Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ZZY TVS Search Results

    ZZY TVS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DF2B20M4SL
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-18.5 V, SOD-962 (SL2) Datasheet
    DF2B6M4ASL
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) Datasheet
    DF2B7BSL
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) Datasheet
    DF2B7ASL
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) Datasheet
    DF2S6P2FU
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Unidirectional, 5.5 V, SOD-323 (USC) Datasheet

    Documents mentioning ZZY TVS

    Document Partial File Text Tags Type PDF
    thomson-csf
    cross reference «i liste d'é qu iva le nce THOMSON-CSF Comp, type n° THOMSON-CSF type Camp, type n° THOMSON-CSF type Comp, type n®' THOMSON-CSF type P6KE P6KE P6KE P6KE P6KE BZW06-136 BZW06-145 BZW06-154 BZW06-171 BZW06-5V8B TVS 528 TZB 6,8A TZB 7,5A
    OCR Scan PDF
    bzw06-97v2
    transient voltage suppressors «TRANSIL» '«!> diodes de protection «TRANSIL» THOMSON-CSF Types Ir M@Vr M Unidirec­ tional 600 W N N N N N N N N N N N N N N N N N N N N N N N Bidirec­ tional / BZW06-97V2 BZW06-102 BZW06-105 BZW06-111 BZW06-121 BZW06-128
    OCR Scan PDF
    transient voltage suppressors «TRANSIL», range
    transient voltage suppressors «TRANSIL», range for microprocessor, integrated circuit, C-MOS, MOS protection diodes de p ro te ctio n «TRANSIL», g a m m e p o u r la p ro te c tio n des ^ m icroprocesseurs, circuits in tég ré s, C -M O S , M O S V(B R )*@ lR
    OCR Scan PDF
    f\ transient voltage suppressor «TRANSIL»
    f\ transient voltage suppressor «TRANSIL» utilisations utilisations des diodes de protection «TRANSIL» thom son -c s f Recommended utilisations Utilisations recommandées Types General purpose Usage général Network protection Protection pour réseau
    OCR Scan PDF
    transient voltage suppressors «TRANSIL» diodes de
    transient voltage suppressors «TRANSIL» diodes de p rotection «TRANSIL» Types Bidirec­ tional 1 ms expo. / 1000 200 10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 1 ms expo. / PF8Z6V8 PF8Z8V2 PF8Z10 PF8Z12 PF8Z15 PF8Z18 PF8Z22 PF8Z27 PF8Z33 PF8Z39 PF8Z47 PF8Z56 PF8Z62
    OCR Scan PDF
    transient voltage suppressors «TRANSIL» diodes de
    transient voltage suppressors «TRANSIL» diodes de protection «TRANSIL» Unidirectional 5 KW Bidirectional / fcA) 1 ms expo. BZW 50-8V2 BZW 50-10 BZW 50-12 BZW 50-15 BZW 50-18 BZW 50-22 BZW 50-27 BZW 50-33 BZW 50-39 BZW 50-47 BZW 50-56 BZW 50-68 BZW 50-82
    OCR Scan PDF
    bzw04-45
    o transient voltage suppressors «TRANSIL» diodes de p rotection «TRANSIL» THOMSON-CSF T ypes U n id ire c ­ tio n a l 400 W N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 'R M @ V r m B id ire c ­ tio n a l / BZW04-45 BZW04-48 BZW04-50
    OCR Scan PDF
    transient voltage suppressors «TRANSIL» diodes de
    transient voltage suppressors «TRANSIL» diodes de protection «TRANSIL» U nidirectional 5 KW BZW BZW BZW BZW BZW BZW BZW BZW BZW BZW BZW BZW BZW BZW BZW BZW BZW B idirectional / @V r m fcA) 1 ms expo. 50-8V2 50-10 50-12 50-15 50-18 50-22 50-27 50-33 50-39
    OCR Scan PDF
    transient voltage suppressor «TRANSIL»
    transient voltage suppressor «TRANSIL» utilisations utilisations des diodes de protection «TRANSIL» f\ th o m s o n - csf Recommended utilisations Utilisations recommandées Types General purpose Usage général Netw ork protection Protection pour réseau
    OCR Scan PDF
    bzw04-5v5
    transient voltage suppressors «TRANSI!» diodes de protection «TRAN SIL» Types Unidirectional | 150 W / ■RM @ V r M Bidirectional fcA l N N N N N N N N N N N N N N N N N N N N N N BZW04-5V5 BZW04-5V8 BZW04-6V0 BZW04-6V4 BZW04-6V6 BZW04-7V0 BZW04-7V4 BZW04-7V8
    OCR Scan PDF
    bzw06-5v8
    transient voltage suppressors «TRANSIL» diodes de protection «TRANSIL» Types Unidirec­ tional 600 W N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 8ZW06-5V5 BZW06-5V8 BZW06-6V0 BZW06-6V4 BZW06-6V6 BZW06-7V0 BZW06-7V4 BZW06-7V8 BZW06-8V1 BZW06-8V5
    OCR Scan PDF
    bzw06-5v8
    transient voltage suppressors «TRANSIL» diodes de protection «TRAN SIL» Types Unidirec­ tional 600 W N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 8ZW06-5V5 BZW06-5V8 BZW06-6V0 BZW06-6V4 BZW06-6V6 BZW06-7V0 BZW06-7V4 BZW06-7V8 BZW06-8V1
    OCR Scan PDF
    connector series alpha-numeric index
    How to Order Connector Series Alpha-Numeric Index The following alpha-numeric list is provided as a convenience in identifying the various connector manufacturers' proprietary connector series designations applicable to the US and international specifications and docuMFG
    Original PDF
    How to Order Connector Series Alpha-Numeric Index
    How to Order Connector Series Alpha-Numeric Index The following alpha-numeric list is provided as a convenience in identifying the various connector manufacturers' proprietary connector series designations applicable to the US and international specifications and docuMFG
    Original PDF
    connector-backshell interface index
    How to Order Connector-Backshell Interface Index The following are lists of specifications and associated connector manufacturers' part number series with common rear accessory interfaces. These listings do not imply qualification status of the manufacturers indicated for each specification series. The listings are for
    Original PDF
    How to Order Connector-Backshell Interface Index
    How to Order Connector-Backshell Interface Index The following are lists of specifications and associated connector manufacturers' part number series with common rear accessory interfaces. These listings do not imply qualification status of the manufacturers indicated for each specification series. The listings are for
    Original PDF
    How to Order Connector Manufacturers' Index This
    How to Order Connector Manufacturers' Index This index of USA and international connector manufacturers provides a cross-reference of manufacturers' proprietary series designations to applicable specifications. This information does not imply qualification status but serves to indicate
    Original PDF
    connector manufacturers' index
    How to Order Connector Manufacturers' Index This index of USA and international connector manufacturers provides a cross-reference of manufacturers' proprietary series designations to applicable specifications. This information does not imply qualification status but serves to indicate
    Original PDF
    Amphenol 2010 Amphenol 12-C3 Circular
    Amphenol 2010 Amphenol 12-C3 Circular Interconnects Products for Military, Aerospace and Harsh Environments Circular Interconnects • Aluminum • Stainless Steel/Firewall • Composite • Printed Circuit Board Connectors • High Speed Connectors • EMI Filter/Transient
    Original PDF
    Amphenol 2010 Amphenol 12-C3 Circular
    Amphenol 2010 Amphenol 12-C3 Circular Interconnects Products for Military, Aerospace and Harsh Environments Circular Interconnects • Aluminum • Stainless Steel/Firewall • Composite • Printed Circuit Board Connectors • High Speed Connectors • EMI Filter/Transient
    Original PDF
    So You Want to Know Connectors… A REFERENCE GUIDE
    So You Want to Know Connectors… A REFERENCE GUIDE to Cylindrical Connectors Amphenol Contents This booklet is intended to be used as a ready reference to typical standard, miniature and subminiature cylindrical connector part numbers and terminology. Reading its brief pages will not
    Original PDF
    TABLE OF CONTENTS Amphenol Aerospace and Amphenol
    TABLE OF CONTENTS Amphenol Aerospace and Amphenol Industrial Operations Facilities/ Brief Product Overviews… 1-7 Amphenol®/Pyle®/Matrix® Quick Product Guides… 8, 9
    Original PDF
    Qwik Connect GLENAIR n A p ril 2011 n VOLUME 15 n
    Qwik Connect GLENAIR n A p ril 2011 n VOLUME 15 n NUMBER 2 Connector Reference Guide QwikConnect WELCOME INTERCONNECT PROFESSIONALS! Series 80 “Mighty Mouse” Connectors H igh performance MS type electrical connectors have been around since the late ’30s.
    Original PDF
    Qwik Connect GLENAIR n A p ril 2011 n VOLUME 15 n
    Qwik Connect GLENAIR n A p ril 2011 n VOLUME 15 n NUMBER 2 Connector Reference Guide QwikConnect WELCOME INTERCONNECT PROFESSIONALS! H igh performance MS type electrical connectors have been around since the late ’30s. As military and aerospace electronics became more prevalent and sophisticated, so did
    Original PDF
    Circular Connector Backshells and Accessories U n
    Circular Connector Backshells and Accessories U n i t e d S t a t e s „ U n i t e d K i n g d o m „ G e r m a n y „ F r a n c e „ N o r d i c „ I t a l y „ Spain Introducing the "NESTOR" (AS85049 Style "N" Coupling) Spring-Loaded, Positive-Lock Backshells
    Original PDF