The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
PMP5660.2 Texas Instruments Multi-Transformer 2x25V (50V@700mA)
PMP5660.1 Texas Instruments Multi-Transformer 2x25V (390V@192mA)

EEL 22w transformer Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2009 - eel 19 transformer

Abstract: eel - 19 transformer Eel19 core EEL-19 transformer eel-19 EEL19 AE eel 19 Core/EEL-19 EEL19 transformer core EEL19 transformer
Text: 2 6 Np/2 3 Na 4 5 Figure 12. Transformer Specification 2 Core: EEL -19 (Ae , transformer , selecting the components, feedback loop design, and design tips to maximize efficiency. For , minimized. The transformer size can be reduced using DCM because the average energy storage is low , the Transformer Primary-Side Inductance (LM) The transformer primary-side inductance is determined , primary-side inductance (LM) of the transformer is obtained as: LM = Because the actual drain voltage


Original
PDF AN-8024 90VAC 264VAC eel 19 transformer eel - 19 transformer Eel19 core EEL-19 transformer eel-19 EEL19 AE eel 19 Core/EEL-19 EEL19 transformer core EEL19 transformer
eel - 19 transformer

Abstract: eel 19 transformer Transformer eel 25 5908 Tube 5908 subminiature tubes EEL 22 transformer EEL-22T transformer
Text: ) Plate Resistance. Conversion Transconductance Direct Transformer Input . Grid No. 1 Voltage , Heater Current. Grid Current : Ec2 = Eb = 50 Vdc; Eel Rgl = 0.1 Meg. Plate Current (1):. -1.5 Vdc; Plate Current (2): Eel = -5 Vdc; Rgl = 0. Grid No. 2 Current , = -7.0 Vdc; Eel = 0; Rgl = 0. 100 AF Noise: Esig = 70 m Vac; Rg2 = , = Eel = Ec2 = Rgl = 0. Intermittent Life Test: Note 2 Rgl = 2.2 Meg; Ehk = +200 Vdc; TA = 175Â


OCR Scan
PDF E8-10, eel - 19 transformer eel 19 transformer Transformer eel 25 5908 Tube 5908 subminiature tubes EEL 22 transformer EEL-22T transformer
2008 - eel-22w

Abstract: EEL 22w transformer EEL22w transformer EEL22w FAN7314 12v to 220 v ac inverter SCHEMATIC DIAGRAM D604 power mosfet CN603 d609 EEL22
Text: //220p C624 1u R626 1k R623 1k Figure 9. Typical Application Circuit 2. Transformer Specifications Supported by Clover Hitech (http://www.cloverhitech.com) PART NO : EEL-22W Pin No. 2 3 1 4 7 , operating frequency range is between 30kHz and 250kHz, depending on the CCFL and the transformer


Original
PDF FAN7314A 20-Pin FAN7314A eel-22w EEL 22w transformer EEL22w transformer EEL22w FAN7314 12v to 220 v ac inverter SCHEMATIC DIAGRAM D604 power mosfet CN603 d609 EEL22
2004 - APA4863

Abstract: A70 tssop
Text: APA4863 Stereo 2.2W Audio Power Amplifier Features · · · · Depop Circuitry Integrated Thermal Shutdown Circuitry Integrated Bridge-Tied Load (BTL) or Single-Ended (SE) Modes Operation Output Power at 1% THD+N, VDD=5V - 2.2W /Ch (typ) into a 3 Load - 1.8W/Ch (typ) into a 4 Load - 1.2 W/Ch (typ) into a 8 , capable of delivering 2.2W /1.8W/1.2W of continuous RMS power per channel into 3/4/8 bridge-tied loads with , TU : Tube TR : Tape & R eel T Y : T ra y L e a d F re e C o d e L : L e a d F re e D e v ic e B la n


Original
PDF APA4863 APA4863 A70 tssop
5636 TUBE

Abstract: eel 19 transformer sylvania, transformer subminiature tubes EEL transformer eel - 19 transformer
Text: €” Conversion Transconductance Direct Transformer Input. . — •— 1400 Mmhos NOTES: 1 , (2): Eel = -7.5 Vdc. Transconductance (2): Smglp Ef = 24.0 V , 4.11.5 4.11.4 Heater Cycling Life Test: Ef = 29.0 V; Eb = Eel = Ec2 = Ec3 = O V; Rk = 0 Ohms; Ehk = , CHARACTERISTICS PAGE 15 DIRECT ( TRANSFORMER ) INPUT 1 1 cs fee 38 , SYLVANIA 5916 PAGE 16 AVERAGE CONVERSION CHARACTERISTICS DIRECT ( TRANSFORMER ) INPUT 3.20 2.80 2.40


OCR Scan
PDF E8-10, 5636 TUBE eel 19 transformer sylvania, transformer subminiature tubes EEL transformer eel - 19 transformer
EEL16

Abstract: core EEL16 transformer EEL16 transformer EEL-16 6 TRANSFORMER EeL16 EEL-16 Transformer eel 25 230 AC to 18V ac transformer eel -16 PM130-H1A
Text: UPDATED TO UL CLASS (B) 130 INSULATION SYSTEM 13.5 (.531) EEL -16, 10-PIN VERTICAL BOBBIN P , SCALE DRAWING TRANSFORMER CONTROL DRAWING PREMIER P/N: TSD-1055 REVISION: 06/03/99 ENGR: A. SANTOS , -1055 Switch Mode Transformer was designed for use with Power Integrations, Inc. PWR-TOP210P three terminal , can provide isolated multiple outputs with efficiencies up to 90%. Premiers' TSD-1055 transformer has , switching regulators provide a very simple solution to off-line designs. The inductors and transformer used


Original
PDF 250Vrms 15/18V FORZV87-C200 UF4002 15/18Vdc UF4005 PWR-TOP210P 100uF BAV21 EEL16 core EEL16 transformer EEL16 transformer EEL-16 6 TRANSFORMER EeL16 EEL-16 Transformer eel 25 230 AC to 18V ac transformer eel -16 PM130-H1A
2006 - lnk304pn

Abstract: core EEL16 transformer EEL16 transformer EEL16 LNK304PN pin details LinkSwitch-TN* with flyback transformer topswitch StackFET StackFET 1N4007 operating frequency TRANSFORMER EeL16
Text: flyback topology delivers full load over extremely wide input voltage range · E-ShieldTM transformer , to one end of the transformer primary winding. The 450 V input capacitors are stacked with parallel , catastrophic failure. Inductor L1, C1 and transformer E-Shield windings allow the design to meet EN55022 B , (cascode). The drain of U1 drives the source of Q1 while the drain of Q1 drives the transformer primary , , Q1 is also turned on, applying the input voltage across the transformer primary. Once the primary


Original
PDF DI-124 LNK304PN DI-124 lnk304pn core EEL16 transformer EEL16 transformer EEL16 LNK304PN pin details LinkSwitch-TN* with flyback transformer topswitch StackFET StackFET 1N4007 operating frequency TRANSFORMER EeL16
2006 - LNK304PN

Abstract: EEL16 LNK304PN pin details 1N4007 operating frequency EEL16 transformer core EEL16 transformer FREE DOWNLOAD PDF LNK304PN topswitch StackFET eel-16 EEL16 bobbin
Text: flyback topology delivers full load over extremely wide input voltage range · E-ShieldTM transformer , to one end of the transformer primary winding. The 450 V input capacitors are stacked with parallel , catastrophic failure. Inductor L1, C1 and transformer E-Shield windings allow the design to meet EN55022 B , (cascode). The drain of U1 drives the source of Q1 while the drain of Q1 drives the transformer primary , , Q1 is also turned on, applying the input voltage across the transformer primary. Once the primary


Original
PDF DI-124 LNK304PN DI-124 LNK304PN EEL16 LNK304PN pin details 1N4007 operating frequency EEL16 transformer core EEL16 transformer FREE DOWNLOAD PDF LNK304PN topswitch StackFET eel-16 EEL16 bobbin
TUBE 7199

Abstract: 7199 tube ecc83 data 8417 tube 12AX7 ECC83 equivalent eel - 19 transformer ECC83 tube 7025 tube eel 19 transformer
Text: — 12.5 20 24 15 17 Watts Total Harmonic Distortion . — 2 1.5 2 2 4 Percent Eel for lb â , .1.5 1.2 Percent ^(1)'obtained from taps on the primary winding of the output transformer . The taps are , of each output tube. (2) Obtained from taps on the primary winding of the output transformer . The , Ohms 16.5 Watts 3 Percent output transformer 7199 PREAMPLIFIER (P) PHASE INVERTER (T) Medium Mu Triode , .0.0081 1.0 0.4 Megohm Eel for lb = 10(Approx.) .40 4 —Volts


OCR Scan
PDF
2006 - core EEL16 transformer

Abstract: EEL16 EEL16 transformer topswitch StackFET 1N4007 operating frequency StackFET TRANSFORMER EeL16 LinkSwitch-TN* with flyback transformer lnk304 flyback transformer pin LNK304P
Text: the source of Q1 while the drain of Q1 drives the transformer primary. The drain voltage of U1 is , delivers full load over extremely wide input voltage range E-ShieldTM transformer construction for , internal MOSFET turns on, Q1 is also turned on, applying the input voltage across the transformer primary , filtered and the resultant DC applied to one end of the transformer primary winding. The 450 V input , to R4 provide fusing in case of a catastrophic failure. Inductor L1, C1 and transformer E-Shield


Original
PDF DI-124 LNK304 core EEL16 transformer EEL16 EEL16 transformer topswitch StackFET 1N4007 operating frequency StackFET TRANSFORMER EeL16 LinkSwitch-TN* with flyback transformer lnk304 flyback transformer pin LNK304P
2013 - Mitsubishi th-n20kp

Abstract: AD16-22DS Kyoritsu 3301 kyoritsu model 1008 ksd 302 250v, 10a terasaki xh100ns KSD 166 16a 250v carlo gavazzi VDE 0660 ksd 250v 10a EEL 22w transformer
Text: Instruments 18 – 20 Voltage Regulator Transformer 21 PEOPLE Prices Are Subjected To Changes , Isolator 72 72 72 72 Auto Transformer 73 OMRON TAMCO TERASAKI VISIONTECH ZENITH , PUSH BUTTON SW KC6-SB2-EW SB2-EV18 25mm 240V TRANSFORMER PILOT LAMP KC6-SB2-EV18 SB2-BW3471 22mm , KH1-FC16T9/EX-D40W FC8T9/D 22W FC12T9/D 32W FC16T9/D 40W FC8T9/WW 22W FC12T9/WW 32W FC16T9/WW 40W FC8T9/EX-D 22W FC12T9/EX-D 32W FC16T9/EX-D 40W Description Glow Starter Straight Fluorescent Lamp


Original
PDF 100HP) 125HP) 112KW 150HP) 135KW 180HP) 150KW 200HP) 164KW 220HP) Mitsubishi th-n20kp AD16-22DS Kyoritsu 3301 kyoritsu model 1008 ksd 302 250v, 10a terasaki xh100ns KSD 166 16a 250v carlo gavazzi VDE 0660 ksd 250v 10a EEL 22w transformer
D83-004

Abstract: D92-02 d83 004 d83-004 diode d92 02 diode D83 d83004 diode D83 004 diode d92-02 SG6105
Text: . Schematic.P2 B. BOM.P5 C. Transformer & Output Inductor.P11 , (Ver:1.0) PCB PC-2136 Rev:C T1 EEL -25 T3 TRN0167_EE-16(Ver:1.0) T4 TRN0169_EE-16(Ver:1.0) T8 , Dip SE 10/32 Doc.Title Transformer & Output Inductor Institute by Doc.Number A0 Page Number CTransformer & Output Inductor 11 SE 11/32 Doc.Title Transformer & Output Inductor Institute by Doc.Number A0 Page Number 12 SE 12/32 Doc.Title Transformer & Output Inductor


Original
PDF SG6105 D83-004 D92-02 d83 004 d83-004 diode d92 02 diode D83 d83004 diode D83 004 diode d92-02 SG6105
Ortel

Abstract: Ortel 2606B ortel f PIN Photodiode For CATV Receiver 2606B photodiode receiver
Text: internal transformer . 2. Measured into 75ohm load. 3. Two laser test. Each laser has 40% modulation index , Type Pigtail single mode 9/125 |jm, 2 to 3 meters in length. Optical Conn eel or None Absolute


OCR Scan
PDF 606A/B 606A/B_ B30247A July/96 Ortel Ortel 2606B ortel f PIN Photodiode For CATV Receiver 2606B photodiode receiver
2003 - L/H 94v-0

Abstract: schematic diagram lightning protection GR-1089 LC05-6 SRDA05-4
Text: -1089. This design takes advantage of the isolation of the transformer to suppress common mode surges. To , of transients that are coupled through the transformer . 2003 Semtech Corp. 4 , Ordering Information Par t Number Working Voltage Qty per Reel R eel Size LC05-6.TB 6V


Original
PDF LC05-6 LC05-6 SO-16 LC05-06 SO-16 L/H 94v-0 schematic diagram lightning protection GR-1089 SRDA05-4
6jv8

Abstract: combined video
Text: DESIGNED FOR USE AS A VIDEO AMPLIFIER. THE HEATER MAY BE OPERATED FROM A TRANSFORMER OR IN A SERIES STRING , CHARACTERISTICS Eel =0 INSTANTANEOUSLY PLATE VOLTAGE 40 60 VOLTS GRID 2 VOLTAGE . 125 200 VOLTS


OCR Scan
PDF
3acp2

Abstract: 3ACP1 cathode ray tube 3ACP7 3ACP11A 3ACP11 cathode ray
Text: 8) Note 1 Cathode should be returned to one side or to the midtap of the heater transformer winding. Note 2 Eel = 0 Volts DC. Note 3 Visual extinction of undeflected focused spot. Note 4 Ib3= 25 ¡/a


OCR Scan
PDF 12-pin B12-37 3ACP11A 50flA 3acp2 3ACP1 cathode ray tube 3ACP7 3ACP11A 3ACP11 cathode ray
8jv8

Abstract: rs tube combined video
Text: TRANSFORMER OR IN A SERIES STRING. DIRECT INTERELECTRODE CAPACITANCES WITHOUT EXTERNAL SHIELD TRIODE: GRID , GRID 1 VOLTAGE FOR lbs20/tA (APPROX.) -5 -5.5 -9 VOLTS KNEE CHARACTERISTICS Eel =0 INSTANTANEOUSLY


OCR Scan
PDF
eel 19 transformer

Abstract: eel - 19 transformer newark 30-FRAME Scans-0017366 25AV5GT Mum 84 EEL-16 horizontal transformer
Text: TRANSFORMER HORIZONTAL-YOKE DRIVE. RATINGS INTERPRETED ACCORDING TO RMA STANDARD M8-210 HORIZONTAL , DIRECT OR WITH TRANSFORMER HORIZONTAL-YOKE DRIVE. DIRECT INTERELECTRODE CAPACITANCES GRID »i to , 150 VOLTS. FWITH Eb = Ec2 = 150 VOLTS AND Eel = -22.5 VOLTS. —VINDICATES A CHANGE OR ADDITION


OCR Scan
PDF 25AV5GT 25AV5GT M8-210 eel 19 transformer eel - 19 transformer newark 30-FRAME Scans-0017366 Mum 84 EEL-16 horizontal transformer
2001 - lc036

Abstract: marking LC036 LC03-6
Text: isolation of the transformer to suppress common mode surges. To complete the protection circuit, the SRDA05 , the transformer . For further information, reference Semtech application note AN97-10 T3/E3 & STS , Ordering Information Par t Number LC03-6.TB LC03-6.TE Working Voltage 6V 6V Qty per Reel 500 2500 R eel


Original
PDF LC03-6 LC03-6 lc036 marking LC036
2003 - land pattern for so-16

Abstract: LC04
Text: requirements of Bellcore GR-1089. This design takes advantage of the isolation of the transformer to suppress , latching up by providing fine clamping of transients that are coupled through the transformer . The , Number LC04-6.TB LC04-6.TE Working Voltage 6V 6V Qty per Reel 500 2500 R eel Size 7 Inch 13 Inch Note


Original
PDF LC04-6 SO-16 LC04-6 SO-16 land pattern for so-16 LC04
2003 - FA2003

Abstract: No abstract text available
Text: design takes advantage of the isolation of the transformer to suppress common mode surges. To complete , transients that are coupled through the transformer . For further information, reference Semtech application , Voltage 6V 6V Qty per Reel 500 2500 R eel Size 7 Inch 13 Inch Note: (1) No suffix indicates tube pack


Original
PDF 5/50ns) LC03-6 LC03-6 FA2003
2011 - UC2804

Abstract: No abstract text available
Text: , the transformer will provide a high level of common mode isolation to external voltages, but no , one line, through the transformer and back to the source. As the current flows, it charges the windings of the transformer on the line side. Once the surge is removed, the windings on the line side , of the transformer as close to the magnetics as possible. This is done to minimize parasitic inductance and improve clamping performance. In this design, the isolation voltage of the transformer is


Original
PDF uClamp2804L 2804L Clamp2804L UC2804
Not Available

Abstract: No abstract text available
Text: EEL 7" R EEL 13" R EEL 7" R EEL CAUTION , 8010s can be used along with a transformer to create a high power differential line driver. T h e differential configuration effectively doubles the output swing, while the step-up transformer further


OCR Scan
PDF AD8010 16-Lead
2009 - eel -16-2005

Abstract: upd78f0547 78f0547 upd78f05 TMC51 uPD78F0547A
Text: . . . . . . . . . . . . . . . . . . . . . 2.2.4 EEL anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.5 EEL , . . . . . . . . . . . . . . . . 2.2.6 EEL block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.7 EEL reference , . . . . . . 2.2.8 EEL instance lookup table . . . . . . . . . . . . . . . . . . . . . . . . . . .


Original
PDF U18991EE2V0AN00 78K0/Ix2/Kx2-L/Dx2/uCFL/LIN4) U18991EE1V0AN00. eel -16-2005 upd78f0547 78f0547 upd78f05 TMC51 uPD78F0547A
2011 - UC2804

Abstract: eel - 19 transformer 2804L Pulse Transformer for ethernet UCLAMP2804L EEL 16 transformer eel 19 transformer
Text: , resistors, capacitors, and protection are also available. In either case, the transformer will provide a , ) surges. During a metallic transient event, current will flow into one line, through the transformer and back to the source. As the current flows, it charges the windings of the transformer on the line side , Figure 3. One device is placed across two line pairs and is located on the PHY side of the transformer as , performance. In this design, the isolation voltage of the transformer is relied upon to suppress common mode


Original
PDF 2804L Clamp2804L uC2804L UC2804 eel - 19 transformer Pulse Transformer for ethernet UCLAMP2804L EEL 16 transformer eel 19 transformer
Supplyframe Tracking Pixel