The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LM8502TMX/NOPB Texas Instruments Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Drive 30-DSBGA -30 to 85
LM8502TME/NOPB Texas Instruments Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Drive 30-DSBGA -30 to 85
TPS259823LNRGET Texas Instruments 15A, 2.7mΩ smart eFuse with accurate load current monitor and adjustable transient fault management
TPS259824LNRGET Texas Instruments 15A, 2.7mΩ smart eFuse with accurate load current monitor and adjustable transient fault management
TPS259822LNRGET Texas Instruments 15A, 2.7mΩ smart eFuse with accurate load current monitor and adjustable transient fault management
TPS259823ONRGET Texas Instruments 15A, 2.7mΩ smart eFuse with accurate load current monitor and adjustable transient fault management

BS88 63A fuse curve Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2008 - BS88 32A fuse

Abstract: No abstract text available
Text: General Purpose Fuses IEC General Purpose Fuses IEC BS88 -2 Fuses gG/gM Sizes F1,F2 •The fuse comply with standard EN 60269-2 section II and standard BS88 part 2. •This fuses are designed for : - “general purpose use” protection, (gG type) - motor protection (gM type) •This fuse , and can be connected with clips. F1,F2 types - gG curve Applications Features /Benefits • • • • • • • • • • • • • • Compact design Curve gG and gM


Original
PDF BS88-2 88-part GPEU102 BS88 32A fuse
CM100F

Abstract: bussmann hrc fuse bs88 part 4 RS63H RS100H SC32H 32NNL RS32PH bussmann hrc fuse bs88 part 5 RS20P RS20H
Text: Circuit Protection Solutions CAMASTER and SAFELOC BS88 Fuseholders Product Guide CAMASTER & SAFELOC BS88 Fuseholders product guide Safeloc HRC Fuseholder - 660V ac: 32A - 63A NNS, ENS Features & , to use with BS88 Fuse links for bolted panel mounting or DIN rail. Dimensions: See Dimensions illustrations Ratings: Volts: -550Vac, 415V ( 63A ) Amps: -32, 63A Agency information: CE, Compliance to BS88 , fuse bases with unique cam action system for BS88 Fuse link applications Dimensions: See Dimensions


Original
PDF
16GD27

Abstract: bussmann hrc fuse bs88 part 5 bussmann hrc fuse bs88 part 4 BS88 fuse NH3 630A 63a17 fuse n15 COOPER BUSSMANN C4545 Fuse BS1361 NH Bussmann fuse GG 690v 50A
Text: 30 M-BAO63 63A 550V BS88 Fuse 3 30 M-CD100 100A 550V BS88 Fuse 3 30 , BS88 Fuse 3 30 M-32NNSF 32A Safeloc Fuseholder 1 5 M-63ENSF 63A Safeloc , Fuse Links 4 Industrial & Motor Applications to BS88 Offset Bolted Tags 5-7 Centre Bolted , Cut-Out Fuse Links 17 J Type Fuse Links to BS88 : Part 5 Cylindrical 17 J Type Fuse Links to , www.cooperbussmann.com Low Voltage Fuse Links Catalogue Industrial & Motor Applications to BS88 Ratings: Offset


Original
PDF BS1361 BS1312 500Vdc 660/690V LV-2007 16GD27 bussmann hrc fuse bs88 part 5 bussmann hrc fuse bs88 part 4 BS88 fuse NH3 630A 63a17 fuse n15 COOPER BUSSMANN C4545 Fuse BS1361 NH Bussmann fuse GG 690v 50A
1997 - telemecanique contactor catalogue

Abstract: telemecanique star delta starter bs88 zs levels HRC fuse gg GEC 15KW motor BS88-2 telemecanique star delta starter table BS88 fuse curve hbc NIT16 gec mte axto overload
Text: (Zs). Table 41A2 in the Regulations specifies values of Zs for HBC fuse links to BS88 : Part 2: 1975 , Issued March 1997 232-3608 Data Pack B Data Sheet BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88 : Part 2: 1975, suitable for general purpose industrial applications (eg , revisions of BS88 : Parts 1 and 2). *HBC (High Breaking Capacity) is sometimes denoted as HRC (High , dissipation; values well within the limits of BS88 : Part 2, allowing associated equipment to run cool and to


Original
PDF IEC269: RS20H RS32H RS63H RS100H telemecanique contactor catalogue telemecanique star delta starter bs88 zs levels HRC fuse gg GEC 15KW motor BS88-2 telemecanique star delta starter table BS88 fuse curve hbc NIT16 gec mte axto overload
2009 - star delta FORWARD REVERSE STARTER

Abstract: BS88-6 100AXTN2 gec switchgear BS5419 automatic star delta starter using timer 100KXTNC2F wiring diagram for single phase dol motor starter IEC 60269 SIBA HRC fuse gg GEC
Text: cartridge fuse links to BS88 : Part 2. 63A and 100A units employ off-set contact fuse links. Details of , secondary cover allows access to switch and fuse carrier. Designed for offset contact fuselinks to BS88 , BS88 ­ 6 with ratings from 2 to 63A for use in industrial and commercial installations. 550V a.c. S , capacities for Type A and Type B bases:- 20A 6mm2, 32A 10mm2, 63A 35mm2, 100A 70mm2. Rewirable fuse carriers , connecting stud at the other. Fuse units have been ASTA certified to BS88 ­ 2 and are suitable for systems


Original
PDF PG01900001U star delta FORWARD REVERSE STARTER BS88-6 100AXTN2 gec switchgear BS5419 automatic star delta starter using timer 100KXTNC2F wiring diagram for single phase dol motor starter IEC 60269 SIBA HRC fuse gg GEC
1995 - telemecanique contactor catalogue

Abstract: telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve
Text: (Zs). Table 41A2 in the Regulations specifies values of Zs for HBC fuse links to BS88 : Part 2: 1975 , Issued March 1992 012-659 Data Pack B Data Sheet BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88 : Part 2: 1975, suitable for general purpose industrial applications (eg , revisions of BS88 : Parts 1 and 2). *HBC (High Breaking Capacity) is sometimes denoted as HRC (High , dissipation; values well within the limits of BS88 : Part 2, allowing associated equipment to run cool and to


Original
PDF IEC269: RS20H RS32H RS63H RS100H telemecanique contactor catalogue telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve
1992 - telemecanique contactor catalogue

Abstract: HRC fuse gg GEC telemecanique thermal overload relay tripping curve telemecanique star delta starter mte thermal overload relay mte axto overload mte relay BS88 gM motor fuse what is type 2 coordination TIA16
Text: current which causes the s HBC fuse links to BS88 : Part 2: 1975 which are smaller or 'minor' fuselink to , Issued March 1992 B12659 BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88 : Part , also the l ASTA certified in combination with motor control pending revisions of BS88 : Parts 1 and 2). , quick response to fault conditions l Low power dissipation; values well within the limits of BS88 : Part , voltage fuse link indicates that the design has been successfully tested and certified by ASTA to the


Original
PDF B12659 IEC269: RS20H RS32H RS63H RS100H RS200H RS20H RS32H RS63H telemecanique contactor catalogue HRC fuse gg GEC telemecanique thermal overload relay tripping curve telemecanique star delta starter mte thermal overload relay mte axto overload mte relay BS88 gM motor fuse what is type 2 coordination TIA16
2008 - bussmann Fuse 450 amps 250 volts max zs

Abstract: bs88 zs levels BS88 gM motor fuse bs 88 max zs values 400SN11 800SR11 bussmann Fuse 1000 amps 440 volts 63KO7-660 35KO7-660 ASTA20
Text: capacity - 33KA. @- Rated upto 125A only Note : Bussmann offers some more LV BS88 type fuse to meet the , BS88 are : Rating (A) Zs Ohms Rating (A) Zs Ohms MOTOR CIRCUITS In motor circuits the fuse link has , performed with the latest gG or gM fuse links, to BS88 or IEC60269 which have pre-arcing I2 t values toward , `08 Low Voltage Fuses BS Type Low Voltage Fuse - BS Type Table of Contents Range & Selection Table 2 Industrial & Motor Applications to BS88 Offset Bladed Tags - 550V/415V/240V Offset


Original
PDF 50V/415V/240V 50V/415V 660/690V CBIL/BSLV-R4/1-2008/L1-3000 bussmann Fuse 450 amps 250 volts max zs bs88 zs levels BS88 gM motor fuse bs 88 max zs values 400SN11 800SR11 bussmann Fuse 1000 amps 440 volts 63KO7-660 35KO7-660 ASTA20
2008 - BS88 gM motor fuse

Abstract: FUSELINK TO BS88 PART 1 A226320
Text: BS88 -2 Fuses gG/gM Sizes A,B,C Standard fuse ampere rating A, B and C types - gG curve A type , Purpose Fuses IEC BS88 -2 Fuses gG/gM Sizes A,B,C A and B types - gM curve A type Type Rating , General Purpose Fuses IEC General Purpose Fuses IEC BS88 -2 Fuses gG/gM Sizes A,B,C • The fuse complies with standard EN 60269-2 section II and standard BS 88 part 2. • These fuses are , fuse range insures an excellent current limitation for all overloads on a large range of applications


Original
PDF BS88-2 GPEU99 BS88 gM motor fuse FUSELINK TO BS88 PART 1 A226320
HRC fuse gg GEC

Abstract: GEC Alsthom HRC GEC Alsthom bs88 PART 2 Type T 3 phase, 415v and 270 kw motor GEC Alsthom 32M35 321 tlt 149 bs88 zs levels TXU1000 TKF315
Text: TXU1250 BS88 1988 Dimensional Ref. D1 Some of the fuse link types used in some , , direct on line motor circuit, instead of 63A gG fuse links in 63A fuseholders, because although the motor starting surge requires the use of fuse links with 63A time/current characteristics, the motor FLC is less , associated equipment. BS88 Part 1: 1988 states that fuse links experience fault currents which produce , ) of the Regulations specifies values of Zs when fuse links to BS88 :Part 2:1988 are used. These are


OCR Scan
PDF 20M25 20M32f NIT16 NIT20 20M25 NIT20M25t 20M32 NIT20M32f 32M35-32M63f 630M670 HRC fuse gg GEC GEC Alsthom HRC GEC Alsthom bs88 PART 2 Type T 3 phase, 415v and 270 kw motor GEC Alsthom 32M35 321 tlt 149 bs88 zs levels TXU1000 TKF315
1991 - bs88 fuse

Abstract: B1192 fuse bs88 fuse base IEC 269
Text: Issued July 1991 B11921 Camaster BS88 fuseholders RS stock numbers 20A 418-451, 32A 418-467 63A 418-473, 100A 418-489 A range of fully shrouded, front connected HRC fuse Features holders with enhanced performance characteristics l Unique cam action fuse carrier removal which comply with the requirements of BS88 :1988 and l IEC 269:1986. DIN rail or back panel mounting l The unique cam lever action of the fuse carrier allows Hinged internal shields ensure that terminal shields easy removal from the fuse


Original
PDF B11921 bs88 fuse B1192 fuse bs88 fuse base IEC 269
1997 - fuse base IEC 269

Abstract: IEC 269 BS88 32A fuse
Text: Issued March 1997 232-3462 Data Pack B Data Sheet Camaster BS88 fuseholders RS stock numbers 20A 418-451, 32A 418-467 63A 418-473, 100A 418-489 A range of fully shrouded, front connected HRC fuseholders with enhanced performance characteristics which comply with the requirements of BS88 :1988 and IEC 269:1986. The unique cam lever action of the fuse carrier allows easy removal from the fuse box. The fuse cover has also been designed to give excellent contact pressure between fuse


Original
PDF
1995 - IEC 269

Abstract: BS88 A fuse bs88 HRC FUSE 20A
Text: Issued July 1991 011-921 Data Pack B Data Sheet Camaster BS88 fuseholders RS stock numbers 20A 418-451, 32A 418-467 63A 418-473, 100A 418-489 A range of fully shrouded, front connected HRC fuseholders with enhanced performance characteristics which comply with the requirements of BS88 :1988 and IEC 269:1986. The unique cam lever action of the fuse carrier allows easy removal from the fuse box. The fuse cover has also been designed to give excellent contact pressure between fuse


Original
PDF
1998 - K07-660

Abstract: BS88 fuse curve
Text: Bussmann Industrial HRC Fuse Links 660V Range Offset Bolted Tags Time-Current Characteristic Curve ® BS88 , IEC269 K07-660 40A 50A 63A Offset Bolted Tag Dimensional Data Carton Quanities: All K07 range are packed in 20's Ordering Code: Rating followed by K07-660 I t (Ampere Seconds) Catalog Number K07-660 K07-660 K07-660 Amp PreRatings Arcing 40 50 63 3,400 Total at 415V 7,100 Total at 550V Total at 660V 2 2 Nom. Rated Watts Voltage Loss 4.0 4.8 5.7 660V ac 250V dc Dimensions


Original
PDF IEC269 K07-660 K07-660 BS88 fuse curve
1998 - K08-660

Abstract: BS88 fuse curve HRC Fuse 250V 20A 20A BS88 fuse curve
Text: Bussmann Industrial HRC Fuse Links 660V Range Centre Bolted Tags Time-Current Characteristic Curve ® BS88 , IEC269 K08-660 10A 16A 20A 25A 32A 40A 50A 63A Centre Bolted Tag 2A 4A 6A Dimensional Data Carton Quantities: All of the K08 range are packed in 20's Ordering Code: Rating followed by K08-660 Catalog Number K08-660 K08-660 K08-660 K08-660 K08-660 K08-660 K08-660 K08-660 K08-660 K08-660 K08-660 I2t (Ampere2 Seconds) Amp Pre- Total at Total at Total at Ratings Arcing


Original
PDF IEC269 K08-660 K08-660 BS88 fuse curve HRC Fuse 250V 20A 20A BS88 fuse curve
2013 - 8DB0056-001

Abstract: TAG 203 350 RS63H neutral link RS20HWH 5SE200 TLU 315 NS16M20 TLU800 F076802 RSL63H
Text: Form 101 Safeclip Fittings Industrial Fuse Links BS88 Clip-in BS88 Bolt-in 415 - 660V DIN , Fuse Links & Fittings BS88 J Type 415V Series 7 Fittings Porcelain Overhead Fittings Outdoor , Protection 200 MV Fuse Links & Accessories DIN NH 1200V Blade BS88 1200V Bolt-in IEC Ferrule 1500V , 5 HRC BS TYPE CLIP-IN FUSE LINKS 415V BS88 CLIP IN FUSES - SS Features: - Standards: ASTA20 , -2-1, 415V AC. - DIN Rail mounting. SAFECLIP FUSE FITTINGS UP TO 63A Rating Amp Colour: Black To


Original
PDF 500/660V 500/690V BS2692-1975. AS1033-2 254mm 359mm 8DB0056-001 TAG 203 350 RS63H neutral link RS20HWH 5SE200 TLU 315 NS16M20 TLU800 F076802 RSL63H
HRC fuse d type

Abstract: CM63F 100 HRC fuse 32LSC HRC FUSE 20A 32LSCC 80 HRC fuse bussmann hrc fuse holders CM20F CAMASTER
Text: CAMASTER HRC Fuse Holders Bussmann ® A patented range of fully shrouded HRC Fuse Holders designed to accommodate offset bolted tag HRC fuse links to BS88 : Parts 1 & 2; IEC 269-1 & 2. The compact dimensioned 32A Fuse Holder, type CM32FC accepts the A1 size fuse link NITD 2 to 32 Amps. The standard 32A fuse holder, type CM32F accepts the A2 size fuse link AAO - 2 to 32Amp. The 63A unit, type CM63F, accepts the A3 size fuse link BAO - 40 to 63 Amp and the 100A unit, type CM100F, accepts fuse


Original
PDF CM32FC CM32F 32Amp. CM63F, CM100F, 32BSC 63/100BS 90-660NI 32LSCC 32LSC HRC fuse d type CM63F 100 HRC fuse 32LSC HRC FUSE 20A 32LSCC 80 HRC fuse bussmann hrc fuse holders CM20F CAMASTER
1998 - ESD63M80

Abstract: bussmann hrc fuse holders esd63 HRC FUSE 20A IEC269 gG bussmann hrc fuse 25A bussmann Fuse 40a 63M100 bussmann hrc fuse bs88 the t.amp 1500
Text: Bussmann® BS88 , IEC269 Industrial HRC Fuse Links ESD Offset Blade Tags 550V ac and 415V ac Time-Current Characteristic Curves Non Motor Rated Motor Rated 16A 20A 25A 32A 40A 50A 63A 63M80 63M100 2A 4A 6A 10A Dimensional Data The ESD range of Fuse Links comply with general purpose gG characteristics and fit into the SAFELOC Fuse Holders and into the CAMLOC Distribution Fuseboard System. Packaging - 20 per carton 2 Catalog' Number I t (Amp2 Seconds) Amp


Original
PDF IEC269 63M80 63M100 ESD63M80 bussmann hrc fuse holders esd63 HRC FUSE 20A IEC269 gG bussmann hrc fuse 25A bussmann Fuse 40a 63M100 bussmann hrc fuse bs88 the t.amp 1500
mccb 60947-2 max zs

Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram ADA925U HMF280T
Text: Miniature Circuit Breakers Curve B,C & D : BS EN 60898 : 10 kA and BS EN 60947-2 : 15kA In 0.5 to 63A , Curve NCNxxxA : "C" Curve NDNxxxA : "D" Curve In 0.5 to 63A Un : 230V-400V Will accept accessories , auxiliaries 3.17 RCBO single pole 3.18 RCBO single pole and switched neutral 3.19 HRC fuse , Devices Miniature circuit 3.2 breakers 6kA type B SP Miniature circuit 3.3 breakers curve B , NBNxxxA : "B" Curve NCNxxxA : "C" Curve NDNxxxA : "D" Curve Designation Pack qty Cat ref


Original
PDF 0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram ADA925U HMF280T
mccb 60947-2 max zs

Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram IEC 60947-2 max zs HD148U HN204
Text: Miniature Circuit Breakers Curve B,C & D : BS EN 60898 : 10 kA and BS EN 60947-2 : 15kA In 0.5 to 63A , Curve NCNxxxA : "C" Curve NDNxxxA : "D" Curve In 0.5 to 63A Un : 230V-400V Will accept accessories , auxiliaries 3.17 RCBO single pole 3.18 RCBO single pole and switched neutral 3.19 HRC fuse , Devices Miniature circuit 3.2 breakers 6kA type B SP Miniature circuit 3.3 breakers curve B , NBNxxxA : "B" Curve NCNxxxA : "C" Curve NDNxxxA : "D" Curve Designation Pack qty Cat ref


Original
PDF 0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram IEC 60947-2 max zs HD148U HN204
mccb 60947-2 max zs

Abstract: MCB ENERGY LET THROUGH mcb technical detail mcb tripping curves b112c HRC fuse gg GEC 80A mccb curve NSB310-C Wylex 604 400a mccb
Text: 10kA 10A 10kA 16A 10kA 20A 10kA 32A 10kA 40A 10kA 50A 10kA 63A 10kA POLES B CURVE C , Terminals up to 10mm2 4 Core * Spreading room NH FUSE COMBINATION UNIT 63A-125A 63A SP&N TP&N , NSB40 NSB50 6A 10A 16A 20A 32A 40A 50A 20 20 10 BS88 FUSE 160A sec 6 .01 1 , . MAIN SWITCH CAT REF MCB WAYS 40A 63A 100A 100A 100A 100A 100A 2 2 5 8 11 14 19 , NHRM1404 NHRM1904 40A 30mA 63A 30mA 100A 30mA 100A 30mA 100A 30mA 100A 30mA 100A 30mA 40A 100mA


Original
PDF
2000 - 194r-hs4e

Abstract: 195-GA10 194R-NJ100P3 194R-NJ030P3 194R-NJ200P3 hs4e IEC 947 EN60947 allen-bradley Bulletin 100 194R-NC030P3 194R-AA
Text: , British Standard BS88 and DIN ­ A fuse for nearly every application. 2 Reliability Accessories , Fuse Type/Size UL/ Class J (max size) 30A UL /CSA Class CC 60A 30A BS88 A1 A1 A3 , 230VDC Fuse Type/Size UL/ Class J (max size) 200A 400A BS88 DIN B1,B2 O,OO,COO CSA , fused or non-fused styles. Non-fused styles permit use of your own fuse blocks. Fused switches, with integral fuse carriers reduce panel space requirements while shortening wiring time and reduce cost. Some


Original
PDF 194R-NN600P* 194R-NN800P* 194R-SG001A-US-P 194r-hs4e 195-GA10 194R-NJ100P3 194R-NJ030P3 194R-NJ200P3 hs4e IEC 947 EN60947 allen-bradley Bulletin 100 194R-NC030P3 194R-AA
mw 137 600g

Abstract: transistor 5cw 069UR1S0250B bs88-4 070US3U1400B 110UR2S0800B transistor 6cw transistor 5cw 61 069UR1S0350B IXYS CATALOGUE
Text: Power Curve enabling calculation of dissipated power P by a fuse rated IN, as a function of the RMS , accordance with working voltage U. Curve indicating peak arc voltage Um which may appear across fuse , American Square Body Fuse ­ Short Blades Corrective Factor ­ Peak Arc Voltage: The above Mean curve , working voltage U. Curve indicating peak arc voltage Um which may appear across fuse terminals as a , FUSES Contents 1. Introduction 2 2. Applications & Definitions 2 3. Fuse


Original
PDF
2003 - mccb 60947-2 max zs

Abstract: memshield 2 MFL1003 bs88 zs levels Eaton MCB 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram dol motor starter 18000 rpm DC motor project on dol starter wiring Eaton 60947-2 mccb
Text: or fuses upstream of it (see example 2). EXAMPLE 2 UPSTREAM BS88 Fuse Moulded case or , increase between the upstream and downstream breakers. 6 EXAMPLE 3 A 32SB3 Eaton MEM HRC fuse curve , curve (0.1 sec current) or as in Fig. 3 where the fuse curve crosses the MCB curve . Fig 3 shows that a , circuit levels for products in chart 2. CHART 2 UPSTREAM DOWNSTREAM BS88 Fuse Moulded case or , information for Eaton MEMs BS88 HRC fuse range can be extracted from curves and is presented in tabular form


Original
PDF
1998 - BD50

Abstract: bussmann hrc fuse bs88 bussmann hrc fuse bussmann Fuse 40a IEC269 BD63 BD40 BD03 bussmann bd039
Text: Bussmann ® BS88 , IEC269 Industrial HRC Fuse Links BD Centre Bolted Tags 550V ac 250V dc Time-Current Characteristic Curves Non Motor Rated 40A 50A 63A Centre Bolted Tag Dimensional Data Catalog' Number I2t (Amps2 Seconds) Nom. Rated Amp PreTotal at Watts Voltage Loss Ratings Arcing 415V BD40 40 1400 3600 4.7 BD50 50 3000 8000 4.9 BD63 63 6700 18,800 5.6 Dimensions (mm) A B C 550 ac 128.5 111.0 55.0 250 dc D


Original
PDF IEC269 BD50 bussmann hrc fuse bs88 bussmann hrc fuse bussmann Fuse 40a IEC269 BD63 BD40 BD03 bussmann bd039
Supplyframe Tracking Pixel