LT1213ACS8 Linear Technology IC DUAL OP-AMP, 400 uV OFFSET-MAX, 28 MHz BAND WIDTH, PDSO8, Operational Amplifier
LT1213ACJ8 Linear Technology IC DUAL OP-AMP, 400 uV OFFSET-MAX, 28 MHz BAND WIDTH, CDIP8, Operational Amplifier
LT1211ACS8 Linear Technology IC DUAL OP-AMP, 400 uV OFFSET-MAX, 14 MHz BAND WIDTH, PDSO8, 0.150 INCH, PLASTIC, SO-8, Operational Amplifier
LT1211ACJ8 Linear Technology IC DUAL OP-AMP, 400 uV OFFSET-MAX, 14 MHz BAND WIDTH, CDIP8, HERMETIC SEALED, CERDIP-8, Operational Amplifier
LTC6240HVIS8 Linear Technology IC OP-AMP, 400 uV OFFSET-MAX, 18 MHz BAND WIDTH, PDSO8, 0.150 INCH, PLASTIC, SOP-8, Operational Amplifier
LTC6240HVIS5 Linear Technology IC OP-AMP, 400 uV OFFSET-MAX, 18 MHz BAND WIDTH, PDSO5, PLASTIC, MO-193, TSOT-23, 5 PIN, Operational Amplifier
SF Impression Pixel

Search Stock (5)

  You can filter table by choosing multiple options from dropdownShowing 5 results of 5
Part Manufacturer Supplier Stock Best Price Price Each Buy Part
DPM 400 Lascar Electronics Newark element14 79 $38.45 $38.45
DPM 400 Lascar Electronics Allied Electronics & Automation - $62.83 $41.77
DPM 400 Lascar Electronics RS Components 149 £29.35 £27.82
DPM 400 Lascar Electronics element14 Asia-Pacific 99 $41.64 $39.53
DPM 400 Lascar Electronics Farnell element14 81 £29.35 £27.26

No Results Found

DPM+400 datasheet (1)

Part Manufacturer Description Type PDF
DPM 400 Others LCD ANZEIGEMODUL 48X24X9.2 Original PDF

DPM+400 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
DPM-6D27J

Abstract: cde DPFF ML0039 y427
Text: DPFF DETAILED CATALOG INFORMATION 200/250 Vic (155 Vac) 400 Vdc (200 Vac) ! i | i | I Cap. Ml , | I)" (mm) Max. . 400 (10.2) . 400 (10.2) . 400 (10.2) . 400 (10.2) . 400 (10.2) . 400 (10.2) f [ | L" (mm , DPFF6D39J DPM-6D47J DPFF6D56J DPFF6D68J DPM-6D82J DPFF6S1J DPFF6S12J "| ~| "| ~| I)" (mm) Max. . 400 (10.2) . 400 (10.2) . 400 (10.2) . 400 (10.2) . 400 (10.2) . 400 (10.2) . 400 (10.2) .450(11.4) .450(11.4) .450(11.4


OCR Scan
PDF DPFF16S33J DPM-6D27J cde DPFF ML0039 y427
conn sil

Abstract: conn sil 2 voltmeter lcd voltmeters LED Backlit panel 750-140 low voltage ac voltmeter SP400-EB-W 8 way dip switch lcd md640.400
Text: SP400-EB DPM 750S-EB RoHS SP 400 -EB-R SP 400 -EB-P SP 400 -EB-B SP 400 -EB-O SP 400 -EB-G SP 400 -EB-W SP 400 -EB-M SP 400 -EB-Y Standard Bezel Fixing Waterproof Bezel Fixing INDEX This range of 31/2 , DPM 750S-BL (BEZ 700-IP). When placing an order for either SP 400 -EB or DPM 750-EB, confirm your LED


Original
PDF 31/2-digit 400-EB 750-EB, SP400-EB-W 750S-EB-W 700-IP conn sil conn sil 2 voltmeter lcd voltmeters LED Backlit panel 750-140 low voltage ac voltmeter 8 way dip switch lcd md640.400
dpm 56

Abstract: precision 4-20ma current source potenziometri
Text: ,0 x 18,0 (1,50 x 0,71) Epaisseur panneau 1,0 à 2,5 (0,04 to 0,1) 40.0 (1.57) a b c d , desired reading at 4mA from the desired reading at 20mA: -1500 - (- 400 ) = 1900 Short jumper link Lk1 with , 342 indicates the desired reading at 4mA: - 40.0 Adjust CAL and OFF as necessary for optimum accuracy , DP2 DP1 Example to re-calibrate: Meter to read - 40.0 for 4mA and 150.0 for 20mA. 3. 4. 5 , lecture souhaitée à 20mA: -1500 (- 400 ) = 1900 Court-circuitez le cavalier Lk1 avec l'embase de liaison


Original
PDF November/1999 Novembre/1999 dpm 56 precision 4-20ma current source potenziometri
jb 742

Abstract: 742-BL DPM 400
Text: used to display one of the decimal points if necessary. Example to re-calibrate: Meter to read - 40.0 , desired reading at 20mA: 1500 - (- 400 ) = 1900 2. Place Jumper Link Lk1 with the link header normally used , 742-BL indicates the desired reading at 4mA: - 40.0 8. Adjust Span and Offset as necessary for optimum , untill the reading is - 40.0 . Repeat step 8 until correct readings are obtained at 4mA and at 20mA


Original
PDF 742-BL 4-20mA 742-BL 700-r 4-20mA jb 742 DPM 400
4-20mA Transmitter

Abstract: DPM 400 jb 742 742-BL DPM 50
Text: used to display one of the decimal points if necessary. Example to re-calibrate: Meter to read - 40.0 , desired reading at 20mA: 1500 - (- 400 ) = 1900 2. Place Jumper Link Lk1 with the link header normally used , 742-BL indicates the desired reading at 4mA: - 40.0 8. Adjust Span and Offset as necessary for optimum , untill the reading is - 40.0 . Repeat step 8 until correct readings are obtained at 4mA and at 20mA


Original
PDF 742-BL 4-20mA 742-BL 700-Other 4-20mA 4-20mA Transmitter DPM 400 jb 742 DPM 50
4.20 mA Transmitter

Abstract: a-4-20mA 4-20mA 4-20mA transmitter block diagram of power meter jb 742 5v to 4 20ma DPM 400 0...5 4-20mA current transmitter 4...20 mA
Text: points if necessary. Example to re-calibrate: Meter to read - 40.0 at 4mA and 150.0 at 20mA. 1. Calculate the Span by subtracting the desired reading at 4mA from the desired reading at 20mA: 1500 - (- 400 , 4mA: - 40.0 8. Adjust Span and Offset as necessary for optimum accuracy. First apply 20mA and adjust Span untill the reading is 150.0. Then apply 4mA and adjust Offset untill the reading is - 40.0


Original
PDF 742-BL 4-20mA 742-BL 700-ransmitter 4-20mA 4.20 mA Transmitter a-4-20mA 4-20mA transmitter block diagram of power meter jb 742 5v to 4 20ma DPM 400 0...5 4-20mA current transmitter 4...20 mA
4 digit lcd 4-20mA input

Abstract: sp5 potentiometer 4-20mA Transmitter
Text: mm (inches) 40.0 (1.57) b c d a. b. c. d. 2.00 6.00 1.60 9.50 (0.08) (0.24 , used to display one of the decimal points if necessary. Example to re-calibrate: Meter to read - 40.0 , desired reading at 20mA: -1500 - (- 400 ) = 1900 2. Short jumper link Lk1 with the link header normally , the desired reading at 4mA: - 40.0 8. Adjust CAL and OFF as necessary for optimum accuracy, by


Original
PDF 4-20mA 4-20mA April/2008 4 digit lcd 4-20mA input sp5 potentiometer 4-20mA Transmitter
4 digit lcd 4-20mA input

Abstract: 6 digit lcd 4-20mA input dpm 56 DPM342 SPW 079
Text: DIMENSIONS All dimensions in mm (inches) 40.0 (1.57) b c d a. b. c. d. 2.00 6.00 1.60 , display one of the decimal points if necessary. Example to re-calibrate: Meter to read - 40.0 for 4mA and , reading at 20mA: -1500 - (- 400 ) = 1900 2. Short jumper link Lk1 with the link header normally used to , reading at 4mA: - 40.0 8. Adjust CAL and OFF as necessary for optimum accuracy, by repeating steps 2 to 7


Original
PDF 4-20mA 4-20mA June/1998 4 digit lcd 4-20mA input 6 digit lcd 4-20mA input dpm 56 DPM342 SPW 079
SPW 079

Abstract: I 342 DPM 160 spw -079
Text: DIMENSIONS All dimensions in mm (inches) 40.0 (1.57) b c d a. b. c. d. 2.00 6.00 1.60 , necessary. Example to re-calibrate: Meter to read - 40.0 for 4mA and 150.0 for 20mA. 1. Calculate the span by subtracting the desired reading at 4mA from the desired reading at 20mA: -1500 - (- 400 ) = 1900 2 , . Adjust the OFF potentiometer so the DPM 342 indicates the desired reading at 4mA: - 40.0 8. Adjust CAL


Original
PDF 4-20mA 4-20mA August/2002 SPW 079 I 342 DPM 160 spw -079
lcd voltmeters

Abstract: 3.5-DIGIT lcd LCD 3.5-DIGIT 1025S-0 dpm 950 lcd Voltmeter LCD200MV DPM 2AS 742-BL 3.5 digit lcd
Text: -BL 35.0 22.3 17.0 9.7 2.0 6.0 1.6 6.0 8.25 33.0 x 15.0 1.0 - 2.5 DPM 3AS-BL 40.0 27.3 20.0 , * £*.* SP 300 and SP 400 Evaluation Unit SP EVAL · · · · · Complete evaluation system Accelerates system development Battery powered (9V PP3 supplied) SP 300 and SP 400 modules supplied with kit Immediate integration into many applications See SP 300 and SP 400 for module specifications. SP EVAL


Original
PDF 120mm 100mV lcd voltmeters 3.5-DIGIT lcd LCD 3.5-DIGIT 1025S-0 dpm 950 lcd Voltmeter LCD200MV DPM 2AS 742-BL 3.5 digit lcd
DPM 24 96

Abstract: DPM 24 48 2000 d DPM24 999mA panel-meter SNT13 DPM 300 DPM 48/96
Text: : Response time: Voltage measurement: Measuring range Display range Max. input Input resistance 400 V 0.2V-1 V 1 V -10V 10V-100V 100 V-300V ± 2000 counts 400 V 400 V 400 V 1058 kOhm ± 1


OCR Scan
PDF SNT13 DPM 24 96 DPM 24 48 2000 d DPM24 999mA panel-meter DPM 300 DPM 48/96
SPW 079

Abstract: No abstract text available
Text: dimensions in mm (inches) 40.0 (1.57) b c d a. b. c. d. 2.00 6.00 1.60 9.50 (0.08 , : Meter to read - 40.0 for 4mA and 150.0 for 20mA. 1. Calculate the span by subtracting the desired reading at 4mA from the desired reading at 20mA: -1500 - (- 400 ) = 1900 2. Short jumper link Lk1 with the , DPM 342 indicates the desired reading at 4mA: - 40.0 8. Adjust CAL and OFF as necessary for optimum


Original
PDF 4-20mA 4-20mA July/2001 SPW 079
Di 762

Abstract: DM 024 DH-06 DH06 DM-300 R dh08 DS 94V-0 DP10T DH-08 DH-04
Text: and rubber. Specifications and Dimensions subject to change DS(R) . 400 10,16 MAX DIM "A" 1 2 9 4 , ) 10.16(. 400 ) DS(R)-06 16.76(.660) 12.70(.500) DS(R)-07 19.30(.760) 15.24(.600) DS(R)-08 21,84(.860 , ) 2.54(.100) DA-03 8.98(.354) 5.08(.200) DA-04 11.52(.454) 7.62(.300) DA-05 14.06(.554) 10.16(. 400 , ) 10.16(. 400 ) DP(L)-06 16.80(.661) 12.70(.500) DP(L)-07 19.34(.761) 15.24(.600) DP(L)-08 21.88(.861 , (.455) 7.62(.300) DPM(R)-05 14.10(.555) 10.16(. 400 ) DPM(R)-06 16.64(.655) 12.70(.500) DPM(R)-07 19.18


OCR Scan
PDF 100mA, 50VDC. 24VDC. 500VDC 500VAC DH-02 DH-04 DH-06 DH-08 DH-10 Di 762 DM 024 DH06 DM-300 R dh08 DS 94V-0 DP10T
1995 - PH 4148

Abstract: digital thermometer circuit LM35 display by LCD thermometer circuit LM35 display by LCD ph meter circuit 257206 Digital Frequency Meter lm35 to 4-20ma VU meter with LCD ph 4148 f dpm2000
Text: ) The following meters are suitable for this application: Meter DPM 125 DPM 200(S) DPM 300S DPM 400 , ) Types DPM 116, 125, 400 , 500 V+ If we re-draw Figure 8(a) we will see that small impedances (Rs , 200 DPM 300S DPM 400 DPM 500 DPM 500S DPM 700 DPM 700S DPM 2000 Full scale


Original
PDF 200mV 100mV) PH 4148 digital thermometer circuit LM35 display by LCD thermometer circuit LM35 display by LCD ph meter circuit 257206 Digital Frequency Meter lm35 to 4-20ma VU meter with LCD ph 4148 f dpm2000
1999 - 0 280 130 032

Abstract: No abstract text available
Text: 250 400 630 34 51 69 http://www.cornell-dubilier.com/Hdpm.htm DPM all Page 1 of 2 TYPE , ) .590 (15.0) .890 (22.5) .890 (22.5) .890 (22.5) 1.080 (27.5) 1.080 (27.5) 1.575 ( 40.0 ) 1.575 ( 40.0 ) 1.575 ( 40.0 ) d"(mm) .024 (.6) .024 (.6) .024 (.6) .024 (.6) .024 (.6) .024 (.6) .024 (.6) .032 (.8) .032 (.8) .032 (.8) .032 (.8) .032 (.8) .032 (.8) .032 (.8) .032 (.8) .032 (.8) .032 (.8) .032 (.8) 400 , ) .890 (22.5) .890 (22.5) 1.080 (27.5) 1.080 (27.5) 1.080 (27.5) 1.575 ( 40.0 ) 1.575 ( 40.0 ) 1.575 ( 40.0


Original
PDF 000MOhms DPM6S15K DPM6S22K DPM6S33K DPM6S47K DPM6S68K DPM6P15K DPM6P22K DPM6P33K DPM6P47K 0 280 130 032
1997 - digital thermometer circuit LM35 display by LCD

Abstract: ph 4148 ph meter circuit thermometer circuit LM35 display by LCD ac voltmeter ad636 temperature sensor with 7 segment display LM35 ph 4148 f ph 4148 1n DPM200 tip 7805
Text: ) The following meters are suitable for this application: Meter DPM 125 DPM 200(S) DPM 300S DPM 400 , ) Types DPM 116, 125, 400 , 500 V+ If we re-draw Figure 8(a) we will see that small impedances (Rs , Module type DPM 200 DPM 300S DPM 400 DPM 500 DPM 500S DPM 700 DPM 700S DPM 2000


Original
PDF 200mV 100mV) digital thermometer circuit LM35 display by LCD ph 4148 ph meter circuit thermometer circuit LM35 display by LCD ac voltmeter ad636 temperature sensor with 7 segment display LM35 ph 4148 f ph 4148 1n DPM200 tip 7805
1994 - ph meter circuit

Abstract: v to f converter lm 7805 scr D106 ph 4148 f temperature sensor with 7 segment display LM35 DPM2000S "DPM 40" ph 4148 lm35 to 4-20ma 7805 5V internal circuit
Text: /260-044 Adding an offset DPM 300S 260-038 Some applications need the meter to have an offset DPM 400 , Rs to be (c) Types DPM 200, 700 and 2000 (d) Types DPM 116, 125, 400 , 500 6mWto cause a 2 count , Module type DPM 40 DPM 45 DPM 125/116 DPM 200 DPM 300S DPM 400 DPM 500 DPM 500S DPM 700 DPM 700S DPM 2000


Original
PDF F16869 200mV 100mV) ph meter circuit v to f converter lm 7805 scr D106 ph 4148 f temperature sensor with 7 segment display LM35 DPM2000S "DPM 40" ph 4148 lm35 to 4-20ma 7805 5V internal circuit
1995 - thermal printer interface sample code

Abstract: DPM 24 48 2000 d DPM 24 40000 mf NICR-NIal DPM 24 96 DPM24 DPM 50 15 pin DPM48 IEC584 DPM 48/96
Text: 400 V t 650 V t DC-V auto t AC-µ0.5 V t1V t5V t 10 V t 20 V t 50 V t 100 V t 500 V t 650 V , . Cond.) resolution -210 / 1200 1.5°C -200 / 900 1°C -260 / 400 1°C -200 , 1230 -50 1340 400 / / / / / / / / -50 0 1000 1230 1770 1340 1770 1820 2


Original
PDF
DPM 3

Abstract: BC237
Text: ) 40.0 (1.57) a 12.7 (0.50) e b c d a. b. c. d. e. f. g. h. 2.00 6.00 1.60


Original
PDF 200mV 200mV August/2002 DPM 3 BC237
1998 - ph 4148

Abstract: ph 4148 f ph 4148 1n VU meter with LCD ph meter circuit lm35 to 4-20ma ac voltmeter ad636 temperature sensor with 7 segment display LM35 DPM 40 lm 7805 pin out
Text: * DPM 200(S) DPM 300S DPM 400 * DPM 500S DPM 700 (S) DPM 2000(S) RS stock no. 257-212* 260-050 , ) Types DPM 116, 125, 400 , 500 V+ V+ IN HI IN HI V IN IN LO IN LO 0V REF LO , 255-963 DPM 45 257-212/ 260-268 DPM 125/116 DPM 200 DPM 300S DPM 400 DPM 500 DPM


Original
PDF 200mV 100mV) ph 4148 ph 4148 f ph 4148 1n VU meter with LCD ph meter circuit lm35 to 4-20ma ac voltmeter ad636 temperature sensor with 7 segment display LM35 DPM 40 lm 7805 pin out
1993 - DPM 24 48 2000 d

Abstract: NICR-NIal thermocouple passive sensor DPM 24 96 DPM 160 DPM 24 40000 chromel IEC584 IEC 584 inductive load relays 48VDC
Text: opassive o 40 V Measured value opassive o9600 Baudrate oactive o 200 V a 2 o Display Hold o 4800 o 400 , / 900 1°C Fe-CuNi -260 / 400 1°C ac current range (measurements of average value Type T IEC 584 , B IEC 584 400 / 1820 2°C 1.0°C PT100 temperature sensors Pt 30Rh-Pt 6Rh Remarks Accuracy


Original
PDF F16421 PT100 F16241 DPM 24 48 2000 d NICR-NIal thermocouple passive sensor DPM 24 96 DPM 160 DPM 24 40000 chromel IEC584 IEC 584 inductive load relays 48VDC
1998 - ph 4148

Abstract: n14148 ph 4148 f ph 4148 1n ICL76605 dpm 260-050 scr D106 temperature sensor with 7 segment display LM35 DPM45 digital thermometer using ic 7660 7805
Text: * DPM 200(S) DPM 300S DPM 400 * DPM 500S DPM 700 (S) DPM 2000(S) RS stock no. 257-212* 260-050/260-044 , DPM 116, 125, 400 , 500 V+ If we re-draw Figure 8(a) we will see that small impedances (Rs) in , 260-230 DPM 45 257-212/ 260-268 DPM 125/116 260-050 DPM 200 260-038 DPM 300S 260-274 DPM 400


Original
PDF 200mV 100mV) V/25mA V/50mA ph 4148 n14148 ph 4148 f ph 4148 1n ICL76605 dpm 260-050 scr D106 temperature sensor with 7 segment display LM35 DPM45 digital thermometer using ic 7660 7805
1997 - DPM 24 40000 mf

Abstract: DPM 24 96 24vac.230vac DPM 24 40000 thermal printer interface sample code NICR-NIal thermoelectric pt100 pin configuration PT100 temperature sensor DPM48 IEC584
Text: 400 V t 650 V t DC-V auto t AC-µ0.5 V t1V t5V t 10 V t 20 V t 50 V t 100 V t 500 V t 650 V , . Cond.) resolution -210 / 1200 1.5°C -200 / 900 1°C -260 / 400 1°C -200 , 1230 -50 1340 400 / / / / / / / / -50 0 1000 1230 1770 1340 1770 1820 2


Original
PDF
DPM 40

Abstract: DPM 3 1/2 BC237
Text: ) 40.0 (1.57) a 12.7 (0.50) b c d a. b. c. d. e. f. g. h. 2.00 6.00 1.60


Original
PDF 200mV 200mV August/1997 DPM 40 DPM 3 1/2 BC237
DPM 400

Abstract: DPM400 circuit logique facon
Text: ) (0.35) (0.15) (0.10) 2 1 e e. f. g. h. 0.50 5.00 1.60 4.00 3½-stelliges LCD-Modul , I Toutes les dimensions sont en mm (pouces) Découpe panneau 45 x 22,2 (1,77 x 0,87) DPM 400 , Specifications liable to change without prior warning DPM 400 Issue 3 November/1999 M.C. F Spécifications peuvent changer sans préavis DPM 400 Edition 3 novembre/1999 M.C. Applique à DPM 400 /7 D Die technischen Daten können ohne vorherige Ankündigung geändert werden DPM 400


Original
PDF novembre/1999 November/1999 DPM 400 DPM400 circuit logique facon