The Datasheet Archive

Top Results (1)

Part Manufacturer Description Datasheet Download Buy Part
LP5907SNE-4.5/NOPB Texas Instruments 4.5V FIXED POSITIVE LDO REGULATOR, 0.25V DROPOUT, PDSO4, PLASTIC, X2SON-4
SF Impression Pixel

Search Stock (1)

  You can filter table by choosing multiple options from dropdownShowing 1 results of 1
Part Manufacturer Supplier Stock Best Price Price Each Buy Part
B7A(NE45)-10PK SPC Multicomp Newark element14 14 $18.69 $11.06

No Results Found

Show More

B7A(NE45)-10PK Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1998 - NE-2D

Abstract: NE2J ne2d c9a lamp 387 LAMP neon lamp 220 volt Neon Lamp T-2 Midget Midget 521-9048
Text: B7A ( NE-45 ) F4A (NE-58) 105­125 210­250 2.0 2.0 30K 100K 1/4 1/3 5,000 5,000 T


Original
PDF NE-51) NE-51H) NE-45) 12PSB 24PSB 28PSB 48PSB 60PSB 120PSB NE-2D NE2J ne2d c9a lamp 387 LAMP neon lamp 220 volt Neon Lamp T-2 Midget Midget 521-9048
B7A NE-45

Abstract: NE-57 B6A NE-21 NE-48 ne57 21NE21
Text: C h ic a g o W HERE INNOVATION COM ES TO LIG H T M 1080 Johnson Drive Buffato Grove, IL 60089 iniature 708-459-3400 Fax 708-459-2708 Neon Indicator Lamps Design Current mA Maximum Breakdown Voltage VAC VDC Configuration T-41/2 Candelabra Screw Base Part Number Old Ref. Number B7A NE-45 NE-57 NE-58 AR-3 2.0 2.0 2.0 65 65 65 80 90 90 90 115 (toon Produett F3A F4A J2A 3.5 S- \ T-41/2 S.C. Bayonet Base "- A ^ B6A B8A NE-21 NE-47 2.0 2.0


OCR Scan
PDF T-41/2 NE-45 NE-57 NE-58 NE-21 NE-47 NE-17 NE-48 B7A NE-45 B6A NE-21 NE-48 ne57 21NE21
7153AS15

Abstract: NE-2 neon ne51hr NE2J 749-1396 lamp ne2 749-9323 NE-2H B1A NE-51 c2a neon
Text: /4 21 T-1 3 /4 2.05 — 749-2163 B7A ( NE-45 ) 2.00 30.0 K 1 /4 23 T-4 1 /2 4.02 — Prices Subject To


Original
PDF NE-51) NE-51H) NE-51HR) NE-45) 7153AS15 NE-2 neon ne51hr NE2J 749-1396 lamp ne2 749-9323 NE-2H B1A NE-51 c2a neon
NE-2 neon

Abstract: NE38 neon A9AC Neon Lamp A9A Neon Lamp A3C NE2J lamp ne2 Neon NE-51 NE-2e neon Neon Lamp a2b
Text: Breakdown Voltage VAC VDC Neon Products -*·-A - i r . B7A F3A F4A NE-45 NE-57 NE-58 AR


OCR Scan
PDF NE-38S NE-38 100VAC. NE-2 neon NE38 neon A9AC Neon Lamp A9A Neon Lamp A3C NE2J lamp ne2 Neon NE-51 NE-2e neon Neon Lamp a2b
Neon Lamp A9A

Abstract: Neon Lamp 2ml B6A NE-21 Neon Lamp a2b 715AS15 NE-2D ne51hr 56PR200 55-112R-0 6S6DC-120V
Text: -51H) B2A-R(NE-51HR)* B7A ( NE-45 ) B5A(NE-17) B9A(NE-48) J5A(NE-30) J9A(NE-56)* *For 220-250 Volts


Original
PDF NE-21) NE-38S) Neon Lamp A9A Neon Lamp 2ml B6A NE-21 Neon Lamp a2b 715AS15 NE-2D ne51hr 56PR200 55-112R-0 6S6DC-120V
513 CAP SERIES DIALIGHT

Abstract: 911-1112-525 6S6DC-30V 6S6-125V 554-1121-211 32NS-2A neon light holders 812-1030-09-506 513-0301-604 6S6DC-24V
Text: WATTS LIFE HOURS 521-9051 B7A ( NE-45 ) F4A (NE-58) 105­125 210­250 2.0 2.0 30K 100K , 103-3114-05-103 105­125 210­250 521-9051 ( B7A ) 521-9055 (F4A) 13 13 Uses: T 4 1/2 CANDELABRA


Original
PDF 6S6-12V 6S6-24V 6S6-30V 6S6-48V 6S6-75V 6S6-125V 6S6-135V 6S6-145V 10S6-230V 513 CAP SERIES DIALIGHT 911-1112-525 6S6DC-30V 6S6-125V 554-1121-211 32NS-2A neon light holders 812-1030-09-506 513-0301-604 6S6DC-24V
2000 - Not Available

Abstract: No abstract text available
Text: 9 Technical Reference Data B7A The following information applies to all B7A Series Link Modules 1 Connecting B7A to a programmable 1 Signal configuration examples for inputs controller and outputs 1 Peripheral circuits of printed circuit 1 1 1 1 board B7A models 1 Noise , Precautions Recommended cables Mounting guidelines Operation 3 CONNECTING B7A TO A PROGRAMMABLE CONTROLLER Each terminal of the B7A should be used for only single signal transmission without a


Original
PDF 1-800-55-OMRON
2011 - B7A-R3A33-M

Abstract: B7A-R6A52 B7AP b7ar
Text: B7AP Power Coupler between the B7A Input Unit and B7A Output Unit, it is possible to transmit multiple , between Power Couplers without contact is 8±1.5 mm. The maximum transmission distance between the B7A Input Unit and B7A Output Unit is 100 m (when transmitting power or signals). 8±1.5 mm B7A Output Unit B7A Output Unit Signal B7A Input Unit B7A Input Unit B7AP-S1 Power PLC or other controller , power and transmission signals, a maximum of 10 points can be input simultaneously to the B7A Input Unit


Original
PDF
2000 - B7AT6C1

Abstract: B7A-R6A52 B7A-R6A57 B7AT6C6 B7AS-T6B1 C200H-B7A22 B7AT6B1 B7A-R6F31 B7A-T6D2 B7AS-R6B36
Text: input signals over just 2 wires (3 wires if only one terminal has a power supply) B7A /B7AS 1 , Printed circuit board model B7A /B7AS 3 16-POINT LINK MODULES Screw Terminal Models Appearance I/O , HOLD LOAD OFF HOLD LOAD OFF HOLD LOAD OFF HOLD LOAD OFF B7A /B7AS Part number NPN compatible , FET open drain output 2 B7A /B7AS Printed Circuit Board Models Appearance I/O classification , ) -HOLD/LOAD OFF selected l t d by b wiring ii B7A /B7AS Part number B7A-T6D2 B7A-T6D7 B7A-R6A52


Original
PDF 16-point 1-800-55-OMRON B7AT6C1 B7A-R6A52 B7A-R6A57 B7AT6C6 B7AS-T6B1 C200H-B7A22 B7AT6B1 B7A-R6F31 B7A-T6D2 B7AS-R6B36
2008 - CJ1W-B7A22

Abstract: OMRON cj1 wiring cJ1 OMRON CJ1W -SCU41-V1 CJ1W-B7A14 CJ1W-B7A W393 omron cj1 series OMRON plc programming manual CJ1W-B7A04
Text: CJ-series B7A Interface Unit CJ1W-B7A It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort, · The B7A Interface Unit and B7A Link Terminal can , setting and programs are required. System Configuration CJ series CJ1W-B7A@@ B7A Interface Unit , ) B7A Link Terminals http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Rights Reserved. 1 CJ1W-B7A B7A Communications Specifications Item Specifications Transmission


Original
PDF CJ1W-B7A14 CJ1W-B7A22 OMRON cj1 wiring cJ1 OMRON CJ1W -SCU41-V1 CJ1W-B7A14 CJ1W-B7A W393 omron cj1 series OMRON plc programming manual CJ1W-B7A04
1999 - Not Available

Abstract: No abstract text available
Text: B7A Output Unit H Supplies power to the B7A Input Unit, which means it does not require an , between the B7AP-S1 and B7AP-M1 Power Couplers. B7AP B7AP J B7A MODELS Applicable B7A Link , maximum I/O points handled simultaneously by the B7A Input and Output Units. Figures in parentheses indicate the maximum I/O points handled simultaneously by the B7A Input and Output Units each connected , . The maximum I/O points are the same as the maximum input points of the B7A Input Unit connected to the


Original
PDF 1-800-55-OMRON
2009 - cs1g

Abstract: OMRON CPU42 omron CS1G CPU42 vctf 0.75 vctf cable CJ1W-B7A omron CS1G PROGRAMMING MANUAL CS1 Operation Manual W339 sysmac CS1W-B7A
Text: CS-series B7A Interface Unit CS1W-B7A CSM_CS1W-B7A_DS_E_3_1 It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort, · The B7A Interface Unit and B7A Link Terminal can be used in the same way as a standard Basic I/O Unit and I/O Terminal without , BUSY OPEN PERIPHERAL CPU Unit PORT (RS-232C) B7A Input Link Terminal Transmission distance: 500 m max. Sensors Switches B7A Output Link Terminal Lamps or other output devices 1


Original
PDF CS1W-B7A12 cs1g OMRON CPU42 omron CS1G CPU42 vctf 0.75 vctf cable CJ1W-B7A omron CS1G PROGRAMMING MANUAL CS1 Operation Manual W339 sysmac CS1W-B7A
Not Available

Abstract: No abstract text available
Text: 9 B7A Link Remote I/O Components Overview Parts Summary and Configuration Guide to Build a Wire-Saving B7A Link Remote I/O System 1 Just two wires transmit data, simplifies installation and , high-speed systems 32-point output, long distance and high-speed systems I/O configuration Use B7A /B7AS , high-speed systems 32-point input, long distance and high-speed systems Use B7A /B7AS input and output , Directives. B7A Link Overview B7A Link Overview 3 16-POINT TERMINALS Transistor I/O Link Modules


Original
PDF 16-point 32-point CQM1-B7A02 10-point 1-800-55-OMRON
2000 - Not Available

Abstract: No abstract text available
Text: 9 Link Master Adapter B7A-PPP3/8 P Connect High-Density I/O PLC Modules to 16-Point B7A , errors Ordering Information 3 MODEL NUMBER LEGEND Input Models Output Models B7A - T E 1 2 3 4 B7A - R A 1 2 3 4 5 1. Input/Output Classification T: Input 2. Number of I/O 6: 16 3 , Modules B7A Link Master Adapter (32 points) Output Module B7A-R3A13 B7A-R3A33 B7A-R3A18 B7A-R3A38 B7A Link Master Adapter (32 points) Input Module B7A-T3E3 B7A-T3E8 CQM1-ID213 Input Module


Original
PDF 16-Point 32-point OUT20 OUT10 OUT21 OUT11 OUT22 OUT12 OUT23 1-800-55-OMRON
b7am

Abstract: B7A-R6B31 B7A-R6G31 B7A-R6A52 wireless water level indicator B7A-R6F31 B7AS-R6B31
Text: B7A Output Unit H Supplies power to the B7A Input Unit, which means it does not require an , B7AP-M1 Power Couplers. B7AP B7AP J B7A MODELS Applicable B7A Link Terminal Max. I/O , maximum I/O points handled simultaneously by the B7A Input and Output Units. Figures in parentheses indicate the maximum I/O points handled simultaneously by the B7A Input and Output Units each connected , . The maximum I/O points are the same as the maximum input points of the B7A Input Unit connected to the


Original
PDF 1-800-55-OMRON b7am B7A-R6B31 B7A-R6G31 B7A-R6A52 wireless water level indicator B7A-R6F31 B7AS-R6B31
2008 - b7ah

Abstract: B7A-R3A33-M B7AH-R6D53 b7am B7AP-S1 WASHER13 B7A-R6G31 protection couplers B7AS-T6B1 gauge OMRON
Text: B7AP Power Coupler between the B7A Input Unit and B7A Output Unit, it is possible to transmit , the B7A Input Unit and B7A Output Unit is 100 m (when transmitting power or signals). 8±1.5 mm B7A Output Unit B7A Output Unit Signal B7A Input Unit B7A Input Unit B7AP-S1 B7AP-M1 , simultaneously to the B7A Input Unit. ( B7A Input Unit: Input Current 3.8 mA × 10 points = 38 mA) B7A Output Unit B7A Input Unit B7AP-S1 PLC or other controller B7AP-M1 Power Supply Switch


Original
PDF
OMRON C200H

Abstract: M2.5 torque settings C200H-B7A22 D5VM-3B1 K3TX CQM1-B7A21 XS3F-M421-402-R C200H OMRON CABLE C200H BSEN61010-1
Text: digital output for the B7A or 4- to 20-mA linear output corresponding to the 0- to 5-mm travel distances , D5V -3 1 1 2 1. Output A: 4- to 40-mA linear output M: B7A serial communications output , Resolution Part Number Ball type B7A serial communications output (see note) 1 µm D5VM , 16-point B7A Output Link Terminals with a standard transmission delay (i.e., a transmission delay of 19.2 ms). No high-speed B7A Output Link Terminals can be used with the D5VM-3 1. Specifications


Original
PDF 20-mA BSEN61010-1, EN50081-1, prEN50082-2, OMRON C200H M2.5 torque settings C200H-B7A22 D5VM-3B1 K3TX CQM1-B7A21 XS3F-M421-402-R C200H OMRON CABLE C200H BSEN61010-1
2009 - B7AT6C1

Abstract: OMRON C200H M7E-12DRN2 M7E-20DGN1 CJ1W-B7A c200h-od215 M7E-12DGN1 B7A-T10S3 C200H-B7A OD219
Text: Wire-saving Serial Transmission Function ( B7A Output) · Single-color (red or green) and three-color (red , if there is B7A serial input with TB1. 3. Only the numeral will be OFF if there is parallel input with CN1. The decimal point will be OFF if there is B7A serial input with TB1. 4. The previous , terminal. SI Serial data input Models with 120/200-mm-high Characters B7A serial data received , Power supply 0 V power-supply terminal 7 SI Control input B7A serial data received


Original
PDF 200mm) 120-mm B7AT6C1 OMRON C200H M7E-12DRN2 M7E-20DGN1 CJ1W-B7A c200h-od215 M7E-12DGN1 B7A-T10S3 C200H-B7A OD219
2007 - C200H-OD212

Abstract: C200H-OD218 operation manual OMRON CQM1 programming manual c200h-od215 OMRON C200H C200H-OD219 C200H OMRON Operation Manual B7AT6C1 C200H-OD212 omron OD218
Text: lit if there is B7A serial input with TB1. 3. Only the numeral will be OFF if there is parallel input with CN1. The decimal point will be OFF if there is B7A serial input with TB1. 4. The previous , with 120/200 mm-high Characters Positive (+) power-supply terminal. B7A serial data received , 80 mm-high Characters 7 SI Control input B7A serial data received SO Control output B7A serial data transmitted 8 RBO Control output Zero-suppress RBI output (See


Original
PDF 120-mm C200H-OD212 C200H-OD218 operation manual OMRON CQM1 programming manual c200h-od215 OMRON C200H C200H-OD219 C200H OMRON Operation Manual B7AT6C1 C200H-OD212 omron OD218
Not Available

Abstract: No abstract text available
Text: power supply) 1 Connect 3-wire NPN output sensors to B7A screw terminal models (two-wire DC sensors , Models Output Models B7A - T 10 1 2 3 4 1. Input/Output Classification T: Input 2. Number of I/O 10: 10 B7A - R 10 C 1 2 3 4 5 3. Appearance S: Screw terminals M: Printed circuit board , minimum input time is required for the B7A /B7AS to read an input signal. Input Models Item Screw , external sensor current for Input Modules. 3. The minimum input time is required for the B7A to read an


Original
PDF B7A-P10 OUT00 OUT01 OUT02 OUT03 OUT04 OUT05 OUT06 OUT07 OUT08
2013 - Not Available

Abstract: No abstract text available
Text: Wire-saving Serial Transmission Function ( B7A Output) • Single-color (red or green) and three-color (red , is parallel input with CN1. The decimal point will be lit if there is B7A serial input with TB1. 3 , there is B7A serial input with TB1. 4. The previous statuses of A to D before LE goes low will be held , Models with 120/200-mm-high Characters B7A serial data received CN1 (XG4A-2034) Terminal XG4 , 7 SI Control B7A serial data SO input received Control B7A serial data output


Original
PDF 200mm) 120-mm
Z550

Abstract: D5VA-3B1 D5VM-3B1 D5VM-3F1
Text: objects including glass, plastic, and rubber objects. Smart Sensors Models with digital output for B7A , type B7A serial communicaPin type tions output *2 Flat type *1 1 µm D5VA-3F1 D5VM-3B1 D5VM , actuator can be mounted externally. *2. Use the D5VM-3@1 in combination with the B7A Link Terminal Output Unit or a C200H or CQM1 B7A Interface Unit. Use 16- or 32-point Units with a standard transmission , indicators B7A serial communications output (BCD and multipoint ON/OFF output modes *2) 37 ms max. (including


Original
PDF 20-mA F802-E1-01 Z550 D5VA-3B1 D5VM-3B1 D5VM-3F1
1998 - Not Available

Abstract: No abstract text available
Text: with digital output for the B7A or 4- to 20-mA linear output corresponding to the 0- to 5-mm travel , LEGEND D5V -3 1 1 2 1. Output A: 4- to 40-mA linear output M: B7A serial communications output , Resolution Part Number Ball type B7A serial communications output (see note) 1 µm D5VM , the 16-point B7A Output Link Terminals with a standard transmission delay (i.e., a transmission delay of 19.2 ms). No high-speed B7A Output Link Terminals can be used with the D5VM-3 1. 


Original
PDF 20-mA BSEN61010-1, EN50081-1, prEN50082-2, 1-800-55-OMRON
C200H-B7A22

Abstract: OMRON C200H omron k3nx OMRON C200H-B7A21 c200h K3NX D5VA-3B1 OMRON CQM1 WIRING XS3F-M421-402-R Mitsubishi PLC Communication Cable
Text: Models with digital output for the B7A or 4 to 20 mA linear output, corresponding to the 0 to 5 mm , 1 1 2 1. Output A: 4 to 40 mA linear output M: B7A serial communications output 2 , B7A serial communications output (See Note.) Appearance Actuator Resolution Part Number , -3j1 in combination with the 16-point B7A Output Link Terminals with a standard transmission delay (i.e., a transmission delay of 19.2 ms). No high-speed B7A Output Link Terminals can be used with the D5VM


Original
PDF BSEN61010-1, EN50081-1, prEN50082-2, 1-800-55-OMRON C200H-B7A22 OMRON C200H omron k3nx OMRON C200H-B7A21 c200h K3NX D5VA-3B1 OMRON CQM1 WIRING XS3F-M421-402-R Mitsubishi PLC Communication Cable
2011 - j10,7A g g

Abstract: No abstract text available
Text: Wire-saving Serial Transmission Function ( B7A Output) • Single-color (red or green) and three-color (red , lit if there is B7A serial input with TB1. 3. Only the numeral will be OFF if there is parallel input with CN1. The decimal point will be OFF if there is B7A serial input with TB1. 4. The previous , terminal. SI Serial data input Models with 120/200-mm-high Characters B7A serial data received , powersupply terminal 7 SI Control B7A serial data SO received input Control B7A serial data


Original
PDF 200mm) 120-mm j10,7A g g
Supplyframe Tracking Pixel