The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LTC4361CDC-1#TRPBF Linear Technology LTC4361-1/LTC4361-2 - Overvoltage/Overcurrent Protection Controller; Package: DFN; Pins: 8; Temperature Range: 0°C to 70°C
LTC4361IDC-1#TRMPBF Linear Technology LTC4361-1/LTC4361-2 - Overvoltage/Overcurrent Protection Controller; Package: DFN; Pins: 8; Temperature Range: -40°C to 85°C
LTC4361CDC-2#TRMPBF Linear Technology LTC4361-1/LTC4361-2 - Overvoltage/Overcurrent Protection Controller; Package: DFN; Pins: 8; Temperature Range: 0°C to 70°C
LTC4361IDC-1#PBF Linear Technology LTC4361-1/LTC4361-2 - Overvoltage/Overcurrent Protection Controller; Package: DFN; Pins: 8; Temperature Range: -40°C to 85°C
LTC4361HDC-2#PBF Linear Technology LTC4361-1/LTC4361-2 - Overvoltage/Overcurrent Protection Controller; Package: DFN; Pins: 8; Temperature Range: -40°C to 125°C
LTC4361IDC-2#PBF Linear Technology LTC4361-1/LTC4361-2 - Overvoltage/Overcurrent Protection Controller; Package: DFN; Pins: 8; Temperature Range: -40°C to 85°C

ANSI overcurrent relay inverse normal curves Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
overcurrent relay inverse normal curves

Abstract: GE multilin 750 GE multilin 750 relay BS142 C-5047-77 master trip relay ANSI overcurrent relay inverse normal curves multilin 750 lockout relay RS422 TO RS232 CONVERTOR CIRCUIT
Text: time, moderately inverse , inverse ,very inverse , extremely inverse ; see time/ overcurrent curves , inverse ; see time/ overcurrent curves ; curves apply up to 20 x pickup or 20 x sensor (whichever is less , amp CT input s ANSI , IAC or IEC/BS142 curves s 20 ­ 260 V AC/DC control power , is set to OFF, the TOC is disabled. 6 ANSI IAC IEC/BS142 Moderately inv. Normal , metering. These features include: Status LEDs The relay features LEDs that indicate normal operation


Original
PDF IEC/BS142 50G/51G RS485 RS422 RS232 808785E3 overcurrent relay inverse normal curves GE multilin 750 GE multilin 750 relay BS142 C-5047-77 master trip relay ANSI overcurrent relay inverse normal curves multilin 750 lockout relay RS422 TO RS232 CONVERTOR CIRCUIT
GE Power Management multilin SR 750

Abstract: GE multilin 750 GE multilin 750 relay relay GE multilin 760 multilin multilin 750 BS142 GE circuit breaker 1 pole C2 aeg power base 60 b data sheet relay GE multilin 760
Text: Inverse Inverse Short Inverse Custom The 750/760 Feeder Management Relay is a digital relay , www.GEindustrial.com/Multilin 750/760 SR Feeder Management Relay ® FE ANSI ED ER Ca pac ito r Ra dia , the relay for each phase. If directional control is enabled, overcurrent elements are blocked if , parameter s return to normal . leading (-) Automatic Restoration OUTAGE -1 exceeded the relay , Dropout level: 97 to 98% of Pickup Curve shape: ANSI extremely/very/moderately/ normally inverse


Original
PDF
GE Power Management multilin SR 745

Abstract: GE multilin 750 GE Power Management multilin SR 750 relay GE 745 multilin C37-90 multilin 745 BS142 automatic 3 phase changer relay multilin
Text: RESTRAINT REGION Irestraint(x CT) Selected Relay Time Overcurrent Curve Transformer Thermal , dial): 0.5 ­ 30 for ANSI , IAC and FlexCurveTM in steps of 0.1 0.05 ­ 1.00 for IEC curves in steps of , SR Transformer Management RelayTM 4 High-speed, multi-processor based relay for primary , upgradeable option s RS232, RS485 and RS422 ports ® s Percent differential, overcurrent , large power transformers GE Multilin 69 745 SR Transformer Management Relay TM


Original
PDF 808785E3 GE Power Management multilin SR 745 GE multilin 750 GE Power Management multilin SR 750 relay GE 745 multilin C37-90 multilin 745 BS142 automatic 3 phase changer relay multilin
2008 - 11kV breaker control circuit diagram

Abstract: 1YMA583791R0001-4 ABB REJ 603 Relay manual REJ603-CT2 REJ603-CT3 REJ603-CT4 REJ603 REJ603-CT5 IDMT relay ABB breaker S5
Text: Protection ANSI Three phase overcurrent protection, low-set stage 3I> 51 Three phase , with the BS142 and IEC 60255 and are named Normal inverse , Very inverse , Extremely inverse , Long-time inverse . Three special curves namely RI-curve, HR Fuse curve, and FR Fuse curve are also provided. L1 , overcurrent or earth-fault unit operates, the relay issues a `trip' command in the form of a low energy , ms, whichever is greater Setting of inverse time characteristics IEC 60255-3: Normal Inverse


Original
PDF REJ603 1MDU07206-YN REJ603BBB10NN3XA 1YMA583791R0001-4. 11kV breaker control circuit diagram 1YMA583791R0001-4 ABB REJ 603 Relay manual REJ603-CT2 REJ603-CT3 REJ603-CT4 REJ603 REJ603-CT5 IDMT relay ABB breaker S5
2013 - CSH120

Abstract: E4000000
Text: Overcurrent Protection ( ANSI 50-51) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Earth Fault Protection ( ANSI 50N-51N) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overcurrent Protection Tripping Curves . . . . . . . . . . . . . . . . . , Overcurrent Cold Load Pick-Up (Cold Load Pick-Up I) (VIP410). . . . . . . . . . . . . . . . . . Earth Fault , Thermal Overload Protection ( ANSI 49RMS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Original
PDF VIP400, VIP410 NRJED311206EN NRJED311206EN VIP410 CSH120 E4000000
2001 - ANSI overcurrent relay inverse normal curves

Abstract: siemens relay siemens master trip relay siprotec
Text: available ANSI /IEC inverse-time curves are: • Inverse • Short inverse • Long inverse â , 7SD610 Differential Protection Relay for Two Line Ends Functions Differential protection ( ANSI 87L , setpoint may be increased for a settable time. Under normal operating conditions, the relay is switched , can be combined with overcurrent pickup. In this case pickup of the protection relay is initiated , protection ( ANSI 50, 50N, 51, 51N) The 7SD610 provides a threestage overcurrent protection. Two


Original
PDF 7SD610 E50001-K4405-A141-A1-7600 6101/D6159 ANSI overcurrent relay inverse normal curves siemens relay siemens master trip relay siprotec
2009 - IDMT relay

Abstract: Allen-Bradley 857 857-VX003-3 IDMT OVERCURRENT relay 857-PM001A-EN-P Delta Electronics dps -300HB A 44358 Delta Electronics dps -350MB A Digital Alarm Clock 50250 delta plc cable pin diagram RS-485
Text: Undirectional Earth Fault Overcurrent Stages . Inverse , . 3-80 IEEE/ ANSI Inverse Time Operation . 3-83 IEEE2 Inverse Time Operation , Programmable Inverse Time Curves . 3-91 Inverse Time Setting Error Signal , Main Relay Features .1-1 User Interface , Relay Front Panel .2-1 Display


Original
PDF 857-UM001A-EN-P IDMT relay Allen-Bradley 857 857-VX003-3 IDMT OVERCURRENT relay 857-PM001A-EN-P Delta Electronics dps -300HB A 44358 Delta Electronics dps -350MB A Digital Alarm Clock 50250 delta plc cable pin diagram RS-485
2010 - calculation of transformer differential relay setting for RET615

Abstract: ref 615 abb interposing CT transistor A968 PCM600 IDMT characteristic of REM - 615 ABB vn-240 pc 1MAC050144-MB 3 phase motor soft starter circuit diagram, ABB IDMT relay
Text: Relion® Protection and Control 615 series ANSI Technical Manual Document ID: 1MAC050144 , series and ANSI C37.90. Table of contents Table of contents Section 1 Introduction , series ANSI Technical Manual 1 Table of contents Binary input inversion , overcurrent protection 51P/50P.57 Identification , non-directional long-time overcurrent protection


Original
PDF 1MAC050144-MB PCM600 1MAC050144-MB calculation of transformer differential relay setting for RET615 ref 615 abb interposing CT transistor A968 PCM600 IDMT characteristic of REM - 615 ABB vn-240 pc 3 phase motor soft starter circuit diagram, ABB IDMT relay
T5N400

Abstract: T4H250 PR222DS T4N250 ABB TMAX T7 PR221DS ABB Sace PR121 ABB T5N400 PR221DS sace tmax dip switch setting PR221DS-LS
Text: protection functions: - the long time-delay trip function ( ANSI code: 51, AC time overcurrent relay ); - the short time-delay trip function ( ANSI code: 51, AC time overcurrent relay ); - the instantaneous trip function ( ANSI code: 50, instantaneous overcurrent relay ); - the ground-fault trip function ( ANSI code: 51 , with time delay trip (short time delay trip function, ANSI code 51, AC time overcurrent relay ), is , trip function, ANSI code 50, instantaneous overcurrent relay ) is identified by Function I. If the


Original
PDF 1SXU210170B0201 LV170] T5N400 T4H250 PR222DS T4N250 ABB TMAX T7 PR221DS ABB Sace PR121 ABB T5N400 PR221DS sace tmax dip switch setting PR221DS-LS
GE Power Management multilin SR 750

Abstract: IRIG-b multilin 489 3 phase induction generator synchronization GE multilin 750 51GN multilin HGF-CT overcurrent relay inverse normal curves 489 generator protection system ac induction tachometer generators
Text: undervoltage. Alarm or trip functions may be activated by definite or inverse time curves . Loss of field , inverse TOC. Time (Seconds) 1000 K=1.0 4.0 15 40 100 High-set phase overcurrent provides , system faults. The pickup level for the inverse time curves are adjusted in conjunction with the , 100% stator ground s Overcurrent , over and undervoltage s Data communications from 300 to , enerVista.com compatible (see page 275) GE Multilin 1 489 SR Generator Management Relay TM


Original
PDF 808785E3 GE Power Management multilin SR 750 IRIG-b multilin 489 3 phase induction generator synchronization GE multilin 750 51GN multilin HGF-CT overcurrent relay inverse normal curves 489 generator protection system ac induction tachometer generators
2013 - IDMT OVERCURRENT relay

Abstract: VIP300LL/VIP300LH
Text: this is the case, if the current does not decrease, the relay will trip. For IDMT curves (SI, VI, EI , is the case, if the current does not decrease, the relay will trip. for IDMT curves (SI, VI, EI , easy relay testing. The test may be carried out during normal operation of the installation since the , . ANSI symbol. IEC symbol. Safety alert This is the safety alert symbol. It is used to alert you , 4 Presentation of the VIP300 relay 4 Presentation of sensors 5 Description of VIP300


Original
PDF VIP300 PCRED399008EN PCRED399008EN/1 IDMT OVERCURRENT relay VIP300LL/VIP300LH
SPAJ 120

Abstract: IDMT OVERCURRENT relay IDMT IDMT relay SPAJ 120 c abb spaj RELAY SPAJ 120 manual SPTU 240 ABB SPAJ 120 circuit diagram of moving LED message display cir
Text: General characteristics of C-type relay modules Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral overcurrent stage with definite time , the earth-fault relay can be given either definite-time or inverse-time characteristic. At inverse , : Normal inverse , Very inverse , Extremely inverse and Long-time inverse . These curve sets comply with the , relay SPAJ 110 C. The encircled numbers refer to the ANSI (=American National Standards Institute


Original
PDF 1043B 750801-MUM FIN-65101 SPAJ 120 IDMT OVERCURRENT relay IDMT IDMT relay SPAJ 120 c abb spaj RELAY SPAJ 120 manual SPTU 240 ABB SPAJ 120 circuit diagram of moving LED message display cir
2009 - ABB NI 40 Relay manual

Abstract: REF-601 ABB NI 41 Relay manual IDMT OVERCURRENT relay overcurrent relay inverse normal curves IDMT relay ABB NI 41 Relay settings IEC60068-2-29 ref601 IEC standard for Rogowski Coil
Text: IEC 60255-3: Normal inverse , Extremely inverse , Very inverse , Long time inverse Special curves : RI , ANSI code Three-phase non-directional overcurrent , low-set stage 3I> 51 Three-phase , normal conditions the relay is energized and the contact gap 5-6 in connector XK2 is closed. If the , =1 0.5.8.0 sec in steps of 0.5 for B=5 Inverse time characteristics IEC 60255-3: Normal inverse , Extremely inverse , Very inverse , Long time inverse Special curves : RI inverse time Accuracy of pick-up


Original
PDF REF601 1MDU07204-YN 1MDU07204-YN ABB NI 40 Relay manual REF-601 ABB NI 41 Relay manual IDMT OVERCURRENT relay overcurrent relay inverse normal curves IDMT relay ABB NI 41 Relay settings IEC60068-2-29 IEC standard for Rogowski Coil
2014 - IEC60255

Abstract: No abstract text available
Text: Testing (ALT) to validate accurate relay functions under specified normal conditions. The device is , overloading criteria. Overcurrent Elements The 345 relay provides phase, neutral, ground and negative , 0.02 x CT @ I > 1 x CT Curve Shape: ANSI Extremely/Very/Moderately/ Normally Inverse Definite Time , over-current protections • Draw out and non draw out options available APPLICATIONS • Low and , Timed and Instantaneous over-current • Phase and Ground Timed and Instantaneous over-current â


Original
PDF GEA-12778K IEC60255
1998 - IEEE Std 242-1986

Abstract: calculation of transformer differential relay DIFFERENTIAL PROTECTION CALCULATION
Text: Recognized as an American National Standard ( ANSI ) IEEE Std 242-1986 (Revision of IEEE Std , . 103 4.11 Time-Overcurrent and Instantaneous Overcurrent Relays-Device Nos 50, 51, 50/51, and 51 , . 112 4.14 Directional Overcurrent Relay-Device Nos 67 and 87G , . 141 5.8 Time-Current Characteristic (TCC) Curves , . 159 5.12 ANSI Standards-Medium Voltage and High Voltage (2.4­138 kV


Original
PDF
SPCJ 4D29

Abstract: SPTU 240 SPAJ 120 abb spaj RELAY SPAJ 120 c 4D29 SPAJ 140 IRF 9710 SPAJ160C ABB SPAJ 120
Text: inverse ( ANSI ) time charcteristic Phase unbalance protection stage with definite time charcteristic , for selective network protection. In this case an overcurrent and earth-fault protection relay from , and the inverse curve is based on ANSI /IEEE C37.99 and IEC 60871-1 recommendations for the capacitor , similar gradient to the normal inverse curve.The starting value can be set within the range 2.80% of , relay . Under normal conditions the relay is operated and the contact gap 70-72 is closed. If a fault is


Original
PDF 750064-MUM FIN-65101 SPCJ 4D29 SPTU 240 SPAJ 120 abb spaj RELAY SPAJ 120 c 4D29 SPAJ 140 IRF 9710 SPAJ160C ABB SPAJ 120
2009 - REF630

Abstract: calculation of transformer differential relay RET 670 star delta FORWARD REVERSE STARTER 1MRS756508 ABB HCA BREAKER OF INN 9182 wind turbine mini project abb 630 PROJECT REPORT ON 220 kv substation inn 9182
Text: .175 Three-phase non-directional overcurrent protection PHxPTOC , directional overcurrent protection DPHxPDOC , .200 Measuring Directional overcurrent , time overcurrent protection MNSPTOC.386 Identification


Original
PDF 1MRS756508 RS485 FI-65101 1MRS756508 REF630 calculation of transformer differential relay RET 670 star delta FORWARD REVERSE STARTER ABB HCA BREAKER OF INN 9182 wind turbine mini project abb 630 PROJECT REPORT ON 220 kv substation inn 9182
2011 - STS Bv 1500 current transformers

Abstract: Wiring Diagram thermostat NC 40 NC 90 ACE850 V/STS Bv 1500 current transformers EGX300 umi x22
Text: applications Protection functions ANSI code Phase overcurrent 50/51 (1) Phase overcurrent , functions ANSI code Earthing system TN-S b Phase overcurrent (1) 50/51 b 50N/51N Earth fault , protection relay Maintain installation availability Sepam maintains high energy availability thanks to , digital protection relay to deliver dependability and behaviour in the event of failure meeting the , diagnostics for all applications in an installation. Range modularity makes it easy to select the relay


Original
PDF SEPED303005EN STS Bv 1500 current transformers Wiring Diagram thermostat NC 40 NC 90 ACE850 V/STS Bv 1500 current transformers EGX300 umi x22
2007 - Westinghouse Sudden Pressure Relay

Abstract: 115KV transformer westinghouse transformer inrush
Text: . Ideally, the relay also should have negative sequence overcurrent (46), negative sequence overvoltage , significantly exceed normal . The solid curves of Fig. 17 illustrate the variation in fundamental frequency , relay . The references provide a source for additional theory and application guidance. • An , industrial customer. There are three general categories of protective relay technology that arise in the , , programmable logic relay ; digitizes sensed current and voltage, then calculates an RMS or phasor equivalent


Original
PDF BE1-51 Westinghouse Sudden Pressure Relay 115KV transformer westinghouse transformer inrush
2012 - Magnetic Sensor 81l

Abstract: residual voltage overvoltage 59N broken conductor telemecanique timer catalogue ANSI 87T
Text: relay for each application… 27TN/64G-2, 67, 67N, 87T O Overcurrent Long distance L Line , applications Protection functions ANSI code Phase overcurrent 50/51 (1) Phase overcurrent , functions ANSI code Earthing system TN-S b Phase overcurrent (1) 50/51 b 50N/51N Earth fault , protection relay Maintain installation availability Sepam maintains high energy availability thanks to , digital protection relay to deliver dependability and behaviour in the event of failure meeting the


Original
PDF SEPED303005EN Magnetic Sensor 81l residual voltage overvoltage 59N broken conductor telemecanique timer catalogue ANSI 87T
2010 - 10000 watt stabilizer transformer winding formula

Abstract: 1407-CGCM leroy somer static var compensator distortion factor generator rotating Diodes ABB SHUNT TRIP V2 pH Controller/Monitor users manual 1407-UM001E-EN-P tag 87
Text: . . . . . . . . . . . . . . . . 147 Appendix A Time Over-current Characteristic Curves , . . . . . . . . . . . . . . . 161 Time Over-current Characteristic Curve Graphs. . . . . . . . . . , (32R) · Rotating diode monitor · Phase rotation error (47) · Generator over-current (51) Metering , Pulse-width modulated output power stage rated at 15 A · Discrete redundancy relay output · Discrete fault , fault output RD RLY Open collector output for redundancy relay CH GND Chassis ground V


Original
PDF 1407-CGCM RA-DU002, 1407-UM001E-EN-P 1407-UM001D-EN-P PN-82909 10000 watt stabilizer transformer winding formula 1407-CGCM leroy somer static var compensator distortion factor generator rotating Diodes ABB SHUNT TRIP V2 pH Controller/Monitor users manual tag 87
RTXP24

Abstract: RELZ100 ABB STT 111 distance relay earth BUSBAR calculation RTXP 18 depth calculation diSTANCE relay REL 300 power line carrier communication abb ABB REXA-101 RLKD 100
Text: directional earth fa It overcurrent relay . The full scheme distance relay 's ability to cover evolving , Logarithmic Normal inverse Veryinverse Extremely inverse } 5-j300% of In Cu*rent multiplier K , -Typical operate time 28 ms -Versatile man-machine-communication (MMC) from relay front panel -Positive , Substation Monitoring System (SMS), Substation Controi System (SCS) and/or Relay testing System (RTS). The , single-phase ripping -Power swing blocking r~lay -Directional or nondirectlonal earth fault relay -Weak


Original
PDF 100/RELZ 1MPBO600 1MDUO6004-EN 1MDUO6012-EN 100/REOR MDB10004-EN 1MDB10006-EN MDBO6004-EN RTXP24 RELZ100 ABB STT 111 distance relay earth BUSBAR calculation RTXP 18 depth calculation diSTANCE relay REL 300 power line carrier communication abb ABB REXA-101 RLKD 100
2012 - Not Available

Abstract: No abstract text available
Text: following purposes: - During normal relay operation: Display of various measured parameters together , Fundamental harmonic overcurrent protection: Tripping threshold I> 280 A; Delay 0,5s; Output relay RE2; Tripping threshold I>> 300 A; Delay 0,5s; Output relay RE2; Overcurrent protection I(RMS): Tripping , ; Output relay settings: Inverse Funktion: unused; Doc.No.: 13173 - Rev. 02 Page 22 of 50 ESTAsym , Capacitor protection relay ESTAsym MD Operating instructions QUALITY MANAGEMENT


Original
PDF D-84030 2556/QM/03
2009 - REF-601

Abstract: ABB NI 40 Relay manual IDMT relay IDMT OVERCURRENT relay ABB NI 41 Relay manual ABB NI 41 Relay settings 1YMA583791R0001-4 1MDU07205-YN ref601 IEC60068-2-29
Text: Protection ANSI code Three-phase non-directional overcurrent , low-set stage 3I> 51 , ANSI code Three-phase non-directional overcurrent , low-set stage 3I> 51 Three-phase , normal conditions the relay is energized and the contact gap 5-6 in connector XK2 is closed. If the , input, will reset all the indications to normal state. Relay indications include protection start , time/current curve sets ­ four according to the BS 142 and IEC 60255 standards namely normal inverse


Original
PDF REF601 1MDU07205-YN 1MDU07205-YN REF-601 ABB NI 40 Relay manual IDMT relay IDMT OVERCURRENT relay ABB NI 41 Relay manual ABB NI 41 Relay settings 1YMA583791R0001-4 IEC60068-2-29
calculation of transformer differential relay RET 670

Abstract: 40 MVA transformer mva transformer three winding transformer RET670 calculation of line differential relay RED 670 calculation of transformer earthing resistor IEC61850 calculation of transformer differential relay RED 670 diode CODE 51n
Text: step phase overcurrent function has an inverse or definite time delay independent for each step , dependent resistor externally to the relay . Instantaneous residual overcurrent protection (PIOC, 50N , protection (PEFM, 51N/67N) The four step single input overcurrent function has an inverse or definite time , inverse time characteristic. The overcurrent protection steps can be made directional with selectable , directional or non-directional · Each step can be inverse or definite time delayed - For multi


Original
PDF 080-BEN 075-WEN 077-WEN 1KHA001027 1MRS755552 SE-721 calculation of transformer differential relay RET 670 40 MVA transformer mva transformer three winding transformer RET670 calculation of line differential relay RED 670 calculation of transformer earthing resistor IEC61850 calculation of transformer differential relay RED 670 diode CODE 51n