Z0109 ST Search Results
Documents mentioning Z0109 ST
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| STEVAL-IHT005V2 Demonstration board with full 3.3 | STEVAL-IHT005V2 Demonstration board with full 3.3 V ACS/Triac control using the STM32F100 Data brief • IEC 61000-4-4 pre-compliance test passed (burst up to 8 kV) IEC 61000-4-5 pre-compliance test passed (surge up to 2 kV) RoHS compliant Description |
Original | ||||
| 2n7002 | 5 4 3 2 1 VCC3_AUX R1 VL 47K Modify1 D PWRSW SW1 1 3 2 4 Z0101 D Q1 G 2N7002 S 10K PWR_BTN VL 1632_OFF# Modify5 D R3 47K POWER SWITCH & LED_CON Q2 G R4 2N7002 Q4 Z0103 G S VCC3_AUX 2N7002 S Q3 G 2N7002 D D Z0102 S INTMIC_GND INTMIC 1 2 3 4 5 6 7 8 9 10 11 |
Original | ||||
| Z01 Series 1A TRIACS STANDARD MAIN FEATURES: A2 | Z01 Series 1A TRIACS STANDARD MAIN FEATURES: A2 Symbol Value Unit IT(RMS) 1 A V DRM/VRRM 600 to 800 V IGT (Q ) 1 3 to 25 mA G A1 A2 A1 DESCRIPTION The Z01 series is suitable for general purpose AC switching applications. They can be found in applications |
Original | ||||
| Z01 Series ® 1A TRIACS STANDARD MAIN FEATURES: A2 | Z01 Series ® 1A TRIACS STANDARD MAIN FEATURES: A2 Symbol Value Unit IT(RMS) 1 A VDRM/VRRM 600 to 800 V IGT (Q1) 3 to 25 mA G A1 A2 A1 DESCRIPTION The Z01 series is suitable for general purpose AC switching applications. They can be found in applications such |
Original | ||||
| Z01 Series ® 1A TRIACS STANDARD MAIN FEATURES: A2 | Z01 Series ® 1A TRIACS STANDARD MAIN FEATURES: A2 Symbol Value Unit IT(RMS) 1 A VDRM/VRRM 600 to 800 V IGT (Q ) 1 3 to 25 mA G A1 A2 A1 DESCRIPTION The Z01 series is suitable for general purpose AC switching applications. They can be found in applications |
Original | ||||
| Z01 Series ® 1A TRIACS STANDARD MAIN FEATURES: A2 | Z01 Series ® 1A TRIACS STANDARD MAIN FEATURES: A2 Symbol Value Unit IT(RMS) 1 A VDRM/VRRM 600 to 800 V IGT (Q1) 3 to 25 mA G A1 A2 A1 DESCRIPTION The Z01 series is suitable for general purpose AC switching applications. They can be found in applications such |
Original | ||||
| Z01 Series ® 1A TRIACS STANDARD MAIN FEATURES: A2 | Z01 Series ® 1A TRIACS STANDARD MAIN FEATURES: A2 Symbol Value Unit IT(RMS) 1 A VDRM/VRRM 600 to 800 V IGT (Q1) 3 to 25 mA G A1 A2 A1 DESCRIPTION The Z01 series is suitable for general purpose AC switching applications. They can be found in applications such |
Original | ||||
| electrovalve | Z01 ® 1A TRIACS STANDARD Table 1: Main Features A2 Symbol Value Unit IT(RMS) 1 A VDRM/VRRM 600 to 800 V IGT (Q1) 3 to 25 mA G A1 A2 A1 DESCRIPTION The Z01 series is suitable for general purpose AC switching applications. They can be found in applications such as home appliances (electrovalve, |
Original | ||||
| Z01 SERIES Standard 1A Triacs Features ■ On-state | Z01 SERIES Standard 1A Triacs Features ■ On-state rms current, IT(RMS) 1 A ■ Repetitive peak off-state voltage, VDRM/VRRM 600 or 800 V ■ Triggering gate current, IGT (Q1) 3 to 25 mA SOT-223 Z01xxN TO-92 Z01xxA Description The Z01 series is suitable for general purpose AC |
Original | ||||
| Z01 ® 1A TRIACS STANDARD Table 1: Main Features | Z01 ® 1A TRIACS STANDARD Table 1: Main Features A2 Symbol Value Unit IT(RMS) 1 A VDRM/VRRM 600 to 800 V IGT (Q1) 3 to 25 mA G A1 A2 A1 DESCRIPTION The Z01 series is suitable for general purpose AC switching applications. They can be found in applications such as home appliances (electrovalve, |
Original | ||||
| Z01 Standard 1 A Triacs Main Features A2 Symbol | Z01 Standard 1 A Triacs Main Features A2 Symbol Value Unit IT(RMS) 1 A VDRM/VRRM 600 to 800 V IGT (Q1) 3 to 25 mA G A1 A2 G Description A1 The Z01 series is suitable for general purpose AC switching applications. They can be found in applications such as home appliances |
Original | ||||
| zxxx | THYRISTORS TRIACs D2PAK DPAK SOT-223 SURFACE MOUNT TRIACs Tj max = 125 °C (except for Zxxx series: 110 °C) IT(RMS) TC VRRM VDRM I II + + +- Part Number (A) IGT ITSM IH III -- Package max max min min min (mA) (V) (A) (A/ms) (V/µs) (V/µs) 5 7 1.5 1.1 0.44 |
Original | ||||
| Z01 Standard 1A Triacs Features A2 ■ On-state rms | Z01 Standard 1A Triacs Features A2 ■ On-state rms current, IT(RMS) 1 A ■ Repetitive peak off-state voltage, VDRM/VRRM 600 or 800 V ■ G A1 A2 Triggering gate current, IGT (Q1) 3 to 25 mA Description G The Z01 series is suitable for general purpose AC |
Original | ||||
| Z01 Standard 1 A Triacs Main Features A2 Symbol | Z01 Standard 1 A Triacs Main Features A2 Symbol Value Unit IT(RMS) 1 A VDRM/VRRM 600 to 800 V IGT (Q1) 3 to 25 mA G A1 A2 G Description A1 The Z01 series is suitable for general purpose AC switching applications. They can be found in applications such as home appliances |
Original | ||||
|
|
||||||
| Z01 Standard 1A Triacs Features A2 ■ On-state rms | Z01 Standard 1A Triacs Features A2 ■ On-state rms current, IT(RMS) 1 A ■ Repetitive peak off-state voltage, VDRM/VRRM 600 or 800 V ■ G A1 A2 Triggering gate current, IGT (Q1) 3 to 25 mA Description G The Z01 series is suitable for general purpose AC |
Original | ||||
| APPLICATION NOTE THE NEW ACS™ SERIES: A | APPLICATION NOTE THE NEW ACS™ SERIES: A BREAKTHROUGH IN RUGGEDNESS & DRIVE FOR HOME APPLIANCES L. Gonthier INTRODUCTION Home appliances such as washing machines, refrigerators and dishwashers use a lot of low power loads such as valves, door lock systems, dispensers or drain pumps. Since these loads are powered by the |
Original | ||||
| APPLICATION NOTE ® THE NEW ACS™ SERIES: A | APPLICATION NOTE ® THE NEW ACS™ SERIES: A BREAKTHROUGH IN RUGGEDNESS & DRIVE FOR HOME APPLIANCES L. Gonthier INTRODUCTION Home appliances such as washing machines, refrigerators and dishwashers use a lot of low power loads such as valves, door lock systems, dispensers or drain pumps. Since these loads are powered by the |
Original | ||||
| triacs | Z01 Standard 1A Triacs Features A2 ■ On-state rms current, IT(RMS) 1 A ■ Repetitive peak off-state voltage, VDRM/VRRM 600 or 800 V ■ G A1 A2 Triggering gate current, IGT (Q1) 3 to 25 mA Description G The Z01 series is suitable for general purpose AC |
Original | ||||
| an1172 | AN1172 Application note ACS™ A logic-level transient-voltage protected AC switch Introduction Home appliances such as washing machines, refrigerators and dishwashers employ a lot of low power loads such as valves, door lock systems, dispensers or drain pumps. Since these |
Original | ||||
| an437 | AN437 Application note RC snubber circuit design for TRIACs Introduction When a TRIAC controls inductive loads, the mains voltage and the load current are not in phase. To limit the slope of the reapplied voltage and ensure right TRIAC turn-off, designer usually used a snubber circuit connected in parallel with the TRIAC. This circuit can also be |
Original | ||||
| lp200t | PREFACE P R E F A C E Service Manual LCD PC LP200C/LP200T I PREFACE NOTICE R E F A C E The company reserves the right to revise this publication or to change its contents without notice. Information contained herein is for reference only and does not constitute a commitment on the part of the manufacturer or any |
Original | ||||
| l287s | Preface LCD Computer L287S Service Manual Preface I Preface Notice The company reserves the right to revise this publication or to change its contents without notice. Information contained herein is for reference only and does not constitute a commitment on the part of the manufacturer or any subsequent vendor. They assume no responsibility or liability for any errors or inaccuracies that may appear in this publication nor are |
Original | ||||
| lp200 | PREFACE SERVICE MANUAL LCD PC LP200SC/LP200ST I SERVICE MANUAL NOTICE The company reserves the right to revise this publication or to change its contents without notice. Information contained herein is for reference only and does not constitute a commitment on the part of the manufacturer or any subsequent vendor. They assume |
Original | ||||
| l285p | Preface LCD Computer L285P Service Manual Preface I Preface Notice The company reserves the right to revise this publication or to change its contents without notice. Information contained herein is for reference only and does not constitute a commitment on the part of the manufacturer or any subsequent vendor. They assume no responsibility or liability for any errors or inaccuracies that may appear in this publication nor are |
Original | ||||
| l285s | Preface LCD Computer L285S Service Manual Preface I Preface Notice The company reserves the right to revise this publication or to change its contents without notice. Information contained herein is for reference only and does not constitute a commitment on the part of the manufacturer or any subsequent vendor. They assume no responsibility or liability for any errors or inaccuracies that may appear in this publication nor are |
Original | ||||