WR137 WAVEGUIDE Search Results
WR137 WAVEGUIDE Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
|
Contextual Info: WAVEGUIDE TUBE Rigid Rectangle Waveguide Tube Material WR650 to WR75 Waveguide Type WR650 WR510 WR430 WR340 WR284 WR284 WR229 WR229 WR187 WR187 WR159 WR159 WR137 WR137 WR112 WR112 WR90 WR90 WR75 WR75 Freq. Range GHz 1.12-1.70 1.45-2.20 1.70-2.60 2.20-3.30 |
Original |
wr650wr510wr430wr340+3 | |
|
Contextual Info: FLEXIBLE TWIST WAVEGUIDE Flexible Twist Waveguide P/N Freq. GHz Waveguide 4.90-7.05 159FLEXTW 137FLEXTW 112FLEXTW 5.725-6.425 1.10 5.85-8.20 1.15 5.85-6.425 1.10 6.425-7.125 WR137 1.10 7.125-7.725 1.10 7.725-8.20 1.10 7.05-10.0 1.15 7.125-7.725 WR112 1.10 |
Original |
159flextwwr137wr11290flextw+5 | |
WR284 flange
Abstract: WR112 flange WR137 flange WR75 waveguide microwave waveguide WR62 UBR120 WR-75 UBR-120 WR90 flange
|
Original |
wg11awr284wr229wr187+13 | |
|
Contextual Info: WAVEGUIDE CROSS COUPLER CW-XX Type WR430 to WR90 P/N 430CCW X 340CCW X 284CCW X 229CCW X 187CCW X 159CCW X 137CCW X Freq. Range GHz W avegui de 1.702.60 2.203.30 2.603.95 3.304.90 3.955.85 4.907.05 5.588.20 WR430 WR340 WR284 WR229 WR187 WR159 WR137 Band |
Original |
wr430430ccw340ccw284ccw+5 | |
cpr112
Abstract: CPR-112 UBR100 flange UBR220 WR137 flange WR284 in mm 51sb WR137 CPR-284F WR159
|
Original |
wr137wr284wg11awr229+12 | |
JPW4-07250775-45K-S
Abstract: wr112 waveguide
|
Original |
11-sectionwr137wr112jpw4-07250775-45k-s+4 | |
|
Contextual Info: Flange Availability Waveguide Size WR28 WR42 Choke • Cover • WR112 WR137 WR62 WR75 WR90 • • • • • • • • • • • • • • CPR G • • • • • • CPR( )F • • • • • • CMR • • • • • • • • • Flange Type |
OCR Scan |
wr112wr137wr159wr187+1 | |
dBm150Contextual Info: ULTRA-LOW NOISE X-BAND SATCOM LNA FEATURES • Noise temperatures from 45 K • 7.25 to 7.75 GHz operation • Integrated 11-section transmit reject filter • WR137 or WR112 waveguide input with moisture seal JPW4-07250775-45K-S Fully militarized, this amplifier is supplied in a rugged chassis complete with an integrated fault alarm circuit and |
Original |
wr137wr11211-sectionjpw4-07250775-45k-s+4 | |
WR137Contextual Info: WR-137 Commercial Grade Straight Waveguide Section 6 Inch Length with CPR-137G Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137S002-6 Pasternack’s waveguide sections are constructed of a high quality copper alloy designed to provide VSWR as low as 1.03:1. |
Original |
wr-137cpr-137gpe-w137s002-6wr-12+1 | |
|
Contextual Info: WR-137 Commercial Grade Straight Waveguide Section 9 Inch Length with UG-344/U Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137S001-9 Pasternack’s waveguide sections are constructed of a high quality copper alloy designed to provide VSWR as low as 1.03:1. |
Original |
wr-137ug-344/upe-w137s001-9wr-12 | |
|
Contextual Info: WR-137 Commercial Grade Straight Waveguide Section 9 Inch Length with CPR-137G Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137S002-9 Pasternack’s waveguide sections are constructed of a high quality copper alloy designed to provide VSWR as low as 1.03:1. |
Original |
wr-137cpr-137gpe-w137s002-9wr-12 | |
|
Contextual Info: WR-137 to SMA Female Waveguide to Coax Adapter 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE9830 WR-137 to SMA Female Waveguide to Coax Adapter 5.85 GHz to 8.2 GHz Configuration Waveguide Interface RF Connector RF Connector Impedance WR-137 SMA Female 50 Ohms |
Original |
wr-137pe9830r-137-sma-female-waveguide-coax-adapter-585-ghz-8+1 | |
|
Contextual Info: WR-137 Waveguide H-Bend with CPR-137G Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137B004 Electrical Specifications Description Frequency Range Minimum Typical 5.85 Maximum Units 8.2 GHz VSWR 1.08:1 Insertion Loss 0.15 dB . Mechanical Specifications |
Original |
wr-137cpr-137gpe-w137b004 | |
|
Contextual Info: WR-137 Waveguide H-Bend with UG-344/U Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137B002 Electrical Specifications Description Frequency Range Minimum Typical 5.85 Maximum Units 8.2 GHz VSWR 1.08:1 Insertion Loss 0.15 dB . Mechanical Specifications |
Original |
wr-137ug-344/upe-w137b002 | |
|
|
|||
|
Contextual Info: WR-137 Waveguide E-Bend with UG-344/U Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137B001 Electrical Specifications Description Frequency Range Minimum Typical 5.85 Maximum Units 8.2 GHz VSWR 1.08:1 Insertion Loss 0.15 dB . Mechanical Specifications |
Original |
wr-137ug-344/upe-w137b001 | |
|
Contextual Info: WR-137 Commercial Grade Straight Waveguide Section 3 Inch Length with CPR-137G Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137S002-3 Pasternack’s waveguide sections are constructed of a high quality copper alloy designed to provide VSWR as low as 1.03:1. |
Original |
wr-137cpr-137gpe-w137s002-3wr-12 | |
|
Contextual Info: WR-137 Commercial Grade Straight Waveguide Section 12 Inch Length with CPR-137G Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137S002-12 Pasternack’s waveguide sections are constructed of a high quality copper alloy designed to provide VSWR as low as 1.03:1. |
Original |
wr-137cpr-137gpe-w137s002-12wr-12 | |
|
Contextual Info: WR-137 Commercial Grade Straight Waveguide Section 3 Inch Length with UG-344/U Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137S001-3 Pasternack’s waveguide sections are constructed of a high quality copper alloy designed to provide VSWR as low as 1.03:1. |
Original |
wr-137ug-344/upe-w137s001-3wr-12 | |
|
Contextual Info: WR-137 Commercial Grade Straight Waveguide Section 12 Inch Length with UG-344/U Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137S001-12 Pasternack’s waveguide sections are constructed of a high quality copper alloy designed to provide VSWR as low as 1.03:1. |
Original |
wr-137ug-344/upe-w137s001-12wr-12 | |
|
Contextual Info: WR-137 Waveguide E-Bend with CPR-137G Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137B003 Electrical Specifications Description Frequency Range Minimum Typical 5.85 Maximum Units 8.2 GHz VSWR 1.08:1 Insertion Loss 0.15 dB . Mechanical Specifications |
Original |
wr-137cpr-137gpe-w137b003 | |
|
Contextual Info: WR-137 to N Female Grooved Waveguide to Coax Adapter 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE9876 Configuration Waveguide Interface Flange Design RF Connector RF Connector Impedance WR-137 Grooved N Female 50 Ohms Electrical Specifications Frequency Range, GHz |
Original |
wr-137pe9876/wr-137-n-female-waveguide-coax-adapter-52-ghz-grooved-pe9876-p | |
|
Contextual Info: WR-137 Commercial Grade Straight Waveguide Section 6 Inch Length with UG-344/U Flange Operating from 5.85 GHz to 8.2 GHz TECHNICAL DATA SHEET PE-W137S001-6 Pasternack’s waveguide sections are constructed of a high quality copper alloy designed to provide VSWR as low as 1.03:1. |
Original |
wr-137ug-344/upe-w137s001-6wr-12 | |
low loss waveguide WR-90
Abstract: WR284 in mm WR284* ISOLATOR high power waveguide isolators I-I428L-I0I WR187 waveguide I-I526L-I0I WR 284
|
OCR Scan |
wr-284wr-42m26l-i0ii-i630l-i0i+12 | |
WR137 flange dimensions
Abstract: WR137 gasket dimensions WR137 flange WR75
|
OCR Scan |
wr137crp137gcpr137gwr159+5 | |