336/EEC) 220VAC computer schematic power supply circuit diagram Digital ohm meter by using IL 7107 N FLUKE 79 manual Fuse RH A4 2A 250V SCHEMA DC INVERTER 12 VOLT TO 220 dwa 108 a IC LM339N FLUKE 83 Regulated Power Supply Schematic Diagram FLUKE 77 series II service manual Dow Corning DC-4
IC LM339N

Abstract: IC LM324N 67f085 p8ml el panel inverter Schematic Digital ohm meter by using IL 7107 N IRKH71-80 FLUKE 80k-40 probe hv 1000 inverter schematic diagram 4000w inverter circuit
Text: probe and DMM combination can be used. The Fluke 80K-40 probe with any lOMil input resistance DMM is , straightforward. Keep in mind that all HV resistors, including the one in the Fluke probe , exhibit a negative , a compensated HV probe having a wide bandwidth. Simply connecting a DC probe , through the proper , probes, the pulsed probe resistor voltage coefficient is a problem. In addition, damage to the resistors , probe and a good choice up to 4 OkV. Measurements accurate to better than 0.1% can be achieved using a


OCR Scan
PDF 89/336/EEC) 220VAC IC LM339N IC LM324N 67f085 p8ml el panel inverter Schematic Digital ohm meter by using IL 7107 N IRKH71-80 FLUKE 80k-40 probe hv 1000 inverter schematic diagram 4000w inverter circuit
2002 - Not Available

Abstract: No abstract text available
Text: Fluke 789 ProcessMeter Double your power. ™ Technical Data w Ne The Fluke 787 , Fluke 789 ProcessMeter. The 789 has a display that’s not only twice as large, but also twice as , while carrying a lot less. Key new features of the Fluke 789 • • • • • • • â , years 80T-IR Infrared Temperature Probe 80TK Thermocouple Module 80T-150U Universal Temperature Probe TL20 / TL22 / TL24 / TL26 / TL28 / TL40A Test Lead Sets AC20 / AC80 Clips TP20 Industrial Test


Original
PDF 36-FLUKE
2000 - FLUKE 1520

Abstract: FLUKE 87-3 Prepaid Gas Meter fluke 80k-40 FLUKE 75 80K-40 fluke 75 meter manual SP82 EN61010-1 fluke 75 service manual
Text: ® 1520 MegOhmMeter Calibration Manual PN 1592594 November 2000 © 2000 Fluke , companies. Limited Warranty & Limitation of Liability Each Fluke product is warranted to be free from , warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke 's opinion, has been misused , . Fluke warrants that software will operate substantially in accordance with its functional


Original
PDF 750VAC FLUKE 1520 FLUKE 87-3 Prepaid Gas Meter fluke 80k-40 FLUKE 75 80K-40 fluke 75 meter manual SP82 EN61010-1 fluke 75 service manual
Fluke 179 Multimeter circuit diagram

Abstract: FLUKE 77 series II service manual fluke 741 Repair manual SERVICE MANUAL OF FLUKE 175 FLUKE 77 series II manual Fluke 19 Multimeter circuit diagram metrix OX Fluke Multimeter circuit diagram transistor b1040 Fluke 77 user manual
Text: older assemblies. John Fluke Mfg. Co., Inc. · P.O. Box 43210 · Mountlake Terrace, Washington 98043 Rev. 1 8/77 Rev. 2 5/78 Dear Customer: Congratulations! We at Fluke are proud to present you with , , Fluke stands behind your 8020A with a full one-year warranty and a worldwide service organization. I f , H N FLUKE MFG. CO., INC. static awareness A Message From John Fluke Mfg. Co., Inc. Some , techniques that are recommended. The Static Sensitive (S.S.) devices are identified in the Fluke technical


OCR Scan
PDF 802OA odel8020A Fluke 179 Multimeter circuit diagram FLUKE 77 series II service manual fluke 741 Repair manual SERVICE MANUAL OF FLUKE 175 FLUKE 77 series II manual Fluke 19 Multimeter circuit diagram metrix OX Fluke Multimeter circuit diagram transistor b1040 Fluke 77 user manual
Y8101

Abstract: Fluke 179 Multimeter circuit diagram FLUKE 79 series II multimeter diagram Fluke 19 Multimeter circuit diagram fluke 8012A fluke Y8101 FLUKE Clamp meter diagram FLUKE 8010a rms dc converter FLUKE 30 Clamp meter diagram FLUKE 79 III manual
Text: 8010A/8012A Digital Multimeters Instruction Manual FLUKE 8010A/8012A Digital Multimeters Instruction Manual P/N 491944 August 1978 Rev 2 1/85 ®1985, John Fluke Mfg. Co., Inc. All rights reserved. Litho in U.S.A. IF L U K E I - ® Dear Customer: Congratulations! We at Fluke are proud to , the manual. A s always, Fluke stands behind your instrument with a fu ll one-year warranty and a , complete operating and maintenance instructions for the Fluke Models 801OA and 8012A D igital Multimeters


OCR Scan
PDF 010A/8012A 012A-1701 012A-1101 Y8101 Fluke 179 Multimeter circuit diagram FLUKE 79 series II multimeter diagram Fluke 19 Multimeter circuit diagram fluke 8012A fluke Y8101 FLUKE Clamp meter diagram FLUKE 8010a rms dc converter FLUKE 30 Clamp meter diagram FLUKE 79 III manual
Y8101

Abstract: Fluke 8060A service manual Y8100 FLUKE 6010a manual 80J-10 Fluke 8060A Multimeter calibration manual eb 13001 transistor tfk bp w 41 FLUKE Clamp meter diagram FLUKE 83RF PROBE
Text: Fluke Mfg., Co. All rights reserved. Litho in U.S.A. FLUKE WARRANTY N otw ithstanding any provision of any agreem ent the follow ing w arranty is exclusive: The JO H N FLUKE MFG. CO. INC., warrants , covered by this w arranty. John Fluke Mfg. Co. Inc., w ill repair and calibrate an instrum ent returned , , OR ADEQUACY FOR ANY P ARTICULAR PURPOSE OR USE. JO HN FLUKE MFG. CO., INC. SHALL NOT BE LIABLE FOR , any (allure occurs, the following steps should be teken: 1. N o tify the JO HN FLUKE MFG. CO. INC


OCR Scan
PDF 90-days) Y8101 Fluke 8060A service manual Y8100 FLUKE 6010a manual 80J-10 Fluke 8060A Multimeter calibration manual eb 13001 transistor tfk bp w 41 FLUKE Clamp meter diagram FLUKE 83RF PROBE
schematic fluke 79

Abstract: Fluke 179 Multimeter circuit diagram FLUKE 79 manual fluke 741 Repair manual Fluke 19 Multimeter calibration manual transformer winding formula 220v Ac to 12v Dc TRANSISTOR REPLACEMENT GUIDE Fluke 19 Multimeter circuit diagram 8020a Fluke 77 user manual
Text: older assemblies. John Fluke Mfg. Co., Inc. · P.O. Box 43210 · Mountlake Terrace, Washington 98043 Rev. 1 8/77 Rev. 2 5/78 Dear Customer: Congratulations! We at Fluke are proud to present you with , , Fluke stands behind your 8020A with a fu ll one-year warranty and a worldwide service organization. I f , FLUKE MFG. CO., INC. static awareness A Message From John Fluke Mfg. Co., Inc. Some , are recommended. The Static Sensitive (S.S.) devices are identified in the Fluke technical manual


OCR Scan
PDF
2006 - Fluke 8060A service manual

Abstract: FLUKE 79 III manual FLUKE 79III manual COLOR tv tube charger circuit diagrams NORMA Installation tester LEM SERVICE MANUAL OF FLUKE 175 FLUKE 8060A multimeter FLUKE 77 series II service manual FLUKE 77 series II multimeter FLUKE 88 automotive manual
Text: Test Tools Catalog Volume one, 2007 Fluke Ti20 Thermal Imager Fluke 975 AirMeterTM Fluke 1587 Insulation Multimeter Find it. Fix it. Fast. Fluke 199C Color ScopeMeter® Test Tools Catalog Volume 37, 2007 Contents Fluke tools for: Commercial Electricians , . 5 Online resource centers. 6 Fluke test tool information , Three-Phase Power Logger, Norma 4/5000 Power Analyzers.29 Clamp Meters Fluke 345 and


Original
PDF 36-FLUKE Fluke 8060A service manual FLUKE 79 III manual FLUKE 79III manual COLOR tv tube charger circuit diagrams NORMA Installation tester LEM SERVICE MANUAL OF FLUKE 175 FLUKE 8060A multimeter FLUKE 77 series II service manual FLUKE 77 series II multimeter FLUKE 88 automotive manual
FLUKE 8840a specification

Abstract: FLUKE 8840a 700013 Y8101 FLUKE 83RF PROBE capacitor IH 104j 40 HMR 20 EQUIVALENT 40 RB 120 FLUKE 79 series II multimeter diagram fluke 8840 8840A instruction manual
Text: DIGITAL MULTIMETER Instruction Manual FLUKE . 8840A DIGITAL MULTIMETER Instruction Manual PN 879304 December 1991 Rev. 2, 4/94 ©1994 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies FLUKE MULTIMETER SAFETY The Fluke 8840A Digital Multimeter has been designed and tested according to IEC Publication 348 , 8840A DIGITAL MULTIMETER The Fluke 8840A D igital M ultimeter is a highperformance 5-1/2 digit


OCR Scan
PDF U101-24 U101-25 FLUKE 8840a specification FLUKE 8840a 700013 Y8101 FLUKE 83RF PROBE capacitor IH 104j 40 HMR 20 EQUIVALENT 40 RB 120 FLUKE 79 series II multimeter diagram fluke 8840 8840A instruction manual
NIST-175

Abstract: accuracy of K type thermocouple fluke FLUKE 75 FLUKE FLUKE fluke 29 II 80BK-A fluke 54 IR thermometer fluke 52 ITS-90
Text: preparation, Fluke has a probe to meet your needs. All probes are K-Type unless noted otherwise. 80PK-EXT and , accuracy. Wherever you go. The new Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.30°C) in a rugged, handheld test tool. ® 1 TEST & MEASUREMENT Fluke 51 Series II and Fluke 52 Series II Products Features: Large Backlit Dual Display Shows Any Combination of , Holster, 80PK-1 Bead Probe Thermocouple Recommended Accessories: TPAK Meter Hanging Kit, 80PK-27 Surface


Original
PDF T5-600 FLUKE-62/322/1AC FLUKE-62/T FLUKE-T5-600/62/1AC NIST-175 accuracy of K type thermocouple fluke FLUKE 75 FLUKE FLUKE fluke 29 II 80BK-A fluke 54 IR thermometer fluke 52 ITS-90
1998 - Fluke 73 Multimeter

Abstract: No abstract text available
Text: the probe with a Fluke multimeter that is in the kChek™ or Automatic Selection mode (i.e. Fluke 16, Fluke 12B etc.). The input impedance in these modes is very low. • Make sure the probe tip is firmly , probe serviced. PN 690385 May 1998 ©1998 Fluke Corporation. All rights reserved. Printed in U.S.A , probe . 4 Note 5 The input impedance of the Autoranging mode on Fluke handheld digital , Probe Instruction Sheet Warranty LIMITED WARRANTY & LIMITATION OF LIABILITY This Fluke product


Original
PDF 80K-15 Fluke 73 Multimeter
2001 - Fluke 17 DMM

Abstract: No abstract text available
Text: DP120 differential voltage probe or a Fluke 190C Series instrument. Environmental According to , high impedance 10:1 probe , 40 MHz (1 black, included with Fluke 125, 124); ground leads with mini , RS-232 adapter/cable Optically Isolated USB interface cable Differential Voltage Probe for Fluke , , 100 or 60 MHz bandwidth Up to 2.5 GS/s real time • sampling per input Shop for Fluke , • Cursor measurements ( Fluke 124, 125) A dual input TrendPlot recorder • â


Original
PDF -36-FLUKE 1629083H Fluke 17 DMM
FLUKE-62-MAX

Abstract: laser thermometer 80PK-8 infrared temperature measure FLUKE 29 thermometer FLUKE-62 MAX
Text: for Fluke 66 and 68 Infrared Thermometer Holster Bead Probe Piercing Probe Surface Probe Immersion , distant room balancing checks, the Fluke infrared thermometers can take IR temperature measurements with , efficiently in more applications. Fluke Infrared Thermometer Features Backlit Display Comfortable Pistol , CONTROL Fluke 61 Infrared Thermometer Fluke 61 Features Take Temperature Readings in Less Than a Second Fluke 62-Max Infrared Thermometer Fluke 62-Max Features MIN, MAX, AVG and DIF Functions Hi and Lo


Original
PDF innov84 80PK-11 80PK-27 80PK-8 80PR-60 80PK-1 80PK-25 80PK-3A 80PK-22 80PK-24 FLUKE-62-MAX laser thermometer infrared temperature measure FLUKE 29 thermometer FLUKE-62 MAX
2008 - SCOPEMETER Fluke 99

Abstract: No abstract text available
Text: voltage probe Horizontal Max. sample rate (both channels simultaneously): Fluke 125, 124: 2.5 GS/s , between inputs, use DP120 differential voltage probe or a Fluke 190C Series instrument. Environmental , Optically Isolated USB interface cable Differential Voltage Probe for Fluke 120 Series Bus Health Test , €¢ Cursor measurements ( Fluke 124, 125) A dual input TrendPlot recorder • • Connect-and-View , , continuity and capacitance measurements • Full bandwidth, VPS40 10:1 40 MHz probe included standard


Original
PDF -36-FLUKE SCOPEMETER Fluke 99
2004 - Not Available

Abstract: No abstract text available
Text: ® 80PT-25 SureGrip Piercing Temperature Probe TM Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically connected to the output terminals. Introduction The 80PT-25 SureGripTM Piercing Temperature Probe is designed for use in liquids, gels, soft, and semi-hard materials. The probe , of the probe is protected from tip to handle by the stainless steel sheath. The 40-inch (1


Original
PDF 80PT-25 80PT-25 40-inch 792-mm 312-inch)
2004 - Fluke 19 Multimeter

Abstract: ANSI MC96.1 fluke 75 meter manual chromel alumel FLUKE 75 Fluke 77 Multimeter fluke 19 multimeter Fluke 19 SERVICE MANUAL OF FLUKE 175 accuracy of K type thermocouple fluke
Text: circuit to indicate if the connected probe is open. (All Fluke Temperature-measuring instruments have , ® 80PK-26 SureGrip Tapered Temperature Probe TM Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically connected to the output terminals. Introduction The 80PK-26 SureGripTM Tapered Temperature Probe is essentially a bead probe with a handle that can be used as a surface probe


Original
PDF 80PK-26 80PK-26 40-inch Fluke 19 Multimeter ANSI MC96.1 fluke 75 meter manual chromel alumel FLUKE 75 Fluke 77 Multimeter fluke 19 multimeter Fluke 19 SERVICE MANUAL OF FLUKE 175 accuracy of K type thermocouple fluke
2002 - IEC 1010-1 General Safety Requirements

Abstract: IEC-6LR61 standard Fluke 16 Multimeter reading milliamps dc 80I-110S Fluke 73 Multimeter 6LR61 FLUKE 36 100MVA
Text: Page 1 of 2, Document #2228 80i-110s AC/DC Current Probe ©2002 Fluke Corporation Rev. A-9/2002 80i-110s AC/DC Current Probe The ideal current probe for Fluke ScopeMeter® Test Tools Accurate , automotive circuits. The Fluke 80i-110s AC/DC Current Probe is designed to provide you with safe, high , frequency response of the Fluke 80i-110s AC/DC Current Probe from dc to 100 kHz supports a wide range of , , Document #2228 80i-110s AC/DC Current Probe ©2002 Fluke Corporation Rev. A-9/2002 Floating voltage


Original
PDF 80i-110s 80i-110s -36-FLUKE IEC 1010-1 General Safety Requirements IEC-6LR61 standard Fluke 16 Multimeter reading milliamps dc Fluke 73 Multimeter 6LR61 FLUKE 36 100MVA
2004 - SCOPEMETER Fluke 99

Abstract: FLUKE 75 series II multimeter fluke 75 meter manual FLUKE Clamp meter diagram PM9080 DPU-414 fluke bp120 FLUKE 70 series II multimeter FLUKE 30 Clamp meter diagram FLUKE 123
Text: Fluke ScopeMeters 3 GENERAL SPECIFICATIONS INPUT VOLTAGE RATINGS Maximum probe voltage 1,000V CAT , BP190 Fluke 123, 124 BP120 ( Fluke 123), BP130 ( Fluke 124) PM8907 BC190 10:1 voltage probe , lead set VPS40 high impedance 10:1 probe , 40 MHz (1 black, included with Fluke 124 only); HC120 , oscilloscope Two 5,000 counts true-rms digital multimeters Cursor measurements ( Fluke 124) A dual input , Input voltage Vertical resolution Accuracy Input impedance Fluke 199C Fluke 199B 200 MHz 1.7 ns


Original
PDF RS-232 10705-eng SCOPEMETER Fluke 99 FLUKE 75 series II multimeter fluke 75 meter manual FLUKE Clamp meter diagram PM9080 DPU-414 fluke bp120 FLUKE 70 series II multimeter FLUKE 30 Clamp meter diagram FLUKE 123
2010 - Not Available

Abstract: No abstract text available
Text: flexibility Technical Data The new Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms ac voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes. Additionally, the Fluke 376 includes the new iFlex™ flexible current probe expanding the measurement range to 2500 A ac while providing , . The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter. Measurement capability â


Original
PDF -36-FLUKE 834948A
2010 - Not Available

Abstract: No abstract text available
Text: flexibility Technical Data The new Fluke 374 and 375 clamp meters offer improved performance perfect for many current measurement situations. With true-rms ac voltage and current measurements, the Fluke 374 , with the new iFlex™ flexible current probe (sold separately) which expands the measurement range to , with fixed jaw • 2500 A ac current measurement with iFlex™ flexible current probe (sold , measurements on non-linear signals • Frequency measurement to 500 Hz with both jaw and iFlex™ ( Fluke


Original
PDF -36-FLUKE 3801511B
1993 - ANSI MC96.1

Abstract: fluke 75 meter manual Fluke 77 fluke 75 meter ANSI MC96.1 temperature measurements thermocouple accuracy of K type thermocouple fluke FLUKE 75 ANSI MC96.1 Type K Thermocouple Free MC96.1 Cold Junction Compensation
Text: ® 80PK-3A Type K Thermocouple Surface Probe Instruction Sheet WARNING TO AVOID ELECTRICAL SHOCK, DO NOT USE THIS PROBE WHEN VOLTAGES EXCEEDING 24V AC RMS OR 60 V DC ARE PRESENT.THE PROBE TIP , the probe is designed to deflect only .030" in normal operation. Any action which bends or pulls the strip out further from the tip will CONSIDERABLY reduce the life of the probe INTRODUCTION The 80PK-3A Type K Thermocouple Surface Probe is designed for measuring the temperature of flat or slightly


Original
PDF 80PK-3A 80PK-3A 40-inch 1-888-99-FLUKE 1-800-36-FLUKE ANSI MC96.1 fluke 75 meter manual Fluke 77 fluke 75 meter ANSI MC96.1 temperature measurements thermocouple accuracy of K type thermocouple fluke FLUKE 75 ANSI MC96.1 Type K Thermocouple Free MC96.1 Cold Junction Compensation
Supplyframe Tracking Pixel