The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
CCH75K3 GE Critical Power CCH Series, 75 Watt Swithing Power Supply
CLP0212FPEX5Z03A GE Critical Power CLP0212 Open Frame Power Supply, 90 - 264Vac input; 12Vdc output; 200W Output Power
CLP0412FPXXXZ03A GE Critical Power CLP0412 Open Frame Power Supply, 90 - 265Vac Input; 12Vdc Output; 450W Output Power
GP100H3M54TEZ GE Critical Power GP100 6 kW True Three Phase Rectifier, 110A rectifier with isolated dual I2C communications 54V
SLP0712TEXR5Z01A GE Critical Power SLP0712TE Series Power Supply, 90 - 264Vac input; 12Vdc output; 750W Output Power, 3.3 Vdc or 5.0Vdc/2A Auxiliary Output
CCH125F1-1A GE Critical Power CCH125 Series, 125 Watt Switching Power Supply

AC voltmeter pic 16f877 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2001 - ic 12ce518

Abstract:
Text: supported devices include the PIC family from Microchip Technology, SX devices from Ubicom (formerly , specific data range Support sequential serialization (for Microchip PIC only) All option or configuration , PGM2000 MCU comes with AC adapter, parallel cable, software and printed user's guide LCD Display PGM2000 Ver01.30 DEVICE1 16F877 CKSUM=15AC PROGRAM1 AUTO BLANK CHECK1 VERIFY1 , settings (for PIC and Ubicom devices) at one time, in memory areas 1 and 2 respectively. The numeral


Original
PDF PGM2000 Ma28G-SS SX48G-TQ SX52G-PQ DIP18/28 SOIC18/28 SSOP20 SSOP28 ic 12ce518 PIC 16f84a PROGRAMMER sample codes of PIC12C508 ic 16f84a lcd 2x16 16f877 16f874 datasheet 16F870 MICROCHIP DIP40 MCU PGM2000-MCU
4 digit digital voltmeter pic

Abstract:
Text: digital panel modules r user guide OEM33 3.5 digit LCD digital voltmeter electronics , 150 ppm/ °C PIN FUNCTIONS VDD Positive supply terminal VSS Negative supply terminal for 9 volts , terminal is connected to XBP. BAT, °C , °F,~, m, n, Mf2, Kn, V, A, HOLD2 Annunciators ORDERING INFORMATION OEM33 3.5 digit, 200mV LCD Voltmeter All annunciators not in use must be connected to the BP , )(R3) > VDD+1 5V R1+R2+R3 anders electronics pic Bayham Place, London NW1 OEU Tel: +44 (0)20 7380


OCR Scan
PDF OEM33 200mV 4 digit digital voltmeter pic digital voltmeter pic 2 pole 4 way rotary switch pin configuration LCD 3.5-DIGIT 1 pole 4 way O E N rotary switch pic voltmeter "digital panel meters" 13 pin dc voltmeter Circuits X1000
TA8655an

Abstract:
Text: 7.3 V TOSHIBA CORPORATION - 617- TOSHIBA TA8655AN 3. AC C H A R A C T E R IS T , Bandwidth ATT AC Gain ATT Max. Attenuation Volume AF AMP AC Gain V ID E O VLim V0D AMR BW SIF BW THD Gy , that AC ampli tude 0.6 Vp-p (fm = 58.7 MHz) and DC output 5 Vp-p are obtained. 1) Signal obtained by , ^2 measured with a digital voltmeter . 1) PIF signal 15 mVrms (no modulation) is added to Vi. 2) Voltage at TPj^ measured with a digital voltmeter . 1 Input Sensitivity a OFF b b a b OFF 2


OCR Scan
PDF TA8655AN 64-pin TA8655an sif 96 voltmeter sine wave inverter pic sine wave inverter using pic tcw7
2005 - 1Q 2005 Analog Applications Journal

Abstract:
Text: voltage can be seen with a high-impedance (>10 M) voltmeter or oscilloscope. When the oscilloscope probe , , the ADC readings change because the additional dc and ac paths affect the flying input voltage (see , measured with an external voltmeter is constant; it means that all these changes are self-compensated , dc voltage (in the 1- to 2.5-V range), and a dc voltmeter . The ADC input pin AINCOM should be , ) 644-5580 Fax support.ti.com/sc/ pic /americas.htm +1(972) 927-6377 Europe, Middle East, and Africa


Original
PDF MSC12xx MSC12xx MSC1210, MSC1211/1212/1213/1214, MSC1200/1201/1202, ADS1216 SLYT073 1Q 2005 Analog Applications Journal summator AC voltmeter pic MSC1212Y2 sbaa097 AVRG8 MSC1201 MSC1210 MSC1211
2008 - AC voltmeter pic

Abstract:
Text: similarities to the sensitive analog VSupply voltmeter and external shunt resistor 8 commonly used to measure current in the INA170 RG1 past. The analog voltmeter registered a 1 k VIN+ 2 small voltage , amplifier such as the INA326. However, the AC bandwidth will decrease and the cost will be higher , tiasia@ti.com or ti-china@ti.com Internet support.ti.com/sc/ pic /asia.htm Fax Internet/Email +1(972) 927-6377 support.ti.com/sc/ pic /americas.htm Europe, Middle East, and Africa Phone European


Original
PDF INA170 INA170 E093008 SLYT311 AC voltmeter pic dc pancake motor REF3225 OPA340 INA326 INA198 INA193 INA159 oscilloscope using pic
PIC Toolkit TK3 for Windows

Abstract:
Text: Special Feature PIC TOOLKIT TK3 FOR WINDOWS FR EE SU PP LE M EN T JOHN BECKER The long-awaited sequel to Toolkit Mk2, software crafted for PIC programming enthusiasts by a PIC programming addict. IC Toolkit TK3 for Windows is the most sophisticated EPE PIC microcontroller code , to play with reprogrammable PICs. The PIC families catered for are principally the PIC16x84 and , Supplement 1 PIC TOOLKIT TK3 FEATURES * Assembly of source code (ASM) written in TASM and MPASM


Original
PDF PIC16x84 PIC16F87x PIC Toolkit TK3 for Windows EPE PIC TUTORIAL V2 Assembler programming for PIC 16f877 EPE PIC TUTORIAL v2 part 1 EPE PIC TUTORIAL 3 EPE PIC TUTORIAL eeprom for pic 16f877 in assembly tutorial pic 16f877 ic pin details 7 segment display pic16f877 assembly example pic program
2005 - AC voltmeter pic

Abstract:
Text: Input) SCR Bridge ( AC to DC Converter) Power Interface Control ( PIC ) Board Bus Bars ( AC Output) DPI , Bars ( AC Input) Bus Bars ( AC Output) Power Interface Control ( PIC ) Board Control Board DPI , LiquiFlo 1.5 AC Power Modules Hardware Reference, Installation, and Troubleshooting Version 1.2 , and then check the voltage with a voltmeter to ensure the DC bus capacitors are discharged before , AC Line I/O Board Description


Original
PDF D2-3494-1 D2-3494-1­ AC voltmeter pic chemtool CT787-C trane FWD schneider transformer 750 kVA metasys 414 LEM DIODE CT787-C 1500 watts inverter diagrams Chemtool D2-3488
circuit diagram of Garage Door Openers

Abstract:
Text: the input and adjusting R2 until the output reads 1V rms on an ac voltmeter . Measurements show , OUTPUT PORTS FOR SIMULTANEOUS UPDATE PIC plots pixels sans controller DARYL CHRISTOPHER, JUNIATA , the It is sometimes desirable to display the LCD needs 8192 pixels at an approxioutput of a PIC C graphically, rather FIGURE 1 mate 70-MHz refresh rate, the PIC has than numerically. However, the operathe , to matching the PIC 's capayou can obtain a satisfactory plot (Figbilities to the task is recognizing


Original
PDF
2005 - picdem 2 plus demo board examples

Abstract:
Text: PIC ® microcontroller's internal RC oscillator is used as the system clock source. 1. Voltmeter This , , MPLAB, PIC , PICmicro, PICSTART, PRO MATE, PowerSmart, rfPIC, and SmartShunt are registered trademarks , regulator for direct input from 9V, 100 mA AC /DC wall adapter or test loops for a maximum of +5V, 100 mA , USART module to communicate with a Microwire EEPROM. The demo program uses the PIC ® microcontroller , Voltmeter mode is entered. © 2005 Microchip Technology Inc. DS51536A-page 12 PICDEMTM LCD


Original
PDF DS51536A pe34-8870 DS51536A-page picdem 2 plus demo board examples 4 digit digital voltmeter pic AC voltmeter pic digital thermometer PIC program digital voltmeter pic mplab icd 3 schematic tc77 mplab pm3 schematic PIC16C9XX PIC16F91X
2007 - Not Available

Abstract:
Text: , KEELOQ, KEELOQ logo, microID, MPLAB, PIC , PICmicro, PICSTART, PRO MATE, rfPIC and SmartShunt are , from 9V, 100 mA AC /DC wall adapter or 9V battery, or hooks for a +5V, 100 mA regulated DC supply â , MPLAB IDE. Other assemblers/compilers may be used. For a list of these PIC MCU compatible language , displayed on the LCD. 1. Voltmeter This mode uses the A/D module to measure the voltage of the R16 pot , sent to the LCD is also sent to the RS-232 serial port using the USART on the PIC MCU. A


Original
PDF DS51275D DS51275D-page
h48 diode zener

Abstract:
Text: ) 40A typical 30 Panel Meters AC Voltmeter Ì Large easy to read LED display Ì Screw terminal inputs , Voltmeter LCD, 8mm Digit Height Ì Ì Ì Ì Ì Ì 8mm character height 200mV dc full scale reading 150A @ 7.5 to , dc or 100 to 230V ac 12 to 48V dc 12 to 48V dc or 20 to 60V ac Termination Packard (2 Pin) / 2 Wire , - LCD Voltmeter Blue LED Backlight The SP 400-BLUE features a 200mV dc measurement range with , Digit LCD Voltmeter Ì 200mV Full Scale Reading Ì IP65 Splash-proof Ì Blue LED Backlighting Ì 9 Pin SIL


Original
PDF element-14 h48 diode zener Zener diode H48 D225 Diode zener DPM970 OEM24L MB111 DPM 160 Led digital panel meters C220VU ZENER h48
1978 - 939335

Abstract:
Text: to extend the voltage measuring capability of an ac /dc voltmeter up to 40,000 volts Overvoltage , . Specifications The 80K-40 will achieve rated accuracy when used with a voltmeter ( ac or dc) having an input , mechanically compatible with any ac or dc voltmeter or multimeter capable of accepting a standard spaced , electrically compatible with any ac or dc voltmeter or multimeter that has an input impedance of 10 M ±1%. , Voltage probe, is designed to extend the voltage measurement range of an ac /dc voltmeter up to 40,000


Original
PDF 80K-40 80K-40. 80K-40 80K-40: 939335 fluke 73 Repair manual AC voltmeter applications Fluke 111 Multimeter repair AC digital voltmeter diagram resistor kit 939335 AC voltmeter connection diagram Fluke 111 Multimeter AC voltmeter diagram free
DPM951

Abstract:
Text: DPMDCA DPMACV DPMDCV DPMLP AC Current Adaptor 0 to 2 AAC DC Current Adaptor 0 to 2 ADC AC Voltage , (0.24") Ordering Information HED271-R / DPM 961-R 24mm x 48mm Voltmeter HED271-T or TB/ DPM 961-T 24mm x 48mm Voltmeter with backlight (T green backlight TB blue backlight) HED272-R / DPM 962-R 36mm x 72mm Voltmeter HED272-T or TB/ DPM 962-T 36mm x 72mm Voltmeter with backlight (T green backlight , , DPM951, DPM961 HED281-R / DPM 951-R 24mm x 48mm Voltmeter HED281-T or TB/ DPM 951-T 24mm x 48mm


Original
PDF DPM961 HED271 DPM962 HED272 DPM951 HED281 DPM952 HED282 DPM951 AC voltmeter applications DPM952 DPM961 DPM962 961-R HED271 DPM95 HED282 HED272-T
2000 - FLUKE 8800A manual

Abstract:
Text: -P APPENDIX C UNDERSTANDING AND SELECTING RMS VOLTMETERS The choice of AC voltmeter is absolutely crucial for meaningful measurements. The AC voltmeter must respond faithfully to the RMS value of the , instrument requires care. The selection process begins with a basic understanding of AC voltmeter types.1 AC Voltmeter Types There are three basic AC voltmeter types. They include rectify and average , shows a more sophisticated AC voltmeter method. Here, the instantaneous value is (ideally) continuously


Original
PDF 100kHz AN83-19 AN83-20 FLUKE 8800A manual dc voltmeter circuit diagrams 4 way out HP3403C analog dc voltmeter circuit diagrams LT176x FLUKE 8800a ac voltmeter circuit diagrams HP3468B HP3455 1390-B
conn sil

Abstract:
Text: /2-Digit, LCD, AC Voltmeter , LED Backlit NEMA 4X Alloy Bezel (to fit 4 models above) PASSIVE & , individually or in packs of 10 for even greater savings. V1 LCD Voltmeter Module Function Digit Ht. (In.) 0.25 0.25 0.50 0.50 0.60 0.60 V125 LCD Voltmeter Module Size (In.) 1.50 × 0.55 1.50 × 0.55 1.97 × 0.80 1.97 × 0.80 2.36 × 1.50 2.36 × 1.50 Connection DIL DIL SIL SIL Edge Conn. Edge Conn. V600 LCD Voltmeter , 70101401 70101353 *Package of 10. LCD Voltmeter LCD Voltmeter , Pkg. of 10 Only LCD Voltmeter LCD Voltmeter


Original
PDF 31/2-digit 400-EB 750-EB, SP400-EB-W 750S-EB-W 700-IP conn sil voltmeter conn sil 2 lcd voltmeters 750-140 LED Backlit panel low voltage ac voltmeter operation of ac voltmeter lcd md640.400 8 way dip switch
2008 - ic 14070b

Abstract:
Text: Thermal Resistance, 24LD CERDIP θJA — N/A — °C /W Thermal Resistance,24LD SOIC Wide θJA — 70 — °C /W Thermal Resistance, 28LD PLCC θJA — 61.2 â , 100k ICLK - CLOCK FREQUENCY (% CHANGE) ICLK - CLOCK FREQUENCY (Hz) 0 TA - TEMPERATURE ( °C , TEMPERATURE ( °C ) CONVERSION RATE = CLOCK FREQUENCY ±1.5% 16,400 CONVERSION RATE = CLOCK , TYPICAL APPLICATIONS The typical application circuit is an example of a 3-1/2 digit voltmeter using


Original
PDF TC14433/A TC14433 1000M DS21394D-page ic 14070b
2007 - AC voltmeter pic

Abstract:
Text: , KEELOQ, KEELOQ logo, microID, MPLAB, PIC , PICmicro, PICSTART, PRO MATE, PowerSmart, rfPIC, and , View, California. The Company's quality system processes and procedures are for its PIC ® MCUs and , needed. 2. On-board adjustable voltage regulator for direct input from 9V, 100 mA AC /DC wall adapter or , device, with an In-Circuit Emulator (ICE) or with an In-Circuit Debugger (ICD). For a list of PIC , four components, which are individually displayed on the LCD. The PIC microcontroller's internal RC


Original
PDF DS51662A DS51662A-page AC voltmeter pic LCD connection to PIC18f 4 digit digital voltmeter pic circuit diagram of LCD connection to pic x35 lcd lm317 8 terminal lm317 datasheet for 5v to 3.3v picdem 2 plus demo board examples AC voltmeter with Digital Display diagram LM317 pin connection
digital 3 phase voltmeter and ammeter

Abstract:
Text: - Analog Panel Meters A, V, Hz Meter Three Display with 3 Parameters, Single Phase AC Ammeter, Voltmeter , IP20 -10 to +60 2kV 1 Three Display with 3 Parameters, Single Phase AC Ammeter, Voltmeter , required A Voltmeter GR48-3AV,GR72-3AV,GR96-3AV GR48-6AV,GR72-6AV,GR96-6AV 48x48 ,72x72, 96x96 AC , DC Voltmeter DC Frequency AC Greegoo Electric 3.2007 GR96-3PF1,GR96-3PF3 96x96 AC or DC , to 5A Voltmeter AC : 10V up to 600V 1A or 5A / 110V or 240V or 440V 1mA to 30A and with external


Original
PDF HCD19 IEC51 4--48X48 5--96X48 7--72X72 9--96X96 GR96-3PF3 GR96-3PF1 96x96 digital 3 phase voltmeter and ammeter AC digital voltmeter and ammeter 3 phase analog voltmeter and ammeter AC digital voltmeter digital 3 phase voltmeter WATT and ammeter analog panel meter digital phase voltmeter and ammeter digital Ammeter circuit GR72-3DV 230v AC voltmeter
2003 - the PIC Mid-Range Reference Manual DS33023 16

Abstract:
Text: Microchip name and logo, the Microchip logo, KEELOQ, MPLAB, PIC , PICmicro, PICSTART, PRO MATE and , .) 2. On-board +5V regulator for direct input from 9V, 100 mA AC /DC wall adapter or 9V battery, or , firmware is made up of two components, which are individually displayed on the LCD. The PIC ® microcontroller's internal RC oscillator is used as the system clock source. 1. Voltmeter This mode uses the A , TUTORIAL PROGRAM FLOW CHART Power-up "Microchip PICDEM 4" Voltmeter SW1 = Next SW3 = Now SW3


Original
PDF DS51337A DK-2750 D-85737 DS51337A-page the PIC Mid-Range Reference Manual DS33023 16 supercapacitor AC voltmeter pic LCD connection to PIC18f pic18f MCU Family Reference Manual PIC18XXXX PIC16 example codes lin transceiver pic16 family reference manual DS51268 DS39500
HP3478A

Abstract:
Text: 's law equation: | Z |= |V | |I| [3] I stimulus AC Zx V AC Voltmeter Figure 7 , external unknown capacitor. R TBIC ~ Function generator R ABM Cx V AC Voltmeter Figure , SCANSTA400 switch setup. AB2 V2 STA400 AC Voltmeter R Figure 9. IEEE 1149.4 implementation , ~ Measured Value (%) Within 5% Accuracy Cx V1 AC Voltmeter Figure 11. I-V method 120 100 , V A23 0 1 AC Voltmeter ABM AB1 10 100 1000 10000 100000 1000000


Original
PDF
2010 - PIC16F17

Abstract:
Text: , KEELOQ logo, MPLAB, PIC , PICmicro, PICSTART, PIC32 logo, rfPIC and UNI/O are registered trademarks of , are for its PIC ® MCUs and dsPIC® DSCs, KEELOQ® code hopping devices, Serial EEPROMs, microperipherals , adjustable voltage regulator for direct input from 9V, 100 mA AC /DC wall adapter or 3V button cell battery , , with an In-Circuit Emulator (ICE) or with an In-Circuit Debugger (ICD). For a list of PIC , individually displayed on the LCD. The PIC microcontroller's internal RC oscillator is used as the system


Original
PDF DS51662C DS51662C-page PIC16F17 VL_5573_V00 PIC16F1946 pic16f microcontroller rs232 pc AC voltmeter pic PIC16F946 DS51662 DS41414 VL5573_V00 RB369
2000 - THERMISTORS SCK 055

Abstract:
Text: OP AMP + 5 PRECISION RESISTORS + TRIMMING ( AC AND DC) LOCAL Instrumentation Amplifiers Part , + 2 R5 5k, 1% 6 LT1793 DC VOLTMETER INPUT 1mV TO 1000V R1 900k 0.1%, 1W , C1, 0.1µF 5V MAX LT1236CS8-5 6 2 OUT IN + 3-WIRE R-PACK 60Hz + AC INPUT , CH0 DC Voltage CH1 Electrometer CH2 AC Voltage CH3/CH4 AC /Audio/RF Power CH5 Temperature , PLC 3V/5V 3V/5V 68HC05 PIC LC 54 68L11 80L51 780XX MUX'D SERIAL OUT ADC PAGE 3


Original
PDF 100bps 16-bit 1-800-4-LINEAR THERMISTORS SCK 055 THERMISTOR ntc SCK 055 THERMISTORS SCK 053 thermistor SCK 085 LT1885 INFRARED THERMISTORS SCK 085 AC voltmeter pic LT1258 ntc linearization serial parallel LT1236CS8-5
GPT-515A

Abstract:
Text: - Model Output voltmeter Scales G PT-515A Common fo r AC /DC 1.5/5 kV FS GPT- 515AD , Resistors Required fo r Calibration 1. Voltm eter I: A voltmeter which is capable o f measuring 5 kV, AC (50 , subsequent explanation, the output voltage mode is not discriminated between AC and DC. Use a voltmeter and a , the 1.5 kV /5 kV ranges of AC /DC modes, check the indication o f the Tester voltmeter w ith the , . GENERAL The Withstanding Voltage Testers arc for both AC voltage and DC voltage testing, w ith an AC


OCR Scan
PDF GPT-515AD/GPT-515A GPT-515A GPT-515AD 515AD low voltage ac voltmeter t515a WIDS-515AD-H61-i3/R-R10
MR510

Abstract:
Text: by' measuring the ac component of V 0 with a true rms ac voltmeter and the dc component with a dc voltmeter . The data was used m Equation 1 to obtain points for the figure. For a sine wave input V m «in , ), AVERAGE FORWARD CURRENT T|_, L EA D T E M P E R A T U R E i aC ) vp. IN ST A N T A N EO U S FO R W A , N T IN G D A T A F IG U R E 11 - S T E A D Y - S T A T E T H E R M A L R E S IS T A N C E T Y PIC , increasing ac voitage component across R [_ which is opposite m polarity to the forward current, thereby


OCR Scan
PDF MR327 MR328 MR330 MR331 MR500 MR501 MR502 MR504 MR506 MR508 MR510 mr506 equivalent Diode MR510
1981 - FLUKE 87 diagram

Abstract:
Text: designed to convert a dc voltmeter into a high frequency (100 kHz to 500 MHz) ac voltmeter . Conversion from ac to dc is accomplished on a one-to-one basis and includes a range of 0.25 to 30V rms. The , . SPECIFICATIONS AC to DC RATIO: 1:1 RATIO ACCURACY: (At 25 MHz and loaded with 10 M e ) Above 0.5V: ± 0.5 dB , Probe Adapter, P/N 574756 VOLTMETER COMPATIBILITY The 85RF is compatible with any dc voltmeter that , . Connect the probe output to a compatible voltmeter using a suitable shunt if required. Probe output low


Original
PDF
Supplyframe Tracking Pixel