The Datasheet Archive

Top Results (5)

Part Manufacturer Description Datasheet Download Buy Part
CC3000YFVR Texas Instruments CC3000 126-DSBGA
PMP8012 Texas Instruments TPS92310 - 220VAC, 8W Isolated , Triac dimmable
LMT84LPC Texas Instruments ANALOG TEMP SENSOR-VOLTAGE, 2.70Cel, RECTANGULAR, SCREW MOUNT, THROUGH HOLE MOUNT, PLASTIC, TO-126, 3 PIN
LMT85LPC Texas Instruments LMT85 - SC70, Analog Temperature Sensor with Class-AB Output 3-TO-126 -50 to 150
LMT86LPC Texas Instruments ANALOG TEMP SENSOR-VOLTAGE, 2.70Cel, RECTANGULAR, THROUGH HOLE MOUNT, TO-126, 3 PIN

BT 126 TRIAC Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2008 - triacs BTA

Abstract: BC557 in smd package triac snubber ac motor SM1L43 triacs bt 12 Triac ACS108 controlling heater with triac washing machine drain valve types universal motor speed control wash ac motor control with triac
Text: can pose a particular challenge. NXP's BTA208X-1000C triac offers best-in-class performance in this , the AC mains supply. Each triac 's operation has to be mutually exclusive, to avoid uncontrolled , sinusoidal voltage (higher than the mains supply voltage), and the triac needs to be able to block the , inductor is not necessary The NXP BTA208X-1000C is the only three-quadrant Hi-Com triac to guarantee a , , motor speed varies widely. A triac is typically used to control the speed, via phase-control of the


Original
PDF
2007 - 1M preset

Abstract: triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control washing machine drain valve types induction heater microcontroller 100n N 250v X2
Text: and surface-mount options G+ The simple, reliable and inexpensive triac is used to control , Eliminates need for snubber circuit High dVD/dt Triac voltage Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC SNUBBER NOT REQUIRED Ñ igher dVcom/dt , commutation - Eliminates need for snubber circuit Triac voltage High dVCOM/dt Inductive load Three-quadrant triac 100 carbon composition resistor 100nF 250V AC Load Current SNUBBER NOT


Original
PDF BTA225 BTA225B 1M preset triac bt 13 h preset variable resistor 1m triac analog control for inductive loads 1M preset, horizontal L56R BT139 motor speed control washing machine drain valve types induction heater microcontroller 100n N 250v X2
2014 - Not Available

Abstract: No abstract text available
Text: TO -2 20A B BTA316-600BT 3Q Hi-Com Triac 5 August 2014 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT78 plastic package intended for use in circuits where high static and dynamic dV/dt and high dI/dt can occur. This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature without the aid of , - 16 A 2 - 50 mA full sine wave; Tmb ≤ 126 °C; Fig. 1; Fig. 2; Fig. 3


Original
PDF BTA316-600BT
triac BT 24

Abstract: triacs bt 138 TRIAC 138 triac BT 138 BT 138 bt138 triac BT 4 400 BT138-500 TRIAC TAG 90 triac BT 24 600
Text: N AMFR PHILIPS/DISCRETE b«ÌE T> bbsg'oi DD272n no hapx BT 138 SERIES X TRIACS , Respective Manufacturer I I N AMER PHILIPS/DISCRETE BT 138 SLKItb b^E T> bbSB^l 0D27HH0 'iOH MAPXl A , VDSM VDRM VDWM 'T(RMS) max-'TRM max- ■tsm 'tsm l2t BT 138- -500 600 700 800 max. 500* 600* 700 , , but the triac may switch into the on-state. The rate of rise of on-state current should not exceed 15 , Respective Manufacturer N AMER PHILIPS/DISCRETE BT 138 SLKItb blE » (^53^31 DD27252 70S «APX JL vT


OCR Scan
PDF DD272n bt138-500 220AB BT138 BT138F triac BT 24 triacs bt 138 TRIAC 138 triac BT 138 BT 138 triac BT 4 400 TRIAC TAG 90 triac BT 24 600
2010 - Not Available

Abstract: No abstract text available
Text: . This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature , BTA316-600BT 3Q Hi-Com Triac Rev. 02 — 30 November 2010 Product data sheet 1. Product profile 1.1 General description Planar passivated high commutation three quadrant triac in a SOT78 , - 140 A full sine wave; Tmb ≤ 126 ° C; see Figure 3; see Figure 1; see Figure 2 , 150 ° C - - 16 A BTA316-600BT NXP Semiconductors 3Q Hi-Com Triac Table 1


Original
PDF BTA316-600BT
2010 - triac BT 140

Abstract: triac BT 16 rating triac BT 06 400 triac BT 24 triac BT 12 rating BTA316 BTA316-600BT BT triac BT 140 triac
Text: . This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature , BTA316-600BT 3Q Hi-Com Triac Rev. 02 - 30 November 2010 Product data sheet 1. Product profile 1.1 General description Planar passivated high commutation three quadrant triac in a SOT78 , Conditions full sine wave; Tmb 126 °C; see Figure 3; see Figure 1; see Figure 2 Typ Max Unit - , 3Q Hi-Com Triac Table 1. Symbol Quick reference data .continued Parameter Conditions


Original
PDF BTA316-600BT triac BT 140 triac BT 16 rating triac BT 06 400 triac BT 24 triac BT 12 rating BTA316 BTA316-600BT BT triac BT 140 triac
BTi36

Abstract: TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 BT136 triac BT 06 700 PH 600D B 134 bt 136
Text: ) max- BT 136- -500 600 700 800 max. 500 600 700 800 'tsm 'tsm max. max. 25 30 V A A MECHANICAL DATA Fig , . ^Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , will not trigger any device; Tj = 120 °C; gate open circuit BT 136 series dVD/dt < 100 V/fis BT 136 series G dVD/dt < 200 V/jis BT 136 series F dVD/dt < 50 V/m s BT136 series E dVD/dt typ. 50 V , current {!(.) Latching current (![_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT136


OCR Scan
PDF 00bE23a BT136 BT136F d8573 BTi36 TRIAC BT 136 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 triac BT 06 700 PH 600D B 134 bt 136
triac BT 317

Abstract: BT 317 triac triac BT 06 600 triac BT 24 BT134 BT134-500D triac BT 06 400 triac BT 06 700 triacs BT 134 w triac BT 134
Text: N AMER PHILIPS/DISCRETE b^E T> m bbSa^Bl 002715b 1Ô7 HIAPX BT 134 SERIES y v. TRIACS , damage, but the triac may switch into the on-state. The rate of rise of on-state current should not , 1.8 A/ms; ¡T BT 134 series dVcom/dt typ. 10 V/fis BT 134 series G dVcom/dt < 10 V/jus BT 134 series F dVCom/dt typ. 10 V/a-s Off-state , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 002715b bt134-500 BT134G BT134 00271b5 BT134F triac BT 317 BT 317 triac triac BT 06 600 triac BT 24 BT134-500D triac BT 06 400 triac BT 06 700 triacs BT 134 w triac BT 134
2005 - TRIAC BTA 28

Abstract: TRIAC BTA 16 Triac BTB12 600 B TRIAC BTa 12 600 BW TRIAC BTA 02 triacs bta 100 600v TRIAC BTa 16 600 B BT 126 TRIAC TRIAC BTa 24 TRIAC BTA 16 600 BW
Text: -220AB package ORDERING INFORMATION BT A 12 - 600 BW (RG) TRIAC SERIES INSULATION: A , /BTB12 and T12 triac series is suitable for general purpose AC switching. They can be used as an ON/OFF , D²PAK/TO-220AB Tc = 90°C F = 50 Hz t = 20 ms 120 F = 60 Hz t = 16.7 ms 126 Non , CURRENT: 12A T 12 35 - 600 G PACKING MODE Blank: Bulk RG: Tube (-TR) TRIAC SERIES


Original
PDF BTA/BTB12 O-220AB BTA12) O-220AB BTB12) BW/CW/T1235) BW/CW/T1235 TRIAC BTA 28 TRIAC BTA 16 Triac BTB12 600 B TRIAC BTa 12 600 BW TRIAC BTA 02 triacs bta 100 600v TRIAC BTa 16 600 B BT 126 TRIAC TRIAC BTa 24 TRIAC BTA 16 600 BW
2014 - Not Available

Abstract: No abstract text available
Text: . This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature , TO -2 20F BTA420X-800BT 3Q Hi-Com Triac 5 June 2014 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT186A (TO-220F) "full pack , BTA420X-800BT NXP Semiconductors 3Q Hi-Com Triac Symbol Parameter Conditions Min Typ , 3Q Hi-Com Triac 7. Marking Table 4. Marking codes Type number Marking code BTA420X


Original
PDF BTA420X-800BT OT186A O-220F)
2014 - Not Available

Abstract: No abstract text available
Text: . This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature , TO -2 20F BTA410X-800BT 3Q Hi-Com Triac 28 May 2014 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT186A (TO-220F) "full pack , -800BT NXP Semiconductors 3Q Hi-Com Triac Symbol Parameter Conditions Min Typ Max Unit , BTA410X-800BT NXP Semiconductors 3Q Hi-Com Triac 7. Limiting values Table 4. Limiting values


Original
PDF BTA410X-800BT OT186A O-220F)
2013 - BTA420X-800BT

Abstract: No abstract text available
Text: "series BT " triac will commutate the full RMS current at the maximum rated junction temperature (Tj(max) = , BTA420X-800BT 3Q Hi-Com Triac 4 February 2013 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT186A (TO-220F) "full pack" plastic , this product TO -2 20F NXP Semiconductors BTA420X-800BT 3Q Hi-Com Triac Symbol IGT , / 13 NXP Semiconductors BTA420X-800BT 3Q Hi-Com Triac 7. Marking Table 4. Marking codes


Original
PDF BTA420X-800BT OT186A O-220F) BTA420X-800BT
2014 - Not Available

Abstract: No abstract text available
Text: . This "series BT " triac will commutate the full RMS current at the maximum rated junction temperature , TO -2 20F BTA410X-600BT 3Q Hi-Com Triac 28 May 2014 Product data sheet 1. General description Planar passivated high commutation three quadrant triac in a SOT186A (TO-220F) "full pack , -600BT NXP Semiconductors 3Q Hi-Com Triac Symbol Parameter Conditions Min Typ Max Unit , BTA410X-600BT NXP Semiconductors 3Q Hi-Com Triac 7. Limiting values Table 4. Limiting values


Original
PDF BTA410X-600BT OT186A O-220F)
triac BT 137

Abstract: triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 BT137 triac BT 137 600 triac BT 06 600 TRIAC TAG 91
Text: PHILIPS INTERNATIONAL bSE D 711GÖ2L, D0b2Ebl 27b HIPHIN BT 137 SERIES s V TRIACS Glass-passivated , BT 137 -500 600 700 800 max. 500 600 700 800 max. max. max. 55 60 V A A MECHANICAL DATA Fig.1 TOâ , either direction) BT 137-500 600 700 800 Non-repetitive peak off-state voltage (t < 10 ms)t VDSM max , without damage, but the triac may switch into the on-state. The rate of rise of on-state current should , the terminals does not exceed 125 °C. During these overload conditions the triac may lose control


OCR Scan
PDF 00b2271 BT137 M1Q41 BT137F D8573 M81-1647/1 triac BT 137 triac BT 137 800 philips d8614 BT 137 triac triac bt 135 bt 137 triac BT 137 600 triac BT 06 600 TRIAC TAG 91
1997 - triac BT 140

Abstract: 2kw TRIAC control triac burst control ic TRIAC BT 139 TRIAC 226 a triac 226 triac burst firing circuit triac applications circuit diagram BT 140 triac triac switch circuits
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
triac tag 87

Abstract: TRIAC BT 136 BT136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 D8384 bt136 triac triac BT 06 400
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , current (l|_j) Latching current (l[_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT > 35 H < 15 L <20 GT > 50 H < 30 L <30 GT H L > 25 < 15 < 20 GT H L > 10 , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose


OCR Scan
PDF 711Da2b 0Db523Ã BT136 BT136-500 M1625 BT136G 711002b 00b224Ã M1644 triac tag 87 TRIAC BT 136 working triac bt136 triac bt 135 BT 136 TRIAC TRIAC BT 136-500D TO220 D8384 bt136 triac triac BT 06 400
TRIAC BT 136

Abstract: BT 136 TRIAC BT136 working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
Text: - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136—500D/600D GT , the temperature of the terminals does not exceed 125 °C. During these overload conditions the triac , . on-state current based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may , IPHIN M 1 643 Fig.8 Typical commutation dV/dt for BT136 series versus Tj. The triac should commutate


OCR Scan
PDF 711Da2b 00bS23Ã BT136 BT136-500 711005b 00b224Ã M1644 BT136F D8573 TRIAC BT 136 BT 136 TRIAC working triac bt136 temperature control by triac BT136 triac bt 135 bt136 triac TRIAC TAG 90 BT136 motor BT136 application note
2013 - 1 kilo ohm resistor specifications

Abstract: RESISTOR 50 KILO OHM 2.2 kilo ohm resistor specifications
Text: GuardSwitch Series 300 Switches 301- BT and 303- BT Installation Sheet Figure 1: Dimensions Description The 301- BT Series 300 DPST safety interlock switch is designed for use with safety monitored relays or monitored circuits. To achieve the optimum Series 300 defeat resistant feature of the 301- BT , The housing of the 300- BT must be connected to the PE (Primary Earth) ground circuit via a lock , or nuts. See ordering information for details. Set range at 20 mega ohms (switches with triac


Original
PDF 301-BT 303-BT 301-BT, 73/23/EEC) EN60204-1 EN292 EN954-1 EN55081-2 EN50082-2 1 kilo ohm resistor specifications RESISTOR 50 KILO OHM 2.2 kilo ohm resistor specifications
triac bt 135

Abstract: triac BT 140 TAG 84 triac TRIAC BT 139 BT 139 F applications note bt 139 BT 140 triac BT139 triac BT 147 triac BT 24
Text: current 'T(RMS) Non-repetitive peak on-state current at 50 Hz ITS(V] at 60 Hz lTSM BT 139- -500 600 700 , (in either direction) BT 139- -500 600 700 800 Non-repetitive peak off-state voltage (t< 10 ms) VDSM , recommended, off-state voltages up to 800 V may be applied without damage, but the triac may switch into the , ; = 120 °C; gate open circuit 1.6 bt 139 series dVD/dt < 100 V/MS bt139 series G dVD/dt < 200 V/MS , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose


OCR Scan
PDF 711002b 00L23Q7 BT139 220AB triac bt 135 triac BT 140 TAG 84 triac TRIAC BT 139 BT 139 F applications note bt 139 BT 140 triac triac BT 147 triac BT 24
2007 - triac BT 16 rating

Abstract: BT 126 TRIAC triac BT 12 rating triac BT 140 triacs bt 12 BTA316 BTA316-600BT BT 140 triac triac bt 41 A
Text: BTA316 series BT 16 A Three-quadrant triacs high commutation high temperature Rev. 01 - 3 May , series BT NXP Semiconductors 16 A Three-quadrant triacs high commutation high temperature 3 , BTA316-600BT IT(RMS) RMS on-state current full sine wave; Tmb 126 °C; see Figure 4 and 5 , 800 V may be applied without damage, but the triac may switch to the on-state. The rate of rise of , reserved. Rev. 01 - 3 May 2007 2 of 12 BTA316 series BT NXP Semiconductors 16 A


Original
PDF BTA316 triac BT 16 rating BT 126 TRIAC triac BT 12 rating triac BT 140 triacs bt 12 BTA316-600BT BT 140 triac triac bt 41 A
2002 - Not Available

Abstract: No abstract text available
Text: surface-mount packages, the BTA/BTB12 and T12 triac series is suitable for general purpose AC switching. They , -220AB Tc = 90°C F = 50 Hz t = 20 ms 120 F = 60 Hz t = 16.7 ms 126 78 tp = 10 ms , BTA/BTB12-xxxBW BTB: non insulated TO-220AB package ORDERING INFORMATION BT A 12 - 600 BW (RG) TRIAC SERIES INSULATION: A: insulated B: non insulated SENSITIVITY & TYPE B , : Tube (-TR) TRIAC SERIES PACKAGE: G: D2PAK CURRENT: 12A VOLTAGE: 600: 600V 800: 800V


Original
PDF BTA/BTB12
2001 - BT 130 triac

Abstract: triacs bt 12 600v BT 126 TRIAC triac BTA 32 600 bt 1690 triac BTA12 triacs bt 12 800v
Text: ORDERING INFORMATION BT A 12 TRIAC SERIES INSULATION: A: insulated B: non insulated CURRENT: 12A 600 , DESCRIPTION Available either in through-hole or surface-mount packages, the BTA/BTB12 and T12 triac series is , ) Value Tc = 105°C 12 Tc = 90°C t = 20 ms t = 16.7 ms 120 126 78 Tj = 125°C Tj = 25°C Tj = 125°C Tj = 125 , : 10mA LOGIC LEVEL VOLTAGE: 600: 600V 800: 800V T 12 35 TRIAC SERIES CURRENT: 12A - 600 G


Original
PDF BTA/BTB12 BT 130 triac triacs bt 12 600v BT 126 TRIAC triac BTA 32 600 bt 1690 triac BTA12 triacs bt 12 800v
2005 - triac bta12 triggering

Abstract: BTA12 600V bta12 speed control application Triac BTB12 600 B BTA12 interface with ac motor bta12 phase control application BTA12 Application note TRIAC BTA-SERIES TRIAC BTB12 600 Triac BTA 12A 600 V
Text: Information Scheme (BTA and BTB series) BT A 12 - 600 BW RG Triac series Insulation A = insulated B = , or surface-mount packages, the BTA12, BTB12 and T12 triac series is suitable for general purpose AC , ms 126 tp = 10 ms Average gate power dissipation 78 A²s Tj = 125°C 50 A/µs , 12 35 - 600 G (-TR) Triac series Current 12 = 12A Sensitivity 35 = 35mA 05 = 5mA Voltage 600


Original
PDF BTA12, BTB12 triac bta12 triggering BTA12 600V bta12 speed control application Triac BTB12 600 B BTA12 interface with ac motor bta12 phase control application BTA12 Application note TRIAC BTA-SERIES TRIAC BTB12 600 Triac BTA 12A 600 V
2005 - triacs bt 12 600v

Abstract: BTA12 interface with ac motor BTA12 600V BT 130 triac bta12 triac motor Triac BTB12 600 B triac bt 136 TRIAC BTB 16 600 tube TRIAC BTB12 600 TRIAC BTB 16 600 BW
Text: or surface-mount packages, the BTA12, BTB12 and T12 triac series is suitable for general purpose AC , 126 tp = 10 ms Critical rate of rise of on-state current IG = 2 x IGT , tr 100 ns 120 t = , BTA12, BTB12 and T12 Series Figure 13: Ordering Information Scheme (BTA and BTB series) BT A 12 - 600 BW RG Triac series Insulation A = insulated B = non insulated Current 12 = 12A Voltage 600 , Figure 14: Ordering Information Scheme (T12 series) T 12 35 - 600 G (-TR) Triac series Current 12 =


Original
PDF BTA12, BTB12 triacs bt 12 600v BTA12 interface with ac motor BTA12 600V BT 130 triac bta12 triac motor Triac BTB12 600 B triac bt 136 TRIAC BTB 16 600 tube TRIAC BTB12 600 TRIAC BTB 16 600 BW
1995 - triac BT 140

Abstract: triac burst control ic 2kw TRIAC control ac voltage stabiliser circuit diagram ramp generator triac BT 139 TRIAC 226 a stabiliser circuit diagram triac applications circuit diagram 443A
Text: requirement the value of tp can be calculated. eg. for triac BT 139 (data sheet 2488) worst case holding , number 307-985 A zero voltage switch IC offering symmetrical burst control of an external triac , triac firing under noisy mains conditions q Low external component count q Symmetrical burst control , °C unless otherwise stated Parameter Pin 3 voltage Supply current, I2 Rp resistance range Triac gate , Total power dissipation Conditions I = 16mA Excluding triac trigger pulse and pin 5 output total


Original
PDF
Supplyframe Tracking Pixel