The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1166CS8#TR Linear Technology LT1166 - Power Output Stage Automatic Bias System; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C
LT3420EDD-1 Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C
LT3420EDD#PBF Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C
LT3420EDD-1#TR Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C
LT3420EMS Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: MSOP; Pins: 10; Temperature Range: -40°C to 85°C
LTC2955IDDB-2#TRPBF Linear Technology LTC2955 - Pushbutton On/Off Controller with Automatic Turn-On; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C

AUTOMATIC PHASE SELECTOR using relay Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2003 - AUTOMATIC PHASE SELECTOR using relay

Abstract: s41 415 FF-SRL59022 AUTOMATIC PHASE SELECTOR application S11-S13 automatic curtain system Honeywell 38240 meylan
Text: provide information on safety relay output status, restart status, intrusion phase status and diagnostics , time (3 s, 15 s, 30 s) can be selected by the operator using an external key selector connected to , FF-SRL59022 multi-safety device relay module with PSDI SERIAL MODES · Inputs for up to 3 , to Category 4 per EN 954-1 The FF-SRL59022 is a programmable safety relay module offering , internal failure is detected and leads to the deenergisation of its safety relay outputs. If needed, the


Original
PDF FF-SRL59022 107110-10-EN AUTOMATIC PHASE SELECTOR using relay s41 415 AUTOMATIC PHASE SELECTOR application S11-S13 automatic curtain system Honeywell 38240 meylan
digital phase selector

Abstract: sevensegment led AUTOMATIC PHASE SELECTOR cp2 manual
Text: : (A) Operating mode selector SW4-1: Output phase selector for transistor output section LH (at , selector SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at , counting (incrementing) (See note.) Down counting (decrementing) SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-1: Output phase selector , counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for transistor output


Original
PDF
RSHL4818CV21

Abstract: No abstract text available
Text: are set by using the selector knob 1 in combination with the push button 4. 2.3.1 Selecting the , Automatic Reset, the Selector Knob 1 is turned to position A and the push button 4 is pressed once. The , marked Phase Seq Enable goes OFF. To enable this function, the Selector Knob 1 is turned to position C and the push button 4 is pressed once. The yellow LED marked Phase Seq Enable goes ON. When using , Alarm Auxiliary output relay End of ramp Auxiliary output relay Power LED Ramp / Bypass LED Phase


Original
PDF 50/60Hz AC-53b 265VAC 370VDC RSHL4818CV21
2005 - XS250NJ

Abstract: tembreak xs250nj terasaki circuit breaker XH125NJ XS800SE XS125NJ XS1250SE XS1600SE BS6N633 terasaki XH630SE
Text: optional functions: Option 1 1) Emergency supply phase failure/sequence relay (EPFR) 1) - detects the , , automatic , manual, emergency supply on, normal supply on. Option 10 - Alarm lockout relay (NALR-EALR , relay (NPFR) - detects phase sequence is correct before the transfer switch reconnects the load to the , power supply relays. A four position mode selector switch is provided loose (manual/ automatic /test , using relay logic are available on application. Basic TemLogic panel TLP1 TemLogic controllers


Original
PDF XS125CJ XS125NJ XH125NJ XH125PJ XS250NJ tembreak xs250nj terasaki circuit breaker XH125NJ XS800SE XS125NJ XS1250SE XS1600SE BS6N633 terasaki XH630SE
2011 - automatic phase selector circuit diagram

Abstract: PROTECTIVE RELAY CEE MANUFACTURER
Text: using +/- Press selector Final limit close fine adjustment Final limit close can change without door movement using +/- Press selector Pre-limit safety edge fine adjustment Pre-limit safety edge can change using +/- Press selector Intermediate stop Move to intermediate stop , Press selector ON Automatic closing feature time can be set between 1 - 240 sec. 0 = OFF Press selector Automatic closing after photo-beam is interrupted and re-made OFF Press


Original
PDF
2009 - FINDER

Abstract: automatic room light control finder delay relay
Text: 45 E32 Control for manual or automatic operation of a hydraulic pump using a level control relay , page 44 Control of manual or automatic operation of a hydraulic pump using a level control , S3-S4 = position selector switches Drawing: E11 Project: Control of lighting system with automatic , , provided that selector switches S1, S2 and S3 are in the automatic position. The miniature power relays , relay control. Examples of applications: - automatic lighting installations Description: At dusk


Original
PDF ZFP0203GB II/09 FINDER automatic room light control finder delay relay
1993 - magnetic Contactor wiring diagrams

Abstract: Allen-Bradley bulletin 509 starter magnetic Contactor wiring diagrams and float switch wiring diagram for float switch electrical welding transformer wiring diagram start-stop LOGIC wiring circuit diagram 700-C200 circuit diagram of single phase water pump 3 phase water pumping machine control schematic allen-bradley key switch 800t
Text: Using 3- Phase Starter . . . . . . . . . . . Variations With START-STOP Stations . . . . . . . . , 4 ,) w Bulletin WIRING DIAGRAMS 509 Single Phase Using Standard S-Phase Starters , T126 T12 Control by an wore" device automatic A selector used to determine , automatic A selector used to determme "two- switch IS speed Speed Low Supply Lines , codes, laws and standards before using any of the typical circuits shown in this publication. The


Original
PDF
Sensor Operated Paper Counting Machine

Abstract: Baumer IVO D-78056 NE210 ZINC OXIDE VARISTORS D78056 D7805 VDE0411 IVO GmbH
Text: delay relay function Line 4 Accept preset value 0 * In the case of automatic , external or manual , NE210 Using the counter as a time delay relay Function Use of the counter as a time delay relay , timescale options ­ Time delay relay with four operating modes Parameters/LED display Control panel Current main counter Selector key for programming/operating mode Preset value Reset key C Scaling factor Setting key for decade values Setting key for decade selection Display Selector key


Original
PDF NE210 NE210 D-78056 Sensor Operated Paper Counting Machine Baumer IVO ZINC OXIDE VARISTORS D78056 D7805 VDE0411 IVO GmbH
TD715

Abstract: din 41622 240v automatic change over switch circuit diagram tr-60228 wiring diagram for a 240v ac to 12v dc transformer 85122 LED OMRON 250v relay ac 11 pin TR551 8 PIN DPDT RELAY 24V dc omron 12v relay 8 pin
Text: three lines of a three phase system increase simultaneously. Line Side Monitoring With the relay , is unprotected against phase failures between the relay and the motor. 1/09 Load Side , . Any fault will de-energize the relay and turn off the LED. Re-energization is automatic upon , instantaneously de-energize the relay and turn off the LED. Re-energization is automatic upon correction of the , voltages or single phasing regardless of any regenerative voltages. The relay is energized when the phase


Original
PDF N5345 TD715 din 41622 240v automatic change over switch circuit diagram tr-60228 wiring diagram for a 240v ac to 12v dc transformer 85122 LED OMRON 250v relay ac 11 pin TR551 8 PIN DPDT RELAY 24V dc omron 12v relay 8 pin
2010 - AUTOMATIC PHASE SELECTOR

Abstract: h7an DIN437000 H7AN-4D PHASE SELECTOR AUTOMATIC PHASE SELECTOR application H7AN-ET HL 100 Transistor 680-W AWG18
Text: selector SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL , -2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for , selector Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase , Memory backup (See note.) No memory backup SW4-1: Output phase selector for transistor output , -1: Output phase selector for transistor output section SW4-2: Manual reset selector 1 2 3 SW4


Original
PDF
Not Available

Abstract: No abstract text available
Text: relay fails to energize, view the LEDs for the cause, and correct the problem. If the phase sequence , ge lta ors Vo nit o M 3 Phase Voltage Monitor WVM Series Motor Protector Description , faults on the 3 Phase Line. The WVM’s microcontroller design provides reliable protection even if , numerous motor loads after a power outage. Operation ANSI Device #27/47/59 Protects Against: Phase , Displayed on 6 LED Readout Switch Selectable Automatic Restart, Delayed Automatic Restart, & Manual Reset


Original
PDF C103PM P0600-11 WVM02B01
2014 - omron plc CPU 41 e rs232 pin configuration

Abstract: transistor f422 PYC35 RGB 5050 IP65
Text: mounted on DIN-rail by using separate adaptor, whilst relay is connected by screw or quick-connect , 15 Human Machine Interface (HMI) URL Product Selector : industrial.omron.eu/ps 7 Switching , 1- phase control K8AK-AS 73 28 K8AK-AW 74 30 K8AK-VS 75 K8AK-VW 76 , 3- phase control Conductive level controller Leakage controller Low voltage switchgear 3 , Motor protection circuit breakers J7MN 53 URL Product Selector : industrial.omron.eu/ps 9


Original
PDF Y209-EN2-02A PanelBuilderGuide2014 omron plc CPU 41 e rs232 pin configuration transistor f422 PYC35 RGB 5050 IP65
AUTOMATIC PHASE SELECTOR using relay

Abstract: 1401 relay
Text: Example: 14 series multi-function relay , single phase switch 1 NO (SPDT-NO) 16 A contact, supply rated at , selectable with front selector Staircase relay On initial impulse the output contact closes and timing , "Switch-off early warning" - model 14.01 · Suitable for 3 or 4 wire systems, with automatic recognition , both flat blade and cross head screw drivers can be used to adjust the function selector , the timing , (low emission) illuminated pushbuttons · Suitable for 3 or 4 wire systems, with automatic recognition


Original
PDF
2007 - siemens 3UG3

Abstract: 3UG35 3UG4615 3ug3 SIEMENS RELAY 3UG46 3ug46 3UG45 siemens 3UG3 monitoring relays SIEMENS RELAY 3UG46 15 siemens 3UG35
Text: sequenced relay monitors the phase sequence in a three-phase network. No adjustments are required for , phase sequence at the terminals L1-L2-L3 is correct, the output relay picks up after the delay time has elapsed and the LED is lit. If the phase sequence is wrong, the output relay remains in its rest position. The 3UG45 12 line monitoring relay monitors three-phase networks with regard to phase sequence , phase sequence at the terminals L1-L2-L3 is correct, the output relay picks up. If the phase sequence


Original
PDF 3UG46 3UG45 siemens 3UG3 3UG35 3UG4615 3ug3 SIEMENS RELAY 3UG46 siemens 3UG3 monitoring relays SIEMENS RELAY 3UG46 15 siemens 3UG35
AUTOMATIC PHASE SELECTOR

Abstract: interposing relay automatic ac selector
Text: 19 Series - Modular Auto-Off-On relay 10 A Features 19.21 Auto-Off-On over-ride relay 3 function selector switch: - Auto (works as a monostable relay ) - Off ( relay permanently OFF) - On ( relay , 0.5 Selector position Selector Control switch switch (S) AUTO Output LED relay Feedback , Rated load AC15 (230 V AC) VA 500 Single phase motor rating (230 V AC) kW Breaking , ­10.+50 IP 20 Approvals (according to type) 1 19 Series - Modular Auto-Off-On relay 10 A


Original
PDF
2013 - gefran 230

Abstract: gefran pt100
Text: independent controls and advanced diagnostics. Used to control power for single-phase and 3- phase loads , primaries. Unit consisting of: • Controller • 30, 60, 80kW solid state relay • Current , configurable output (option): relay / logic / TRIAC / continuous • 2 configurable relay alarm output â , elements such as: • controller • solid state relay • current transformers • fuses-holders , to manage singlephase and 3- phase loads, with low and high temperature coefficient, medium and


Original
PDF E243386 2004/108/CE 2006/95/CE gefran 230 gefran pt100
wiring diagrams automatic voltage regulator

Abstract: FINDER RELAY un 1950 automatic ac selector PLC WIRING DIAGRAM OF MOTOR 3 phase ac motor speed control modules AUTOMATIC PHASE SELECTOR application single phase motor fire system control plc plc wiring standard
Text: 11.2 mm wide · 3 function selector switch: - Auto: works as a monostable relay (following A3 input , function selector switch: - Auto: work as a monostable relay relay (following A3 input) - Off: relay , selector switch in position "A" ( Automatic ) the (0.10) V signal is derived from the controller. In , ( Automatic ) the 0.10 V set point of Yin - A2 is leaded, through Yout, to the end process; in the selector , " Automatic " position, signals from the BMS, DDC or PLC-system will be transferred, unchanged, to the


Original
PDF 17x25 wiring diagrams automatic voltage regulator FINDER RELAY un 1950 automatic ac selector PLC WIRING DIAGRAM OF MOTOR 3 phase ac motor speed control modules AUTOMATIC PHASE SELECTOR application single phase motor fire system control plc plc wiring standard
schneider LRD 08

Abstract: LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21
Text: the cover. 7 Selector for manual or automatic reset. Relays LRD-01 to 35 are supplied with the , . Class 10 A tripping p Compensated relays with manual or automatic reset, p with relay trip indicator , fuses. Class 20 tripping Compensated relays with manual or automatic reset, with relay trip indicator , overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, long , simulation of relay tripping (actuates both the N/O and N/C contacts). 3 Stop button. Actuates the N/C


Original
PDF LRD-01. LRD-3322. LR9-D67 LR9-D69 schneider LRD 08 LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21
AUTOMATIC PHASE SELECTOR using relay

Abstract: No abstract text available
Text: Example: 14 series multi-function relay , single phase switch 1 NO (SPDT-NO) 16 A contact, supply rated at , "Switch-off early warning" - model 14.01 · Suitable for 3 or 4 wire systems, with automatic recognition , both flat blade and cross head screw drivers can be used to adjust the function selector , the timing , (low emission) illuminated pushbuttons · Suitable for 3 or 4 wire systems, with automatic recognition , can be used to adjust the function selector , the timing trimmer, and to disengage the 35 mm rail


Original
PDF
siemens sirius 3r

Abstract: Sirius 3R 3RT1044 3RB1056-1FG0 3RB1066-1KG0 3RB1066-1GG0 3UA7* siemens 3rt1036 3RT1035 3RU1126-4AB0
Text: 7 8 9 Equipment identifying marker Manual/ automatic RESET selector switch STOP button , . contacts (when mounted on contactor) 3RU111 Overload Relay Phase failure sensitivity A phase , IEC Contactors Catalog Supplement 1 Marking Strip 2 Manual/ automatic RESET selector switch 3 , , sealable (secures the current setting screw, TEST function and manual/ automatic RESET position) Current , phase failure, i.e. faster tripping in the event of a single-phase condition. Setting the overload


Original
PDF 3RU11 3RT10 3RB105--for 3RT105 3RB1056-1FW 3RT1054 siemens sirius 3r Sirius 3R 3RT1044 3RB1056-1FG0 3RB1066-1KG0 3RB1066-1GG0 3UA7* siemens 3rt1036 3RT1035 3RU1126-4AB0
Not Available

Abstract: No abstract text available
Text: recommended for safety (not required) Relay contacts are isolated. L1 = Phase A L2 = Phase B L3 = Phase , (motor) failure caused by voltage faults on the 3- phase line. The WVM’s microcontroller design , for connection diagram. Features: • Protects against phase loss & reversal; over, under & , selectable automatic restart, delayed automatic restart, & manual reset • Isolated, 10A, SPDT output , : Auxiliary Products: • 3- phase fuse block/disconnect: P/N: FH3P • 2 Amp fuse: P/N: P0600-11 â


Original
PDF
2014 - kss 152a laser

Abstract: ILP toroidal transformer Diode BFK 66A b1250 15000 6Kv marking 5d capacitor fire alarm using IC 555 and thermistor wiring diagram STAR DELTA motor sequential starter LRD20 KBP 2060 LCD display 1602A
Text: selector switches • Automatic power factor controllers • Pushbuttons and selector switches , RUN MON STOP ENT Pushbuttons and selector switches Signal towers and beacons 8 Limit , Protection relays Level control relays 19 Micro PLCs 20 21 Automatic battery chargers 22 , Energy management 18 Switching power supplies Automation and control 17 24 Automatic , version is also equipped with two relay outputs for remote signalling of alarms and bypass relay


Original
PDF EXP10 RS232/TTL kss 152a laser ILP toroidal transformer Diode BFK 66A b1250 15000 6Kv marking 5d capacitor fire alarm using IC 555 and thermistor wiring diagram STAR DELTA motor sequential starter LRD20 KBP 2060 LCD display 1602A
2009 - LC1 D32 wiring diagram

Abstract: LC1 contactor LA7 D09 54 overload schneider overload relay lrd 25 schneider thermal overload relay lrd 32 schneider electric LC1 D25 LC1 d32 contactor diagram LA7 D09 AM1-DP200 LC1 d150 wiring diagram
Text: relay ), b or by using a multifunction protection relay type LT6. Protection relays Relay type , the cover. 7 Selector for manual or automatic reset. Relays LRD 01 to 35 are supplied with the , automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A) Fuses to be , atmosphere) 19 % Phase failure 14 % Bearing failure 13 % Ageing (example: ambient , thermistor probes (1) b multifunction relays. Protection by thermal overload relay A conventional


Original
PDF MKTED205103EN LC1 D32 wiring diagram LC1 contactor LA7 D09 54 overload schneider overload relay lrd 25 schneider thermal overload relay lrd 32 schneider electric LC1 D25 LC1 d32 contactor diagram LA7 D09 AM1-DP200 LC1 d150 wiring diagram
ASEA EG 10 contactor

Abstract: asea time-lag relay RI RRCEA asea contactors tap control transformer RAYA asea EG contactor rCEA circuit diagram of three phase automatic changeover switch relay driver circuit using transistor 3604 relay
Text: regulating relay type RCEA for a.c. supply is ASEA also manufactures a voltage regu- used to regulate the secondary voltage of power transformers with on- latlng relay type RAYA of COMBIFLEX® load tap-changers. The relay provides an accurate means of automatic design described in Catalogue RK 82-10 E. voltage , Selector switch 7 Direct-on-line starter 54 Voltage regulating relay type RCEA') Components not numbered , ASEA Catalogue RK 82-2 E Edition 2 July 1973 File R, part 2 Voltage regulating relay type RCEA For


OCR Scan
PDF
LRD schneider relay

Abstract: LRD-340 L schneider LRD 08 schneider LRD 365 LRD 15 Schneider NSX 400 F LRD 350 LA7 D09 overload schneider thermal overload relay lrd 32 LRD-365
Text: locked by sealing the cover. 7 Selector for manual or automatic reset. LRD 01 to 35 and LRD 313 to LRD , automatic reset, b with relay trip indicator, b for a.c. or d.c. 1 LRD pp 2 Relay setting range , manual or automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A , circuit-breakers GV2 L and GV3 L b Compensated relays with manual or automatic reset, b with relay trip indicator , against: b overloads, b phase failure, b excessively long starting times, b prolonged stalled rotor


Original
PDF D3064 DP200 DE200 D35pp D1020 M10x1 LRD schneider relay LRD-340 L schneider LRD 08 schneider LRD 365 LRD 15 Schneider NSX 400 F LRD 350 LA7 D09 overload schneider thermal overload relay lrd 32 LRD-365
Supplyframe Tracking Pixel