The Datasheet Archive

EN61131-2 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2011 - audio plug 3.5mm surface mounted

Abstract: HG9Z-XU1 RS232 3.5MM HG9Z-XT09 1347H RCA 467 HG9Z-XCE21 HG4G-CJT22MF HG9Z-XT09V HG3G-8JT22MF
Text: terminals: ±1 kV, Communication line: ±0.5 kV (IEC/ EN61131-2 : 2007) ESD-3 (RH-1), Level 3 (Contact ±6 kV, air ±8 kV) (IEC/ EN61131-2 : 2007) Free from corrosive gases IP66 (IEC 60529) (front part when mounted , transient/burst test, Power terminals: ± 2 kV, Communication line: ±1 kV (IEC/ EN61131-2 : 2007) ESD-3 (RH-1), Level 3 (Contact ±6 kV, air ±8 kV) (IEC/ EN61131-2 : 2007) Free from corrosive gases IP66 (IEC 60529 , Mounting User Memory Display Resolution Backlight Backlight Life *1 Brightness * 2 Brightness Adjustment SD


Original
PDF 800cd/m2 800-262-IDEC audio plug 3.5mm surface mounted HG9Z-XU1 RS232 3.5MM HG9Z-XT09 1347H RCA 467 HG9Z-XCE21 HG4G-CJT22MF HG9Z-XT09V HG3G-8JT22MF
2008 - 1440-SCDB9FXM2

Abstract: 1440-ACNR EN60079-15 vibration alarm accelerometer 1440-DYN02-01RJ iepe circuit iepe Accelerometers datasheet EN61131-2 iepe EN60079-1
Text: -1 (Industrial), and EN61131-2 (Clause 8, Zones A&B) UL - UL 508 ULH ­ UL 1604 Class I Div 2 , Groups A,B,C,D , LVD - EN61131-2 (Clause 11) C-Tick (Australia) - AS/NZS CISPR11 (Group 1, Class A) ATEX ­ EN60079 , Measurement Module is an intelligent 2 -channel general-purpose monitor that supports measurements of , -DYN02-01RJ SPECIFICATIONS Inputs Inputs · 2 Dynamic Channel Inputs o Eddy Current Transducer signals o Accelerometer , Filter Applied to integrated acceleration measurements o -6 dB Corner: 2 kHz o Roll Off: -12 dB/octave


Original
PDF monitorin250mA 210mA 1440-DYN02-01RJ 1440-ACNR 1440-TBS-J 1440-SCDB9FXM2 1440-SCDB9FXM2 1440-ACNR EN60079-15 vibration alarm accelerometer 1440-DYN02-01RJ iepe circuit iepe Accelerometers datasheet EN61131-2 iepe EN60079-1
ALE2405R

Abstract: AWG12 AWG16 EN61131-2 ale240 transformateur 9v EN 61558-2-6 61558-2-6
Text: Section maxi du fils : 2 ,5mm² (AWG12). · Tension de sortie : 24V continu (suivant EN61131-2 ) · , Ausgangsspannung : 24 V Gleichspannung (gemäß EN61131-2 ) · Welligkeit : 5% · Haltezeit : 20 ms bei Nennwerten von , : Lightweight and small sized. 5 1 4 6 . 2 1 5 5 1 9 1 2 5 3 ,1 K g 9 0 1 4 5 1 4 0 , pour fils : 2 ,5mm² (AWG12). · Indice de protection : IP 30. · Sécurité : Classe I Conforme à la , 0A 28,3V 0% 1A 26,9V 1% 2A 26,0V 2 % 3A 25,3V 3% 4A 24,7V 4% 5A 24,0V 5% Fixation


Original
PDF ALE2405R 230/400V 24Vfiltred ALE2405R AWG12 AWG16 EN61131-2 ale240 transformateur 9v EN 61558-2-6 61558-2-6
RSLOGIX 5000

Abstract: 1440-DYN02-01RJ ControlLogix RSLOGIX RSLogix 5000 software rockwell RSLOGIX 5000 CONTROLLOGIX WIRING RSLOGIX 500 EN61131-2 CNET-IN002
Text: · EMC - EN61000-6-2, EN61000-6-4, EN61326-1 (Industrial), and EN61131-2 (Clause 8, Zones A&B) · UL - UL 508 · ULH ­ UL 1604 Class I Div 2 , Groups A,B,C,D · CUL - CSA C22. 2 No 142-M1987 · CULH - CSA C22. 2 No. 213-M1987 Class I Division 2 , Groups A,B,C and D · LVD - EN61131-2 (Clause 11) · , 900VAC for 60 seconds between XMBus to CNet and CNet to user power · Field Power o Required: Class 2 , · Wiring Category 1. on power ports 2 . on communications ports · Screw Torque = 7 pound-inches


Original
PDF 1440-ACNR CNET-IN002A ICM-TD001A-EN-E 1440-ACNR RSLOGIX 5000 1440-DYN02-01RJ ControlLogix RSLOGIX RSLogix 5000 software rockwell RSLOGIX 5000 CONTROLLOGIX WIRING RSLOGIX 500 EN61131-2 CNET-IN002
2008 - EN61131-2

Abstract: EN60079-15 1440-DYN02-01RJ EN6007915 EN61326-1 EN61000-6-4 EN61000-6-2 en61326 EN60079-0 EN-61326-1
Text: o EMC - EN61000-6-2, EN61000-6-4, EN61326-1 (Industrial), and EN61131-2 (Clause 8, Zones A&B) UL - UL 508 ULH ­ UL 1604 Class I Div 2 , Groups A,B,C,D CUL - CSA C22. 2 No 142-M1987 CULH - CSA C22. 2 No. 213-M1987 Class I Division 2 , Groups A,B,C and D LVD - EN61131-2 (Clause 11) C-Tick , machinery. The 1440-DYN02-01RJ Dynamic Measurement Module is an intelligent 2 -channel general-purpose


Original
PDF 1440-TBS-J 1440-DYN02-01RJ 1440-DYN02-01RJ ICM-TD002A-EN-E 1440-TBS-J EN61131-2 EN60079-15 EN6007915 EN61326-1 EN61000-6-4 EN61000-6-2 en61326 EN60079-0 EN-61326-1
2011 - M136

Abstract: 4AV2102-2EB00-0A IEC 61558-2-6 iron EI core EN61131-2 61558-2-6 4AV2 61558-2-6 siemens
Text: :MOUNTING RAILS; EN 61558-2-6, EN61131-2 >SAFETY ISOLATING TRANSFORMER< General technical details , ; USEC(V DC):24; ISEC(A DC):1/1, 2 (60/40 CEL); F(HZ):50.60; VECTOR GR./SHIELD WNG.:II0 /0 , 230 · _ 2 / rated value V 115 Hz 50 Electrical input frequency · minimum , _ 2 / rated value A 0.3 Input voltage Input current Design of the electrical connection , Approval other ROSTEST Manufacturer 4AV2102-2EB00-0A Page 2 / 3 other 06/06/2011


Original
PDF 4AV2102-2EB00-0A EN61131-2 com/WW/view/en/4AV2102-2EB00-0A/all M136 4AV2102-2EB00-0A IEC 61558-2-6 iron EI core EN61131-2 61558-2-6 4AV2 61558-2-6 siemens
2009 - EP2316-0008

Abstract: EL1512 DK9222-0909-0008 EL1114 EP2338 EP1008 KL1304 Beckhoff EL1104 KL1408 EN61131-2
Text: be found at www.beckhoff.com/ EN61131-2. 2 -wire sensor 3-wire sensor L+ L+ L­ L , EN61131-2 compatible products www.beckhoff.com/ EN61131-2 ­ The modular fieldbus system for automation , I/O Keywords 2 -wire sensors 3-wire sensors EN 61131-2 digital input input charakteristics , -0909-0008 I/O Systems Beckhoff I/O systems: Digital inputs for 2 -wire and 3-wire sensors according to EN , Difference between 2 -wire and 3-wire sensors There is a basic conflict of goals in the recording of digital


Original
PDF DK9222-0909-0008 EP2316-0008 EL1512 DK9222-0909-0008 EL1114 EP2338 EP1008 KL1304 Beckhoff EL1104 KL1408 EN61131-2
2000 - Not Available

Abstract: No abstract text available
Text: device EMI EN50081- 2 :1993 EMS EN61131-2 :1995 Electrical safety EN61131-2 : 1995 NTH25 , ±30° Display color NTH25C: Up: 30°; Down: 30°; Left/right: ±50° NTH25: Black, white ( 2 colors) NTH25C , operation at the touch panel Life expectancy (See Note 2 .) 10,000 minimum Backlight (white cold , period. 2 . Time taken for brightness to reduce to half at normal temperature and humidity. 2 NTH25 , Wide, high, 2 x 2 , 4 x 4, 8 x 8 Character display attributes Standard, flash, inverse flash


Original
PDF NTH25 NTH25 NTH25C-ST141B NT-AL001, RS-232C RS-422A 1-800-55-OMRON P10FAD1 4/00/10M
Not Available

Abstract: No abstract text available
Text: REC2R60D30GKE REC2R60A30GKE * According to EN61131-2 Specifications are subject to change without notice , voltage REC.D. 24 VDC 15-32 VDC (according to EN61131-2 ) 10 mA 15 VDC 32 VDC 1 VDC 5 ms 15 , Key REC 2 R 48 A 2 0 G K E REC2R is a 3-phase electronic motor reversing relay. L1-T1 and L3-T3 , : 2 poles R: Reversing 48: 48-530 VAC D: 24 VDC, -15%, + 20% 2 : 2.2kW 3: 3.0kW 0 , Poles 48-530 VAC 2 48-600 VAC 2 Control voltage 24VDC 90-253VAC 24VDC 90-253VAC


Original
PDF 3RU11 TA25DU-8 3RU1126-1FB0
2011 - 4AV3200-2EB00-0A

Abstract: EN61131-2 IP-00 IEC 61558-2-6 siemens GR 60 48 V
Text: ; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):4, 2 ; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-6, EN61131-2 >UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER< General technical , / rated value V 420 · _ 2 / rated value V 400 · _3 / rated value V 380 , information: 4AV3200-2EB00-0A Page 2 / 3 06/06/2011 subject to modifications © Copyright Siemens AG


Original
PDF 4AV3200-2EB00-0A EN61131-2 com/WW/view/en/4AV3200-2EB00-0A/all 4AV3200-2EB00-0A EN61131-2 IP-00 IEC 61558-2-6 siemens GR 60 48 V
Not Available

Abstract: No abstract text available
Text: IEC 600 68-2-6 ( EN61131-2 ): Environmental resistance: 50 g at 11 ms amplitude, half sinusoidal 5


Original
PDF EN61131-2) D-88276
2009 - DK9221-0909-0008

Abstract: KL1408 EN61131-2 Beckhoff EL1104 EP1008 EP2316 KL1402 KL1304 16-Kanal
Text: /O-Systeme ­ EN61131-2-kompatible Produkte www.beckhoff.de/ EN61131-2 ­ Der universelle Baustein der , Übersicht der EN611312-Produkte von Beckhoff, die auch unter www.beckhoff.de/ EN61131-2 zu finden ist, werden vorgestellt. 2 -Leitersensor 3-Leitersensor L+ L+ L­ L­ Abb. 1 links , I/O Keywords 2 -Leitersensoren 3-Leitersensoren EN 61131-2 Digitaler Eingang , -0909-0008 I/O-Systeme Beckhoff-I/O-Systeme: Digitale Eingänge für 2 - und 3-Leitersensoren nach EN 61131-2


Original
PDF DK9221-0909-0008 EN611312 DK9221-0909-0008 KL1408 EN61131-2 Beckhoff EL1104 EP1008 EP2316 KL1402 KL1304 16-Kanal
EN61326-1

Abstract: EN61000-6-2 EN-61326-1 EN50178 EN61000-6-4 EN61010 EN61131-2 en61326 EN61010-1 UL508
Text: Web Datalogger Unit EMC directives EN61000-6-4/EN61000-6-2 Low-voltage directives EN61131-2


Original
PDF EN61326-1 EN61000-6-4/EN61000-6-2 EN61010-1 EN300 328/EN50371/EN301 489-17/EN60950-1 EN61131-2/EN50178 EN61326-1 EN61000-6-2 EN-61326-1 EN50178 EN61000-6-4 EN61010 EN61131-2 en61326 EN61010-1 UL508
2012 - D-32457

Abstract: No abstract text available
Text: , Di (digital inputs according to EN61131-2 ) Voltage UHmax UHmin ULmin ULmax Outputs Q1,Q2 , Document : 6075988028_en.doc / Last update : 2 / 0221-12 Bernstein AG, Tieloser Weg 6, D-32457 Porta , Off Switch-off distance 12 10 Hysteresis Switch-on distance 8 On 6 4 2 0 -35 , Metal can influence the sensing distance. Active surfaces Connection Pin 1 – DI - white Pin 2 â , notice! Date of issue: 19.06.2012 / Page 2 of 4 Document : 6075988028_en.doc / Last update : 2


Original
PDF D-32457
2011 - 4AV2600-2EB00-0A

Abstract: iron EI core EI - 28 TRANSFORMER IEC 61558-2-6 61558-2-6 siemens EN61131-2 6-155
Text: ; EN 61558-2-6, EN61131-2 >SAFETY ISOLATING TRANSFORMER< General technical details: product , Type of current / of the inputs AC Input voltage · _1 / rated value V 415 · _ 2 / rated , · minimum V 193.5 · maximum V 439.9 · _1 / rated value A 1.55 · _ 2 , 4AV2600-2EB00-0A Page 2 / 3 06/06/2011 subject to modifications © Copyright Siemens AG 2011 Width m


Original
PDF 4AV2600-2EB00-0A EN61131-2 com/WW/view/en/4AV2600-2EB00-0A/all 4AV2600-2EB00-0A iron EI core EI - 28 TRANSFORMER IEC 61558-2-6 61558-2-6 siemens EN61131-2 6-155
CJ1W-TC002 MANUAL

Abstract: plc based phase sequence indication and controlling omron pid example
Text: -Kstep ladder programs in 1 ms (See note.) Note: Basic instructions only 2 D: 65 mm Loop-control CPU , Unit Input channel 1 Temperature input 2 Y1 Adjust PID and other parameters in the , note.) Segment Program 2 Bank Conversion Y1 Y2 X1 Perform program control C_BNK , : CJ1G-CPU44P/45P (CJ1G-CPU42P/43P: Expand up to 2 Racks) Optimum Tuning to Suit the Application Fine , constants (see note 2 ). Note 1: For details on CS-series Loop Control Boards, refer to the PLC-based


Original
PDF EN61131-2, CJ1W-TC002 MANUAL plc based phase sequence indication and controlling omron pid example
REC 53A

Abstract: No abstract text available
Text: * according to EN61131-2 Specifications are subject to change without notice (10.11.2011) 1 REC2B , . REC.A. 24 VDC 15-32 VDC 230 VAC (according to EN61131-2 ) Rated Operational voltage , mechanical counterpart used to switch three phase motors. The range includes 2 and 3 phase switching , power rating Itsm control Connection control REC2: 2 poles REC3: 3 poles B: Instant ON 48: 48-530 VAC D: 24 VDC, -15%, + 20% 2 : 2.2kW 3: 3.0kW 0: Standard G: Clamp Itsm R


Original
PDF 600Vrms. 3RU11 TA25DU-8 3RU1126-1FB0 REC 53A
2012 - TRANSISTOR mcr 100-8

Abstract: AFC8503S
Text: Action indicator EN61131-2 application type No corrosive gases or too much dust Conformed EC Directives Response time EMC Directive: EN61131-2 , Low Voltage Directive: EN61131-2 Specifications , max. Built-in 2 -axis pulse output 50 kHz max.*1 Built-in 2 -channel multifunctional analog input Voltage, thermistor and potentiometer input * 2 When using FP0R extension unit* 2 Built-in calendar/clock* 2 Combined output (Ry+Tr) Built-in RS485 communication port*3 Tr: 4 points, 0.5 A (Only


Original
PDF RS485 1-axis/20 2-axis/20 L40MR, L60MR L40MR L60MR TRANSISTOR mcr 100-8 AFC8503S
2012 - Bernstein D-32457

Abstract: Bernstein Switch D-32457 D-32457 Bernstein D-32457 Porta Westfalica
Text: , Di (digital inputs according to EN61131-2 ) Voltage UHmax UHmin ULmin ULmax Outputs Q1,Q2 , / Page 1 of 4 Document : 6075988029_en.doc / Last update : 2 / 0221-12 Bernstein AG, Tieloser Weg 6 , 6 4 2 0 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 , €“ DI - white Pin 2 – I1 - brown Pin 3 – I2 / Q3 - green Pin 4 – DO - yellow Pin 5 – Q1 - , without notice! Date of issue: 19.06.2012 / Page 2 of 4 Document : 6075988029_en.doc / Last update : 2


Original
PDF D-32457 Bernstein D-32457 Bernstein Switch D-32457 Bernstein D-32457 Porta Westfalica
2012 - Bernstein D-32457

Abstract: Bernstein D-32457 Porta Westfalica D-32457
Text: , Di (digital inputs according to EN61131-2 ) Voltage UHmax UHmin ULmin ULmax Outputs Q1,Q2 , Document : 6075988027_en.doc / Last update : 2 / 0221-12 Bernstein AG, Tieloser Weg 6, D-32457 Porta , Off Switch-off distance 12 10 Hysteresis Switch-on distance 8 On 6 4 2 0 -35 , Metal can influence the sensing distance. Active surfaces Connection Pin 1 – DI - white Pin 2 â , notice! Date of issue: 19.06.2012 / Page 2 of 4 Document : 6075988027_en.doc / Last update : 2


Original
PDF D-32457 Bernstein D-32457 Bernstein D-32457 Porta Westfalica
E41515

Abstract: EN61810-1 EN61131-2 LR31928 G6M-1A12
Text: G6D, with power consumption of 120 mW). Satisfies EN61131-2 and EN61010 requirements. SIL , . Example: G6M-1A 12 VDC Rated coil voltage Model Number Legend G6M - VDC 1 2 3 1. Number of Poles 1: 1 pole 2 . Contact Form A: SPST-NO 3. Rated Coil Voltage 5, 12, 24 VDC , measured at a coil temperature of 23°C with a tolerance of ±10%. 2 . Operating characteristics are measured , Approx. 4 g Approved Standards UL508 (File No. E41515)/CSA C22. 2 No.14 (File No. LR31928


Original
PDF EN61131-2 EN61010 K121-E1-03 E41515 EN61810-1 LR31928 G6M-1A12
2012 - D-32457

Abstract: No abstract text available
Text: , Di (digital inputs according to EN61131-2 ) Voltage UHmax UHmin ULmin ULmax Outputs Q1,Q2 , Document : 6075988030_en.doc / Last update : 2 / 0221-12 Bernstein AG, Tieloser Weg 6, D-32457 Porta , Off Switch-off distance 12 10 Hysteresis Switch-on distance 8 On 6 4 2 0 -35 , Metal can influence the sensing distance. Active surfaces Connection Pin 1 – DI - white Pin 2 â , notice! Date of issue: 19.06.2012 / Page 2 of 4 Document : 6075988030_en.doc / Last update : 2


Original
PDF D-32457
2012 - D-32457

Abstract: No abstract text available
Text: on delay tv Electromagnetic interference Inputs I1,I2, Di (digital inputs according to EN61131-2 , 6075986022 Connection Pin 1 – DI - white Pin 2 – I1 - brown Pin 3 – I2 / Q3 - green Pin 4 – DO , 10 Hysteresis Switch-on distance 8 On 6 4 2 0 -35 -30 -25 -20 -15 -10 , / Page 1 of 3 Document : 6075986022_en.doc / Last update : 2 / 0221-12 Bernstein AG, Tieloser Weg 6 , 2 s +33 ms x following CSMS according to EN IEC 60947-5-2 and EN 61326-3-1 30 V 11 V -3 V 5V


Original
PDF D-32457
2012 - D-32457

Abstract: No abstract text available
Text: on delay tv Electromagnetic interference Inputs I1,I2, Di (digital inputs according to EN61131-2 , 6075986024 Connection Pin 1 – DI - white Pin 2 – I1 - brown Pin 3 – I2 / Q3 - green Pin 4 – DO , 10 Hysteresis Switch-on distance 8 On 6 4 2 0 -35 -30 -25 -20 -15 -10 , / Page 1 of 3 Document : 6075986024_en.doc / Last update : 2 / 0221-12 Bernstein AG, Tieloser Weg 6 , 2 s +33 ms x following CSMS according to EN IEC 60947-5-2 and EN 61326-3-1 30 V 11 V -3 V 5V


Original
PDF D-32457
2012 - D-32457

Abstract: No abstract text available
Text: on delay tv Electromagnetic interference Inputs I1,I2, Di (digital inputs according to EN61131-2 , 6075985025 Connection Pin 1 – DI - white Pin 2 – I1 - brown Pin 3 – I2 / Q3 - green Pin 4 – DO , 10 Hysteresis Switch-on distance 8 On 6 4 2 0 -35 -30 -25 -20 -15 -10 , / Page 1 of 3 Document : 6075985025_en.doc / Last update : 2 / 0221-12 Bernstein AG, Tieloser Weg 6 , 2 s +33 ms x following CSMS according to EN IEC 60947-5-2 and EN 61326-3-1 30 V 11 V -3 V 5V


Original
PDF D-32457
Supplyframe Tracking Pixel