WIRE WOUND IR SOURCE Search Results
WIRE WOUND IR SOURCE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| MP-5XRJ11PPXS-014 | Amphenol Cables on Demand | Amphenol MP-5XRJ11PPXS-014 Flat Silver Satin Modular Crossed wiring Cable, RJ11 / RJ11 14ft | |||
| MP-64RJ4528GG-003 | Amphenol Cables on Demand | Amphenol MP-64RJ4528GG-003 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - Green 3ft | |||
| MP-64RJ4528GK-014 | Amphenol Cables on Demand | Amphenol MP-64RJ4528GK-014 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - Black 14ft | |||
| MP-64RJ4528GW-007 | Amphenol Cables on Demand | Amphenol MP-64RJ4528GW-007 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - White 7ft | |||
| MP-6A28GNSBLK-007 | Amphenol Cables on Demand | Amphenol MP-6A28GNSBLK-007 Slim Category-6a (Thin CAT6a) UTP 28-AWG Network Patch Cable (650-MHz) with Snagless RJ45 Connectors - Black 7ft |
Documents mentioning WIRE WOUND IR SOURCE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| flyback transformer design | ® Flyback Transformer Design For TOPSwitch® Power Supplies Application Note AN-17 When developing TOPSwitch flyback power supplies, transformer design is usually the biggest stumbling block. Flyback transformers are not designed or used like normal transformers. Energy is stored in the core. The core must be |
Original | ||||
| lc-ir-12 | LC-IR-12 Series Miniature 9 Watt Infrared Emitter This IR source is a thermal emitter with emissivity ~0.8. It is appropriate for use in lab or field instrumentation due to its long life and stable properties. The coiled resistance wire filament operates at 825oC |
Original | ||||
| mmbf5484lt1 | MOTOROLA Order this document by MMBF5484LT1/D SEMICONDUCTOR TECHNICAL DATA JFET Transistor N-Channel 2 SOURCE M M B F 5 48 4L T 1 Motorola Preferred Device MAXIMUM RATINGS Rating Symbol Value Unit VDG 25 Vdc v GS(r) 25 Vdc Forward Gate Current 'G(f) 10 mAdc |
OCR Scan | ||||
| ABRAC O N P RO DUC T CATAL O G September 2013 | ABRAC O N P RO DUC T CATAL O G September 2013 Crystals Real-Time Clocks Oscillators Filters Precision Timing RF & Microwave Magnetics & Capacitors Engineered Solutions Oscillators ASG 7.0 x 5.0 x 2.0mm Precision Timing Solutions ABLNO 9.2 x 14.8 x 5.5 mm SMT |
Original | ||||
| flyback transformer construction | ® TOPSwitch Flyback Transformer Construction Guide ® Application Note AN-18 Introduction Ferrite Core Manufacturer’s Catalogs This application note is a design and construction guide for margin wound or triple insulated wire wound flyback transformers suitable for use with TOPSwitch. Margin wound |
Original | ||||
| st200 | ST200 (R) TO P S w itch Reference Design Board POWER 95 to 370 VDC Input, 5 W Output INTEGRATIONS, INC. Product Highlights Low Cost Production Worthy Reference Design • Only 12 components! • Single sided board Low cost through-hole components |
OCR Scan | ||||
MODEL 13DVA Rev.A / 15DVA Rev.A HOOK-UP WARNING IMPROPER INSTALLATION OR OPERATION OF THIS CONTROL MAY RESULT IN INJURY TO PERSONNEL OR ELECTRONIC FAILURE. THE CONTROL MUST BE INSTALLED AND GROUNDED IN ACCORDANCE WITH LOCAL, STATE, AND NATIONAL SAFETY CODES. AT NO TIME |
Original | |||||
| Installation and Operation Manual KBMM™ FA+ L1 | Installation and Operation Manual KBMM™ FA+ L1 Surface Mount Technology DECEL L2 Solid State SCR DC Motor Speed Controls F+ J2 B T CL for Use with 1/100 – 3 HP, 90 and 180 Volt Permanent Magnet and Shunt Wound DC Motors* ACCEL P3 PWR ON J1 CONN1 EN AC Line Input: 115 and 208/230 Volts, 50/60 Hz |
Original | ||||
| emergency lighting systems and battery powered | Application Note 17 Issue 2 March 1996 Emergency Lighting Systems and Battery Powered Fluorescent Lighting High Current TO92 Switching Transistors Provide 87% DC-AC Conversion Efficiency David Bradbury Neil Chadderton Introduction E m e r g e n c y l i g h t i n g s y s te m s a r e |
Original | ||||
| Tel: 508-673-2900 Fax: 508-676-0885 General | Tel: 508-673-2900 Fax: 508-676-0885 General Specifications Model Wattage Rating IRV 600/1200 Terminals Resistance Range Each model in this series contains two identical, isolated resistors with two sets of terminals. There is a left upper and a left lower terminal |
OCR Scan | ||||
| Tel: 508-673-2900 Fax: 508-676-0885 General | Tel: 508-673-2900 Fax: 508-676-0885 General Specifications Model Wattage Rating IRV 600/1200 Terminals Resistance Range Each model in this series contains two identical, isolated resistors with two sets of terminals. There is a left upper and a left lower terminal |
OCR Scan | ||||
| 5642205 M / A - C O M P H I INC 85D 00418 D T - | 5642205 M / A - C O M P H I INC 85D 00418 D T - 31 ~ of DV42Q5S n/A-con p h i as inc de | s m e e o s n-channel enhancement-moae RF Power FETs designed for… HF/VHF Amplifiers Class A, B, or C High Dynamic Range Amp Benefits ooGoma t | 175mhz 6"25yJ 10dB |
OCR Scan | ||||
| an-32 | ® TOPSwitch-GX Flyback Design Methodology Application Note AN-32 Designing an off-line power supply involves many aspects of electrical engineering: analog and digital circuits, bipolar and MOS power device characteristics, magnetics, thermal considerations, safety requirements, control loop stability, etc. |
Original | ||||
| topswitch | ® TOPSwitch -FX Flyback Design Methodology Application Note AN-25 Basic Circuit Configuration This application note introduces a simple methodology for the design of off-line flyback power supplies using the TOPSwitch-FX family. It is fundamentally the same as AN-16, |
Original | ||||
|
|
||||||
| i s o t e k Tel: 508-673-2900 Fax: 508-676-0885 | i s o t e k Tel: 508-673-2900 Fax: 508-676-0885 General Specifications Model Wattage Rating IRV 600/1200 Terminais Resistance Range (Chasis Mounted) Inductive Non-Inductive 60 0.1-270 0 .1-56 80 0.1-910 0.1-110 0 .1 -1 .1K 0.1-240 IRH 60 Each model in this series |
OCR Scan | ||||
| dc3n-12d-4x-010-ai | 250-0287-rev2.qxd 3/12/01 10:27 AM Page a DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D-00-010-AI M/N DC3N-12D-4X-010-AI Instruction Manual D2-3452-1 250-0287-rev2.qxd 3/12/01 10:27 AM Page b The information in this manual is subject to change without |
Original | ||||
| Paktron Division of Illinois Tool Works Inc. 1205 | Paktron Division of Illinois Tool Works Inc. 1205 McConville Road, Post Office Box 4539 Lynchburg, VA 24502 Phone: 804-239-6941 FAX: 804-239-4730 Email: itwpaktron@paktron.com Web site: http://www.paktron.com TECHNICAL BULLETIN 3.01 Reprint from the proceedings of the 16th Annual Applied |
Original | ||||