The Datasheet Archive

Ericsson KRY 112 71 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2003 - ERICSSON TMA KRY 112

Abstract: Ericsson tma ERICSSON dual band tma DDTMA Ericsson KRY 112 71 Ericsson TMA 1900 Tower Mounted Amplifiers ericsson ericsson BTS and antenna installation RBS 2106 ericsson kry 112
Text: environments. Technical Specifications for Dual Duplex TMA Fullband for GSM 1900 KRY 112 71 Electrical , ddTMA 1900 FB with LNA by-pass: Available ordering guides: KRY 112 71 /2 EN/LZT 123 7019 and EN/LZT , share network frequencies. This Ericsson dual duplex TMA eliminates any problems this could cause, by , network rollout. This is where the Ericsson dual duplex TMAs can provide a cost-effective solution that , TMA for Ericsson GSM 1900 MHz RBSs. · Full 60 MHz bandwidth ­ futureproof and logistically simple


Original
PDF UL1950, ERICSSON TMA KRY 112 Ericsson tma ERICSSON dual band tma DDTMA Ericsson KRY 112 71 Ericsson TMA 1900 Tower Mounted Amplifiers ericsson ericsson BTS and antenna installation RBS 2106 ericsson kry 112
2002 - ERICSSON TMA KRY 112

Abstract: KRY 112 89 Ericsson tma Ericsson tma for gsm 900 kry 112 212 ERICSSON BTS product ericsson kry 112 TMA 900 KRY 112 ERICSSON dual band tma
Text: Product number KRY 112 14 Electrical specifications Bandwidth: Receiver pass band: Transmitting pass , by-pass: Available ordering guides: KRY 112 14/10, /11 KRY 112 14/12, /13 EN/LZT 123 7475 and EN/LZT , keys to network operator success and is the most important feature of the TMAs produced by Ericsson , dBm Superimposed on the RF feeder. Dual alarm levels. 50 Ohm Ericsson TMA + BTS fulfils ETSI , frequency planning. Ericsson AB www.ericsson.com AE/LZT 123 4056 R11 © Ericsson AB 2002 The


Original
PDF
2002 - ERICSSON TMA KRY 112

Abstract: Ericsson tma Ericsson tma for gsm 900 Ericsson KRY 112 ERICSSON dual band tma Ericsson TMA 1900 kry 112 212 KRY 112 212 -1 KRY 112 46 TMA ericsson
Text: 1900 MHz Sub-bands KRY 112 15 Electrical specifications Bandwidth: Receiver pass band , : Versions with LNA by-pass: Available ordering guides: KRY 112 15/1, /2, /3 KRY 112 15/4, /5, /6 EN/LZT 123 7019 and EN/LZT 123 7020 */ IM measured at the Antenna port Ericsson AB , feature of the TMAs produced by Ericsson . Key features · Optimized for RBS 2000 and GSM 1900 · Easy , 54 dBm (250 W) < ­120 dBm Superimposed on the RF feeder. Dual alarm levels. 50 Ohm Ericsson TMA +


Original
PDF
2002 - Ericsson tma for gsm 900

Abstract: ERICSSON TMA KRY 112 TMA ericsson 1800 Ericsson tma ericsson kry 112 ERICSSON dual band tma Tower Mounted Amplifiers ericsson KRY 112 46 ericsson BTS GSM 1800 KRY 112
Text: GSM 1800 Sub-bands KRY 112 20 Electrical specifications Bandwidth: Receiver pass band , : Versions with LNA by-pass: Available ordering guides: KRY 112 20/1, /2, /3 KRY 112 20/5, /6, /7, /11 EN/LZT 123 7018 and EN/LZT 123 7020 */ IM measured at the Antenna port Ericsson AB , feature of the TMAs produced by Ericsson . Key features · Optimized for RBS 2000 and GSM 1800 · Easy , dBm (200 W) < ­120 dBm Superimposed on the RF feeder. Dual alarm levels. 50 Ohm Ericsson TMA + BTS


Original
PDF
2003 - KRY 112 75 1 dual band

Abstract: Ericsson tma KRY 112 75 1 ERICSSON TMA KRY 112 TMA ericsson 1800 ericsson BTS and antenna installation Ericsson tma kry 112 75 ERICSSON dual band tma DDTMA Tower Mounted Amplifiers ericsson
Text: . Technical Specifications for Dual Duplex TMA Fullband for GSM 1800 KRY 112 61 Electrical specifications , : Available ordering guides: KRY 112 61/2 EN/LZT 123 7018 and EN/LZT 123 7020 */ Referring to IM5 and , share network frequencies. This Ericsson dual duplex TMA eliminates any problems this could cause, by , network rollout. This is where the Ericsson dual duplex TMAs can provide a cost-effective solution that , TMA for Ericsson GSM 1800 RBSs · Full 75 MHz bandwidth ­ futureproof and logistically simple ·


Original
PDF
2003 - ERICSSON TMA KRY 112

Abstract: Ericsson tma ericsson kry 112 RBS 2106 KRY 112 488 kry 112 42 ERICSSON dual band tma RBS 2206 TMA ericsson Tower Mounted Amplifiers ericsson
Text: rsa.ericsson.com KRY 112 81/2 AE/LZT 123 7186 R3 © Ericsson AB 2003 The production and the materials are , : Dimension (H x W x D): Volume: Weight: RF connector: DC/Alarm: Mounting: KRY 112 81 25 MHz 824­849 , reducing system noise figure and improving uplink sensitivity. Excellent reliability Ericsson dual , networks Fast deployment is crucial in a new network rollout. This is where Ericsson dual duplex TMAs can , only 2 MHz away from the receive band which potentially can cause interference problems. Ericsson dd


Original
PDF
2002 - ERICSSON TMA KRY 112

Abstract: Ericsson tma Ericsson tma for gsm 900 ERICSSON dual band tma Tower Mounted Amplifiers ericsson Ericsson TMA 1900 ERICSSON TMA KRY 112 44 ericsson kry 112 TMA 1900 KRY 112 37
Text: : Ericsson Radio Access AB rsa.ericsson.se KRY 112 37 60 MHz 1850­1910 MHz 1930­1990 MHz 12 ± 1dB 13 , produced by Ericsson . Key features · The only TMA solution for operators with wider frequency band , 5847 R1 © Ericsson Radio Access AB 2002 The production and the materials are environmentally , AB. 1.2002 Technical Specifications for Duplex TMA Fullband for GSM 1900 Ericsson


Original
PDF
2002 - KRY 112 75 1 dual band

Abstract: ERICSSON TMA KRY 112 KRY 112 75 1 Ericsson tma TMA ericsson 1800 KRY 112 75 ericsson kry 112 75 Ericsson tma kry 112 75 KRY 112 75 dual band Ericsson KRY 112
Text: Fullband for GSM 1800 Ericsson AB rsa.ericsson.se KRY 112 38/1 75 MHz 1710­1785 MHz 1805­1880 MHz , and is the most important feature of the TMAs produced by Ericsson . Key features · TMA solution , 123 5629 R3 © Ericsson AB 2002 The production and the materials are environmentally approved. All , : Mounting: Ericsson


Original
PDF
Not Available

Abstract: No abstract text available
Text: ERICSSON ^ PTE 10041* 12 Watts, 2.0 GHz LDMOS Field Effect Transistor Description The 10041 is , or obtain additional information from your Ericsson Sales Representative. 4-43 G O LD °C , Voltage Drain Current Gate Threshold Voltage Forward Transconductance (100% Tested) ERICSSON $ , ) G O L D 4-44 ERICSSON ^ Output Power vs. Supply Voltage PTE 10041 3rd Order IMD vs , LDMOS PTE 10041 Typical Scattering Parameters (V Ds ERICSSON ^ = 26 V, Ijjq = 500 mA) S11


OCR Scan
PDF
3g call flow ericsson

Abstract: MD110 m35000 Matec model 60 ericsson MD110 PBX ericsson 3G thailand FAS109 FAS106 tesla 516 Ericsson microwave commissioning
Text: rising stock prices of it-companies, and Internetrelated companies in particular. Ericsson started the , were concluded in 1999. Among the most important were: · In March, Ericsson and Qualcomm struck a , ) wcdma standardization. Ericsson and Qualcomm agreed on intellectual property rights and thereby eliminated patent litigation issues. Ericsson also acquired Qualcomm's infrastructure division and is now , , Ericsson acquired two U.S.-based companies specialized in Internet access routers, Torrent Network


Original
PDF
LM 9806

Abstract: 9806 Q2-99 Q4-99 internet share scania BT 342 project
Text: Report 1999 January 28, 2000 Ericsson 1999 report · Best quarter ever: orders, sales , SEK 6.17 (6.66). Considerable strategic progress has been made during the year giving Ericsson a forefront position when the market for mobile Internet now starts to take off. 2 Ericsson is the , was led by a 39 percent increase in the US, again Ericsson 's single largest market. Europe continued , China and for Consumer Products. Ericsson increased net sales by 17 percent to SEK 215.4 b. for 1999


Original
PDF Q4-99 Q3-99 Q2-99 Q1-99 LM 9806 9806 Q2-99 Q4-99 internet share scania BT 342 project
2012 - BMR451

Abstract: AN306 BMR464
Text: Application Note 302 Ericsson Power Modules PMBus command set - 3E Point of load regulators Introduction Ericsson 's 3E Point-Of-Load (POL) regulators are designed with state-of-the-art digital , , Ericsson 's 3E POL regulators feature the Group Command Bus (GCB). The GCB is an inter-device communication , . Application Note 302 2 EN/LZT 146 259 R2A © Ericsson Power Modules, March 2012 Contents Introduction2 Forum Websites4 Notes On Using The PMBus Interface With Ericsson 3E POL Regulators 6 Power On


Original
PDF SE-164 BMR451 AN306 BMR464
2003 - po473

Abstract: No abstract text available
Text: 7 8 9 EN/LZT 146 041 R1A © Ericsson Power Modules AB, December 2003 Safety , 4117A SI Datasheet EN/LZT 146 041 R1A © Ericsson Power Modules AB, December 2003 Transient input , Power dissipation W PKF 4117A SI Datasheet EN/LZT 146 041 R1A © Ericsson Power Modules AB , Dynamic load response (typ) @ +25°C 36 7.1 7.0 6.9 6.8 6.7 -40 The output voltage deviation , Temperature coefficient [V] 38 7.1 3 78 Output characteristic (typ) [V] 18 84


Original
PDF 60VDC SE-141 po473
2006 - Not Available

Abstract: No abstract text available
Text: 7 8 9 2 PKF 4117A SI Datasheet EN/LZT 146 041 R1B © Ericsson Power Modules AB, March , © Ericsson Power Modules AB, March 2006 3 Output TC = ­30.+95 °C, VI = 36.75 V and pin 8 connected , max Unit 4 PKF 4117A SI Datasheet EN/LZT 146 041 R1B © Ericsson Power Modules AB, March , 0.6 1.2 1.8 2.4 3.0 [A] Load Current 36 V 53 V 75 V Effiency 12 9 6 3 0 -50 7.1 7.0 6.9 6.8 , = 0.55-1.65-0.55A 38 Output voltage 7.2 7.1 7.0 6.9 6.8 6.7 -40 -20 0 20 40 60 80 100 [°C] Turn-on


Original
PDF 60VDC SE-126
9906A

Abstract: Ericsson GSM system 9903A 9912a
Text: Interim Report Three months ended March 31, 2000 April 28, 2000 Ericsson raises forecast after , percent 67 42 366 339 216 SUMMARY Ericsson today reported income before tax of SEK 6.1 b. for the , 045 m. from divestiture of part of Ericsson 's stake in Saraïde. Orders increased by 67 percent and , quarter shows Ericsson 's clear lead in mobile Internet including 3G, which is beginning to take off. I am , Kurt Hellström, president of Ericsson . "We have captured more than 50 percent of the strategically


Original
PDF
2005 - 4128B

Abstract: No abstract text available
Text: Fax: +46-8-568-69599 Italy, Spain (Mediterranean) Ericsson Power Modules AB Via Cadorna 71 20090 , information see PKF general datasheet EN/LZT 146 089 R1A © Ericsson Power Modules AB, March 2005 2 , R1A © Ericsson Power Modules AB, March 2005 3 Output TC = ­30.+95 °C, VI = 36.75 V, IO1 = , dissipation Operating frequency 4 EN/LZT 146 089 R1A © Ericsson Power Modules AB, March 2005 Typical , © Ericsson Power Modules AB, March 2005 5 Radiated EMS (Electro-Magnetic Fields) Radiated EMS is


Original
PDF 4128B 60VDC
2007 - Not Available

Abstract: No abstract text available
Text: : +46-8-568-69599 Italy, Spain (Mediterranean) Ericsson Power Modules AB Via Cadorna 71 20090 Vimodrone (MI , quality levels. Ericsson Power Modules is an ISO 9001/14001 certified supplier. E Datasheet Product Program VI VO/IO max Output 1 1.2 V/80 A 1.5 V/80 A 1.8 V/ 71 A 48/60 2.5 V/55 A 3.3 V/50 A 5.0 V , /LZT 146 035 R7A © Ericsson Power Modules, February 2007 Mechanical Information PKM 4000C Datasheet EN/LZT 146 035 R7A © Ericsson Power Modules, February 2007 Absolute Maximum Ratings


Original
PDF 4000C 4118HC 4118GC
2004 - sony ericsson Camera

Abstract: ericsson single line module 900 GSM Ericsson base station receiver unlock mobile phones codes ericsson alarm list
Text: © Print only for private use. Sony Ericsson GSM 900/1800/1900 This user guide is published by Sony Ericsson Mobile Communications AB, without any warranty. Improvements and changes to this user guide , equipment, may be made by Sony Ericsson Mobile Communications AB at any time and without notice. Such , Ericsson Mobile Communications AB, 2004 Publication number: AE/LZT 108 7308 R1A Please note: Some of the , Emergency Number 112 . Please contact your service provider if you are in doubt as to whether you can use


Original
PDF
2004 - Not Available

Abstract: No abstract text available
Text: requirements of systems manufacturers, the PKM-NG responds to world-class specifications. Ericsson Power , /LZT 146 085 R1A © Ericsson Power Modules, December 2004 Absolute Maximum Ratings Characteristics , © Ericsson Power Modules, December 2004 Product Qualification Specification (Pending) Characteristics , © Ericsson Power Modules, December 2004 Safety Specification General information. Ericsson Power , ", but all of these standards are based on IEC/EN/UL60950 with regards to safety. Ericsson Power Modules


Original
PDF Deliv1-972-583-7839
2005 - Not Available

Abstract: No abstract text available
Text: quality levels. Ericsson Power Modules is an ISO 9001/14001 certified supplier. E Datasheet Product Program VI VO/IO max Output 1 1.2 V/80 A 1.5 V/80 A 1.8 V/ 71 A 48/60 2.5 V/55 A 3.3 V/50 A 5.0 V , available but will decrease the maximum available output current. Ericsson power modules do not recommend , material to the board. PKM 4000C Datasheet 2 EN/LZT 146 035 R3D © Ericsson Power Modules, June 2005 Mechanical Information PKM 4000C Datasheet 3 EN/LZT 146 035 R3D © Ericsson Power


Original
PDF 4000C 4918LC 4118HC 4118GC 4119C 4110C 4211C
2005 - Not Available

Abstract: No abstract text available
Text: and meet world-class quality levels. Ericsson Power Modules is an ISO 9001/14001 certified supplier. E Datasheet Product Program VI VO/IO max Output 1 1.2 V/80 A 1.5 V/80 A 1.8 V/ 71 A 48/60 , output current. Ericsson Power Modules do not recommend that each pin should conduct more than 40A due to , Datasheet 2 EN/LZT 146 035 R3A © Ericsson Power Modules, February 2005 Mechanical Drawing PKM 4000C Datasheet 3 EN/LZT 146 035 R3A © Ericsson Power Modules, February 2005 Absolute Maximum


Original
PDF 4000C 4918LC 4118HC 4118GC 4119C
1999 - PGR 50

Abstract: No abstract text available
Text: A © Ericsson Components AB, January, 1999 71 Ericsson , . Electrical Interface Output signals Loss of signal Quality Assurance Ericsson Components commitment to , Ericsson internal quality specifications, and supplied with final test data. Connector Options FC/PC SC , , active high output, less than 2 dBm of hysteresis Ericsson Components Phone: +46 (8) 757 4402 Fax: +46 , license is granted by implication or otherwise under any patent or patent rights of Ericsson Components AB


Original
PDF STM-16 OC-48 GR-253CORE) 1522-PGR PGR 50
2006 - Not Available

Abstract: No abstract text available
Text: Fax: +46-8-568-69599 Italy, Spain (Mediterranean) Ericsson Power Modules AB Via Cadorna 71 20090 , quality levels. Ericsson Power Modules is an ISO 9001/14001 certified supplier. E Datasheet Product Program VI VO/IO max Output 1 1.2 V/80 A 1.5 V/80 A 1.8 V/ 71 A 48/60 2.5 V/55 A 3.3 V/50 A 5.0 V , . Ericsson power modules do not recommend that each pin should conduct more than 40A due to power dissipation , © Ericsson Power Modules, May 2006 Mechanical Information PKM 4000C Datasheet 3 EN/LZT 146 035


Original
PDF 4000C 4918LC 4118HC 4118GC 4110C
2005 - Not Available

Abstract: No abstract text available
Text: quality levels. Ericsson Power Modules is an ISO 9001/14001 certified supplier. E Datasheet Product Program VI VO/IO max Output 1 1.2 V/80 A 1.5 V/80 A 1.8 V/ 71 A 48/60 2.5 V/55 A 3.3 V/50 A 5.0 V , available but will decrease the maximum available output current. Ericsson power modules do not recommend , material to the board. PKM 4000C Datasheet 2 EN/LZT 146 035 R3C © Ericsson Power Modules, May 2005 Mechanical Information PKM 4000C Datasheet 3 EN/LZT 146 035 R3C © Ericsson Power Modules, May 2005


Original
PDF 4000C 4918LC 4118HC 4118GC 4119C 4110C 4211C
2001 - GSM vco

Abstract: vco gsm PBL40307 IC vco 1800 mhz 1 928 498 167 H 498 1 928 403 PBL403 GSM900 pbl 40307
Text: 1933 MHz RF output GSM 15.2 16.7 18.2 dBm RF output DCS 11.2 12.7 14.2 dBm RF output PCS 11.2 12.7 14.2 dBm Vcont sensitivity GSM Vcont , 64 R1A © Ericsson Microelectronics, February 2001 PBL 403 07 Pin Configuration Terminal 1 2 3 , © Ericsson Microelectronics, February 2001 3 Evaluation Board continued VCC + C1 LB 3.75V , . Evaluation Board layout. Ericsson Microelectronics SE-164 81 Kista, Sweden Telephone: +46 8 757 50 00


Original
PDF GSM900 13dBm/ 13dBm) 100pF SE-164 GSM vco vco gsm PBL40307 IC vco 1800 mhz 1 928 498 167 H 498 1 928 403 PBL403 pbl 40307
Supplyframe Tracking Pixel