The Datasheet Archive

Ericsson tma Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2003 - ERICSSON TMA KRY 112

Abstract: Ericsson tma ERICSSON dual band tma DDTMA Ericsson KRY 112 71 Ericsson TMA 1900 Tower Mounted Amplifiers ericsson ericsson BTS and antenna installation RBS 2106 ericsson kry 112
Text: share network frequencies. This Ericsson dual duplex TMA eliminates any problems this could cause, by , TMA for Ericsson GSM 1900 MHz RBSs. · Full 60 MHz bandwidth ­ futureproof and logistically simple , Ericsson TMA + BTS fulfils ETSI requirements Mechanical specifications Dimensions (H x W x D) Weight , antenna, this Tower Mounted Amplifier ( TMA ) enhances the overall network performance and coverage. This , network rollout. This is where the Ericsson dual duplex TMAs can provide a cost-effective solution that


Original
PDF UL1950, ERICSSON TMA KRY 112 Ericsson tma ERICSSON dual band tma DDTMA Ericsson KRY 112 71 Ericsson TMA 1900 Tower Mounted Amplifiers ericsson ericsson BTS and antenna installation RBS 2106 ericsson kry 112
2003 - KRY 112 75 1 dual band

Abstract: Ericsson tma KRY 112 75 1 ERICSSON TMA KRY 112 TMA ericsson 1800 ericsson BTS and antenna installation Ericsson tma kry 112 75 ERICSSON dual band tma DDTMA Tower Mounted Amplifiers ericsson
Text: share network frequencies. This Ericsson dual duplex TMA eliminates any problems this could cause, by , TMA for Ericsson GSM 1800 RBSs · Full 75 MHz bandwidth ­ futureproof and logistically simple · Optimized for Ericsson 's RBS 2102 / 2202 and RBS 2106 / 2206 · Compact casing Convincing results from , antenna, this Tower Mounted Amplifier ( TMA ) enhances the overall network performance and coverage. This , network rollout. This is where the Ericsson dual duplex TMAs can provide a cost-effective solution that


Original
PDF
2002 - ERICSSON TMA KRY 112

Abstract: Ericsson tma Ericsson tma for gsm 900 Ericsson KRY 112 ERICSSON dual band tma Ericsson TMA 1900 kry 112 212 KRY 112 212 -1 KRY 112 46 TMA ericsson
Text: 54 dBm (250 W) < ­120 dBm Superimposed on the RF feeder. Dual alarm levels. 50 Ohm Ericsson TMA + , Amplifier ( TMA ) installed close to the antenna, the overall network performance and coverage is enhanced , addition the Dual Duplex TMA enables the operator to benefit from the use of a common Rx/Tx feeder. The durable TMA has lightning protection, dual amplifiers and alarm functionality. A great deal of effort has , feature of the TMAs produced by Ericsson . Key features · Optimized for RBS 2000 and GSM 1900 · Easy


Original
PDF
2002 - Ericsson tma for gsm 900

Abstract: ERICSSON TMA KRY 112 TMA ericsson 1800 Ericsson tma ericsson kry 112 ERICSSON dual band tma Tower Mounted Amplifiers ericsson KRY 112 46 ericsson BTS GSM 1800 KRY 112
Text: dBm (200 W) < ­120 dBm Superimposed on the RF feeder. Dual alarm levels. 50 Ohm Ericsson TMA + BTS , Amplifier ( TMA ) installed close to the antenna, the overall network performance and coverage is enhanced , addition the Dual Duplex TMA enables the operator to benefit from the use of a common Rx/Tx feeder. The durable TMA has lightning protection, dual amplifiers and alarm functionality. A great deal of effort has , feature of the TMAs produced by Ericsson . Key features · Optimized for RBS 2000 and GSM 1800 · Easy


Original
PDF
2002 - ERICSSON TMA KRY 112

Abstract: KRY 112 89 Ericsson tma Ericsson tma for gsm 900 kry 112 212 ERICSSON BTS product ericsson kry 112 TMA 900 KRY 112 ERICSSON dual band tma
Text: dBm Superimposed on the RF feeder. Dual alarm levels. 50 Ohm Ericsson TMA + BTS fulfils ETSI , GSM Dual Duplex Tower Mounted Amplifier for 900 MHz With a Tower Mounted Amplifier ( TMA , Duplex TMA enables the operator to benefit from the use of a common Rx/Tx feeder. The durable TMA has , keys to network operator success and is the most important feature of the TMAs produced by Ericsson , install · Excellent technical performance Technical specifications for Dual Duplex TMA for GSM 900


Original
PDF
2002 - ERICSSON TMA KRY 112

Abstract: Ericsson tma Ericsson tma for gsm 900 ERICSSON dual band tma Tower Mounted Amplifiers ericsson Ericsson TMA 1900 ERICSSON TMA KRY 112 44 ericsson kry 112 TMA 1900 KRY 112 37
Text: Reliability is one of the keys to network operator success and is the most important feature of the TMA :s produced by Ericsson . Key features · The only TMA solution for operators with wider frequency band , AB. 1.2002 Technical Specifications for Duplex TMA Fullband for GSM 1900 Ericsson , GSM Duplex Tower Mounted Amplifier Fullband for 1900 MHz With a Tower Mounted Amplifier ( TMA , business The durable TMA has lightning protection, dual amplifiers and alarm functionality. A great


Original
PDF
2003 - ERICSSON TMA KRY 112

Abstract: Ericsson tma ericsson kry 112 RBS 2106 KRY 112 488 kry 112 42 ERICSSON dual band tma RBS 2206 TMA ericsson Tower Mounted Amplifiers ericsson
Text: and logistically simple · The only approved dual duplex TMA for Ericsson RBSs · Optimized for , . Pole or wall mounting Variants dd TMA FB for GSM 800 MHz with bypass: Ericsson AB , antenna, this Tower Mounted Amplifier ( TMA ) enhances the overall network performance and coverage by reducing system noise figure and improving uplink sensitivity. Excellent reliability Ericsson dual , networks Fast deployment is crucial in a new network rollout. This is where Ericsson dual duplex TMAs can


Original
PDF
2002 - KRY 112 75 1 dual band

Abstract: ERICSSON TMA KRY 112 KRY 112 75 1 Ericsson tma TMA ericsson 1800 KRY 112 75 ericsson kry 112 75 Ericsson tma kry 112 75 KRY 112 75 dual band Ericsson KRY 112
Text: and is the most important feature of the TMAs produced by Ericsson . Key features · TMA solution , GSM Duplex Tower Mounted Amplifier Fullband for 1800 MHz With a Tower Mounted Amplifier ( TMA , business The durable TMA has lightning protection, dual amplifiers and alarm functionality. A great , · Excellent technical performance · Easy to install Technical Specifications for Duplex TMA Fullband for GSM 1800 Ericsson AB rsa.ericsson.se KRY 112 38/1 75 MHz 1710­1785 MHz 1805­1880 MHz


Original
PDF
2003 - RBS 2206

Abstract: CDU-F Ericsson Base transceiver Station Ericsson 2206 RBS 2202 ericsson RBS 2206 RBS 200 RBS ericsson maintenance dtru RBS 2206 ericsson
Text: RBS 2000 products. Ericsson 's synchronization based BSS features ensure that transceivers from , space is often a limiting factor for capacity growth. The powerful RBS 2206, included in Ericsson , 121 km · Duplexer and TMA support for all configurations · Four transmission ports supporting up to , Ericsson SE-126 25 Stockholm Sweden Telephone +46 8 719 0000 Fax +46 8 18 40 85 www.ericsson.com , 1800 / GSM 1900) With TCC activated, add 2.5 dBm to above values -111 dBm (dynamic, without TMA and


Original
PDF SE-126 RBS 2206 CDU-F Ericsson Base transceiver Station Ericsson 2206 RBS 2202 ericsson RBS 2206 RBS 200 RBS ericsson maintenance dtru RBS 2206 ericsson
2003 - RBS 2106

Abstract: RBS 2106 cabinet rbs 2106 ericsson ericsson 2106 ERICSSON RBS 2106 RBS 2106 operating weight Ericsson Base transceiver Station Ericsson tma RBS 2106 outdoor CDU-F
Text: RBS 2000 products. Ericsson 's synchronization based BSS features ensure that transceivers from , Ericsson 's grow-on-site toolbox, addresses this problem. On many sites, two or more existing cabinets can , 800, 900, 1800 and 1900 MHz · Extended Range 121 km · Duplexer and TMA support for all , temperature: Weatherproofing: Telefonaktiebolaget LM Ericsson SE-126 25 Stockholm Sweden Telephone +46 , 1800 / GSM 1900) With TCC activated, add 2.5 dBm to above values -110,5 dBm (dynamic, without TMA and


Original
PDF
Not Available

Abstract: No abstract text available
Text: TMa document h tho property of Amptionol Corporation and to deflverwd on tho enproeo condition mot R to not to bo dtooleood, rap whole or In port, for manufacture or oolo by < Corporation without , SCALE REV. C D M A — M — 0 2 0 6 — 001 | NONE 1 2 I SHEET 1 OF 4 3 4 TMa , €” Operating te m p e ra tu re range — 40” + 8 5 'C — Packing: Tape &reel according to Ericsson spec. 1 301 — RPV 403 075 Uen — Panel m ounting according to Ericsson s p e c .1 3 0 1 — PV 403


OCR Scan
PDF HK4550 HK4649 HK4723 HK4918 HKS389 HKS449 HK5502 CDMAM0206001 CDMAM0206001-2
Ericsson HLR

Abstract: RBS ericsson Ericsson MGW ericsson bsc BSC ERICSSON Ericsson tma RBS -ericsson ericsson msc et bsc ericsson msc Ericsson 3G tma
Text: reliability to all customers-even those who use Internet services. Although Ericsson CDMA Systems is a , describes Ericsson 's comprehensive, but flexible and varied five-step path for migrating present-day IS , to support a complex mix of user demands. Ericsson 's cdmaOne products and services are positioned to , introduce and roll out new applications and services more rapidly than they ever imagined. Ericsson is , Internet/ intranet User data Control Ericsson Review No. 2, 2000 Evolution of the IS-95 air


Original
PDF
UTM fuse resistor

Abstract: Ericsson tma tma cm ericsson v80b VDR Siemens Diode SCR 5v nf2 -12V RELAY SIEMENS THYRISTOR RSN 310 R 36 LSHA
Text:  ERICSSON COMPONENTS INC lb E » ■3373bfl0 DDOmab 7 ■_ ERICSSON 5 September 1989 _7? 75 , Respective Manufacturer ERICSSON COMPONENTS INC PBL 3796, PBL 3796/2 r Absolute Maximum Ratings IbE D ■3373bö0 D0014E7 =1 ■ERICSSON g 7= 75-//-/'7 Note: pin numbers refer to the 28-pln, dual-in-line , Respective Manufacturer ERICSSON COMPONENTS INC IbE D ■3373bfl0 0001426 0 ■ERICSSON ^ PBL 3796, PBL , ERICSSON COMPONENTS INC PBL 3796, PBL 3796/2 INC IbE D Parameter Ret «8 3373bö0 000142T S â


OCR Scan
PDF 3373bfl0 75-//-/J 0to70Â PBL3796J PBL3796/2J 3796/2CC UTM fuse resistor Ericsson tma tma cm ericsson v80b VDR Siemens Diode SCR 5v nf2 -12V RELAY SIEMENS THYRISTOR RSN 310 R 36 LSHA
Ericsson bts installation guide

Abstract: pbc 05 ericsson ericsson BTS and antenna installation Ericsson reference manual AXE 10 RBS ericsson 2202, fault codes Ericsson RBS 3202 hardware manual Ericsson RBS Integration Manual omt rbs ericsson ericsson bts RBS 2101 RBS 2202
Text: .169 ERA/GD/X EN/LZT 123 1210 R7B 00-12-19 © Ericsson GSM/Index 1 Table of Contents , . 37 ERA/GD/X EN/LZT 123 1210 R7B 00-12-19 © Ericsson GSM/Index 2 WAP Gateway , . 69 ERA/GD/X EN/LZT 123 1210 R7B 00-12-19 © Ericsson GSM/Index 3 GPRS Support , . 101 ERA/GD/X EN/LZT 123 1210 R7B 00-12-19 © Ericsson GSM/Index 4 Billing Gateway , . 134 ERA/GD/X EN/LZT 123 1210 R7B 00-12-19 © Ericsson GSM/Index 5 RBS 2000


Original
PDF
AXE switch ERICSSON

Abstract: Ericsson AXE 10 ERICSSON training ericsson ericsson axe
Text: 24 i i · i n focus A new Ericsson emerging T NEVER BEFORE HAS Ericsson worked so hard , AND ORGANIZATION EN YEARS AGO, ERICSSON had 70,000 employees, more than half of whom worked in a , Ericsson 's business totally. This was the unit that generated the profits that financed Ericsson 's bold new investments in mobile telephony, business systems and component manufacturing. Ericsson , networks is still an important business for Ericsson , but it is no longer the motor in the Company


Original
PDF
Aktiebolaget Telefonfabriken

Abstract: lm 1876
Text: 's telecom strategist, analyses the industry every day. His job is comparing companies such as Ericsson , Lucent, Nortel, Alcatel, Siemens and Cisco. His advice to Ericsson is: "Find good partners and good , ," David Cooperstein says. " Ericsson 's world is changing very rapidly." David is hap py to discuss , prepared to indicate various potential options for Ericsson . "Traditional telecom, as we used to know it , retailing aspects. Ericsson 's problem will be to differentiate all of its products. If customers cannot see


Original
PDF
2000 - Ericsson GSM system

Abstract: ericsson r520 MC218 R320 R520 technical considerations by ericsson ERICSSON training Ericsson Communications US Marketing Services
Text: Invitation to participate in Ericsson Developers' Zone Alliance Program November 30, 2000 Contents - Introduction Ericsson Developers' Zone Alliance Program (EDZ-AP) Components and services , Ericsson 's forecasts indicate that there will be one billion users of mobile telephony and the Mobile , spectrum of new mobile solutions, Ericsson announced the Ericsson Developers' Zone Alliance Program in , a worldwide market, based on the global presence and leadership of Ericsson in wireless technology


Original
PDF 24-hours Ericsson GSM system ericsson r520 MC218 R320 R520 technical considerations by ericsson ERICSSON training Ericsson Communications US Marketing Services
2010 - ericsson power supply

Abstract: No abstract text available
Text: E EZIWSON Approved Prepared (also subject responsible if other) No. Ericsson Internal , Uen Specification 2011-12-21 2011-08-11 EN/LZT 146 401 R3B December 2011 © Ericsson AB Input , Ericsson Internal PRODUCT SPECIFICATION No. Checked Date 2 (4) Prepared (also subject responsible if , © Ericsson AB Rev Reference 2 BMR 45 1 Digital SEC/D (Julia You) PoL Regulators Input 4.5-14 V , n7 Exemptions in the RoHS directive utilized in Ericsson Power Modules products include: Lead in high


Original
PDF 1/1301-BMR 451Technical Uen401 ericsson power supply
2006 - LA 4303

Abstract: ci 4303 ericsson BMR CI LA 4303 IEC 60068-2-54
Text: Limited Internal Ericsson Internal TABLE OF SPECIFICATION PRODUCT CONTENTS E Prepared , © Ericsson Power Modules AB Key Features · Industry standard Quarter-brick 57.9 x 36.8 x 10.9mm (2.28 x , . 13 . 14 Ericsson Internal PRODUCT , Rev Reference 2 EN/LZT 146 342 R1A February 2006 A © Ericsson Power Modules AB , different results. Ericsson Power Modules currently uses two different methods, Ericsson failure rate data


Original
PDF 4303NF 52-EN/LZT 1/1301-BMR6414303/311 48Vin MIL-STD-202G LA 4303 ci 4303 ericsson BMR CI LA 4303 IEC 60068-2-54
2008 - Ericsson GM 12

Abstract: 4201B ICT PRC P7 PKB 4204B
Text: E Approved Approved Ericsson Internal Limited Internal PRODUCT SPECIFICATION TABLE OF CONTENTS , /UL 60950 · More than 1.3 million hours MTBF MICTOJO B C © Ericsson Power Modules AB , . 19 . 20 E Approved Ericsson , MICTOJO B © Ericsson Power Modules AB Compatibility with RoHS requirements The products are , utilized in Ericsson Power Modules products include: Lead in high melting temperature type solder (used to


Original
PDF 1/1301-BMR658 52-EN/LZT 4000B Ericsson GM 12 4201B ICT PRC P7 PKB 4204B
2010 - ericsson BMR 610 49

Abstract: ericsson BMR 610 ericsson 800 filter ericsson BMR ericsson BMR 610 45 BMR 610 49/08 ericsson BMR 610 26
Text: E Approved Ericsson Internal PRODUCT TABLE OF CONTENTS SPECIFICATION No. Checked Date 1 (1 , Uen Specification Technical 2010-09-27 2010-09-21 EN/LZT 146 433 R1A September 2010 © Ericsson AB , Ericsson Internal PRODUCT SPECIFICATION No. Checked Date 2 (4) Prepared (also subject responsible if other) Technical Specification EN/LZT 146 433 R1A September 2010 © Ericsson AB Rev Reference 2 , Ericsson Power Modules products include: Lead in high melting temperature type solder (used to solder the


Original
PDF 52-EN/LZT 48Vin ericsson BMR 610 49 ericsson BMR 610 ericsson 800 filter ericsson BMR ericsson BMR 610 45 BMR 610 49/08 ericsson BMR 610 26
ERICSSON training

Abstract: MC218 Nokia Mobile Technical Reference
Text: Ericsson Developers' Zone Alliance Program for Smartphones and Communicators White Paper , opportunities for 3rd party applications. In the Ericsson Developers' Zone Alliance Program for Smartphones and Communicators, we will focus on supporting 3rd party development for Ericsson 's highend, EPOC , the PC from a stand alone device to a networked tool). Ericsson takes the lead! As the wireless industry leader, Ericsson has developed datacapable networks that use open and existing standards


Original
PDF
2005 - Ericsson Power Modules

Abstract: 8218T
Text: systems manufacturers, the PMM responds to world-class specifications. Ericsson Power Modules is an ISO , 1.51 :88999$/ 999 2 © Ericsson Power Modules, September 2005 Mechanical Information - surface mount 1.54 :88999$/ 999 3 © Ericsson Power Modules, September 2005 Product Program , . Information provided is believed to be accurate and reliable. Ericsson Power Modules makes no commitment to , information contained herein, without notice. Ericsson Power Modules AB SE-126 25 Stockholm, Sweden


Original
PDF 8218T SE-126 Ericsson Power Modules 8218T
2007 - ICT PRC A4

Abstract: narrow band module mtbf Ericsson Power Modules
Text: Ericsson Internal Limited Internal PRODUCT SPECIFICATION TABLE OF CONTENTS E Prepared , Reference EN/LZT 146 382 R1B August 2009 A © Ericsson Power Modules AB Key Features · Industry , Meets requirements in hightemperature lead-free soldering processes. Ericsson Internal PRODUCT , August 2009 A © Ericsson Power Modules AB made of Brass) General Information Ordering , different results. Ericsson Power Modules currently uses Telcordia SR332. Predicted MTBF for the series is


Original
PDF 1/1301-BMR636 00152-EN/LZT146 01/A4 IEC500 ICT PRC A4 narrow band module mtbf Ericsson Power Modules
2010 - MA 8910 switching regulator

Abstract: BMR45 CDA-102
Text: E EZIWSON ESLUOAN Approved Ericsson Internal PRODUCT TABLE OF CONTENTS SPECIFICATION No , © Ericsson AB Rev Reference BMR 450 Digital SEC/D (Julia You) PoL Regulators Key Features Input , Ericsson Internal PRODUCT SPECIFICATION No. Checked Date 2 (4) Prepared (also subject responsible if , © Ericsson AB Rev Reference 2 BMR 450 Digital SEC/D (Julia You) PoL Regulators Input 4.5-14 V , utilized in Ericsson Power Modules products include: Lead in high melting temperature type solder (used to


Original
PDF 1/1301-BMR 52-EN/LZT MA 8910 switching regulator BMR45 CDA-102
Supplyframe Tracking Pixel