Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    X-RAY INSPECTION Search Results

    X-RAY INSPECTION Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    AFE0256GBTD
    Texas Instruments 256-Channel Analog Front-End for Flat-Panel Digital X-ray Detector 0- 0 to 85 Visit Texas Instruments Buy
    AFE1256GBTD
    Texas Instruments 256-Channel Analog Front-End for Flat-Panel Digital X-ray Detector 0- 0 to 85 Visit Texas Instruments
    AFE0064IPBKR
    Texas Instruments 64 Channel Analog Front End for Digital X-Ray Detector 128-LQFP -40 to 85 Visit Texas Instruments Buy
    AFE2257TDU
    Texas Instruments 256-channel analog front end (AFE) for digital X-ray flat-panel detectors 320-COF 0 to 85 Visit Texas Instruments Buy
    AFE0064IPBK
    Texas Instruments 64 Channel Analog Front End for Digital X-Ray Detector 128-LQFP -40 to 85 Visit Texas Instruments Buy

    X-RAY INSPECTION Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    VICTOREEN model 500

    Abstract: intensifier phosphor p20 VICTOREEN V3732P image intensifier -X-ray image intensifiers cesium iodide iodide V3733P
    Contextual Info: X-RAY IMAGE INTENSIFIERS High DQE • Excellent Image Quality • High Contrast An X-ray image intensifier is a large image tube that converts a low intensity X-ray image into a visible image. It is used for medical X-ray TV systems, X-ray nondestructive inspection systems,


    Original
    s-1641004e03victoreen model 500intensifier+8phosphor p20victoreenv3732pimage intensifier -x-rayimage intensifierscesium iodideiodidev3733p PDF

    x-ray tube

    Abstract: TLSOB0102EA IEC61326 L10321 xray microfocus x-ray X-RAY INSPECTION x-ray tube datasheet C7716 C7716-10
    Contextual Info: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10321 TLSOF0185 FEATURES APPLICATIONS ●Wide X-ray Beam Angle: 118 ° ●Short FOD Focus to Object Distance : 7.3 mm ●Non-destructive Inspection ●X-ray CT ●In-line X-ray Inspection ●Focal Spot Size: 5 µm (at 4 W)


    Original
    l10321tlsof0185se-171-41tlso1058e03+9x-ray tubetlsob0102eaiec61326xraymicrofocus x-rayx-ray inspectionx-ray tube datasheetc7716c7716-10 PDF

    L9191

    Abstract: L9181 L9181-02 HAMAMATSU L9191 X-RAY INSPECTION AC Photonics C7336 C7716 C7876-10 l919
    Contextual Info: X-RAY I.I. CAMERA UNIT SERIES X-RAY C7336-50/-51, C7876/-10, C7716/-10 IMAGING X-ray Image Intensifier X-ray I.I. + CCD Camera High-quality X-ray images. Both low energy and high magnification are available. ▲Flower (C7876, X-ray tube voltage: 10 kV) ▲BGA


    Original
    c7336-50/-51c7876/-10c7716/-10c7876+11c7716lc7336-50/-51l9191l9181l9181-02hamamatsu l9191x-ray inspectionac photonicsc7336c7876-10l919 PDF

    Contextual Info: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10321 TLSOF0185 FEATURES APPLICATIONS ●Wide X-ray Beam Angle: 118 ° ●Short FOD Focus to Object Distance : 7.3 mm ●Non-destructive Inspection ●X-ray CT ●In-line X-ray Inspection ●Focal Spot Size: 5 µm (at 4 W)


    Original
    l10321tlsof0185se-171-41txpr1013e01 PDF

    car front camera

    Abstract: x-ray x-ray tube 20kv solid relay x-ray tube datasheet C7077 C7716 C7716-10 C7876-10 X-RAY thickness
    Contextual Info: X-RAY I.I. CAMERA UNIT C7876, C7876-10 NEW 4” X-ray Image Intensifier with Beryllium Window Efficiently Coupled to CCD Camera Captures low-energy X-ray images in real time! The C7876 series X-ray image intensifier X-ray I. I. camera units are ideal for non-destructive inspection of light-element


    Original
    c7876c7876-10se-171-411047e01+9car front camerax-rayx-ray tube20kv solid relayx-ray tube datasheetc7077c7716c7716-10x-ray thickness PDF

    Contextual Info: 110 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9631 Optimum for In-line X-ray Inspection System FEATURES ●High Output: 800 µA 50 W It allows continuous maximum output. ●High Stability ●Serial Port Control (RS-232C) One package of a sealed type X-ray tube, a high-voltage power


    Original
    l9631rs-232cse-171-41txpr1014e01 PDF

    Contextual Info:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    h8480/h8481/h8953h8480h8481h8953+2se-171-41tapp1056e02 PDF

    x-ray

    Abstract: 3 ccd progressive scan C7336-03 AC Photonics interline sharp CCD Camera C7716 "frame grabber"
    Contextual Info: X-RAY I.I. DIGITAL CAMERA X-RAY UNIT SERIES IMAGING C7336-03/-04 OVERVIEW The C7336-03/04 consist of a high resolution, high contrast 4-inch X-ray image intensifier X-ray I.I. and a 1.45 megapixel digital CCD camera. The X-ray I.I. used has a fixed field-of-view of 100


    Original
    c7336-03/-04c7336-03/04se-171-411053e02+8x-ray3 ccd progressive scanc7336-03ac photonicsinterlinesharp ccd camerac7716frame grabber PDF

    X-RAY thickness

    Abstract: x-ray tube L9631 X-RAY INSPECTION x-ray tube datasheet t6.3a 250v microfocus x-ray x-ray x-ray tube operation C7716-10
    Contextual Info: 110 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9631 Optimum for In-line X-ray Inspection System FEATURES ●High Output: 800 µA 50 W It allows continuous maximum output. ●High Stability ●Serial Port Control (RS-232C) One package of a sealed type X-ray tube, a high-voltage power


    Original
    l9631rs-232cse-171-41tlso1053e05+9x-ray thicknessx-ray tubex-ray inspectionx-ray tube datasheett6.3a 250vmicrofocus x-rayx-rayx-ray tube operationc7716-10 PDF

    Contextual Info: X-RAY I.I. DIGITAL CAMERA X-RAY UNIT SERIES IMAGING C7336-05/-52 •BGA ●Digital type C7336-05 Clear, Sharp Image X-ray tube voltage: 80 kV ●Analog type OVERVIEW The C7336 series consist of a high resolution, high contrast 4inch X-ray image intensifier (X-ray I.I.) and a 2.8 megapixel


    Original
    c7336-05/-52c7336-05c7336ieee1394b+3se-164txpr1017e04b1201 PDF

    x-ray tube

    Abstract: AC Photonics H8953 scintillator x-ray tube datasheet H8480 H8481 H8481-15 rear CCD camera VA-033B
    Contextual Info:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    h8480/h8481/h8953h8480h8481h8953+9se-171-41tapp1056e02x-ray tubeac photonicsscintillatorx-ray tube datasheeth8481-15rear ccd camerava-033b PDF

    Contextual Info:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    h8480/h8481/h8953h8480h8481h8953+325tewinse-164txpr1020e01 PDF

    Contextual Info: IMAGE SENSOR Flat panel sensor C7942, C7943 Acquire digital X-ray image in real time and 170 & 176 mm diagonal size Hamamatsu C7942 and C7943 Flat Panel Sensors are digital X-ray image sensors newly developed as key devices for non-destructive inspection, biomedical imaging, X-ray microscopy and other real-time X-ray imaging applications requiring high resolution and high image quality.


    Original
    c7942c7943se-171kacc1056e09 PDF

    lemo connector

    Abstract: LEMO A8406-01 TX20A-36R-D2GF1 C7942 C7943 PCS-XEM100LU2
    Contextual Info: IMAGE SENSOR Flat panel sensor C7942, C7943 Acquire digital X-ray image in real time and 170 & 176 mm diagonal size Hamamatsu C7942 and C7943 Flat Panel Sensors are digital X-ray image sensors newly developed as key devices for non-destructive inspection, biomedical imaging, X-ray microscopy and other real-time X-ray imaging applications requiring high resolution and high image quality.


    Original
    c7942c7943se-171kacc1056e08+5lemo connectorlemoa8406-01tx20a-36r-d2gf1pcs-xem100lu2 PDF

    Contextual Info: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-02 FEATURES ● Focal Spot Size: 5 µm at 4 W Sealed type X-ray tube with 5 µm focal spot allows clear X-ray images even at a high magnification. ●Easy Handling Fully operable from external PC. ●Serial Port Control (RS-232C)


    Original
    l9181-02rs-232cse-171-41txpr1015e01 PDF

    BICRON surveyor 2000

    Abstract: BICRON surveyor M BICRON 1M preset, horizontal microfocus x-ray L6731-01 VICTOREEN dispenser cathode ion chamber X-RAY INSPECTION
    Contextual Info: 80kV TYPE : L6731-01 / 130kV 8 µm MICROFOCUS X-RAY SOURCE TYPE : L6622-01 300 µm CONVENTIONAL X-RAY SOURCE X-RAY FOCAL SPOT D1 OBJECT D2 CLEAR IMAGE Target Voltage:45kV x10 Target Voltage:70kV ×100 INDISTINCT IMAGE Target Voltage:70kV ×6 In X-ray imaging, the magnification and resolution are


    Original
    l6731-01130kvl6622-01se-171-41+101026e02bicron surveyor 2000bicron surveyor mbicron1m preset, horizontalmicrofocus x-rayvictoreendispenser cathodeion chamberx-ray inspection PDF

    image sensor x-ray

    Abstract: x-ray tube csi fop SERVICE MANUAL tv sony scintillator H8480-03 x-ray sensor H8481-06 sony tv service manual H8480
    Contextual Info: X-CUBE NEW COMPACT X-RAY CCD CAMERAS H8480 Series SAMPLE X-RAY IMAGES Sample: Digital camera memory media X-ray tube voltage: 80 kV p X-ray tube current: 100 µA H8481 H8480 High Resolution Type Effective area: 25 mm Min. Resolution : 8 Lp/mm Effective area: 8.8 mm x 6.6 mm


    Original
    h8480h8481se-171-41tmcp1029e02+9image sensor x-rayx-ray tubecsi fopservice manual tv sonyscintillatorh8480-03x-ray sensorh8481-06sony tv service manual PDF

    C7942

    Abstract: C7943 A8406-02 ecg replacement guide 36ph1 A8406-01 x-ray sensor LEMO 00 connectors
    Contextual Info: IMAGE SENSOR Flat panel sensor C7942, C7943 Acquire digital X-ray image in real time and 170 & 176 mm diagonal size Hamamatsu C7942 and C7943 Flat Panel Sensors are digital X-ray image sensors newly developed as key devices for non-destructive inspection, biomedical imaging, X-ray microscopy and other real-time X-ray imaging applications requiring high resolution and high image quality.


    Original
    c7942c7943se-171kacc1056e10+6a8406-02ecg replacement guide36ph1a8406-01x-ray sensorlemo 00 connectors PDF

    Contextual Info: XStation MX Automated X-Ray Inspection System Revolutionary multi-angle X-ray solution provides maximum coverage, throughput, and reliability using ClearVue™ and TraX™ technologies KEY FEATURES • Multi-angle X-ray inspection designed for: high-complexity PCBs, high-product


    Original
    atd-06-06-07 PDF

    L9421-02

    Abstract: L9421 x-ray tube datasheet sharp ccd x-ray C7716 C7716-10 C7876-10 H8480 H8953
    Contextual Info: 90 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9421-02 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube enables sharp and clear X-ray images even at a high magnification. ●Easy Handling Fully operable from an external PC.


    Original
    l9421-02rs-232cse-171-41tlso1055e03+9l9421x-ray tube datasheetsharp ccdx-rayc7716c7716-10c7876-10h8480h8953 PDF

    Contextual Info: 90 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9421-02 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube enables sharp and clear X-ray images even at a high magnification. ●Easy Handling Fully operable from an external PC.


    Original
    l9421-02rs-232cse-171-41txpr1011e01 PDF

    HAMAMATSU L9181

    Abstract: L9181-02 intensifier x-ray tube L9181 X-RAY thickness IEC61326 L9181 x-ray x-ray tube datasheet C7716
    Contextual Info: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-02 FEATURES ●Focal Spot Size: 5 µm at 4 W Sealed type X-ray tube with 5 µm focal spot allows clear X-ray images even at a high magnification. ●Easy Handling Fully operable from external PC. ●Serial Port Control (RS-232C)


    Original
    l9181-02rs-232cse-171-41tlso1061e01+9hamamatsu l9181intensifierx-ray tube l9181x-ray thicknessiec61326l9181x-rayx-ray tube datasheetc7716 PDF

    Contextual Info: IMAGE SENSOR CCD area image sensor S7361 Front-illuminated FFT-CCDs for X-ray imaging S7361 is a family of FFT-CCD image sensors specifically designed for X-ray imaging. FOS Fiber Optic plate with Scintillator that converts X-ray into visible-light is mounted on a CCD chip, which enables S7361 to do the X-ray imaging.


    Original
    s7361se-171kmpd1046e01 PDF

    LEMO

    Abstract: LEMO FGG.2B bio-chemical sensor x-ray cmos image sensor LEMO 5 pin out TX20A-36PH1-D2P1-D1E TX20A-36R-D2GF1 C7942CK-12 LEMO 7 pin ecg replacement guide
    Contextual Info: IMAGE SENSOR Flat panel sensor C7942CK-12 Acquire digital X-ray image in real time and 170 mm diagonal size Flat panel sensors C7942CK-12 is a digital X-ray image sensor newly developed as a key device for biochemical imaging, X-ray microscopy and other real-time X-ray imaging applications requiring high resolution and high image quality.


    Original
    c7942ck-1212-bitse-171kacc1114e05+9lemolemo fgg.2bbio-chemical sensorx-ray cmos image sensorlemo 5 pin outtx20a-36ph1-d2p1-d1etx20a-36r-d2gf1lemo 7 pinecg replacement guide PDF